3500XL
Portable Generator Owner’s Manual
Pro
blem
Q
u
Bef
e
sti s?
ore
bac takin ons?
g
k

call to th your
u
e
the
gen store, nit
h
1-80 elpline erator
0-2 at

M-F 70-1
8-5 408
CT

Model No. 9441–5 (3500 Watt AC Generator) Manual No. 99112 Revision 4 (9/8/2000)

Visit our Generac website: www.generac–portables.com
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.

Generac Portable Products 3,500 Watt Generator

EQUIPMENT
DESCRIPTION

SAFETY RULES
This generator set was designed and manufactured for
specific applications. Do Not attempt to modify the unit
or use it for any application it was not designed for. If you
have any questions about your generator’s application, ask
your dealer/distributor or consult the factory.

This generator is an engine-driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads. This manual
contains information for a generator that operates 120
and/or 240 Volt, single phase, 60 Hz devices that require up
to 3,500 watts (3.5 kW) of power that pull up to
29.2 Amps at 120 Volts or 14.6 Amps at 240 Volts.

The manufacturer could not possibly anticipate every
circumstance that might involve a hazard. For that reason
warnings in the manual and warnings on tags or decals
affixed to the unit are not all–inclusive. If you intend to
handle, operate or service the unit by a procedure or
method not specifically recommended by the manufacturer,
first make sure that such a procedure or method will not
render this equipment unsafe or pose a threat to you and
others.

CAUTION! Do Not exceed the generator’s
wattage/amperage capacity. Add up the rated watts
of all devices you are connecting to generator
receptacles at one time. This total should not be
greater than 3,500 watts. In most cases rated watts
of the electrical device can be found on the device
nameplate. If the device nameplate gives only volts
and amps, multiply volts times amps to obtain watts
(volts X amps = watts).
The 3,500 watt generator has the following features:

Read this manual carefully and become familiar
with your generator set. Know its applications, its
limitations and any hazards involved.

WARNING:
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects, or other
reproductive harm.

• 120/240 Volt, 20 Amp locking type receptacle and a
120 Volt, 30 Amp locking type receptacle.
• 120 Volt, 15 Amp receptacles.

DANGER! You must isolate the generator from

• Low Oil Shutdown: Automatically shuts down the engine
if oil drops below safe operation level.

the electric utility by opening the electrical system’s
main circuit breaker or main switch if this unit is
used for backup power. Failure to isolate the
generator from the power utility may result
in injury or death to electric utility workers
and damage to the generator due to a backfeed
of electrical energy. Whenever unit is providing
backup power, the electric utility must be notified.

• Four gallon overhead fuel tank with fuel gauge.
• The generator’s revolving field is driven at about
3,600 rpm by a Generac Power Systems 6.5 h.p. engine.

WARNING! Do Not tamper with engine
governed speed. High operating speeds are
dangerous and increase risk of personal injury or
damage to equipment. The generator supplies
correct rated frequency and voltage only when
running at proper governed speed. Incorrect
frequency and/or voltage can damage some
connected electrical loads. Operating at excessively
low speeds imposes a heavy load. When adequate
engine power is not available engine life may be
shortened.

DANGER! Generator exhaust gases contain
DEADLY carbon monoxide gas. Carbon
monoxide, if breathed in sufficient
concentrations, can cause unconsciousness or
death. Operate this equipment outdoors where
adequate ventilation is available.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency. For warranty information refer to the
engine owner’s manual.

2

Generac Portable Products 3,500 Watt Generator

• The generator produces a very powerful voltage that can
cause serious injury or death by electrocution. Never
touch bare wires or receptacles. Never permit a child
or any unqualified person to operate the generator.

• Never operate the generator:
in rain; in any enclosed compartment; when connected
electrical devices overheat; if electrical output is lost; if
engine or generator sparks; if flame or smoke is
observed while unit is running; if unit vibrates
excessively.

• Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet
are wet. Death or serious injury from electrocution may
result.

GROUNDING THE
GENERATOR

• Use a ground fault circuit interrupter (GFCI) in any damp
or highly conductive area (such as metal decking or steel
work).

