Generac 004702 0 004703 004704 004705 004706 004707 Owners Manual 0E1015RevB
004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 to the manual 167b27f4-0eb9-44a7-a084-8ef91f0f692f
2015-01-05
: Generac Generac-004702-0-004703-0-004704-0-004705-0-004706-0-004707-0-Owners-Manual-166110 generac-004702-0-004703-0-004704-0-004705-0-004706-0-004707-0-owners-manual-166110 generac pdf
Open the PDF directly: View PDF .
Page Count: 56
Download | |
Open PDF In Browser | View PDF |
Owner’s Manual Air-cooled Recreational Vehicle Generators QUIETPACT 55, 65 and 75 • Models: 004702-0, 004703-0 004704-0, 004705-0 004706-0, & 004707-0 QUIETPACT 55G POWERED BY GUARDIAN 760cc OHVI V-TWIN INDUSTRIAL This manual should remain with the unit. INTRODUCTION ◆ READ THIS MANUAL THOROUGHLY If you do not understand any portion of this manual, contact Generac or your nearest Generac Authorized Service Dealer for starting, operating and servicing procedures. Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert you to special instruction about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows: DANGER After this heading, you can read instructions that, if not strictly complied with, will result in personal injury, including death, and property damage. After this heading, you can read instructions that, if not strictly complied with, may result in personal injury or property damage. After this heading, you can read instructions that, if not strictly complied with, could result in damage to equipment and/or property. NOTE: After this heading, you can read explanatory statements that require special emphasis. These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents. Four commonly used safety symbols accompany the Danger, Warning and Caution blocks. The type of information each indicates follows: ! This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of you and others. This symbol points out potential explosion hazard. This symbol points out potential fire hazard. This symbol points out potential electrical shock hazard. The operator (driver) is responsible for proper and safe use of the vehicle and its equipment, and the safety of all vehicle occupants. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using this equipment. We also strongly recommend instructing other occupants in the vehicle to properly start and operate the generator. This prepares them if they need to operate the equipment in an emergency. ◆ CONTENTS This manual contains pertinent owner’s information, including warranty, electrical diagrams, exploded views and lists of repair parts for generator model numbers 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0. In addition, the latter portion of this manual contains information necessary for the proper installation of these generators. ◆ OPERATION AND MAINTENANCE It is the operator's responsibility to perform all safety checks, to make sure that all maintenance for safe operation is performed promptly, and to have the equipment checked periodically by a Generac Authorized Service Dealer. Normal maintenance service and replacement of parts are the responsibility of the owner/operator and, as such, are not considered defects in materials or workmanship within the terms of the warranty. Individual operating habits and usage contribute to the need for maintenance service. Proper maintenance and care of your generator ensure a minimum number of problems and keep operating expenses at a minimum. See your Generac Authorized Service Dealer for service aids and accessories. ◆ HOW TO OBTAIN SERVICE When your generator requires servicing or repairs, simply contact a Generac Authorized Service Dealer for assistance. Service technicians are factory-trained and are capable of handling all of your service needs. When contacting a Generac Authorized Service Dealer or the factory about parts and service, always supply the complete model number and serial number of your unit as given on its data decal, which is located on your generator. Model No. ____________ Serial No. ______________ AUTHORIZED SERVICE DEALER LOCATION To locate the GENERAC AUTHORIZED SERVICE DEALER nearest you, please call this number: 1-800-333-1322 ONLY DEALER LOCATION INFORMATION CAN BE OBTAINED AT THIS NUMBER. Generac® Power Systems, Inc. Table of Contents QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Part I — Operating Instructions Introduction ..................................................Inside Front Cover Read This Manual Thoroughly ..........................................IFC Contents ............................................................................IFC Operation and Maintenance ..............................................IFC How to Obtain Service ......................................................IFC Authorized Service Dealer Locator Number ..........................IFC Safety Rules ..................................................................................2 Section 1 – General Information ............................................4 1.1 1.2 1.3 1.4 1.5 1.6 Generator Identification ................................................4 Generator Applicability ..................................................5 Installation ....................................................................5 Safety ............................................................................5 Generator AC Connection System ..................................5 Specifications ................................................................6 1.6.1 Fuel Requirements ..............................................6 1.6.2 Engine Oil Requirements ....................................6 1.6.3 Generator Specifications......................................6 1.6.4 Engine Specifications ..........................................7 1.6.5 Emissions Compliance Period ............................7 Part II — Installation Instructions ........................................17 Safety Rules................................................................................18 Section 5 — General Information..........................................20 5.1 5.2 5.3 5.4 5.5 5.6 Section 6 — Installation ..........................................................22 6.1 6.2 Section 2 – Operation ................................................................7 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Generator Control Panel ................................................7 2.1.1 Fuel Primer ..........................................................7 2.1.2 Start/Stop Switch ................................................7 2.1.3 15 Amp Fuse........................................................7 2.1.4 Line Breakers ......................................................7 Optional Remote Start/Stop Panel..................................8 Automatic Choke ..........................................................8 2.3.1 Choke Solenoid ..................................................8 2.3.2 Prechoke..............................................................8 Before Starting the Engine ............................................8 2.4.1 Installation..............................................................8 2.4.2 Engine Lubrication ................................................8 2.4.3 Fuel Supply ............................................................8 2.4.4 Cooling and Ventilating Air ....................................8 2.4.5 Engine Exhaust Gas ..............................................8 Starting the Generator ..................................................9 Stopping the Generator..................................................9 Applying Loads to Generator ........................................9 2.7.1 Letting the Engine Stabilize ................................9 2.7.2 Do Not Overload the Generator ........................10 