Ge M 400R2 Data Sheet Roadway Lighting M4AR M400A2 Power Door — | OLP2929
Ge-M-400R2-Data-Sheet-649464 ge-m-400r2-data-sheet-649464
2015-03-09
: Ge Ge-M-400R2-Data-Sheet-649464 ge-m-400r2-data-sheet-649464 ge pdf
Open the PDF directly: View PDF .
Page Count: 4
GE
Lighting
imagination at work
M-400A2 Powr/Door™ (M4AR)
Roadway Lighting
Applications
• For street, highway and parking lot lighting
Housing
• Die-cast aluminum housing.
• External stainless steel bail latch
Finish
• Polyester powder gray paint finish
Mounting
• 1.25” - 2” universal four-bolt slipfitter
Reflectors
• ALGLAS™ finish on reflector
Unique Features
• Plug-in ignitor
• Filtered Optics
• No-tool PE receptacle
• Powr/Module ballast assembly
From HID to LED, GE continues to push Roadway Lighting to new heights. Recognized for the highest quality and reliability
in street, highway, parkway, and commercial applications, GE offers a wide selection of styles to meet the lighting needs
of municipalities, utilities, DOT customers and more.
Product Features
Light 240/120
Wattage Source Multivolt 120 208 240 277 480 120X240 PER ECPT
150 (55V) HPS H,N H,M,N M M M M H,M,N M
200 HPS A,M A,H,M,N A,H,M,N A,H,M,N A,M A,M A,M A,H,M,N
250 HPS A,M A,H,M,N A,H,M,N A,H,M,N A,M A,M A,M A,H,M,N
310 HPS A,M A,M A,H,M,N A,H,M,N A,M A,M A,M A,H,M,N
400 HPS A,M A,M A,H,M,N A,H,M,N A,M A,M A,M A,H,M,N
250/400 HPS A A A A A A N/A N/A
M 4 A R S G F
_ _ _ _ _ _ _ _ _ _ _ _ _ _
PROD. ID
VOLTAGE FILTER
OPTIONS
PE
FUNCTION
LENS
TYPE
IES
DISTRIBUTION
TYPE
WAT TAGE LIGHT
SOURCE
Ordering Number Logic
M-400A2 Powr/Door™ (M4AR)
BALLAST
TYPE
SELECTION
1 = None
2 = PE Receptacle
NOTE: Receptacle
connected same
voltage as unit
except as noted.
Order PE Control
separately.
M4AR =
M-400A2
15 = 150 (55V)
20 = 200
24 = 250/400
25 = 250
31 = 310
40 = 400
NOTE: Dual
wattage
connected for
lower wattage
S = HPS
Standard: Lamp
not included.
60Hz
0 = 120/208/240/
277 Multivolt
1 = 120
2 = 208
3 = 240
4 = 277
5 = 480
7 = 120X240
8 = 240V
Ballast 120V PE
Receptacle not
reconnectable
NOTE:
120X240
connected for
120V
1 = Fiber
gasket
2 = Charcoal
with
elastomer
gasket
G = Glass, sag See Photometric
Selection Table
M = Medium
S = Semi-cutoff
N = Non-Cutoff
2 = Type II
3 = Type III
See Ballast
Selection Table
A = Autoreg
H = HPF
Reactor
or Lag
M = Mag-Reg
N = NPF
Reactor
or Lag
F = Fusing (Not
available with
multivolt or
dual voltage)
NOTE: N/A = Not available.
Ballast Selection Table
Light
Wattage Source MN2 MN3 MS2 MS3
150 (55V) HPS N/A N/A N/A 177362(3E)
200, 250, 310, 400 HPS N/A 177322(2A) N/A 177321(2C)
PHOTOMETRIC SELECTION TABLE
All light sources are clear unless otherwise indicated.
IES Distribution Type
Photometric Curve Number 35 (Socket Postition)
All with glass only
NOTE: N/A = Not Available C/F = Contact Manufacturer
Photometric Selection Table
Ballast Type/Voltage
Product Dimensions
• Approximate Net Weight: 33-39 lbs (15-18 kgs)
• Effective Projected Area: 1.1 sq. ft. max. (0.1 sq. M max.)
• Suggested Mounting Height: 30-50 ft. (9-15 M)
DATA
35.500 in. (902 mm)
Photoelectric
Control Receptacle
Leveling Pad
12.000 in. (305mm)
Minimum Distance
Required to
Remove Door
5.375 in. (137 mm)
17.250 in.
(438 mm)
13.750 in.
(349 mm)
Adjustable For 1-1/4 in. to 2 in. Pipe
(1.660 in. to 2.375 in. OD)
(42 to 60 mm OD)
23.000 in. (584 mm) Radius for
Swing of Refractor Door
14.000 in. (356 mm) Radius
for Swing of Door
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property
of their respective owners. Information provided is subject to change without notice. All values are design or typical
values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of
the General Electric Company. © 2014 GE.