The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure 1).

• Never use worn, bare, frayed or otherwise damaged
electrical cords with the generator. Death, serious injury
and property damage from electrical shock may result.
• Gasoline is highly FLAMMABLE and its vapors
are EXPLOSIVE. Never allow smoking, open
flames, sparks or heat in the vicinity while
handling gasoline. Avoid spilling gasoline on a hot
engine. Comply with all laws regulating storage and
handling of gasoline.
• Do Not overfill the fuel tank. Always allow room for
fuel expansion. If tank is overfilled, fuel can overflow
onto a hot engine and cause a FIRE or an
EXPLOSION.
• Never store a generator with fuel in the tank where
gasoline vapors might reach an open flame, spark or pilot
light (as on a furnace, water heater, clothes dryer). FIRE
or an EXPLOSION may result.
• The unit requires an adequate flow of cooling air for its
continued proper operation. Never operate the unit
inside any room or enclosure where the free flow of
cooling air into and out of the unit might be obstructed.
Allow at least 2 feet of clearance on all sides of generator,
even while operating unit outdoors, or you could damage
the unit.
• Never start, or stop the unit with electrical loads
connected to receptacles with the connected devices
turned ON. Start the engine and let it stabilize before
connecting any electrical loads. Disconnect all electrical
loads before shutting down the generator.
• Do Not insert any object through cooling slots of the
engine. You could damage the unit or injure yourself.

Figure 1 — Grounding Wing Nut

Grounding Wing Nut

Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.

3

Generac Portable Products 3,500 Watt Generator

KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 15 Amp
Receptacles
Circuit Breakers (AC)

Fuel Tank

Fuel Shut–Off Valve
120/240 Volt AC, 20 Amp
Locking Receptacle
Run/Stop Switch
120 Volt AC, 30 Amp
Locking Receptacle
12 Volt DC, 10 Amp
Receptacle

Grounding Wing Nut
Idle Control Switch
Circuit Breakers (AC) — Each receptacle is provided
with a circuit breaker to protect the generator against
electrical overload. Breakers are "push to reset" type.

12 Volt DC, 10 Amp Receptacle — Use this receptacle
with battery charge cables to charge a 12 Volt battery.
120 Volt AC, 15 Amp Receptacles — May be used to
supply electrical power for the operation of 120 Volt AC,
15 Amp, single phase, 60 Hz electrical lighting, appliance,
tool and motor loads.

Fuel Shut Off Valve — Controls fuel supply to engine.
Fuel Tank — Capacity of 4 U.S. gallons.
Grounding Wing Nut — Provides a tie-point for
connecting the generator frame to earth ground.

120 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.

Idle Control Switch — The idle control runs the engine
at normal (high) speeds when there is a load present and
runs the engine at idle (low) speeds when a load is not
present. This feature greatly improves fuel economy,
extends the life of the engine, and reduces engine noise.

120/240 Volt AC, 20 Amp Locking Receptacle —
May be used to supply electrical power for the operation
of 120 and/or 240 Volt AC, 20 Amp, single phase, 60 Hz
AC electrical lighting, appliance, tool and motor loads.

Run/Stop Switch — Must be in “Run” position to start
engine. Set to “Stop” to stop a running engine.

4

Generac Portable Products 3,500 Watt Generator

BEFORE STARTING THE
ENGINE

• Use regular UNLEADED gasoline with the Generator
engine. Do Not use premium gasoline. Do Not mix oil
with gasoline.
• Clean area around fuel fill cap, remove cap.

Add Oil

• Add unleaded regular gasoline, slowly to fuel tank. Be
careful not to overfill. Allow about 1/2" of tank space for
fuel expansion (Figure 2).

WARNING! Any attempt to crank or start the
engine before it has been properly filled with the
recommended oil may result in an engine failure.