Protection Systems ......................................................10 2.8.1 Low Oil Pressure Switch....................................10 2.8.2 High Temperature Switch ..................................10 2.8.3 Field Boost ........................................................10 2.8.4 Overvoltage Protection ......................................11 2.8.5 25-Hour Break-in Period....................................11 2.8.6 25-Hour Checkup ..............................................11 2.8.7 Operation in High Grass or Brush ....................11 Section 3 – Maintenance ........................................................11 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 Checking the Engine Oil Level......................................11 Changing the Engine Oil and/or Oil Filter ....................12 Maintaining the Engine Air Cleaner ............................12 3.3.1 Cleaning the Foam Precleaner............................12 Checking the Engine Spark Plug..................................13 Fuel Filter (Gasoline Only) ..........................................13 Clean Spark Arrestor ..................................................13 Cleaning the Generator ................................................14 Battery Maintenance ....................................................14 3.8.1 Weekly ..............................................................14 3.8.2 Every Six Months ..............................................14 Major Service Manual ..................................................15 Drive Belt ....................................................................15 Exercising the Generator ............................................15 Out of Service Procedure ............................................15 3.12.1 Removal From Service ....................................15 3.12.2 Return to Service ............................................15 RV Generator Service Interval......................................15 Section 4 – Notes......................................................................16 Purpose and Scope of the Installation Instructions......20 Safety ..........................................................................20 Standards Booklets ....................................................20 Equipment Description................................................20 Generator Engine Operating Speed..............................20 Generator AC Connection System ................................20 Major Features and Dimensions ..................................21 6.3 6.4 6.5 6.6 6.7 6.8 6.9 Location and Support ..................................................22 6.1.1 Generator Location............................................22 6.1.2 Generator Support ............................................22 6.1.3 Suspended Mounting ........................................23 6.1.4 Generator Restraint ..........................................23 Generator Compartments ............................................23 6.2.1 Compartment Size ............................................23 6.2.2 Compartment Construction ..............................23 6.2.3 Sound Insulating Materials ................................24 6.2.4 Acoustics ..........................................................25 6.2.5 Compartment Floor Cutouts..............................25 Cooling and Ventilating Air ..........................................25 6.3.1 Generator Airflow ..............................................25 6.3.2 Testing the Installation ......................................26 Gasoline Fuel System ..................................................26 6.4.1 Fuel Tank ..........................................................27 6.4.2 Generator Fuel Supply Line ..............................27 LP Gas Fuel System ....................................................27 6.5.1 LP Fuel Consumption ........................................27 6.5.2 Parts Not Included in Fuel System ....................27 6.5.3 Some Important Considerations ........................28 6.5.4 Vapor Withdrawal ..............................................28 6.5.5 Primary Regulator..............................................28 6.5.6 Gaseous Carburetion ........................................28 6.5.7 Fuel Supply Lines ..............................................29 6.5.8 Excess Flow Valve ..............................................29 6.5.9 Leakage Tests ....................................................29 Exhaust System ..........................................................29 6.6.1 Mufflers and Spark Arrestors............................30 6.6.2 Exhaust System Safety ......................................30 Electrical Connections ................................................30 6.7.1 Electrical Junction Box ....................................30 6.7.2 Wiring ................................................................31 6.7.3 Generator AC Connections ................................31 6.7.4 Conduit..............................................................31 6.7.5 Isolating Different Power Sources ......................31 6.7.6 Power Supply Cord............................................31 6.7.7 Ground Fault Circuit Interrupters ....................32 Battery Installation ......................................................32 6.8.1 Recommended Battery ......................................32 6.8.2 Battery Cables ..................................................32 6.8.3 Battery Cable Connections ................................32 6.8.4 Battery Compartment ........................................32 Optional Accessories....................................................34 6.9.1 Remote Panel Models ........................................34 Section 7 — Post Installation ................................................34 7.1 7.2 7.3 7.4 7.5 Post Installation Tests ..................................................34 Before Initial Start-up ..................................................34 Initial Start ..................................................................34 Testing Under Load......................................................35 Installation Checklist ..................................................35 Section 8 – Troubleshooting ..................................................36 8.1 Troubleshooting Guide ................................................36 Section Section Section Section 9 – Notes......................................................................37 10 – Electrical Data ..................................................38 11 – Exploded Views and Parts Lists....................40 12 – Warranty ............................................................52 Generac® Power Systems, Inc. 1 Safety Rules QUIETPACT 55, 65, and 75 Recreational Vehicle Generators SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas of the recreational vehicle. Safety should be stressed to all operators and potential operators of this equipment. ! ! WARNING: ! The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. ! WARNING: ! This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this manual and with the unit. The generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions. Generac cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit, are, therefore, not all-inclusive. If you use a procedure, work method or operating technique Generac does not specifically recommend, you must satisfy yourself that it is safe for you and others. You also must make sure the procedure, work method or operating technique that you choose does not render the generator unsafe. DANGER ! Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment. Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator. ! 