GE Lighting Roadway Lighting M-250R2 (M2RR) imagination at work Product Features From HID to LED, GE continues to push Roadway Lighting to new heights. Recognized for the highest quality and reliability in street, highway, parkway, and commercial applications, GE offers a wide selection of styles to meet the lighting needs of municipalities, utilities, DOT customers and more. Applications Unique Features • For lower wattage roadway applications including residential streets, parking lots and other long, narrow areas • Adjustable mogul base socket (street side) – E39 standard • No-tool PE receptacle • Plug-in ignitor • Plastic pest guard standard (not required for 2 in. pipe) Housing • Die-cast aluminum housing • External stainless steel bail latch Finish • Polyester powder gray paint finish Rating • / Listed for wet location available as an option Mounting • Universal two-bolt slipfitter • Metal pest guard standard (not required for 2 in. pipe mounting) Ordering Number Logic M-250R2 (M2RR) M 2 R R ____ __ PROD. ID WATTAGE M2RR = M-250R2 _ LIGHT SOURCE E = Energy Act 05 = 50 Compliant Pulse 07 = 70 MH (EPMH) 10 = 100 15 = 150 S = HPS (55V) 17 = 175 P = PMH 20 = 200 21 = 100/150 Standard: Lamp not included. (55V) 25 = 250 NOTE: Dual wattage connected for lower wattage _ _ VOLTAGE BALLAST TYPE SELECTION PE FUNCTION See Ballast Selection Table A = Autoreg G = Mag-Reg with Grounded Socket Shell H = HPF Reactor or Lag M = Mag-Reg N = NPF Reactor or Lag P = CWI with Grounded Socket Shell 60Hz 0 = 120/208/240/ 277 Multivolt 1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 7 = 120X240 8 = 240V Ballast 120V PE Receptacle not reconnectable D = 347 F = 120X347 T = 220 50Hz 6 = 220 R = 230 Y = 240 NOTE: Dual voltage connected for lower voltage _ _ _ LENS TYPE (PRISMATIC) REFRACTOR IES DISTRIBUTION TYPE 1 = None 2 = PE Receptacle See Photometric Selection Table See Photometric Selection Table NOTE: Receptacle connected same voltage as unit except as noted. Order PE Control separately. A = Acrylic G = Glass L = Polycarbonate M = Medium L = Long NOTE: 150 watt Maximum with Acrylic or Polycarbonate Refractors. S = Semi-cutoff N = Non-cutoff 2 = Type II 3 = Type III _ OPTIONS C = Charcoal filter F = Fusing (Not available with multivolt or dual voltage) J = Line Surge Protector, Expulsion Type (UL not available) N = Meets proposed ANSI C136.31 requirements for Bridge and Underpass Vibration U = / listed with glass only (60Hz only) Ballast Selection Table Ballast Type/Voltage Ballast Type/Voltage 60Hz 50Hz Wattage Light 347 240/120 Source Multivolt 120 208 240 277 480 120X240 120X347 PER 220 230 220 230 240 50 HPS H,N H,N H,N H,N H,N H,N H,N H,N H,N N/A N/A N/A N/A N/A 70,100,150 (55V) HPS A,H,N A,G,H,M,N,P A,G,H,M,N A,G,H,M,N,P A,G,H,M,N G,M G,H,M,N,P G*,H,M*,N G,H,M,N H,M,N N/A H,M,N H N/A 100/150 (55V) HPS N/A H,N N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 200, 250 HPS A,P A,H,N,P A,H,N,P A,H,N,P A,P A,P** A,P A**,P A,H,N H H A,H,N H H 175, 250 EPMH A A A A A A A N/A A N/A N/A N/A N/A N/A 100• MH H,N H,N H,N H,N H,N H,N H,N H,N H,N N/A N/A N/A N/A N/A 150• PMH N/A A,H H A,H H N/A A,H H H N/A N/A N/A N/A N/A 250• EPMH A A A A A A A N/A A N/A N/A N/A N/A N/A NOTE: N/A = Not available. *Not available in 120 X 347. **Not available in 200 watt or 310 watt. • = Medium base socket Photometric Selection Table PHOTOMETRIC SELECTION TABLE All light sources are clear unless otherwise