Figure 2 — Fill Tank with Fuel

To fill your engine with oil:
• Place generator on a level surface.
• Clean area around oil fill and remove oil fill cap.
• Select the oil's viscosity grade and fill engine with oil
following the instructions given in the engine owner’s
manual. Do Not overfill!
• Install oil fill cap.
NOTE: The generator’s revolving field rides on a prelubricated and sealed ball bearing that requires no
additional lubrication for the life of the bearing.

• Install fuel cap and wipe up any spilled gasoline.
IMPORTANT: It is important to prevent gum deposits
from forming in essential fuel system parts such as the
carburetor, fuel filter, fuel hose or tank during storage.
Also, experience indicates that alcohol-blended fuels (called
gasohol, ethanol or methanol) can attract moisture which
leads to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine while in
storage.

Add Gasoline
DANGER! Explosion Hazard! Never fill fuel tank
indoors. Never fill fuel tank when engine is running
or hot. Do Not light a cigarette or smoke when
filling the fuel tank.

WARNING! Do Not overfill the fuel tank.

To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. See “Storage”
on page 11. Never use engine or carburetor cleaner
products in the fuel tank or permanent damage may occur.

Always allow room for fuel expansion.

5

Generac Portable Products 3,500 Watt Generator

OPERATING THE
GENERATOR

6.

• If engine fails to start, repeat steps 4 thru 6.
7.

CAUTION! Never start or stop, the engine with
electrical loads connected to the unit and with the
connected devices turned ON.

Disconnect all electrical loads from the generator. Use the
following start instruction steps by numerical order:
Make sure the Idle Control switch is in “Off” position.

2.

Turn the fuel valve to the “On” position.

3.

Set the Run/Stop switch to “Run” position (Figure 3).

Move choke lever to “Run” position. If engine falters,
move choke lever to “Half ” choke position until the
engine runs smoothly and then to “Run” position.

NOTE: If engine still fails to start after 3 pulls, check for
proper oil level in crankcase. This unit is equipped with a
Low Oil Shutdown System. See engine manual.

Starting the Engine
1.

Move the choke lever to “Half” choke position, and
pull recoil handle twice.

Refer to the engine owner’s manual for complete
starting instructions.
• Grasp starter grip and pull slowly until you feel slight
resistance, then pull quickly. Ease the starter rope back
into the engine.

Figure 3 — Run/Stop Switch

• When engine starts, move choke lever to “Run”
position” by sliding it all the way to the right (away from
the valve cover and under the arrow).
NOTE: If engine fails to start after 3 pulls, move the choke
lever to “Half” choke position and pull starter rope again 2
times.
NOTE: If the engine still fails to start, check for proper oil
level in crankcase. Unit is equipped with a low oil
shutdown system. See engine owner’s manual for
information regarding the low oil shutdown system.

4.

Place the choke lever in the “Full” choke position
(Figure 4).

Connecting Electrical Loads

Figure 4 — Choke Lever

• Let engine stabilize and warm up for a few minutes after
starting.

Full Choke
Position

• Plug in and turn on the desired 120 and/or 240 Volt AC,
single phase, 60 Hertz electrical loads.
• Do Not connect 240 Volt loads to 120 Volt receptacles.
• Do Not connect 3–phase loads to the generator.
• Do Not connect 50Hz loads to the generator.

5.

• DO NOT OVERLOAD THE GENERATOR. Add up
the rated watts (or amps) of all loads to be connected at
one time. This total should not be greater than the rated
wattage/amperage capacity of the generator. See “Don’t
Overload the Generator” on page 10.

Grasp the recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly one time only to
start engine.
• If engine starts, proceed to step 7.
• If engine fails to start, proceed to step 6.

6

Generac Portable Products 3,500 Watt Generator

To recharge 12 Volt batteries, proceed as follows:
• Check fluid level in all battery cells. If necessary, add
ONLY distilled water to cover separators in battery cells.
Do Not use tap water.

Stopping the Engine
• Unplug all electrical loads from generator panel
receptacles. Never start or stop engine with electrical
devices plugged in and turned on.

• If the battery is equipped with vent caps, make sure they
are installed and are tight.

• Put the idle control switch in the “Off” position.
• Let engine run at no-load for 30 seconds to stabilize the
internal temperatures of engine and generator.

