Ge Crxflex Cr Scanner Brochure
Ge-Crxflex-Cr-Scanner-Brochure-648806 ge-crxflex-cr-scanner-brochure-648806
2015-03-09
: Ge Ge-Crxflex-Cr-Scanner-Brochure-648806 ge-crxflex-cr-scanner-brochure-648806 ge pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
GE Sensing & Inspection Technologies CR Flex x Computed Radiography Reliability, Versatility and Performance in Harsh NDT Environments The CRxFlex computed radiography scanner from GE Sensing & Inspection Technologies combines flexibility, reliability, dynamic range and ease-of-use. Designed specifically for applications in non-destructive testing, the CRxFlex is suitable for usage with both isotopes and X-ray sources. It is well suited for a broad range of applications in the aerospace, oil & gas, power generation and automotive industries. Extending the Boundaries of Computed Radiography Versatility Superior Image Quality The CRxFlex phosphor scanner also offers extremely wide dynamic range and high signal-to-noise ratio, which typically results in streamlined technique development and higher component throughput. A broad range of thicknesses can be inspected in a single exposure with the wide dynamic range making the CRxFlex a perfect match for the inspection of castings and/or piping for erosion/corrosion. This capability also leads to less exposures and fewer re-takes. Because of its specially designed optics, true square 50 micron pixel size and its unique 30 micron laser spot size, the CRxFlex can guarantee image quality with excellent IQI sensitivity. This superior image quality is supported by its BAM certificate that states that CRxFlex is IP Class Special/60 (ASTM E2446-05) and/or IP Class 1/60 (EN 14784-1) — ideal for weld inspection. Rhythm® Software Flexibility One of the more unique features that the CRxFlex offers is it’s ability to be utilized with either hard cassettes (in which the phosphor imaging plate never leaves the cassette) or the ability to scan any size of phosphor screen up to 35 x 43 cm (14 x 17 inches): any unique shape or size: circles, triangles, rectangles, pie shape, etc. These unique sizes can be exposed using a soft, flexible cassette and then scanned by the CRxFlex. Reliability The robust CRxFlex has a small tabletop footprint and is designed for reliable operation in the harshest of NDT environments. Its modular internal construction allows ease of servicing and features long mean-times-between-failures (MTBF) and maintenance (MTBM) — minimizing downtime and maximizing uptime. Horizontal Transport System The CRxFlex has a state-of-the-art, horizontal transport system that is designed to have limited, or no direct contact with the imaging plate during the scanning process. The result of this is that there is no imaging plate damage and/or physical wear that occurs during the scan. The phosphor scanner can accept imaging plates that are used with soft cassettes and/or can be used in a hard cassette for applications in which the imaging plate would not have to be removed from the cassette — extending the life of the imaging plate. The CRxFlex, in conjunction with the GE’s Rhythm software, allows users to acquire, review, report and archive inspection data. The DICONDE-compliant Rhythm platform also permits image enhancement and data sharing to provide significant improvements in productivity and faster identification of defect indications. Applications The CRxFlex is suitable for a wide range of applications spanning various industries. Aerospace Manufacturing On-wing inspection Oil & Gas Plant construction Asset management On-stream inspection Power generation Plant construction Asset management Automotive Component manufacturing Assembly inspection Imaging Plates Our offering consists of different types of phosphor imaging plates. The plates have special/proprietary protection layers that prevent scratches and damage. Odd sizes and/or shapes up to 35 x 43 cm (14” x 17”) imaging plates and associated inserts can be manufactured to support your specific application and scanned by the CRxFlex. Fewer Retakes High tolerance for varying exposure conditions and a greater freedom in the selection of the exposure dose. Dose Reduction In many cases, imaging plates allow the visualization of all diagnostic information with only one exposure. Long Lifetime Imaging plates are protected by an EBC (electron-beam-cured) topcoat. This results in plates with superb protection from mechanical wear and excellent chemical resistance. Image Quality The composition of the imaging plate storage phosphor material ensures optimum performance. The material has high absorption efficiency, excellent homogeneity and short response time to ensure high sharpness and contrast. Cassettes GE cassettes are specifically designed for NDT applications. The CR cassettes are lightweight and very simple to use. Synthetic material provides maximum rigidity for overall durability. The higher radiation energies used in industrial X-ray makes the use of standard medical cassettes impossible. Therefore, the cassettes can be supplied with built-in, front lead (Pb) screens of 250µm (0.010”) and are always lead-backed with 150µm (0.006”) to ensure optimal backscatter protection resulting in optimal image quality. Make-up of phosphor imaging plates Protective EBC Coat Phosphor Layer Conductive Layer Support P.E.T. Laminate Technical Specifications - CRxFlex Functional Data Throughput (Cassettes/Hour) 35 x 43 cm (14 x 17”) 18 x 24 cm (7 x 9”) 54/Hour @ 100 µm 27/Hour @ 50 µm 80/Hour @ 100 µm 40/Hour @ 50 µm Multi-plate scanning e.g. 4 x (6 x 24 cm) OR 4 x (4.5 x 10”) Laser Spot Size Pixel Size Bit Depth Image Buffer Certifications Dimensions Weight Interface 216/Hour @ 100 µm 108/Hour @ 50 µm 30 µm 50 µm and 100 µm 16-bit Linear 256 MB CE, UL, RoHS, CCC, WEEE 693 W x 786 D x 497 mm H (27.3 W x 30.9 D x 19.6" H) 75 kg (165 lb) FireWire (IEEE 1394) Electrical Data Voltage Frequency Power Consumption 100 - 240 V AC, autosensing 50/60 Hz 120 W standby, 320 W peak Consumables Imaging Plate Sizes Custom Imaging Plate Sizes Cassette Sizes All sizes up to 35 x 43 cm (14 x 17") Any size and/or shape up to 35 x 43 cm (14 x 17") 35 x 43 cm (14 x 17") 15x 30 cm (6 x 12") 18 x 24 cm (7 x 9.5”) www.gesensinginspection.com GEIT-40044EN(02/09) © 2009 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56 Create Date : 2009:04:06 14:56:41+02:00 Metadata Date : 2009:04:06 14:57:04+02:00 Modify Date : 2009:04:06 14:57:04+02:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 7884 bytes, use -b option to extract) Instance ID : uuid:c8833f34-d022-4885-8932-52dbcb971de0 Document ID : adobe:docid:indd:98fcb6f2-0e22-11de-95df-d4a2cba32591 Rendition Class : proof:pdf Derived From Instance ID : 98fcb6f1-0e22-11de-95df-d4a2cba32591 Derived From Document ID : adobe:docid:indd:bc99e690-0990-11de-903b-bb83d6ddbd65 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 300.00, 72.00 Manifest Placed Y Resolution : 300.00, 72.00, 300.00, 72.00, 72.00, 300.00, 72.00, 300.00, 300.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:0367D206067C11DE9C9DF2D40DE4EA1F, uuid:82b4576a-70df-415d-bdc7-4d3c4251e0d1, uuid:9B10306B0A3A11DEA01FDBC7A6997CA3, uuid:EB2768B70E2A11DEA01FDBC7A6997CA3, uuid:376779750E2A11DEA01FDBC7A6997CA3, uuid:4D5E80AB0E2C11DEA01FDBC7A6997CA3, uuid:67e03e32-ee3c-11db-a8a4-972a08f8a2fe, uuid:ECEEB7D90A3C11DEA01FDBC7A6997CA3, uuid:0ED2DEFD0A3911DEA01FDBC7A6997CA3, uuid:6cddbe45-0df5-11dc-a335-000d9345385c Manifest Reference Document ID : uuid:3F7443D0067A11DE9C9DF2D40DE4EA1F, uuid:08328253-029f-11db-8319-000d9345385c, uuid:9B10306A0A3A11DEA01FDBC7A6997CA3, uuid:EB2768B60E2A11DEA01FDBC7A6997CA3, uuid:376779740E2A11DEA01FDBC7A6997CA3, uuid:4D5E80AA0E2C11DEA01FDBC7A6997CA3, adobe:docid:photoshop:67e03e31-ee3c-11db-a8a4-972a08f8a2fe, uuid:ECEEB7D80A3C11DEA01FDBC7A6997CA3, uuid:0ED2DEFC0A3911DEA01FDBC7A6997CA3, uuid:08328253-029f-11db-8319-000d9345385c Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools