GENPortable Products
RAC°I

Portable

Generator

Model No. 1311_0 (3000 Watt AC Generator)
Visit our

Generac

website:

Owner's Manual

Manual No. B4345 Revision 2 (07/09/2001)

www.generac-portables.com

_This that follow
is the safety
alert symbol.
is used injury
to alert
to potential personal injury hazards.Obey all safety messages
this symbol
to avoidItpossible
oryou
death.

Generac Portable Products 3000 Watt Generator

SAFETY

EQUIPMENT
DESCRIPTION

RULES

This generator set was designed and manufactured for
specific applications. Do Not attempt to modify the unit
or use it for any application it was not designed for. If you
haveany questions about your generator's application, ask
your dealer or consult the factory.

This generator is an engine-driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances,tools and motor loads. This manual
contains informationfor a generator that operates
120 Volt, single phase, 60 Hz devices that require up to
3,000 watts (3.0 kW) of power that pull up to 25 Amps.

The manufacturer could not possibly anticipate every
circumstance that might involvea hazard. For that reason
warnings in the manual and warnings on tags or decals
affixed to the unit are not all-inclusive. If you intend to
handle, operate or service the unit by a procedure or
method not specifically recommended by the manufacturer,
first make sure that such a procedure or method will not
render this equipment unsafe or pose a threat to you and

CAUTION!
Do Not exceed the generator's
wattage/amperage capacity. Add up the rated watts of all
devices you are connecting to generator receptacles at one
time. This total should not be greater than 3,000 watts. In
most cases rated watts of the electrical device can be

others.

found on the device nameplate. If the device nameplate
gives only volts and amps, multiply volts times amps to
obtain watts (volts X amps = watts).

Read this manual carefully and become familiar
with your generator set. Know its applications, its
limitations and any hazards involved.

The 3,000 watt portable generator hasthe following
features:

• 120 Volt, 20 Amp duplex receptacle.
• Low Oit Shutdown: Automatically shuts down the engine
if oil drops below safe operation level.
• The generator's revolving field is driven at about
3600 rpm by a Tecumseh 6 h.p. engine.

_

CAUTION!speed.Do
Notoperating
tamper speeds
with engine
governed
High
are
dangerous and increaserisk of personal injury or
damageto equipment. The generator supplies
correct rated frequency and voltage onty when
running at proper governed speed. Incorrect
frequency and/or voltage can damage some
connected electrical loads.Operating at excessively
low speeds imposesa heavy load. When adequate
engine power is not availableengine life may be
shortened.

_

WARNING!
must
isolatethe
from the electricYou
utility
using
approvedgenerator
transfer
equipment if this unit is used for backup power.
Failure to isolate the generator from the
power utility may result in injury or death to
electric utility workers and damage to the
generator due to a backfeed of electrical energy.
Whenever the unit is providing backup power, the
electric utility must be notified.

_hL

DANGER!
Generator
exhaustgas.
gases
contain
DEADLY
carbon
monoxide
If breathed
sufficient concentrations,
carbon monoxide

in

can cause unconsciousness
or death. Operate
this equipment outdoors where adequate ventilation
is available.

The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency. For warranty informationrefer to the
engine owner's manual.

I
2

Generac Portable Products 3000 Watt Generator

• The generator produces a very powerful voltage that can
cause serious injury or death by electrocution. Never
touch bare wires or receptacles. Never permit a child
or any unqualified person to operate the generator.

• Never operate the generator:
in rain; in any enclosedcompartment; when connected
electrical devices overheat; if electrical output is lost; if
engine or generator sparks; if flame or smoke is
observed while unit is running; if unit vibrates
excessively.

• Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet
are wet Death or serious injury from electrocution may
result.

GROUNDING
THE
G EN ERATO R

• Use a ground fault circuit interrupter (GFCI) in any damp
or highly conductive area (such as metal decking or steel
work).

The National ElectricalCode requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure I).