2 Parts of the generator are rotating and/or hot during operation. Exercise care near running generators. Generac® Power Systems, Inc. ! ! GENERAL HAZARDS ! • For safety reasons, Generac recommends that the installation, initial start-up and maintenance of this equipment is carried out by a Generac Authorized Service Dealer. • The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently, (b) nausea, (c) vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weakness, and (i) sleepiness. IF YOU EXPERIENCE ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired. • Never sleep in the vehicle while the genset is running unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area. • Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating. • Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. • When working on this equipment, remain alert at all times. Never work on the equipment when you are physically or mentally fatigued. • Inspect the generator regularly, and contact your nearest Generac Authorized Service Dealer immediately for parts needing repair or replacement. Safety Rules QUIETPACT 55, 65, and 75 Recreational Vehicle Generators • Before performing any maintenance on the generator, disconnect its battery cables to prevent accidental start up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc. ELECTRICAL HAZARDS • The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If you must work around an operating unit, stand on an insulated, dry surface to reduce shock hazard. • Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT. • During installation onto the vehicle, have the generator properly grounded (bonded) either by solid mounting to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT disconnect the bonding conductor, if so equipped. DO NOT reconnect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum. • In case of accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting implement, such as a rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help. • Never wear jewelry when working on this equipment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving components causing injury. FIRE HAZARDS • For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installation, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regulations. • Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged and be familiar with its use. If you have any question pertaining to fire extinguishers, consult your local fire department. EXPLOSION HAZARDS • Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left in the generator compartment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris. • Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws governing the storage and handling of gasoline. • This generator may use liquid propane (LP) gas as a fuel. LP gas is highly EXPLOSIVE. The gas is heavier than air and tends to settle in low areas where even the slightest spark can ignite the gas and cause an explosion. Generac® Power Systems, Inc. 3 Section 1 – General Information QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 1.1 GENERATOR IDENTIFICATION Please record the following information from the generator DATA DECAL or information decal. 1. Model Number ____________________ 2. Serial Number __________________ 3. kW Rating__________________________ 4. Rated Voltage __________________ 5. Phase ______________________________ 6. Hertz __________________________ 16 4 8 2 5 10 STARTING, DO NOT PRESS START BUTTON LONGER THEN 15 SECONDS PER ATTEMPT. 14 3 P A N EL AIR FILTER: OIL & OIL FILTER: CLEAN PREFILTER EVERY 100 HOURS. * REPLACE ELEMENT EVERY 250 HOURS. * CHANGE EVERY 100 HOURS. (OR ANNUALLY) * * OIL CAPACITY WITH FILTER: 1.8L/1.9QT TEMPERATURE: (SAE VISCOSITY) 40˚F AND HIGHER SAE 30 OR 10W-30 5W-30 OR 5W-20 072347 087769 13 17 12 11, 15 (Behind Access Panel) 1 19 7 6 9, 18 REFERENCE NUMBER IDENTIFICATION 1. Generator Air Intake Screen 2. Data Plate 3. Engine Start/Stop Switch 4. 7.5 amp Fuse 5. Circuit Breaker 6. Optional Remote Panel Receptacle 7. Generator AC Output Leads 8. Starter Contactor 9. Fuel Inlet 10. Fuel Primer Switch 4 Generac® Power Systems, Inc. 11. Fuel Pump (Behind access panel.) 12. Oil Filter 13. Oil Drain Plug 14. Oil Dipstick and Filler Tube 15. Air Filter (Behind access panel.) 16. Spark Plugs 17. Exhaust Outlet 18. Fuel Filter 19. LP Fuel Inlet Section 1 – General Information QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 1.2 GENERATOR APPLICABILITY These generators have been designed and manufactured for supplying electrical power for recreational vehicles. You should not modify the generator or use it for any application other than for what it was designed. If there are any questions pertaining to its application, write or call the factory. Do not use the unit until you have been advised by competent authority. DANGER For fire safety, the generator must have been properly installed in compliance with ANSI 119.2-1975/NFPA 501C-1974, “Standard for Recreational Vehicles, Part III – Installation of Electrical Systems.” The generator also must have been installed in strict compliance with the manufacturer’s detailed installation instructions. After installation, do nothing that might render the unit in noncompliance with such codes, standards and instructions. You can use your generator set to supply electrical power for operating one of the following electrical loads: • QUIETPACT 55G & LP: 120 and/or 240 volts, single phase, 60 Hz electrical loads. These loads can require up to 5500 watts (5.5 kW) of total power, but cannot exceed 45.8 AC amperes of current at 120 volts or exceed 22.9 AC amperes at 240 volts. • QUIETPACT 65G & LP: 120 and/or 240 volts, single phase, 60 Hz electrical loads. These loads can require up to 6500 watts (6.5 kW) of total power, but cannot exceed 54.1 AC amperes of current at 120 volts or exceed 27 AC amperes at 240 volts. • QUIETPACT 75G & LP: 120 and/or 240 volts, single phase, 60 Hz electrical loads. These loads can require up to 7500 watts (7.5 kW) of total power, but cannot exceed 62.5 AC amperes of current at 120 volts or exceed 31.2 AC amperes at 240 volts. ! Do not overload the generator. Some installations may require that electrical loads be alternated to avoid overloading. Applying excessively high electrical loads may damage the generator and may shorten its life. Add up the rated watts of all electrical lighting, appliance, tool and motor loads the generator will power at one time. This total should not be greater than the wattage capacity of the generator. If an electrical device nameplate gives only volts and amps, multiply volts times amps to obtain watts (volts x amps = watts). Some electric motors require more watts of power (or amps of current) for starting than for continuous operation. 1.3 INSTALLATION This Owner’s Manual has been prepared under the assumption that a competent, qualified technician installed the generator into a recreational vehicle. We also assume the installer complied with all applicable codes, standards and regulations pertaining to installation. An INSTALLATION MANUAL was shipped with the generator. That Manual contains manufacturer’s instructions and recommendations for installing the unit into an industrial vehicle. After installation, installers should forward the Installation Manual to Owners/Operators for their information. Owners/Operators have the responsibility to make sure that nothing is done that might render the installation unsafe or in non-compliance with applicable codes, standards and instructions. 1.4 SAFETY Before using the generator set, carefully read GENERAL SAFETY RULES inside the cover. Comply with these RULES to prevent accidents and damage to equipment and/or property. Generac suggests copying and posting the GENERAL SAFETY RULES to potential operators of this equipment. 