indicated. Lens Type Light (Prismatic Wattage Source Refractor) 50,70,100,150 (55 V) 50,70,100,150 (55 V) 50,70,100,150 (55 V) 200, 250 175, 250 *100,150 HPS Acrylic HPS Glass HPS Polycarb. HPS Glass EPMH Glass PMH Glass IES Distribution Type Photometric Curve Number 35 (Socket Postition) LN3 MN2 MN2 N/A N/A 177258(1A) N/A N/A N/A N/A N/A 177259(2A) N/A N/A N/A 177246(1A) 177247(2A) 177250(1A) 177251(2A) N/A 177256(2B) N/A N/A 177284(1A) 177279(2A) 17451483 N/A NOTE: N/A = Not Available PMH—Contact Manufacturer *Medium Base MN3 MS2 MS3 177244(2B) 177248(1.5B) 177311 177261(2DH) 177280(1B) 17451464 177245(2.5B) 177249(2.5B) N/A 177260(1DH) 177281(2B) N/A M2AC – Suggested Catalog Ordering Numbers Catalog Number Wattage Light Source Voltage Ballast (60 Hz) Type Refractor Photometric Type Distribution M2RR10S1N2AMS2 100 M2RR15S1N2AMS3 150 M2RR25S0A2GMS3 250 120 NPF Reactor 120 NPF Reactor Multivolt Auto-Regulator Acrylic Acrylic Glass HPS HPS HPS MS2 MS3 MS3 All GE suggested catalog ordering numbers come with PE receptacle. PE control must be ordered separately. Order and install SCCL-PECTL if no PE is desired. Multivolt ballasts can be for either 120, 208, 240, or 277 volt incoming power supply. Product Dimensions 26.250 in. (667 mm) 13.250 in. (337 mm) Leveling Pad D ATA 10.625 in. (270 mm) Photoelectric Control Receptacle 4.750 in. (121 mm) • Approximate Net Weight: 20-30 lbs (9-14 kgs) • Effective Projected Area: 0.7 sq. ft. max. (0.07 sq. M max.) • Suggested Mounting Height: 20-40 ft. (6-12 M) www.gelighting.com GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of the General Electric Company. © 2014 GE. OLP2934 (Rev 11/04/14) Adjustable For 1-1/4 in. to 2 in. Pipe (1.660 in. to 2.375 in. OD) (42 to 60 mm OD) 18.000 in. (457 mm) Pole Clearance
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : GE Area Outdoor Lighting Fixtures Create Date : 2014:11:04 16:49:22-05:00 Keywords : GE, Roadway, Lighting;, OLP2934;, Outdoor, Lighting;, Datasheet;, lower, wattage, roadway, applications;, Roadway, Lighting;, M250R2 Modify Date : 2014:11:06 15:18:37-05:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:4538dccd-a5a5-4e51-9b96-0235164796a3 Original Document ID : adobe:docid:indd:1bacd13a-579f-11dc-a078-a0c8dc376177 Document ID : xmp.id:5acd23b2-6f76-43af-a764-f126afb30fca Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9a11b756-6b7c-4802-a51a-ad4ea321c430 Derived From Document ID : xmp.did:9495868C4820681188C6C75596B73A6B Derived From Original Document ID: adobe:docid:indd:1bacd13a-579f-11dc-a078-a0c8dc376177 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Macintosh) History Changed : / History When : 2014:11:04 16:49:22-05:00 Metadata Date : 2014:11:06 15:18:37-05:00 Creator Tool : Adobe InDesign CC (Macintosh) Format : application/pdf Title : GE Roadway Lighting M2RR M250R2 — Data Sheet | OLP2934 Creator : GE Area Outdoor Lighting Fixtures Description : From HID to LED, GE continues to push Roadway Lighting to new heights. Recognized for the highest quality and reliability in street, highway, parkway, and commercial applications, GE offers a wide selection of styles to meet the lighting needs of municipalities, utilities, DOT customers and more. Subject : GE Roadway Lighting, OLP2934, Outdoor Lighting, Datasheet, lower wattage roadway applications, Roadway Lighting, M250R2 Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 4EXIF Metadata provided by EXIF.tools