Lumination™ LED Luminaires
Downlights Powered by Infusion™
RI8 - 8” Round Aperture
Convert any commercial or industrial downlight to LED with the new
Lumination RI Series retrofit LED downlight. Powered by the Infusion LED
downlight module, the RI series delivers exceptional efficacy and 90+ CRI
with high R9 across all lumen packages and color temperatures. Custom
engineered, spec-grade optical system provide an exceptional aesthetic
with 45° cutoff and no glare. Tool-free installation from below the ceiling
in just minutes. 50,000 hour life virtually eliminates maintenance costs.
Output up to 3460 lumens is ideal for high-ceiling applications.
Product Description:
Project name _________________
Date ________________________
Type ________________________
Ordering Information:
For shortest lead time and lowest price, order standard reflector options shown in bold.
Product Dimensions:
Distribution Patterns:
Narrow, Medium, Wide
Input Voltage:
120V, 277V
Standard Dimming Controls: 0-10V to 10%
CCT: 2700K, 3000K, 3500K, 4000K
CRI: 90
Color Consistency: 4 Step MacAdam Ellipse
Lifetime Rating: 50,000 Hours
Input Frequency (Hz): 60Hz
Power Factor: >0.9
Mounting Options: Universal mounting frame secures to existing rough-in kit
Weight: 6 lb
IC Rating:
Non-IC Rated
Temperature Rating: 35C max cavity temperature
Limited Warranty: 5 years system
Files Available: LM79, LM80, IES
Targeted Performance Summary:
Nominal Module Lumens 1000 1500 2000 3000 4000
Fixture Lumens 880 1300 1760 2650 3460
System Input Power 18 25 31 43 56
System Efficacy (LPW) 49 52 57 62 62
R I 8
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
HOUSING
RI8 = Retrofit Downlight,
Infusion, 8” Round
REFLECTOR
COLOR
FLANGE VOLTAGE 4
CL = Clear
CB2 = Black
CK2 = Gold
CP2 = Pewter
CT2 = Wheat
CW = White Paint
FM = Match Reflector
FW = White
1 = 120V, 0-10V dimming
2 = 277V, 0-10V dimming4
MODULE LUMENS
10 = 1000 LM
15 = 1500 LM
20 = 2000 LM
30 = 3000 LM
40 = 4000 LM
REFLECTOR
FINISH
RM = Semi-specular
RD = Diffused
RS = Specular
RP1 = Painted
BEAM
SPREAD
N = Narrow
M = Medium
W = Wide
CCT
27 = 2700K
30 = 3000K
35 = 3500K
40 = 4000K
High Lumen
(3000, 4000 lm)
A = 8.81 B = 8.37
Low Lumen
(1000, 1500, 2000 lm)
A = 8.81 B = 7.59
8.81
8.37
8.81
A
A
B
8.81
7.59
8.81
7.59
8.81
A
A A
B B
Performance claims are for clear specular reflectors.
Other reflector finishes and colors will have an effect on performance.
Listings:
• Suitable for damp locations.
347V Field Installed Transformer Kit
TR347/120-75VA
83264
8” Goof Ring, Specular Finish RIGR8RS3 78838
8” Goof Ring, Semi-Spec Finish RIGR8RM3 16114
8” Goof Ring, Diffused Finish RIGR8RD3 16166
8” Goof Ring, White Painted RIGR8WH3 16167
ACCESSORIES PRODUCT
CODE
DESCRIPTION
CODE
Ordering Notes:
1. Use with CW = White reflector color only.
2. Reflector colors (other than white paint) available with
RM = Semi-specular reflector finish only.
3. See back page of spec sheet for goof ring dimensional info.
4. 277V input, 1000 lumen version is not Energy Star certified.