1.5 GENERATOR AC CONNECTION SYSTEM These air-cooled generator sets are equipped with dual stator AC power windings. These two stator windings supply electrical power to customer electrical loads by means of a dual 2-wire connection system. Generators may be installed to provide the following outputs: 1. 120 VAC loads only — one load with a maximum total wattage requirement equal to the generator’s rated power output (in watts), and 120V across the generator output terminals. Figure 1.1, page 6, shows the generator lead wire connections for 120VAC ONLY. 2. 120/240 VAC loads — one load with a maximum total wattage requirement equal to the generator’s rated power output, and 240V across the generator output terminals; or two seperate loads, each with a maximum total wattage requirement equal to half of the generator’s rated power output (in watts), and 120V across the generator output terminals. Figure 1.2, page 6, shows the generator lead wire connections for 120/240 VAC loads. Also refer to section 2.1.4 Line Breakers for circuit breaker ratings. This procedure should be done by a Generac Authorized Service Dealer or other qualified installer. Generac® Power Systems, Inc. 5 Section 1 – General Information QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ✧ Figure 1.1 – Connection for 120 Volts Only 1.6.1.1 Fuel Consumption (gph/lbs.ph) Model QuietPact 55G QuietPact 65G QuietPact 75G 10% Load 0.51 0.51 0.51 50% Load 0.73 0.76 0.80 100% Load 0.97 1.07 1.28 NOTE Some installations using a “shared” fuel tank may have a generator fuel pickup tube that is shorter than the vehicle engine’s pickup tube. Such an arrangement causes the generator engine to “run out of gas” while adequate fuel for the vehicle remains in the tank. To reduce lead and carbon deposits use high quality UNLEADED gasoline with the generator. Leaded REGULAR grade gasoline is an acceptable substitute. NOTE: Using unleaded gasoline contributes to longer engine valve life by reducing lead and carbon deposits. Figure 1.2 - Connection for 120/240 Volts CB1 T1 RED ! T2 WHITE CB2 STATOR WINDINGS 1.6 T3 BLACK GROUNDED NEUTRAL Generac does not recommend using any gasoline containing alcohol (such as “gasohol”). If you use any gasoline containing alcohol, it must not contain more than 10 percent ethanol, and it must be removed from the generator during storage. Do NOT use any gasoline containing methanol. If you use gasoline with alcohol, inspect more frequently for fuel leaks and other abnormalities. ◆ 1.6.2 ENGINE OIL REQUIREMENTS SPECIFICATIONS ◆ 1.6.1 FUEL REQUIREMENTS (GASOLINE) This generator is equipped with a gasoline fuel system as standard equipment. Specific installations may provide either a separate fuel tank for the generator, or the generator may “share” the vehicle engine’s fuel tank. Use only high quality detergent oil classified “For Service SF” and with an oil viscosity rating of SAE 10W-30 oil. Do not pour in any additives to the recommended oil. Engine crankcase capacity is 1.8 liters or 1.9 quarts with oil filter change. See Section 3.2 on page 11 for oil level check and filing procedures. ◆ 1.6.3 GENERATOR SPECIFICATIONS SERIES Rotor RPM Rotor Poles Engine RPM Rated Max. Continuous AC Output Watts* Voltage* Rated Max. Continuous Current Amps (240V) Phase Frequency Battery Charging Current (Max.) Weight Length Width Height QP55G 3600 2 2200 5500 120 45.8 (22.9) 1 60 Hertz 2 amps 326 lbs. 33.7 in. 22.2 in. 19.6 in. QP55LP 3600 2 2200 5500 120 45.8 (22.9) 1 60 Hertz 2 amps 329 lbs. 33.7 in. 22.2 in. 19.6 in. QP65G 3600 2 2571 6500 120 54.1 (27.0) 1 60 Hertz 2 amps 328 lbs. 33.7 in. 22.2 in. 19.6 in. QP65LP 3600 2 2571 6500 120 54.1 (27.0) 1 60 Hertz 2 amps 331 lbs. 33.7 in. 22.2 in. 19.6 in. QP75G 3600 2 2571 7500 120 62.5 (31.2) 1 60 Hertz 2 amps 330 lbs. 33.7 in. 22.2 in. 19.6 in. QP75LP 3600 2 2571 7500 120 62.5 (31.2) 1 60 Hertz 2 amps 333 lbs. 33.7 in. 22.2 in. 19.6 in. * All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output 6 Generac® Power Systems, Inc. Section 2 – Operation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Type of Engine QUIETPACT 55/65/75 ................................................GT-760 Cooling Method ........................................................Air-cooled Rated Horsepower QUIETPACT 55..............................................27 at 3600 rpm QUIETPACT 65..............................................27 at 3600 rpm QUIETPACT 75..............................................27 at 3600 rpm Displacement QUIETPACT 55/65/75....................................................760cc Compression Ratio........................................................8.6 to 1 Cylinder Block ..........................Aluminum w/Cast Iron Sleeve Type of Governor ..............................Mechanical, Fixed Speed Engine Governor Speed QUIETPACT 55 ......................................................2200 rpm QUIETPACT 65/75..................................................2571 rpm Air Cleaner ........................Paper Element w/Foam Precleaner Starter ........................................................12-volt DC Electric Ignition System ......................Solid-state w/Flywheel Magneto Recommended Spark Plug Champion ..................................................................RC12YC AC....................................................................................R45S Fram Autolite ......................................................................65 Spark Plug Gap........................................0.030 inch (0.8 mm) Recommended Min. Battery ............400 Cold Cranking Amps ◆ 1.6.5 EMISSIONS COMPLIANCE PERIOD For nonhandled engines the Emissions Compliance Period referred to on the Emissions Compliance Label indicates the number of operating hours for which the engine has been shown to meet Federal emission requirements. • For engines less than 225 cc displacement, Category C=125 hours, B=250 hours, and A=500 hours. • For engines of 225 cc or more, Category C=250 hours, B=500 hours, and A=1000 hours. 2.1 ◆ 2.1.2 START/STOP SWITCH To crank and start the engine, hold this switch in the START position. Release the switch when the engine starts. To stop an operating engine, press and hold the switch in the STOP position until the engine shuts off. The switch center position is the RUN position. ◆ 2.1.3 7.5 AMP FUSE The fuse protects the engine’s DC control circuit against electrical overload. If the fuse element has melted open due to overloading, the engine cannot be cranked. If you must replace the fuse, use only an identical 7.5 amp replacement fuse. ◆ 2.1.4 LINE BREAKERS Protects generator’s AC output circiut against overload, i.e., prevents unit from exceeding wattage/amperage capacity. The circuit breaker ratings are as follows: Model QuietPact 55 QuietPact 65 QuietPact 75 Circuit Breaker 1 30A 30A 35A Circuit Breaker 2 20A 30A 35A NOTE: If this generator has been reconnected for dual voltage AC output (120/240 volts), you can install line breakers having an amperage rating that is different than that stated above. The replacement line breakers consist of two separate breakers with a connecting piece between the breaker handles (so that both breakers will operate at the same time). If the unit is reconnected for dual voltage, it is no longer RVIA or CSA listed. Figure 2.1 – Typical Control Panel CONTROL CENTER GENERATOR CONTROL PANEL C IR U IT B REA K ER The following features are mounted on the generator control panel (Figure 2.1): C IR U IT B R A K ER ◆ 2.1.1 FUEL PRIMER Before starting a cold engine (if it has not been started in more than two weeks), you must press this switch for approximately ten seconds to bring fuel from the tank to the fuel pump. This rocker type switch springs back into its original position when you release it. 240 Volt 25A 2P 30A 2P 35A 2P F S E 7 .5 A IF GENERATOR DOES NOT START. REMOVE AND