• If necessary, clean battery terminals.
• Connect battery charge cable connector plug to panel
receptacle identified by the words “12-VOLT D.C.”

• Move run/stop switch to “Stop.”
• Close the fuel shut–off valve.

• Connect battery charge cable clamp with red handle to
the positive (+) battery terminal (Figure 5).

Operating Automatic Idle Control

Figure 5 — Battery Connections

This switch is designed to greatly improve fuel economy.
When this switch is turned ON, the engine will only
run at its normal high governed engine speed when an
electrical load is connected. When an electrical load is
removed, the engine will run at a reduced speed. With
the switch off, the engine will run at the normal high
engine speed. Always have the switch off when
starting and stopping the engine.

Charging a Battery
DANGER! Storage batteries give off explosive
hydrogen gas while recharging. This explosive
mixture will remain around the battery for a long
time after it has been charged. The slightest spark
can ignite the hydrogen and cause an explosion. Such
an explosion can shatter the battery and cause
blindness or other serious injury.

• Connect battery charge cable clamp with black handle
to the negative (–) battery terminal (Figure 5).
• Start engine. Let the engine run while battery recharges.

DANGER! Do Not permit smoking, open flame,

• When battery has charged, shut down engine

sparks or any other source of heat around a battery.
Wear protective goggles, rubber apron and rubber
gloves when working around a battery. Battery
electrolyte fluid is an extremely caustic sulfuric acid
solution that can cause severe burns. If spill occurs,
flush area with clear water immediately.
Your generator has the capability of recharging a discharged
12 Volt automotive or utility style storage battery. Do Not
use the unit to charge any 6 Volt batteries. Do Not use
the unit to crank an engine having a discharged battery.

NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer’s instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific
gravity of its fluid (as measured by hydrometer) is 1.260 or
higher.

7

Generac Portable Products 3,500 Watt Generator

COLD WEATHER
OPERATION

• Ensure a minimum of two feet clearance between open
side of box and nearest object.

Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your Generac generator
may experience icing of the carburetor and/or the
crankcase breather system.

• Enclosure should hold enough heat created by the
generator to prevent icing problems.

• Face exposed end away from wind and elements.

CAUTION! Never run unit indoors; Do Not
enclose generator any more than shown. Remove
shelter when temperatures are above 40°F [4°C].

In an emergency, use the original shipping box as a
temporary shelter:
• Cut off all flaps.

RECEPTACLES

• Cut out one of the long sides of the box to expose
exhaust side of unit. Ensure a minimum of two feet
clearance between open side of box and nearest object.

120 Volt AC, 15 Amp Receptacles
Each of these outlets is protected against overload by
15 Amp push-to-reset circuit breakers (Figure 7).

• Cut appropriate slots to access receptacles of unit. You
may also need to cut a clearance slot for the handle.

Figure 7 — 120 Volt, 15 Amp Receptacles

• Start unit, then place box over it.
IMPORTANT: Remove shelter when temperature is
above 40°F [4°C].
For a more permanent shelter, build a structure that will
enclose three sides and the top of the generator:
• Make sure entire muffler-side of generator is exposed. A
typical shelter is shown in Figure 6.
Figure 6 — Temporary Cold Weather Shelter

Wind
Use each outlet to operate 120 Volt AC, 60 Hz, single
phase loads requiring 1,800 (1.8 kW) watts at 15 Amps of
current.

8

Generac Portable Products 3,500 Watt Generator

120/240 Volt AC, 20 Amp Locking
Receptacle

120 Volt AC, 30 Amp Locking
Receptacle

Use a NEMA L14-20 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volts AC at 30 Amps (or
greater) (Figure 8). You can use the same 4-wire cord if
you plan to run a 120 Volt load.

Use a NEMA L5-30 plug with this receptacle. Connect a 3wire cord set rated for 125 Volts AC at 30 Amps to the
plug (Figure 9).
Figure 9 — 120 Volt, 30 Amp Locking Receptacle

Figure 8 — 120/240 Volt, 20 Amp Locking Receptacle

Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,500 watts (3.5 kW) of power
at 29.2 Amps. The outlet is protected by a push-to-reset
circuit breaker.