• Never use worn, bare, frayed or otherwise damaged
electrical cords with the generator. Death, serious injury
and property damage from electrical shock may result.
• Gasoline is highly FLAMMABLE and its vapors
are EXPLOSIVE. Never allow smoking, open
flames, sparks or heat in the vicinity while
handling gasoline. Avoid spilling gasoline on a hot
engine. Comply with all laws regulating storage and
handling of gasoline.
• Do Not overfill the fuel tank. Always allow room for
fuel expansion. If tank is overfllled, fuel can overflow
onto a hot engine and cause a FIRE or an
EXPLOSION.
• Never store a generator with fuel in the tank where
gasoline vapors might reach an open flame, spark or pilot
light (as on a furnace, water heater, clothes dryer). FIRE
or an EXPLOSION may result.
• The unit requires an adequateflow of cooling air for its
continued proper operation. Never operate the unit
insideany room or enclosure where the free flow of
cooling air into and out of the unit might be obstructed.
Allow at least 2 feet of clearance on all sides of generator,
even while operating unit outdoors, or you could damage
the unit

Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.

• Never start, or stop the unit with electrical loads
connected to receptacles with the connected devices
turned ON. Start the engine and let it stabilize before
connecting any electrical loads. Disconnect all electrical
loads before shutting down the generator.

Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.

• Do Not insertany object through cooling slots of the
engine.You could damagethe unit or injureyourself.

/

3

Generac
Portable
Products
3000WattGenerator

KNOW

YOUR

GENERATOR

Reacl this owner's manual and safety rules before operating your generator.
Compare the illustrationswith your generator to familiarize yourself with the locationsof various controls and
adjustments. Savethis manual for future reference.

Oil Fill Tube

Fuel Tank

Primer

120 Volt AC, 20 Amp,
Duplex Receptacle

Circuit

Breakers (AC)

120 Volt AC, 20 Amp, Duplex Receptacle -- May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.

Grounding Wing Nut

Fuel Tank -- Fill tank with regular unleadedgasoline only.
Grounding Wing Nut -- Provides a tie-point for
connecting the generator frame to earth ground.
Oil Fill Tube -- Fill engine with oil here. See engine
owners manual for oil recommendations.

Circuit Breakers (AC) -- Each receptacle is provided
with a circuit breaker to protect the generator against
electrical overload. Breakers are "push to reset" type.

Primer -- Use to start a cold engine. Review the engine
owner's manual for specific instructions.

/

4

Generac
Portable
Products
3000WattGenerator

BEFORE STARTING
ENGINE

THE

• Clean area around fuel fill cap, remove cap.
• Slowly add unleaded regular gasoline to fuel tank. Be
careful not to overfill. Allow tank space for fuel
e> ,anslon,as shown in Figure 2.

Add Oil
CAUTION!
Any attempt to crank or start the engine
before it has been properly filled with the recommended
oil may result in an engine failure.
To fill your engine
• Place generator

with

1/2" Air Space

Tank

oil:

on a level surface.

• Clean area around oil fill and remove oil fill cap.
• Select the oil's viscosity grade and fill engine with oil
following the instructions given in the engine owner's
manual. Do Not overfill!
• Install oil fill cap.

• Install fuel cap and wipe up any spilled gasoline.

NOTE: The generator's revolving field rides on a prelubricated and sealed ball bearing that requires no
additional lubrication for the life of the bearing.

IMPORTANT:
It is important to prevent gum deposits
from forming in essential fuel system parts such as the
carburetor, fuel filter, fuel hose or tank during storage.
Also, experience indicates that alcohol-blended fuels (called
gasohol, ethanol or methanol) can attract moisture which
leads to separation and formation of acids during storage.
Acidic fuel can damage the fuel system of an engine while
in storage.

Add Gasoline
_hL

ARNING!
Never
tank or
indoors.
Never
fill fuel
tank when
enginefillisfuel
running
hot. Allow
unit to cool for two minutes before refueling. Do
Not light a cigarette or smoke when filling the fuel
tank.

To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. See "Storage"
on page 9. Never use engine or carburetor cleaner
products

_hL

WARNING!
Do for
Notfuel
overfill
the fuel tank.
Always
allow room
expansion.

• Use regular UNLEADED
gasoline with the generator
engine. Do Not use premium gasoline. Do Not mix oil
with gasoline.

/

5

in the fuel tank or permanent

damage may occur.

Generac Portable Products 3000 Watt Generator

OPERATING
THE
GENERATOR

For temperatures

Temporary
_

above 32°F (0°C),

Follow above instructions,removing baffle from "winter"
position and reinstalling in "summer" position.
Weather

Shelter

You can use the original shipping box as a temporary
shelter for extremely cold weather:

CAUTION!
startto orthe
stop
the unit with
electrical
loads Never
connected
receptacles
AND
with the connected devices turned ON.