INSPECT FUSE. (SEE OWNER'S MANUAL TROUBLE SHOOTING GUIDE.) S T A RT FUEL S T OP P R IM E 0E0580 REV. B ◆ 1.6.4 ENGINE SPECIFICATIONS PRESS PRIME SWITCH FOR 10 SECONDS BEFORE STARTING. WHEN STARTING, DO NOT PRESS START BUTTON LONGER THEN 15 SECONDS PER ATTEMPT. Generac® Power Systems, Inc. 7 Section 2 – Operation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 2.2 OPTIONAL REMOTE START/STOP PANEL A remote mounted Start/Stop Panel (Figure 2.2) is available that allows you to start and stop the generator engine conveniently from inside the vehicle. The remote panel includes a Start/Stop switch, hourmeter, generator run lamp and a wire harness. Figure 2.2 — Optional Remote Panel (Models 004057 and 004184) ◆ 2.4.1 INSTALLATION Generator installation must have been properly completed so it complies with all applicable codes, standards and regulations and with the manufacturer's recommendations. ◆ 2.4.2 ENGINE LUBRICATION Have the engine crankcase properly serviced with the recommended oil before starting. Refer to Section 1.6.3 (Page 6) and Sections 3.1 and 3.2 (Page 11) for oil servicing procedures and recommendations. ! Any attempt to crank or start the engine before you have properly serviced it with the recommended oil may result in an engine failure. ◆ 2.4.3 FUEL SUPPLY 2.3 AUTOMATIC CHOKE This engine is equipped with an automatic choke that consists of two main components: a choke solenoid and prechoke. ◆ 2.3.1 CHOKE SOLENOID During engine cranking (Start/Stop switch at START), a solid-state choke module signals the choke solenoid to activate and cycle (choke on/choke off) until the engine starts. The choke solenoid thus opens and closes the carburetor choke valve only when the engine is cranking. When the engine starts, the choke stops cycling. ◆ 2.3.2 PRECHOKE The choke system also has a temperature-sensitive metal strip that adjusts choke valve angle according to ambient temperatures (i.e., in cold ambient temperatures, choke valve closes more). Once the engine starts, an element heats the temperature-sensitive strip to a normal operating condition, opening the choke valve. This may take about three minutes in cooler weather. 2.4 BEFORE STARTING THE ENGINE NOTE: Instructions and information in this manual assume the generator has been properly installed, connected, serviced, tested and adjusted by a qualified installation technician or installation contractor. 8 Generac® Power Systems, Inc. The engine must have an adequate supply of proper fuel to operate. Before starting it, check that sufficient fuel is available. NOTE: Depending on the installation, the generator may have either a separate fuel tank, or it may “share” the vehicle engine’s fuel tank. ◆ 2.4.4 COOLING AND VENTILATING AIR Air inlet and outlet openings in the generator compartment must be open and unobstructed for continued proper operation. Without sufficient cooling and ventilating airflow, the engine/generator quickly overheats, which causes it to shut down and may damage the generator. ◆ 2.4.5 ENGINE EXHAUST GAS Before starting the generator engine, you should be sure there is no way for exhaust gases to enter the vehicle interior and endanger people or animals. Close windows, doors and other openings in the vehicle that, if open, might permit exhaust gases to enter the vehicle. Section 2 – Operation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators DANGER ! The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently, (b) nausea, (c) vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weakness, and (i) sleepiness. IF YOU EXPERIENCE ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired. DANGER ! 2.5 Never sleep in the vehicle while the genset is running unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area. STARTING THE GENERATOR NOTE: Read the vehicle manufacturer’s instructions. The owner/operator should become familiar with the vehicle in which this generator is installed. Differences exist between vehicles. For example, some vehicles may use a transfer switch to isolate dockside power from the generator, while other vehicles may use an isolating receptacle. Some vehicles may be equipped with a DC converter which allows the generator to power certain DC lighting and other DC loads. To crank and start the generator engine, proceed as follows: 1. Turn OFF electrical loads using the means provided in your vehicle (such as a main line circuit breaker or transfer switch). NOTE: 2. If you have not started the engine in more than two weeks, press the Fuel Pump Primer switch and hold it for about 10 seconds. However, if the engine is warm, skip Step 2. 3. To crank and start the engine, hold the start/stop switch at START. Release the switch when the engine starts. If the engine does not start after it has been cranking for 15 seconds, release the Start/Stop switch and wait 1 minute before trying again. Holding the switch for longer than 15 seconds can damage the starter motor. 4. Let the engine run at no-load for a few minutes to stabilize and warm up. 5. Turn ON electrical loads using the means provided (such as a main circuit breaker or transfer switch). ! 2.6 STOPPING THE GENERATOR 1. Turn OFF all electrical loads using the means provided (such as a main circuit breaker or transfer switch). 2. Let generator run at no-load for a few minutes, to stabilize internal engine generator temperatures. 3. Place the Start/Stop switch in its STOP position. The engine will come to a complete stop. 2.7 APPLYING LOADS TO GENERATOR When applying electrical loads to the generator, observe these guidelines: • Before applying electrical loads, let the generator stabilize and warm up for a minute or two. • DO NOT overload the generator. ◆ 2.7.1 LETTING THE ENGINE STABILIZE The generator supplies correct rated voltage only at the proper governed speed. Some electrical appliances may be extremely sensitive to voltage. Incorrect voltages can damage such appliances. If electrical loads are applied at reduced operating speeds, such loads imposed on the engine when sufficient power is not available may shorten engine life. Never turn ON electrical loads until after the generator engine has started and stabilized at no-load. If starting from the generator control panel, turn OFF loads by setting the generator’s main circuit breaker to the OFF (or open) position. If starting from a remote panel, turn OFF loads using the means provided in the vehicle (such as a main circuit breaker). Electrical load circuits will be turned ON after the generator has started, stabilized and warmed up. Generac® Power Systems, Inc. 9 Section 2 – Operation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 2.7.2 DO NOT OVERLOAD THE GENERATOR You can read the rated wattage/amperage capacity of your generator on the generator data decal (see Section 1.1 on Page 4). Applying electrical loads in excess of the unit’s rated capacity will cause the engine/generator to automatically shut down. To avoid overloading, add up the wattage of all connected electrical lighting, appliance, tool and motor loads. This total should not be greater than the generator’s rated wattage capacity. • Most lighting, appliance, tool and motor loads indicate their required watts on their nameplate or data plate. For light bulbs, simply note the wattage rating of the bulb. • If a load does not show its rated wattage, multiply that load’s rated VOLTS times AMPS to obtain WATTS. • Induction type motors (such as those that run the vehicle’s furnace fan, refrigerator, air conditioner, etc.) need about 2-1/2 times more watts of power for starting than for running (for a few seconds during motor starting). Be sure to allow for this when connecting electrical loads to the generator. First, figure the watts needed to start electric motors in the system. To that figure, add the running wattages of other items that will be operated by the generator. • Do not apply heavy electrical loads for the first two or three hours of operation. 2.8 PROTECTION SYSTEMS ◆ 2.8.1 LOW OIL PRESSURE SWITCH This switch (Figure 2.3) has normally closed (N.C.) contacts that are held open by engine oil pressure during cranking and operating. Should oil pressure drop below a preset level, switch contacts close, and the engine automatically shuts down. The unit should not be restarted until oil is added. 10 Generac® Power Systems, Inc. ◆ 2.8.2 HIGH TEMPERATURE SWITCH This switch (Figure 2.3), which has normally open (N.O.) contacts, is mounted near the oil filter. The contacts close if the temperature should exceed approximately 270º F (132º C) for gasoline models, and 284° F (140° C) for LP models, initiating an engine shutdown. Figure 2.3 – Low Oil Pressure and High Temperature Switches ◆ 2.8.3 FIELD BOOST The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.4). During engine cranking only, a positive DC (battery) voltage is delivered through a diode, resistor, brushes, slip rings, and the generator rotor. Application of this voltage to the rotor “flashes the field” whenever it is started. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings. Figure 2.4 – Field Boost Circuit Section 3 – Maintenance QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 2.8.4 OVERVOLTAGE PROTECTION A solid-state voltage regulator (Figure 2.5) controls the generator’s AC output voltage. This regulator supplies an excitation current to the rotor. By regulating the rotor’s excitation current, the strength of its magnetic field is regulated and, in turn, the voltage delivered to connected electrical loads is controlled. When the AC frequency is 60 Hertz, voltage is regulated at 115 volts. Figure 2.5 – Solid State Voltage Regulator ◆ 2.8.6 25-HOUR CHECK-UP After the 25-hour break-in period, contact a Generac Authorized Service Dealer for the following maintenance. (The vehicle owner is responsible for any charges relating to normal unit maintenance.) • • • • • • Change the engine crankcase oil and oil filter. Check all fluid levels. Inspect the cooling and ventilation openings. Check the engine ignition system. Inspect the entire electrical system. Inspect the engine exhaust system. ◆ 2.8.7 OPERATION IN HIGH GRASS OR BRUSH The voltage regulator also incorporates a “voltage surge protection circuit.” This circuit prevents troublesome surges in the generator AC output voltage. Voltage surge is a common cause of damage to electronic equipment. ◆ 2.8.5 25-HOUR BREAK-IN PERIOD The first 25 hours of operation is the break-in period for the generator. Properly breaking in the generator is essential to minimize fuel consumption and provide maximum engine performance. During this 25hour break-in period, follow this procedure: • Run the unit at varying electrical loads to help seat the engine piston rings properly. • Check the engine oil level frequently. Add oil if needed. It is normal for the generator engine to consume more oil than is normal until the piston rings have properly seated. • For the 75-hour operation following the break-in period, avoid light electrical loads. Load the generator at 50 percent (or more) of its rated wattage capacity. Repeated light loads during these 75 hours can cause improper seating of engine piston rings, resulting in blowby and high oil consumption. • After operating the unit for 25 hours, complete the tasks recommended under Section 2.8.6. Never operate the generator while the vehicle is parked over high grass, weeds, brush, leaves or any other combustible substance. Such materials can ignite and burn from the heat of the exhaust system. The generator exhaust system becomes extremely hot during operation and remains hot for a long time after it has shut down. 3.1 CHECKING THE ENGINE OIL LEVEL For oil capacities and requirements, see “Engine Oil Requirements,” Section 1.6.2 (Page 6). Check the engine crankcase oil level at least every eight hours of operation, or before you use it. To check the engine oil level, proceed as follows (see Figure 3.1): 1. Be sure the generator is as level as possible. 2. Remove the dipstick and wipe it dry with a clean, lint-free cloth. 3. Install and tighten the dipstick cap; then, remove it again. The oil level should be at the dipstick “Full” mark. 4. If necessary, remove the oil fill cap on the rocker cover and slowly add oil until it reaches the dipstick “Full” mark. DO NOT FILL ABOVE THE “FULL” MARK. Never operate the engine with the oil level below the “Add” mark on the dipstick. Doing this could damage the engine. 5. Install and tighten the oil fill cap and the dipstick before operating the engine. ! Generac® Power Systems, Inc. 11 Section 3 – Maintenance QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 3.2 CHANGING THE ENGINE OIL AND/OR OIL FILTER 9. Start the engine and check for leaks. Figure 3.2 — Engine Oil Filter • Change the engine oil after the first 25 hours of operation (after the 25-hour break-in period, see Section 2.8.5, Page 10). Thereafter, change the oil every 100 operating hours. Change the oil more frequently if operating consistently under heavy load or at high ambient temperatures. • Change the engine oil filter after the first 25 hours of operation, and every 100 operating hours thereafter. To change the oil and/or oil filter, proceed as follows: 1. Run the engine until it is thoroughly warmed up (at least five minutes) then shut OFF the engine. 2. With the engine still warm from running, remove the oil drain plug (Figure 3.1). Drain the oil into a suitable container. Figure 3.1 — Oil Dipstick/Fill Tube and Location of Oil Drain Plug Oil Dipstick NOTE: Check the oil level and fill to the “FULL” mark after checking for leaks. The filter will retain some oil. 3.3 MAINTAINING THE ENGINE AIR CLEANER ◆ 3.3.1 CLEANING THE FOAM PRECLEANER Clean and re-oil the foam precleaner every three months or every 25 hours of operation, whichever occurs first. Service the foam precleaner more frequently if operating the generator in extremely dusty or dirty conditions. Use the following procedure (Figure 3.3): Oil Drain Hose 3. After the oil has drained, replace the oil drain plug. (If only changing the oil, go to step 7.) 4. With the oil drained, remove the old oil filter by turning it counterclockwise (Figure 3.2). 5. Apply a light coating of clean engine oil to the gasket of the new filter. 6. Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter. Then, tighten the filter an additional 3/4 to one turn. 7. Remove the dipstick and fill crankcase with the proper type and amount of recommended oil (see Section 1.6.2, Page 6). The engine crankcase can hold about 1.8 liters or 1.9 quarts with oil filter change. DO NOT FILL ABOVE THE “FULL” MARK. 8. Install and tighten the dipstick before operating the engine. 12 Generac® Power Systems, Inc. 1. Turn the knob counterclockwise to loosen. 2. Remove the cover, foam precleaner and paper filter. 3. Remove the foam precleaner from the cover. 4. Wash the foam precleaner in liquid detergent and water. 5. Wrap the foam precleaner in a clean cloth and gently squeeze it dry. 6. Saturate the foam precleaner in clean engine oil. Gently squeeze it in a clean cloth to remove excess oil and to distribute oil (DO NOT TWIST). 7. Install the foam precleaner into the cover, followed by the paper filter. Tabs at edges of paper filter must lock into slots on cover. 8. Install the cover, foam precleaner and paper filter. 9. Replace knob to retain the filter in place. Section 3 – Maintenance QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 3.3 – Engine Air Cleaner P l Flat Washer Figure 3.5 – Fuel Filter Wing Nut FUEL FILTER TO FUEL PUMP A Offset S x Compartment Wing Nut 3.4 CHECKING THE ENGINE SPARK PLUG Clean the spark plug and reset the spark plug gap every 100 hours of operation. 1. Clean the area around the base of the spark plug to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug to clean. 2. Remove the spark plug and check the condition. Replace the spark plug if worn or if reuse is questionable. 3. Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.030 inch (0.76 mm) by carefully bending the ground electrode (Figure 3.4). Figure 3.4 – Setting the Spark Plug Gap CUSTOMER FUEL CONNECTION 3.6 CLEAN SPARK ARRESTOR The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen every 50 hours of operation or once each year, whichever comes first. NOTE: If you use your generator on any forest-covered, brush-covered or grass-covered unimproved land, it must equipped with a spark arrestor. The spark arrestor must be maintained in good condition by the owner/operator. Clean and inspect the spark arrestor as follows: • Remove the screen retaining bracket by removing the screw. • Slide the spark arrestor screen out from the tail pipe. • Inspect screen and replace if torn, perforated or otherwise damaged. DO NOT USE a defective screen. If screen is not damaged, clean it with commercial solvent. • Replace the screen and the retaining bracket. Figure 3.6 - Spark Arrestor TAILPIPE P/N 0E0907 ! 3.5 Sparking can occur if the wire terminal does not fit firmly on the spark plug terminal end. If necessary, re-form the wire terminal to obtain a tight fit. FUEL FILTER (GASOLINE ONLY) Remove and replace the fuel filter (Figure 3.5) once each year or every 400 hours of operation, whichever comes first. RETAINER P/N 0D5133A SPARK ARRRESTOR SCREEN P/N 0D5133 RETAINING SCREW P/N 045764 Generac® Power Systems, Inc. 13 Section 3 – Maintenance QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 3.7 CLEANING THE GENERATOR Keep the generator set as clean and dry as possible. Protect the unit against excessive dust, dirt, corrosive vapors, road splash, etc. Permitting dirt and moisture to accumulate on generator windings will have an adverse effect on the insulation resistance of those windings. When moisture is allowed to remain in contact with windings, some of the moisture will be retained in voids and cracks in the insulation. This causes a reduced insulation resistance and will eventually cause problems. Dirt will make the problem worse, since dirt tends to hold moisture in contact with windings. Salt (as from sea air) also will worsen the problem since it tends to absorb moisture from the air. Salt and moisture, when combined, form a good electrical conductor. ! 3.8 Do NOT use a forceful spray of water to clean the generator. Water will enter the generator interior and cause problems, and may also contaminate the generator fuel system. BATTERY MAINTENANCE All lead-acid batteries will discharge when not in use. The generator battery should be inspected as follows: ◆ 3.8.1 WEEKLY • Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary. • Check the battery fluid level of unsealed batteries and, if necessary, fill with Distilled Water Only. Do not use tap water in batteries. ◆ 3.8.2 EVERY SIX MONTHS • Have the state of charge and condition checked. This should be done with an automotive-type battery hydrometer. NOTE: Servicing of the battery is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. Damage will result if the battery connections are made in reverse. 14 Generac® Power Systems, Inc. DANGER Do not dispose of the battery in a fire. The battery is capable of exploding. Storage batteries give off explosive hydrogen gas. This gas can form an explosive mixture around the battery for several hours after charging. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shatter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly ventilated. Do not allow smoking, open flame, sparks, or any spark producing tools or equipment near the battery. Discharge static electricity from your body before touching the battery by first touching a grounded metal surface. A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries: • Remove watches, rings or other metal objects; • Use tools with insulated handles; • Wear rubber gloves and boots; • Do not lay tools or metal parts on top of the battery; • Disconnect any charging source prior to connecting or disconnecting battery terminals; and • Do not use any jumper cables or booster battery to crank and start the generator engine. If any battery has discharged, remove it for recharging. Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin and eyes, and to be toxic. The electrolyte is a dilute sulfuric acid that is ! harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed: • Wear full eye protection and protective clothing; • Where electrolyte contacts the skin, wash it off immediately with water; • Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and • Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) or water. The bicarbonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried. ! Section 3 – Maintenance QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 3.9 MAJOR SERVICE MANUAL To obtain a service manual for your generator, contact your nearest Generac Authorized Service Dealer. Make sure to identify your MODEL NUMBER and SERIES. Manuals can be obtained from the internet website (www.generac.com) or a service dealer. 3.10 DRIVE BELT The engine drives the generator rotor by means of a pulley and drive belt arrangement. Drive belt tension was properly adjusted before the unit was shipped from the factory. If you suspect that drive belt tension is incorrect, contact a Generac Authorized Service Dealer. 3.11 EXERCISING THE GENERATOR Generac recommends that you start and operate the generator at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine. 3.12 OUT OF SERVICE PROCEDURE ◆ 3.12.1 REMOVAL FROM SERVICE If you cannot exercise the generator every seven days, and it is to be out of service longer than 30 days, prepare the generator for storage as follows: 1. Start the engine and let it warm up. 2. Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down. 3. While the engine is still warm from running, drain the oil completely. Refill the crankcase with SAE 5W-30 oil having API classification “For Service SF.” 4. Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase. 5. Remove the spark plug and pour two or three tablespoons of clean, fresh engine oil into the spark plug threaded openings. Reinstall and tighten the spark plug. 6. Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor. 7. Clean and wipe the entire generator. ◆ 3.12.2 RETURN TO SERVICE To return the unit to service after storage, proceed as follows: 1. Check the tag on the engine for oil viscosity and classification. Verify that the correct recommended oil is used in the engine (see Section 1.5.4, Page 6). If necessary, drain and refill with the proper oil. 2. Check the state of the battery. Fill all cells of unsealed batteries to the proper level with distilled water. DO NOT USE TAP WATER IN THE BATTERY. Recharge the battery to 100 percent state of charge, or, if defective, replace the battery. 3. Clean and wipe the entire generator. 4. Reconnect the battery. Observe battery polarity. Damage may occur if the battery is connected incorrectly. 5. Turn OFF all electrical loads. Add fuel if necessary and then start the engine. 6. Allow the unit to warm up thoroughly. 7. Apply electrical loads to at least 50 percent of the unit’s rated wattage capacity. 8. When the engine is thoroughly warmed up, shut it down. 9. Your generator is now ready for service. 