This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 2,400 watts of power at
20 Amps for 120 Volts OR 3,500 watts of power (3.5 kW)
at 14.6 Amps for 240 Volts. The outlet is protected by a
push-to-reset circuit breaker.

CAUTION! Although this outlet states it has a
120 Volt, 30 Amp rating (up to 3,600 watts), the
generator is only rated for 3,500 watts. Powering
loads that exceed the wattage/amperage capacity of
the generator can damage it or cause serious
injuries. Loads of 120 Volts powered through this
outlet should not exceed 29.2 Amps of current.

9

Generac Portable Products 3,500 Watt Generator

DON’T OVERLOAD THE
GENERATOR

• If the appliance, tool or motor does not give wattage,
multiply 120 Volts times ampere rating to determine
watts (volts x amps = watts).
• Some electric motors, such as induction types, require
about three times more watts of power for starting than
for running. This surge of power lasts for only a few
seconds when starting such motors. Be sure you allow
for this high starting wattage when selecting electrical
devices to connect to your generator. First figure the
watts needed to start the largest motor. Add to that
figure the running watts of all other connected loads.

Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and/or
connected electrical devices. Observe the following, to
prevent overloading the unit:
• Add up the total wattage of all electrical devices to be
connected at one time. This total should NOT be
greater than the generator’s wattage capacity.
• The rated wattage of lights can be taken from light bulbs.
The rated wattage of tools, appliances and motors can
usually be found on a data plate or decal affixed to the
device.

• Items in the wattage reference guide (Figure 10) are
provided to help you to determine how many items the
generator can operate at one time.

Figure 10 — Wattage Reference Guide

Professional/Contractor Uses
Tool/Appliance....................................................Watts
*1/3 hp airless sprayer.............................................................600
3/8" hammer drill .....................................................................600
Variable speed Sawzall®..........................................................960
½" power drill.........................................................................1000
Quartz-halogen work light...................................................1000
Belt sander...............................................................................1200
7 ¼" circular saw ...................................................................1500
7 ¼" worm drive saw............................................................1600
*1½ hp air compressor ........................................................1800
*10" power miter saw...........................................................1800
6" bench grinder.....................................................................1800
*6" table planer.......................................................................1800
*10" table/radial arm saw .....................................................2000
Wire feed welder...................................................................2400
* allow 3 times listed watts for starting this device

Recreational/Home Uses
Tool/Appliance....................................................Watts
AM/FM clock radio.....................................................................50
Light bulb....................................................................................100
Fan................................................................................................200
20" color TV..............................................................................400
*Deep freezer............................................................................500
Personal computer and 15" monitor ...................................800
*1/3 hp furnace fan blower.....................................................800
Microwave oven........................................................................800
*18 cu ft refrigerator ...............................................................800
Sump pump..............................................................................1000
Electric skillet..........................................................................1250
*½ hp water well pump........................................................1400
*12,000 Btu window air conditioner .................................1400
Space heater............................................................................1800
Electric water heater.............................................................4000

10

Generac Portable Products 3,500 Watt Generator

SPECIFICATIONS

To Clean the Generator

Maximum Surge Watts . . . . . . . . .
Continuous Wattage Capacity . . .
Power Factor . . . . . . . . . . . . . . . .
Rated Maximum Continuous Load
At 120 Volts . . . . . . . . . . . . . .
At 240 Volts . . . . . . . . . . . . . .
Phase . . . . . . . . . . . . . . . . . . . . . .
Rated Frequency . . . . . . . . . . . . .
Fuel Tank Capacity . . . . . . . . . . . .

• Use a damp cloth to wipe exterior surfaces clean.

. . . . .4,375 watts
. . . . .3,500 watts
. . . . .1.0
.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

• Soft, bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.

.29.2 Amps
.14.6 Amps
.1 phase
.60 Hertz
.4 U.S. gallons

• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.

STORAGE INSTRUCTIONS

GENERAL MAINTENANCE
RECOMMENDATIONS

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30
days, use the following guidelines to prepare it for storage.

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.

Generator Storage
• Clean the generator as outlined in “To Clean the
Generator.”

Engine Maintenance

• Check that cooling air slots and openings on generator
are open and unobstructed.

See engine manual for instructions.

DANGER! Storage covers can be flammable. Do
Not place a storage cover over a hot generator. Let
the unit cool for a sufficient time before placing the
cover on the unit.

Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

Engine Storage
See engine owner’s manual for instructions.

Other Storage Tips

NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. Water
and dirt buildup on the generator internal windings will
eventually decrease the insulation resistance of these
windings.

• Do Not store gasoline from one season to another.
• Replace your gasoline can if it starts to rust. Rust and/or
dirt in a gasoline can cause problems when you use
contaminated fuel with this unit.
• Store in clean and dry area.

11

Generac Portable Products 3,500 Watt Generator

TROUBLESHOOTING
Problem
Engine is running, but no AC
output is available.

Engine runs good but bogs
down when loads are
connected.

Engine will not start; or starts
and runs rough.

Engine shuts down during
operation.

Engine lacks power.

Engine "hunts" or falters.

Cause

Solution

1.
2.

1.
2.

Reset circuit breaker.
Check and repair.

3.

Circuit breaker is open.
Poor connection or defective
cord set.
Connected device is bad.

3.

4.
1.
2.

Fault in generator.
Short circuit in a connected load.
Generator is overloaded.

4.
1.
2.

Engine speed is too slow.
Shorted generator circuit.
Run/Stop switch set to "Stop".
Dirty air cleaner.
Out of gasoline.
Stale gasoline.
Spark plug wire not connected to
spark plug.
6. Bad spark plug.
7. Water in gasoline.
8. Overchoking.
9. Low oil level.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Out of gasoline.
2. Low oil level.
3. Fault in engine.
1. Load is too high.

3.
4.
1.
2.
3.
4.
5.

Connect another device that is in good
condition.
Contact Generac service facility.
Disconnect shorted electrical load.
See "Don't Overload the Generator" on
page 10.
Contact Generac service facility.
Contact Generac service facility.
Set switch to "Run".
Clean or replace air cleaner.
Fill fuel tank.
Drain gas tank and fill with fresh fuel.
Connect wire to spark plug.

2.
3.
1.

Dirty air filter.
Engine needs to be serviced.
Choke is opened too soon.

2.
3.
1.

2.

Carburetor is running too rich or
too lean.

2.

3.
4.
1.
2.
3.
4.
5.

12

6.
7.
8.
9.
10.
11.
12.
1.
2.
3.
1.

Replace spark plug.
Drain gas tank; fill with fresh fuel.
Put choke lever to "no choke" position.
Fill crankcase to proper level.
Contact Generac service facility.
Contact Generac service facility.
Contact Generac service facility.
Fill fuel tank.
Fill crankcase to proper level.
Contact Generac service facility.
See "Don't Overload the Generator" on
page 10.
Replace air filter.
Contact Generac service facility.
Move choke to halfway position till
engine runs smoothly.
Contact Generac service facility.

Generac Portable Products 3,500 Watt Generator

NOTES

13

Generac Portable Products 3,500 Watt Generator

SCHEMATIC DIAGRAM

14

Generac Portable Products 3,500 Watt Generator

WIRING DIAGRAM

15

Generac Portable Products 3,500 Watt Generator

EXPLODED VIEW – MAIN UNIT

16

Generac Portable Products 3,500 Watt Generator

PARTS LIST – MAIN UNIT
Item
1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
25
26
27
30
32
33
34
35
36
37

Part #
93199
84021
NSP
66365
84141
83540
65791
67451
86307
47480
84508
52858
83208
B4986
66476
89476
70644
84346
40976
83083
83071
81917
66825B
85652
67989
74908
86308
65795
66849A
67022
84132
66386

Qty.
1
1
1
1
1
1
1
1
4
1
2
8
1
1
2
1
1
3
2
1
1
1
1
2
2
4
4
1
1
1
1
1

Description
CRADLE, XL
SUPPORT, Engine
ENGINE, 6.5 HP XL
HOUSING, Engine Adapter
ASSEMBLY, Rotor
ASSEMBLY, Stator
BEARING
WASHER, M8 Flat
SCREW, 5/16-24 x 3/4
SCREW, 5/16-24 x 7" Cap
MOUNT, 45º Vibration
NUT, M8 Locking
BRACKET, Muffler
DECAL, Ground
SCREW, M6 - 1.0 x 12
GASKET, Exhaust
SCREW, M8-1.25 x 20 PPHM
SCREW, M8 x 35 PPHM
SCREW, M8 - 1.25 x 20
SCREEN, Spark Arrest
MUFFLER
PIN, M4 x 10 Roll
CARRIER, Rear Bearing
MOUNT, Vibration
NUT, M8 Flanged Serrated
TAPTITE, M5-8.0 x 10
BOLT, M6-1.0 x 115 Stator
RECTIFIER, Battery Charge
M5-0.8 x 20 Taptite
GROMMET, Rubber
MODULE, Drive
ASSEMBLY, Brush Holder

Item
38
39
41
42
43
44
46
47
48
49
50
51
52
53
54
55
56
60
61
62
64
66
67
68
69

Part # Qty. Description
66849
2
TAPTITE, M5-0.8 x 16
B4871
1
COVER, Bearing Carrier
86494
1
SCREW, M6-1.0 x 16mm Wing
86292
1
SCREW, 10-16 x 3/4" Self Drill
77395
4
NUT, M6 Flange Lock
83465
4
GROMMET, Tank
78831B
4
SCREW, M6-1.0 x 60 (black)
80270
1
VALVE, Tank
78299
1
BUSHING, Plastic Tank
85134
1
GUAGE, Fuel Cap
88325
1
TANK, Fuel
84042
1
SHIELD, Heat
84687
1
INSULATION, #2 1/4"
85000
1
CLIP, Insulation
14353621 1
WIRE, Ground
23762
1
WASHER, #10 Shakeproof
26850
2
WASHER, M6 Shakeproof
84679
1
DECAL, Control Panel
92982
1
DECAL, Danger
84678
2
DECAL, Heat Shield
87116
1
ASSY., Control Panel
93826
1
DECAL, Start Instruction
73054
1
DECAL, Fuel Shut-Off
B2153
4
HHCS, 12 - 14 x 7/8" Self Drill
84409
1
SLEEVING, Flexo HW 1/2" x .83
ft.

Accessories Not Illustrated:
65787
1
Battery Charge Cables
43483
1
120/240 Volt 20 Amp Plug
37806
1
120 Volt 30 Amp Plug

17

Generac Portable Products 3,500 Watt Generator

EXPLODED VIEW/PARTS LIST – CONTROL PANEL

Item
1
2
3
4
5

Part #
83976
83975
66818
66821
68867C

Qty.
1
1
2
1
1

6

68868C

1

7
8
9
10
11
12

75207A
75207G
82538
84134
83514
83970

1
2
1
1
1
1

Item
13
14
15
16
17
18
19
21
22
23
24
25
26

Description
PANEL, Control
BOX, Control
OUTLET, 120 Volts AC
OUTLET, 12 Volts DC
OUTLET, 120/240 Volts, 20 Amp
Locking
OUTLET, 120 Volts, 30 Amp
Locking
CIRCUIT BREAKER, 30 Amp
CIRCUIT BREAKER, 18 Amp
SWITCH, On/Off Rocker
GROMMET, Rubber
CIRCUIT BREAKER, 10 Amp
CONTROL BOARD, System

18

Part #
84028
67022
85584
84543A
84543C
84198
84197
75476
22264
51715
84543B
84335
82542

Qty.
1
1
1
2
9
3
1
2
4
4
10
1
1

Description
TRANSFORMER, Idle Control
GROMMET, Rubber
BAR, Bus
SCREW, 3.0 x 12mm
SCREW, 3.5 x 18mm
SHIELD, Circuit Breaker
BAR, Circuit Breaker Retaining
SCREW, 4.15 x 16mm
WASHER, M4 Lock
NUT, M3 Hex
SCREW, 3.5 x 12mm
WIRE HARNESS
BAR, DC Outlet Retaining

Generac Portable Products 3,500 Watt Generator

NOTES

19

LIMITED WARRANTY
FOR "GN" ENGINE DRIVEN PORTABLE GENERATORS
GENERAC PORTABLE PRODUCTS (hereafter referred to as the COMPANY) warrants to the original purchaser that the
alternator and control panel for its portable generator will be free from defects in materials or workmanship for the items
and period set forth below from the date of original purchase. This warranty is not transferable and applies only to
portable generators driven by a GN-Series engine.
Alternator
Engine

Consumer*
Commercial*
2 years (2nd year parts only)
1 year
Warranted solely by the engine manufacturer

With the exception of European Community Countries, all units bound for export shall be warranted for One (1)
Year in Consumer applications, and 90 days in Commercial applications as defined below.
*NOTE: For the purpose of this warranty "consumer use" means personal residential household use by
original purchaser. This warranty does not apply to units used for Prime Power in place of utility.
"Commercial Use" means all other uses, including rental, construction, commercial and income producing
purposes. Once a generator has experienced commercial use, it shall thereafter be considered a
commercial use generator for the purposes of this warranty.
During said warranty period, the COMPANY will, at is option, repair or replace any part which, upon examination by the
COMPANY, is found to be defective under normal use and service**. Starting batteries are not warranted by the
COMPANY. All transportation costs under warranty, including return to the factory if necessary, are to be borne by the
purchaser and prepaid by the purchaser. This warranty does not cover normal maintenance and service and does not apply
to a generator set, alternator, or parts which have been subjected to improper or unauthorized installation or alteration,
misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in the
COMPANY’s judgement, to adversely affect its performance and reliability.
**NORMAL WEAR: As with all mechanical devices, the generator need periodic parts service and
replacement to perform well. This warranty will not cover repair when normal use has exhausted the life of
a part or generator.
THERE IS NO OTHER EXPRESS WARRANTY. THE COMPANY HEREBY DISCLAIMS ANY AND ALL
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW. THE DURATION OF
ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS
SPECIFIED IN THE EXPRESS WARRANTY. LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL
DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED. THE COMPANY ALSO DISCLAIMS
ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, SUCH AS THE LOSS OF
TIME OR THE USE OF THE POWER EQUIPMENT, OR ANY COMMERCIAL LOSS DUE TO THE FAILURE
OF THE EQUIPMENT: AND ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS
WRITTEN WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal
rights and you may also have other rights, which vary from state to state.
For service, see your nearest COMPANY authorized warranty service facility or call 1-877-544-0982. Warranty service
can be performed only by a COMPANY authorized service facility. This warranty will not apply to service at any other
facility. At the time of requesting warranty service, evidence of original purchase date must be presented.

GENERAC PORTABLE PRODUCTS
Jefferson, Wisconsin U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : Provided By MANUALSLIB.COM - http://www.manualslib.com/
Create Date                     : 2014:08:01 10:04:56Z
Keywords                        : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides
Modify Date                     : 2016:04:28 16:47:51-07:00
Subject                         : Search through 700.000 manuals online & and download pdf manuals.
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : Provided By MANUALSLIB.COM - http://www.manualslib.com/
Description                     : Search through 700.000 manuals online & and download pdf manuals.
Title                           : ManualsLib - Makes it easy to find manuals online!
Creator Tool                    : pdftk 1.44 - www.pdftk.com
Metadata Date                   : 2016:04:28 16:47:51-07:00
Producer                        : itext-paulo-155 (itextpdf.sf.net-lowagie.com)
Document ID                     : uuid:bf2808aa-2440-cc4f-bae8-65eb1c84f030
Instance ID                     : uuid:261a15c2-225d-124c-835e-02581c47329a
Page Count                      : 20
EXIF Metadata provided by EXIF.tools

Navigation menu