• Cut off alt flaps

Cold Weather

Operation

• Cut out one of the long sides of the box to expose
exhaust side of unit. Ensure a minimum of two feet
clearance between open side of box and nearest object

The engine is equipped with an anti-icing air cleaner which
enables the engine to run at temperatures below 32°F
(O°C), without ice forming in the carburetor.

• Cut appropriate slots to accessreceptacles of unit.

The air cleaner base has an opening which draws warm air
from the muffler into the air cleaner housing. To work
effectively, it is necessary to block cold air from entering
the air cleaner.
For temperatures

• Start unit, then place box over it.
IMPORTANT: Remove shelter when temperature is
above 40°F [4°C].
For a more permanent shelter, build a structure that will
enclose three sides and the top of the generator:

below, 32°F (O°C),

• Make sure entire muffler-side of generator is exposed, as
shown in Figure 4.

• Remove the wing nut on the air cleaner cover.
• Remove the air cleaner cover from base.
• Remove baffle from insideof air cleaner cover.
• Insert baffle in "winter" position, as shown in Figure 3.

7

Paper Element
Base S

Baffle Shown In
"Winter" Position

Wing Nut

l
• Ensure a minimum of two feet clearance between open
side of box and nearest object.

/

IID i

_II P°sIC_
"_

• Face exposed end away from wind and elements.

AirClea!!rCover

• Enclosureshould holdenough heatcreatedby the
generatorto preventproblems.

Reinstall
aircleanercover onto base.
• Reinstall wing nut, tighten securely.

i

6

Generac Portable Products 3000 Watt Generator

Starting
,_

the Engine

Stopping the Engine
• Unplug all electrical loads from generator panel
receptacles. Never start or stop engine with electrical
devices plugged in and turned on.

WARNING!
runareas.
engineEngine
indoors
or in
enclosed poorly Never
ventilated
exhaust
contains carbon monoxide, an odorless and deadly
gas.

• Let engine run at no-load for several minutes to stabilize
the internal temperatures of engine and generator.
• Move engine control switch to "Stop."

_

CAUTION!
Temperature
of muffler
nearby
areas may exceed
150°F(65°C).
Avoid and
these
areas.

RECEPTACLES

• Unplug all electrical loads from generator receptacles
before starting the engine.
• Make sure the unit is in a level position.

120 Volt,

• Set the engine control switch to "Start."

Eachof these receptacles is protected against overload by
push-to-reset type circuit breakers. Use each receptacle to
operate 120 Volt, 60 Hz, single phase loads at 20 Amps of
current (Figure 5).

• Press primer three (3) times wait about two (2) seconds
between each push. In cold weather (50°F/10°C or
below) push five (5) times.

20 Amp

Receptacles

• Grasp starter grip and pull slowly until you feel some
resistance. Then pull cord out with rapid full arm stroke.
Let rope return slowly. Do Not let rope "snap back"
against starter.
NOTE: If engine fails to start after three (3) pulls, press
primer two (2) times and pull starter rope again.

Connecting

Electrical

Loads

• Let engine stabilize and warm up for a few minutes after
starting.
• Plug in and turn on the desired 120 Volt AC, single
phase, 60 Hz electrical loads.
• Do Not connect 240 Volt loads to the generator.
• Do Not connect 3-phase loads to the generator.
,_

• Do Not connect 50 Hz loads to the generators.
• DO NOT OVERLOAD THE GENERATOR. Add up
the rated watts (or amps) of alt loads to be connected at
one time. This total should not be greater than the rated
wattage/amperage capacity of the generator. See "Don't
Overload the Generator" on page 8.

/
7

CAUTION!
outletwatts),
has a the
rating of
120Volts at 20 Although
Amps (upeach
to 4,800
generator is only rated for 3,000 Watts. Powering
loads that exceed the wattage/amperage capacity of
the generator can damageit or cause serious
injuries.

Generac Portable Products 3000 Watt Generator

DON'T OVERLOAD
G EN ERATO R

THE

• If the appliance, tool or motor does not give wattage,
multiply 120 Volts times ampere rating to determine
watts (volts x amps = watts).
• Some electric motors, such as induction types, require
about three times more watts of power for starting than
for running. This surge of power lasts for only a few
seconds when starting such motors. Be sure you allow
for this high starting wattage when selecting electrical
devices to connect to your generator. First figure the
watts needed to start the largest motor. Add to that
figure the running watts of all other connected loads.

Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and/or
connected electrical devices. Observe the following to
prevent overloading the unit:
• Add up the total wattage of all electrical devices to be
connected at one time. This total should NOT be
greater than the generator's wattage capacity.
• The rated wattage of lights can be taken from light bulbs.
The rated wattage of tools, appliances and motors can
usually be found on a data plate or decal affixed to the
device.

• Items in the wattage reference guide (Figure 6) are
provided to help you determine how many items the
generator can operate at one time.

Recreational/Home Uses
Tool/Appliance ............................................................
Watts
AM/FM clock radio .................................................................
50
Lightbulb................................................................................
100
Fan...........................................................................................
200
20" color TV..........................................................................
400
*Deep freezer .......................................................................
500
Personal computer and 15" monitor ...............................
800
"1/3 hp furnace fan blower ................................................
800
Microwave oven....................................................................
800
"18 cu ft refrigerator ...........................................................
800
Sump pump..........................................................................
1000
Electric skillet ......................................................................
1250
*/2 hp water welt pump....................................................
1400
* 12,000 Btu window air conditioner .............................
1400
Spaceheater ........................................................................
1800
Electric water heater ........................................................
4000

/

8

Professional/Contractor Uses
Tool/Appliance ............................................................
Watts
* 1/3 hp airless sprayer.........................................................
600
3/8" hammer drill .................................................................
600
Variable speed Sawzalt®.....................................................
960
Y2"power drill ....................................................................
1000
Quartz-halogen work light...............................................
1000
Belt sander...........................................................................
1200
7 ¼" circular saw ...............................................................
1500
7 ¼" worm drive saw........................................................
1600
* I '/2 hp air compressor ....................................................
1800
*10" power miter saw.......................................................
1800
6" bench grinder .................................................................
1800
*6" table planer ...................................................................
1800
* I 0" table/radial arm saw .................................................
2000
Wire feed welder ...............................................................
2400
*=allow 3 times listedwatts for starting surge

Generac
Portable
Products
3000WattGenerator

GENERAL
MAINTENANCE
RECOMMENDATIONS

• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspectcooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.

The owner/operator is responsible for making sure that all
periodic maintenance tasks are completed on a timely
basis; that alt discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.

Engine

STORAGE

The generator should be started at least once every seven
days and allowed to run at least30 minutes. If this cannot
be done and you must store the unit for more than 30
days, use the following guidelines to prepare it for storage.

Maintenance

See engine owner's manual for instructions.

_hL

Generator

• Check that cooling air slots and openings on generator
are open and unobstructed.

laboratory animals. Thoroughly wash exposed areas
with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.

_

CAUTION!
Storage
Do
Not place a
storagecovers
cover can
overbeaflammable.
hot
generator. Let the unit cool for a sufficient time
before placing the cover on the unit.

Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it witl not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

Engine

Storage

See engine

owner's

Other

Storage

• Do

Not

• Replace

NOTE: Generac Does Not recommend using a garden
hose to clean generator. Water can enter engine fuel
system and cause problems. In addition, if water enters
generator through cooling air slots, some of the water witl
be retained in voids and cracks of the rotor and stator
winding insulation. Water and dirt buildup on the
generator internal windings witl eventually decrease the
insulationresistance of these windings.

To Clean

Storage

• Clean the generator as outlined in "To Clean the
Generator."

AUTION!
Avoid
prolonged
or motor
repeated
contact
with used
motor
oil. Used
oit skin
has
been shown to cause skin cancer in certain

Generator

INSTRUCTIONS

manual

from

one season

can if it starts

in gasoline can cause
with this unit.
• Store

Tips

store gasoline
gaso{ine

for instructions.

in clean and dry

problems

to

to another.

rust- Rust

when

that

and/or

dirt

fuel is used

area.

SPECIFICATIONS

the Generator

• Use a damp cloth to wipe exterior surfaces clean.

Maximum Surge Watts .................

3,750 watts

Continuous Wattage Capacity ...........
Power Factor ..............................

