Ge Appliances Mark Controls Upgrades Fact Sheet GEA14803_MkIV VIe Migration
Ge-Mark-Controls-Upgrades-Fact-Sheet-648692 ge-mark-controls-upgrades-fact-sheet-648692
2015-08-07
: Ge-Appliances Ge-Mark-Controls-Upgrades-Fact-Sheet-648692 ge-mark-controls-upgrades-fact-sheet-648692 ge-appliances pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
GE Energy Mark* IV to Mark* VIe Migration Gas Turbine Controls Upgrade fact sheet Now you can upgrade your Mark* IV gas turbine control to Since the I/O modules are distributed via 100MB Ethernet, they GE’s latest technology, without changing your existing field can also be located in adjacent cabinets, such as generator terminations, field wiring, or turbine devices. GE Energy offers a protection panels to replace RTD monitors or analog meters on prefabricated package to enable a seamless Mark IV to Mark VIe the door. The “25” backup synch check relay is now a function migration, replacing all of the vintage electronics in the existing performed by redundant I/O modules and coordinated with Mark IV cabinet. Standard wire harnesses connect the new Mark another set of modules for auto synchronizing. VIe I/O to the Mark IV terminal boards with plug-in connectors to ensure point-to-point connectivity. Even basic power distribution is improved. For example, your Mark IV has two feeders to isolate critical and non-critical solenoids. The Reliability of a Modern Control System new I/O has a pair of on-board fuses to isolate every solenoid and In addition to retaining 100% of your field wiring and turbine diagnostics to monitor their status. devices, you also retain the same control and protection philosophy that has delivered operation and tripping reliability all these years. Operator Interface Your upgraded Mark VIe control will still be triple redundant, but The operator interface on the cabinet door is replaced with a with improved fault tolerance. For example, failure of an A/D modern HMI in the same location. Now, you have a Proficy* converter in the Mark IV causes one of the three controllers to HMI/SCADA CIMPLICTY* graphics package with accurate turbine trip, but not in Mark VIe. Also, on-line repair of Mark IV systems screens, convenient navigation, superior alarm management, require that one of the three controllers be taken off-line, but the and tools for editing, trending, data analysis, and exporting data. Mark VIe can be repaired on-line. The logging printer on the door is no longer needed since alarms are logged in the HMI. Similarly, the new Trip History handles Your board racks with hardwired backplanes are replaced with significantly more points, with better time resolution, and stores smart I/O modules with local distributed processors to interface data for 30 trips. with turbine devices. This eliminates berg jumpers for addressing, PROMs to change, and BRAM/EEPROM for non-volatile memory. Remote operator panels and Smart Remotes can be replaced with HMIs and Historians that communicate in client/server configuration I/O Enhancements on modern Ethernet networks. HMIs communicate directly with Your smart I/O modules will provide features like 1ms time-tags the redundant controllers, thereby eliminating the existing Mark IV for all contact inputs for Sequence of Events (SOE) monitoring. Communicator module and the need for a backup display. For units Additionally, the SOE can be synchronized between multiple units with DCS links, a replica of the Mark IV simple data dump protocol is and to a plant time source. Flame scanners will be continuously available along with Modbus*, OPC, and GSM. monitored to see the actual light intensity instead of the simple on/off indication of the Mark IV. fact sheet Configuration and Diagnostic Tools Benefits The Mark VIe comes with the ToolboxST* software suite. Application • Minimum downtime for upgrade by retaining field terminations software is upgraded from 16 bit integer data to 32 bit floating point and graphically represented as interconnected function and turbine devices • Improved fault tolerance and reliability blocks. Data can be dragged and dropped between blocks or onto trending screens. Features include block libraries, help files, math • Enhanced on-line repair at the I/O module level blocks, macros, logic and analog forcing. Changes to application • Modern HMI tools for ease of operation software can be made on-line without rebooting the controllers as required in Mark IV. ToolboxST is used to configure everything from I/O devices to networks and operator stations. It provides more extensive and precise diagnostics with clear messages to quickly identify fault locations and reduce mean-time-to-repair. • Modern maintenance tools and diagnostics to quickly identify faults • Flexible Ethernet networks to distribute data • Distributed I/O to integrate instrumentation in other cabinets • Compatible with all new turbine technology, such as dry low NOx Related Products Generator excitation upgrades are also available with cost-effective products, such as the Digital Front End (DFE), which replaces just the control portion of the exciter without affecting the power 4-. bridges. DFE shares the same ToolboxST software tools as the Mark VIe, HMIs, and has peer-to-peer Ethernet communications instead of hardwiring all signals. Ii Bently Nevada* Asset Condition Monitoring solutions are also "j available for the turbine and driven load equipment with communication on the same networks as the Mark VIe and DFE. Mark IV Mark VIe Contact Information GE Energy Control Solutions 3800 North Wilson Avenue Loveland, CO 80538 energy.controlsolutions@ge.com http://www.ge-energy.com/oc 800-835-5182 / +1 970-461-5201 ©2005, General Electric Company. All rights reserved. * Proficy and CIMPLICITY are registered trademarks of GE Fanuc Automation North America, Inc. Ethernet is a registered trademark of Xerox Corporation. Mark, ToolboxST and Bently Nevada are trademarks of the General Electric Company. Modbus is a registered trademark of Schneider Automation. GEA-14803 (10/06)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 for Macintosh Modify Date : 2006:10:30 13:59:50-05:00 Creator Tool : QuarkXPress: pictwpstops filter 1.0 Create Date : 2006:10:30 13:59:50-05:00 Format : application/pdf Creator : cochraad Title : GEA14803_MkIV-VIe Migration.qxd Document ID : uuid:deceff3f-6848-11db-93e2-00039354b428 Instance ID : uuid:decf559a-6848-11db-93e2-00039354b428 Page Count : 2 Author : cochraadEXIF Metadata provided by EXIF.tools