LuminationTM RI8 Series Downlights
Photometric Data:
Narrow Distribution
COEFFICIENTS OF UTILIZATION
NOTE: Floor Cavity Reflectance : 20%
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 114 112 110 108 112 110 108 106 106 104 103 102 101 100 99 98 97 95
2 110 106 103 100 108 104 101 99 101 99 96 98 96 94 95 94 92 91
3 106 100 96 93 104 99 95 92 97 93 91 94 92 89 92 90 88 87
4 102 95 91 87 100 94 90 87 92 89 86 90 87 85 89 86 84 83
5 98 91 86 83 96 90 86 82 88 85 82 87 83 81 85 82 80 79
6 94 87 82 78 93 86 82 78 85 81 78 83 80 77 82 79 77 75
7 91 83 78 75 89 82 78 75 81 77 74 80 77 74 79 76 73 72
8 87 80 75 71 86 79 75 71 78 74 71 77 73 71 76 73 70 69
9 84 77 72 68 83 76 71 68 75 71 68 74 71 68 74 70 68 67
10 81 74 69 66 81 73 69 66 72 68 65 72 68 65 71 68 65 64
Zone Lumens Lumens Lumens Lumens Lumens % of Fixture
0 - 30° 765 1130 1531 2305 3010 87.0
0 - 40° 869 1283 1738 2617 3417 98.8
0 - 60° 879 1298 1758 2647 3456 99.9
0 - 90° 880 1299 1760 2649 3460 100.0
NOMINAL MODULE LUMENS
ZONAL LUMEN SUMMARY
1000 1500 2000 3000 4000
Angle Candela Candela Candela Candela Candela
0 2773 4096 5546 8349 10903
5 2590 3825 5179 7797 10182
10 1932 2853 3863 5816 7595
15 1175 1736 2350 3539 4621
20 776 1146 1551 2335 3050
25 546 807 1093 1645 2149
30 389 575 778 1171 1530
35 191 282 381 574 750
40 56 82 112 168 219
45 8 12 17 25 33
50 2 3 4 6 8
55 1 2 3 4 5
60 1 1 2 3 3
NOMINAL MODULE LUMENS
CANDLEPOWER SUMMARY
1000 1500 2000 3000 4000
Height fc fc fc fc fc Dia. (ft.)
6’ 77 114 154 232 303 2.7
8’ 43 64 87 130 170 3.5
10’ 28 41 55 83 109 4.4
12’ 19 28 39 58 76 5.3
14’ 14 21 28 43 56 6.2
16’ 11 16 22 33 43 7.1
18’ 9 13 17 26 34 8.0
20’ 7 10 14 21 27 8.9
NOMINAL MODULE LUMENS
CONE OF LIGHT
1000 1500 2000 3000 4000
APPLICATION REFERENCE (Open Space)
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane LLF: 1.0 Initial, 80/50/20 Reflectances, Light levels on the ground
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ x 4’ 57.0 0.96 84.1 1.38 113.9 1.74 152.5 2.46 199.2 3.24
6’ x 6’ 26.6 0.45 39.3 0.64 53.2 0.81 71.2 1.15 93.0 1.51
8’ x 8’ 14.2 0.24 21.0 0.35 28.5 0.44 38.1 0.62 49.8 0.81
10’ x 10’ 9.5 0.16 14.0 0.23 19.0 0.29 25.4 0.41 33.2 0.54
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ on ctr. 28.4 0.67 41.9 0.96 56.7 1.21 63.4 1.71 82.8 2.25
6’ on ctr. 19.3 0.45 28.5 0.65 38.6 0.82 43.1 1.16 56.3 1.53
8’ on ctr. 13.6 0.32 20.1 0.46 27.2 0.58 30.4 0.82 39.7 1.08
10’ on ctr. 11.3 0.27 16.8 0.38 22.7 0.48 25.3 0.68 33.1 0.90
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
APPLICATION REFERENCE (Corridor)
10’ ceiling, Open Space: 50’ x 40’ x 10’ 10’ ceiling, Corridor: 6’ W x 100’ L20’ ceiling, Open Space: 50’ x 40’ x 20’ 20’ ceiling, Corridor: 6’ W x 100’ L
Narrow – 1000, 1500, 2000 Lm
1396
10 20 30 40
2792
4188
5584
90
80
70
60
50
POLAR GRAPH
Narrow – 3000, 4000 Lm
10978
10 20 30 40
8234
5489
2745
90
80
70
60
50
POLAR GRAPH
Spacing Criteria: RI8 - Narrow = 0.46
Performance claims are for clear specular reflectors. Other reflector finishes and colors will have an effect on performance.
Medium Distribution
LuminationTM RI8 Series Downlights
Photometric Data:
COEFFICIENTS OF UTILIZATION
NOTE: Floor Cavity Reflectance : 20%
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 114 112 110 108 112 110 108 106 106 104 103 102 101 100 99 98 97 95
2 110 105 102 99 108 104 101 98 101 98 96 98 96 94 95 93 92 90
3 105 100 96 92 103 98 95 91 96 93 90 94 91 89 91 89 87 86
4 101 95 90 86 99 94 89 86 91 88 85 90 86 84 88 85 83 82
5 97 90 85 81 95 89 84 81 87 83 80 86 82 80 84 81 79 78
6 93 86 81 77 92 85 80 77 84 79 76 82 79 76 81 78 75 74
7 90 82 77 73 88 81 76 73 80 76 73 79 75 72 78 74 72 71
8 86 78 73 70 85 78 73 69 77 72 69 76 72 69 75 71 69 68
9 83 75 70 66 82 74 70 66 73 69 66 73 69 66 72 68 66 65
10 80 72 67 64 79 71 67 63 71 66 63 70 66 63 69 66 63 62
Zone Lumens Lumens Lumens Lumens Lumens % of Fixture
0 - 30° 770 1138 1541 2320 3030 87.6
0 - 40° 867 1281 1735 2613 3412 98.6
0 - 60° 878 1297 1757 2645 3454 99.8
0 - 90° 880 1299 1760 2649 3460 100
NOMINAL MODULE LUMENS
ZONAL LUMEN SUMMARY
1000 1500 2000 3000 4000
Angle Candela Candela Candela Candela Candela
0 1914 2827 3828 5763 7526
5 1861 2749 3723 5605 7319
10 1651 2438 3302 4971 6491
15 1289 1904 2578 3881 5069
20 928 1371 1857 2795 3650
25 638 943 1277 1922 2510
30 385 569 770 1159 1514
35 182 268 364 547 715
40 56 82 111 167 218
45 9 13 18 27 36
50 3 4 6 9 12
55 2 3 4 6 8
60 1 2 3 4 5
NOMINAL MODULE LUMENS
CANDLEPOWER SUMMARY
1000 1500 2000 3000 4000
Height fc fc fc fc fc Dia. (ft.)
6’ 53 79 106 160 209 4.1
8’ 30 44 60 90 118 5.5
10’ 19 28 38 58 75 6.9
12’ 13 20 27 40 52 8.3
14’ 10 14 20 29 38 9.6
16’ 7 11 15 23 29 11.0
18’ 6 9 12 18 23 12.4
20’ 5 7 10 14 19 13.8
NOMINAL MODULE LUMENS
CONE OF LIGHT
1000 1500 2000 3000 4000
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ on ctr. 28.4 0.67 41.9 0.96 56.7 1.21 63.4 1.71 82.8 2.25
6’ on ctr. 19.3 0.45 28.5 0.65 38.6 0.82 43.1 1.16 56.3 1.53
8’ on ctr. 13.6 0.32 20.1 0.46 27.2 0.58 30.4 0.82 39.7 1.08
10’ on ctr. 11.3 0.27 16.8 0.38 22.7 0.48 25.3 0.68 33.1 0.90
APPLICATION REFERENCE (Open Space)
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane LLF: 1.0 Initial, 80/50/20 Reflectances, Light levels on the ground
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ x 4’ 56.8 0.96 83.9 1.38 113.6 1.74 151.2 2.46 196.8 3.24
6’ x 6’ 26.5 0.45 39.1 0.64 53.0 0.81 70.6 1.15 91.8 1.51
8’ x 8’ 14.2 0.24 21.0 0.35 28.4 0.44 37.8 0.62 49.2 0.81
10’ x 10’ 9.5 0.16 14.0 0.23 18.9 0.29 25.2 0.41 32.8 0.54
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ on ctr. 27.7 0.67 41.0 0.96 55.5 1.21 60.1 1.71 77.4 2.25
6’ on ctr. 18.9 0.45 27.8 0.65 37.7 0.82 40.9 1.16 52.6 1.53
8’ on ctr. 13.3 0.32 19.7 0.46 26.6 0.58 28.9 0.82 37.1 1.08
10’ on ctr. 11.1 0.27 16.4 0.38 22.2 0.48 24.1 0.68 30.9 0.90
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
APPLICATION REFERENCE (Corridor)
10’ ceiling, Open Space: 50’ x 40’ x 10’ 10’ ceiling, Corridor: 6’ W x 100’ L20’ ceiling, Open Space: 50’ x 40’ x 20’ 20’ ceiling, Corridor: 6’ W x 100’ L
Medium – 1000, 1500, 2000 Lm
959
10 20 30 40
1918
2876
3835
90
80
70
60
50
POLAR GRAPH
Medium – 3000, 4000 Lm
7539
10 20 30 40
5654
3770
1885
90
80
70
60
50
POLAR GRAPH
Spacing Criteria: RI8 - Medium = 0.64
Performance claims are for clear specular reflectors. Other reflector finishes and colors will have an effect on performance.
Wide Distribution
LuminationTM RI8 Series Downlights
Photometric Data:
COEFFICIENTS OF UTILIZATION
NOTE: Floor Cavity Reflectance : 20%
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 113 110 107 105 110 108 105 103 104 102 100 100 98 97 96 95 94 92
2 106 101 97 93 104 99 95 92 96 93 90 93 90 88 90 88 86 84
3 100 93 87 83 98 92 86 82 89 85 81 86 83 80 84 81 78 77
4 94 86 79 75 92 84 79 74 82 77 73 80 76 72 78 75 72 70
5 88 79 72 68 87 78 72 67 76 71 67 74 70 66 73 69 65 64
6 83 73 66 61 81 72 66 61 71 65 61 69 64 60 68 63 60 58
7 78 68 61 56 77 67 60 56 65 60 55 64 59 55 63 58 55 53
8 73 63 56 51 72 62 56 51 61 55 51 60 54 51 59 54 50 49
9 69 58 51 47 68 58 51 47 57 51 47 56 50 46 55 50 46 45
10 65 54 48 43 64 54 47 43 53 47 43 52 47 43 51 46 43 41
Zone Lumens Lumens Lumens Lumens Lumens % of Fixture
0 - 30° 466 689 933 1405 1835 53.0
0 - 40° 768 1134 1536 2313 3020 87.3
0 - 60° 877 1296 1755 2643 3452 99.8
0 - 90° 880 1299 1759 2649 3460 100.0
NOMINAL MODULE LUMENS
ZONAL LUMEN SUMMARY
1000 1500 2000 3000 4000
Angle Candela Candela Candela Candela Candela
0 472 698 945 1422 1857
5 469 692 937 1411 1843
10 455 673 911 1371 1790
15 462 683 924 1391 1817
20 558 824 1115 1679 2193
25 615 909 1230 1852 2419
30 631 932 1263 1901 2482
35 539 796 1078 1622 2119
40 323 477 646 972 1270
45 137 202 274 412 538
50 45 66 90 135 177
55 5 7 10 15 19
60 2 3 3 5 7
NOMINAL MODULE LUMENS
CANDLEPOWER SUMMARY
1000 1500 2000 3000 4000
Height fc fc fc fc fc Dia. (ft.)