3,000 watts
1.0

Rated Maximum Continuous

• Soft, bristle brush may be used to loosen caked on dirt
or oil.

Load Current at 120 Volts ................
Phase .................................

• A vacuum cleaner may be used to pick up loose dirt and
debris.

Rated Frequency .......................
Shipping Weight ..........................

/
9

25 Amps
I -phase
60 Hertz
85 lbs.

/

Generac Portable Products 3000 Watt Generator

NOTES

/
I0

Generac Portable Products 3000 Watt Generator

TROUBLESHOOTING
Problem

Cause

Solution

Engine is running,
but no AC output is
available.

I.
2.
3.

Circuit breaker is open.
Poor connection or defective cord set.
Connected device is bad.

I.
2.
3.

Reset circuit breaker.
Check and repair.
Connect another device that is in good
condition.

4.
I.
2.

Fault in generator.
Short circuit in a connected load.
Generator is overloaded.

4.
I.
2.

Contact Generac service facility.
Disconnect shorted eiectricaiload.
See "Don't Overload the Generator" on

3.
4.
I.
2.
3.
4.
5.

Enginespeed is too stow.
Shorted generator circuit.
On/Off switch set to "Stop."
Dirty air cleaner.
Out of gasoline.
Stalegasoline.
Spark plug wire not connected to
spark plug.
Bad spark plug.
Water in gasoline.
Low oil level

3.
4.
I.
2.
3.
4.
5.

page 8.
Contact Generacservice facliity.
Contact Generac service facility.
Set switch to "Start."
Clean or replace air cleaner.
Fill fuel tank.
Drain gas tank and fill with fresh fuel.
Connect wire to spark plug.

6.
7.
8.
9.
10.
I I.
I.

Replace spark plug.
Drain gas tank; fill with fresh fuel.
Fill crankcase to proper level.
Contact Tecumseh service facility.
Contact Tecumseh service facility.
Contact Tecumseh service facility.
Fill fuel tank.

Engine runs good
but bogs down when
loads are connected.

Engine will not start;
or starts and runs
rough.

6.
7.
8.

9. Excessively rich fuel mixture.
10. Intake valve stuck open or closed.
I I. Engine has lost compression.
Engine shuts down
during operation.

I.
2.

Out of gasoline.
Low oil level.

Engine

3.
I.

Fault in engine.
Load is too high.

2.
3.

Dirty air filter.
Engineneeds to be serviced.

Engine
falters.

lacks power.

"hunts"

or

Carburetor

2.
3.
I.

is running too rich or too lean.

i
II

Fill crankcaseto proper level.
ContactTecumseh service facility.
See "Don't Overload the Generator" on
page 8.
2. Replace air filter.
3. ContactTecumseh service facility.
Contact Tecumseh service facility.

/

Generac Portable Products 3000 Watt Generator

NOTES

/
12

Generac Portable Products 3000 Watt Generator

ELECTRICAL

SCHEMATIC/WIRING

m

DIAGRAM

W

+
_l::q
_z
D_W
W_
_l:za

_L_
[32q

-8_,,
WL

no

/

13

>_

I

Generac Portable Products 3000 Watt Generator

l/|

1-@
2J

']_

LvB
EXPLODED

VIEW

46

\
4S

33,
\\

/

48

13
14

34

11
16

19

3O
25-

38

/
31

36

/
14

51

Generac Portable Products 3000 Watt Generator

PARTS LIST
Item
I
2
3
4
5
6
7
9
10

Part #
Qty.
NSP
I
B91018B
I
85652
2
14353621 I
86292
I
75475
2
85651
2
99617
2
38150
2

ii

B281_

12
13
14
15
16
18
19
20
21
23
24
25
26
27
28
29
30
31
32
33
34
36
38
45
46
47
48
49
50
51
52

66365F
B281_
65791
47480
66825B
84986
86308G
22264
66849
68759
77247
82819
91825
96796
23365
51715
74908
86494
84242
86307
67022
26850
22769
93639
93640
98319
84346
20566
77816
99541
67989

2
I
I
I
2
2
4
I
2
4
I
2

Description
ENGINE
ASSEMBLY,Cradle
MOUNT, Vibration Air.
WIRE, Ground
CAPSCREW, Self Driller #10
SCREW, PHM M4 - 0.7 x 10
MOUNT, Vibration Engine
NUT, Pal
WASHER, #8 Flat
ASSEMBLY,Stator
HOUSING, EngineAdapter
ASSEMBLY,Rotor
BEARING, Ball
BOLT, Rotor 5/16" - 24 x 7.00"
CARRIER, Rear Bearing
DECAL, Ground
BOLT, Stator M6 1.00 x 100mm
WASHER, No. 8 Lock
SCREW, M5 - .80 x 16ramTaptite
RECEPTACLE,120V AC, 20AMP
BREAKER,Circuit - 20AMP
ASSY.,Control Panel
RECTIFIER,Brush & Bridge
WASHER, Flat
WASHER, Shakeproof No. 8
NUT, M4 - 0.7 Hex
SCREW, M5 0.80 x 10ram Taptite
SCREW, M6- 1.0 x 16 Wing
GROMMET, Plastic RBC
CAPSCREW, Hx Hd 5/16"-24 × 3/4"
GROMMET, Rubber
WASHER, M6 I/4 Shakeproof
WASHER, #10 5hakeproof
DECAL, Danger (English)
DECAL, Danger (Spanish)
DECAL, Control Panel
DECAL, Unit
DECAL, 1-800 Number
DECAL, Caution Hot Muffler
DECAL, Start Instructions
NUT, M8 FlangedSerrated

15

PORTABLE

GENERATOR

LIMITED

WARRANTY

GENERAC PORTABLE PRODUCTS, LLC (hereafter referred to asthe COMPANY) warrants to the original purchaser
that the components in its generator will be free from defects in materials or workmanship for a period of one year* from
the date of original purchase. This warranty does not apply to units used for prime power in place of utility. This warranty
does not includethe gasoline engine when furnished or attached because such engine is covered solely by the engine
manufacturer's warranty Starting batteries are not warranted by the COMPANY.. The term "original purchaser" means
the person for whom the generator is originally purchased. This warranty is not transferable.

*NOTE: Rental units, demonstrators, commercial applications, such as construction or incomeproducing, are warranted
for 90 days. Rental units, demonstrators, or commercial applications such as construction or utility which are resold are
not covered under warranty by the COMPANY. Any warranty, whether expressed or implied, rests solely with the seller.

During the warranty period, the COMPANY will, at its option, repair or replace any part which, upon examination by the
COMPANY isfound to be defective under normal use and service. All transportation costs under warranty, including
return to the factory if necessary,are to be borne by the purchaser and prepaid by the purchaser. This warranty does not
include nominal maintenance and service and does not apply to a generator set, or parts, which have been subjected to
improper or unauthorized installation, misuse, negligence, accident, overloading, overspeeding, improper maintenance,
repair or storage so as, in the COMPANY's judgment, to adversely affect its performance and reliability.
THERE IS NO OTHER EXPRESSWARRANTY. THE COMPANY HEREBY DISCLAIMS ANY AND ALL
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND
FITNESSFOR A PARTICULAR PURPOSETO THE EXTENT PERMITTED BY LAW. THE DURATION OF
ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS
SPECIFIEDIN THE EXPRESSWARRANTY. LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, OR
SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT
PERMITTED BY LAW. THE COMPANY ALSO DISCLAIMS ANY RESPONSIBILITYFOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES SUCH AS THE LOSS OF TIME OR THE USE OF THE POWER
EQUIPMENT, OR ANY COMMERCIAL LOSS DUE TO THE FAILURE OF THE EQUIPMENT; AND ANY
IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY.

Some states do not allow limitations on how long an impliedwarranty lasts, or the exclusions or limitations of incidental
or consequential damages,so the above limitations or exclusions may not apply to you. This warranty gives you specific
legal rights and you may also have other rights, which vary from state to state.

This warranty is effective for all products manufactured after June, 1998, and supersedes all prior warranties of the
COMPANY.

For service, see your nearest COMPANY authorized warranty service facility or call 1-877-544-0982. Or look on the
internet at www.generac-portabtes.com. Warranty service can be performed only by a COMPANY authorized service
facility. This warranty will not apply to service at any other facility. At the time of requesting warranty service, evidence of
original purchase date must be presented.

GENERAC

PORTABLE
Jefferson,

PRODUCTS,
Wisconsin

U.S.A.

LLC



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 16
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Wed Apr 04 21:47:16 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu