Transportation
The ElectroLogIXS family of wayside electronics is designed
to simplify the way you control your railroad. This versatile
platform can be configured for advanced interlocking control,
for crossing prediction, or for intermediate signaling.
Sharing modules and software tools across these applications
can decrease your design time, simplify installation and
maintenance, maximize training effectiveness, and reduce
spares inventory requirements.

The ElectroLogIXS XP4 supports a wide range of highwayrail grade crossing applications, incorporating constant
warning time and motion detection control, crossing island
train detection, vital input monitoring, vital relay drive output
control and ground fault detection. Vital serial communication
ports enable the ElectroLogIXS XP4 to communicate with
ElectroLogIXS, EC5, or VHLC systems. It can be expanded
to add radio signaling capabilities or to operate remotely
through a vital serial data port.

I 	 ElectroLogIXS VLC for interlocking control
X 	ElectroLogIXS XP4 for crossing prediction
S ElectroLogIXS EC5 for intermediate signaling

ElectroLogIXS XP4
For Crossing Prediction

Architecture

Recording and Analysis

Specifications

The ElectroLogIXS XP4 consists of a
chassis, motherboard, plug-in modules,
a CDU-1 Control Display Unit and
personality modules with terminal
blocks for hard wiring the system
to external crossing controllers. All
modules have front-panel indicators
that display module health status, and
function indicators for monitoring active
I/O signals. The CDU-1 or a computer/
terminal connected to the diagnostic
port serves as the human/machine
interface for system installation and
setup, parameter adjustment, and
system testing and troubleshooting.

The ElectroLogIXS XP4 has a built-in
recorder that logs time-stamped
vital and non-vital events as well as
internal logic state changes, crossing
performance data, and failures/reset
information. All recorded events can
be printed both track side and in the
office. A set of resident diagnostic
programs provides the tools necessary
to perform system event analysis and
troubleshooting.

Number of Tracks		
Up to 4 normal/standby

Advanced Train Detection
Applying track-tested principles from
generations of previous crossing
processors, the ElectroLogIXS XP4
broadens crossing capabilities to fourtrack normal/standby monitoring and
adds flexibility in crossing prediction
for four quadrant gate and quiet zone
crossings. The Crossing Track Interface
(XTI-1S) module integrates approach
and island circuits. It’s compatible with
high-current cab signals.

Recorded data may be displayed
in a graphical format using
GE - Transportation’s Graphical Data
Analyzer, or you can play back the
sequence of events using Graphical
Data Player.

Maximum Track Length	
7500 feet depending on ballast
	 and frequency
Approach Frequencies	
86Hz to 979Hz
Nine Island Frequencies	
4Khz to 8Khz
MDR Controls	
12 per track
Operating Voltage	
9.5 to 16.5 VDC

Application
Application templates minimize setup
and configuration time in the field on
even the most complex applications.
Existing templates are user configurable
and may be customized utilizing Logic
Station, GE - Transportation’s suite of
application development tools.
Programmable MDR drives (12 per track) 	
provide control for:
	 Remote start operation
	 Traffic signal preemption
	 MD relay drive
	 Island relay drive

Visit us online at
www.getransportation.com

doc20045-B



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1.1-111
About                           : 1ae3581b-dffc-11d9-b5fe-a2ed1beec9a2
Create Date                     : 2006:05:22 15:48:29-05:00
Metadata Date                   : 2006:05:22 15:48:33-05:00
Modify Date                     : 2006:05:22 15:48:33-05:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9228 bytes, use -b option to extract)
Instance ID                     : uuid:55cb3a54-e9d4-11da-b989-000393bd7fae
Document ID                     : adobe:docid:indd:a0a21f56-cf8b-11da-abef-851407de5a3d
Rendition Class                 : proof:pdf
Derived From Instance ID        : a0a21f55-cf8b-11da-abef-851407de5a3d
Derived From Document ID        : adobe:docid:indd:37bafa2f-9c5e-11d9-b076-c30d72265e57
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 300.00
Manifest Placed Y Resolution    : 300.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:8DB33C6FD76611DAAAB1DEC0D8324F4F
Manifest Reference Document ID  : uuid:E54B28B9CF9011DA9BD1CE65248F61C9
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS2 (4.0)
EXIF Metadata provided by EXIF.tools

Navigation menu