GT1TM LED
Pedestrian Signals
12 inch - Full Hand, Full Person,
Overlay, Countdown
Excellent Appearance & Visibility
• Robust LED system design enables high luminous intensity over long product life
• Efficient optical system minimizes power consumption while providing excellent
uniformity and viewing angles
• Single piece transparent front window with internal masking to prevent:
- icons display from being readily visible when not in operation
- scratches and abrasions compared with external silk screen technology
• Bright and clear icons
• New or retrofit use
• Fully uniform look
Outstanding Reliability & Robust Operation
• Individual power supply drives each display to ensure proper indication
Meets Rigorous Certification & Testing Standards
• Intertek ETL Verified compliant
• DOE compliant
• Using MIL-STD-810F for environmental robustness, passed reliability and qualification
testing including high temperature, high humidity cycling (HTHH for 1,000 hours)
• Production quality compliant to GE Six Sigma requirements
• Compliant with the ITE PTCSI LED Signal Modules - version dated August 2010
The Greatest Signals Stand the Test of Time.TM
GE
Lighting Solutions
GT1TM LED Pedestrian Signals
12 inch module
Mechanical Outline Dimensions in inches. (mm) indicates metric equivalent
Operating Specifications
Parameter Rating
Operating Temperature Range* -40 to +74°C (-40 to +165°F)
Operating Voltage Range 80 to 135 V (60Hz AC)
Power Factor (PF) > 90 %
Total Harmonic Distortion (THD) < 20 %
Voltage Turn-Off (VTO) 35 V
Start-up Time < 75msec
Lens & Shell Material UV Stabilized Polycarbonate
Wiring 16 AWG, Color Coded
with Strain Relief
LED Color Hand: Portland Orange
Person: Lunar White
Test Condition: Ta = 25ºC. All values are design or typical values when measured under laboratory conditions.
1 Class A
2 CSA approved
Distributed by:
Product Information
Model Number
Dimensions Symbol AC Voltage Power (W)1 Beam Pattern Mechanical
Nominal Degrees Outline
PS6-WFM3-26A 12 in x 12 in Full Person 120V - 60Hz 5 26 2 and 3
PS6-PFH1-26A 12 in x 12 in Full Hand 120V - 60Hz 5 26 1 and 3
PS6-CFL1-26A 12 in x 12 in Full Person / Full Hand / Overlay 120V - 60Hz 5 26 4 and 6
PS6-PFD1-26A 12 in x 12 in Countdown 120V - 60Hz 5 26 5 and 6
PS6-PFD1-26A-H32 12 in x 12 in Countdown Full/Half Cycle Jumper 120V - 60Hz 5 26 5 and 6
Design Compliance
Test type Compliance
ITE PTCSI LED Signal Modules
Luminous Intensity Version dated August 2010
Chromaticity ITE PTCSI LED Signal Modules
Version dated August 2010
Moisture Resistance Blown Wind Rain MIL-STD-810F
Test Method 506.4, Procedure 1
Mechanical Vibration MIL-STD-883 Method 2007
Electronic Noise FCC Title 47 Sec 15 Sub. B1
Transient Voltage Protection ITE PTCSI LED Signal Modules
Version dated August 2010
Controller Compatibility Nema TS-2-2003
Wiring NFPA 70, National Electric Code
Digits MUTCD 2003, Section 4E.07, Countdown
Numbers Minimum 9” Height & 7” Width
* Performed in compliance with ITE test method described in the technical notes
3.3"
(82)
3.9"
(100)
0.25"
(6.4)
10.4"
(264)
10.9"
(276)
5.8"
(147)
10.8"
(275)
1.7"
(40)
11.9"
(304)
11.9"
(304)
11.9"
(304)
11.9"
(304)
11.9"
(304)
11.9"
(304)
11.9"
(304)
11.9"
(304)
1 2 3 4 5 6
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. GT1 and “The Greatest Signals Stand the Test of Time” are trademarks of GE Lighting Solutions, LLC. The GE brand and logo are trademarks
of the General Electric Company. © 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
TRAF012-R050913

Navigation menu