6’ 13 19 26 40 52 7.2
8’ 7 11 15 22 29 9.6
10’ 5 7 9 14 19 12.0
12’ 3 5 7 10 13 14.4
14’ 2 4 5 7 9 16.8
16’ 2 3 4 6 7 19.2
18’ 1 2 3 4 6 21.6
20’ 1 2 2 4 5 24.0
NOMINAL MODULE LUMENS
CONE OF LIGHT
1000 1500 2000 3000 4000
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane, Light levels on the ground
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ on ctr. 21.6 0.67 31.9 0.96 43.2 1.21 37.2 1.71 48.6 2.25
6’ on ctr. 14.7 0.45 21.7 0.65 29.4 0.82 25.3 1.16 33.1 1.53
8’ on ctr. 10.4 0.32 15.3 0.46 20.7 0.58 17.9 0.82 23.3 1.08
10’ on ctr. 8.6 0.27 12.8 0.38 17.3 0.48 14.9 0.68 19.5 0.90
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
APPLICATION REFERENCE (Corridor)
10’ ceiling, Corridor: 6’ W x 100’ L 20’ ceiling, Corridor: 6’ W x 100’ L
Wide – 1000, 1500, 2000 Lm
319
10 20 30 40
638
957
1276
90
80
70
60
50
POLAR GRAPH
Wide – 3000, 4000 Lm
2510
10 20 30 40
1882
1255
627
90
80
70
60
50
POLAR GRAPH
APPLICATION REFERENCE (Open Space)
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane, Light levels on the ground
Spacing Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
Avg. fc W/ft
2
4’ x 4’ 54.7 0.96 80.8 1.38 109.4 1.74 136.9 2.46 178.7 3.24
6’ x 6’ 25.5 0.45 37.7 0.64 51.1 0.81 63.9 1.15 83.4 1.51
8’ x 8’ 13.7 0.24 20.2 0.35 27.4 0.44 34.2 0.62 44.7 0.81
10’ x 10’ 9.1 0.16 13.5 0.23 18.2 0.29 22.8 0.41 29.8 0.54
NOMINAL MODULE LUMENS
1000 1500 2000 3000 4000
10’ ceiling, Open Space: 50’ x 40’ x 10’ 20’ ceiling, Open Space: 50’ x 40’ x 20’
Spacing Criteria: RI8 - Wide = 1.52
Performance claims are for clear specular reflectors. Other reflector finishes and colors will have an effect on performance.
For more information and access to all of our resources, including our
design tool visit: www.gelighting.com
Installation:
• Universal mounting frame installs from below the ceiling and secures to existing
rough in kit with 3 mounting clamps
• Hinged J-box eases installation through ceiling hole and then flips into traditional
remodel housing position
• Included tether secures to existing fixture frame for hands-free wiring
Construction:
• 18 gauge galvanized steel housing
• 14 gauge aluminum reflectors resist dents during transportation and installation
• Custom engineered heat sinks for passive cooling at all lumen option
Optical System:
• Custom engineered reflectors for precise beam distributions and 45° cutoff to light source
and source image
• Self-flanged design with white or reflector-matching flange
• Available in specular, semi-specular, and diffused finishes in 10 different colors to precisely
match exisitng fixtures
• Reflector is retained by four torsion springs to ensure uniform seating to LED module for
exceptional light distribution for the life of the product
Electrical System:
• Infusion DLM LED module for exceptional performance and tool-free upgradeability
• Standard 0-10V dimming, high efficiency drivers
• Pre-wired with 30” flexible armored cable and push-in connector compatible with 1/2” knockout
on existing junction box
• Thermal protection feature in module protects LEDs from overheating in abnormal conditions
Product Specifications:
36 Inches
16 Inches
• SPACING REQUIREMENTS FOR FIXTURE: EACH INDIVIDUAL FIXTURE NEEDS TO
HAVE 576 SQUARE INCHES OF SPACE BEFORE ANY OBJECT/OBSTRUCTION
• THERMAL PROTECTION FEATURE PRESENT IN MODULE THAT PROTECTS LEDS
FROM OVERHEATING IN ABNORMAL CONDITIONS
A Width of Frame with Swing Arm Extended 12.51”
B Height from Bottom of Reflector to Top of Heat Sink 8.37” High Lumen
7.39” Low Lumen
C Height from Bottom of Reflector to Top of Frame 5.57”
D Reflector Diameter 8.80”
E Cut-Out Dimension for Ceiling 7.88” - 8.50”
8.5” - 9.75” (w/Goof Ring)
F Maximum Ceiling and Rough-in Kit Thickness 3.00”
PARAMETER FRAME SIZE 8”
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property
of their respective owners. Information provided is subject to change without notice. All values are design or typical
values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of
the General Electric Company. © 2014 GE.
IND092 (Rev 10/13/14)