3.13 RV GENERATOR SERVICE INTERVAL QUIETPACT 55/65/75: 50 Hours ................................Clean Spark Arrestor 1st 50 Hours, then every 500 Hours ................Adjust Valve Lash 100 Hours..........................Change Engine Oil/Filter 100 Hours ..................................Clean Air Pre-filter 100 Hours ................................Inspect Spark Plugs 250 Hours ............Replace Paper Air Filter Element 400 Hours ..................................Replace Fuel Filter 500 Hours................................Replace Spark Plugs Generac® Power Systems, Inc. 15 Section 4 – Notes QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 16 Generac® Power Systems, Inc. PART II – INSTALLATION INSTRUCTIONS DANGER ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!! Safety Rules QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ! DANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with article 551, NFPA 70; ANSI C1-1975; AND, ANSI A119.2-1975/NFPA 501C “Standard for Recreational Vehicles” (Part 3, “Installation of Electrical Systems”). In addition, installation must comply with the manufacturer’s instructions and recommendations. NOTICE TO INSTALLER These Installation Instructions have been published by Generac to aid in the installation of the products described in this manual. Generac assumes that installation personnel are familiar with the procedures for installing such products, or similar products that Generac manufactures. Generac also assumes that personnel have been trained in the recommended installation procedures for these products and that such training includes (a) use of common hand tools, (b) use of special Generac tools, and (c) use of any tools and/or equipment from other suppliers. Generac cannot possibly know of and advise the recreational vehicle trade of all conceivable methods, procedures or techniques by which to perform an installation. Nor can Generac anticipate every possible hazard that might result from each installation method, procedure or technique. Generac has not undertaken any such wide evaluation. Therefore, people who use a method, procedure or technique that Generac does not specifically recommend must first completely satisfy themselves that their safety, the safety of the vehicle's occupants and the product's safety is not endangered by the method, procedure or technique selected. Information, illustrations, specifications, etc., contained in these Installation Instructions are based on the latest information available at the time of publication. Every effort has been expended to be sure that such data is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve this product at any time without prior notice. DANGER ! Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment. Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator. ! Parts of the generator are rotating and/or hot during operation. Exercise care near running generators. 18 Generac® Power Systems, Inc. ! GENERAL HAZARDS ! • For safety reasons, Generac recommends that the installation, initial start-up and maintenance of this equipment is carried out by a Generac Authorized Service Dealer. • The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently, (b) nausea, (c) vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weakness, and (i) sleepiness. IF YOU EXPERIENCE ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired. • Never sleep in the vehicle while the genset is running unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area. • Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating. • Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. • When working on this equipment, remain alert at all times. Never work on the equipment when you are physically or mentally fatigued. • Before performing any maintenance on the generator, disconnect its battery cables to prevent accidental start up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last. Safety Rules QUIETPACT 55, 65, and 75 Recreational Vehicle Generators • Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc. • Never insert any tool or other object through openings in the generator interior, even if the unit is not running. You might seriously injure yourself or damage the equipment. ELECTRICAL HAZARDS • The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If you must work around an operating unit, stand on an insulated, dry surface to reduce shock hazard. • Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT. • During installation onto the vehicle, properly ground (bond) the generator either by solid mounting to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT connect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum. • If the vehicle electrical circuits can be powered by any other source of electricity (such as a “dockside” power receptacle), there must be no possibility of connecting the different power sources to the vehicle circuits at the same time. The dockside (utility) power source must be positively isolated from the vehicle circuits whenever the generator is operating. Failure to isolate the vehicle circuits from the dockside power supply when the generator is running may result in damage to the generator or serious injury or death to dockside (utility) power workers due to backfeed of electrical energy. • In case of accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting implement, such as a rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help. • Never wear jewelry when working on this equipment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving components causing injury. FIRE HAZARDS • For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installation, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regulations. • Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged and be familiar with its use. If you have any question pertaining to fire extinguishers, consult your local fire department. EXPLOSION HAZARDS • Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left in the generator compartment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris. • Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws governing the storage and handling of gasoline. • Fuel lines must be properly installed and fastened, and free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior. • You are required to install an approved, flexible, nonconductive fuel line between the generator fuel connection point and rigid fuel lines. • If the generator is equipped with a liquid propane (LP) gas fuel system, install the unit so it complies with all codes, standards and regulations pertaining to such systems. LP gas is highly explosive. The gas tends to settle in low areas where even the slightest spark can ignite it and cause an explosion. Do not allow gas vapors to enter the vehicle. Generac® Power Systems, Inc. 19 Section 5 – General Information QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 5.1 PURPOSE AND SCOPE OF THE INSTALLATION INSTRUCTIONS These Installation Instructions have been prepared especially for the purpose of familiarizing installers and owners of the applicable equipment with the product's installation requirements. Give serious consideration to all information and instructions in the manual, both for safety and for continued reliable operation of the equipment. Because of the different recreational vehicle models and the variations between the models, it would be extremely difficult, if not impractical, to provide detailed instructions for every possible installation. For that reason, instructions and illustrations in this manual are general in nature. Illustrations are not intended to serve as detailed installation blueprints. The installation should comply strictly with all applicable codes, standards and regulations pertaining to the installation and use of this product. If any portion of this manual appears to be in conflict with such codes, standards or regulations, the applicable codes, standards or regulations must take precedence over the manual. 5.2 SAFETY Before handling, installing, operating or servicing this equipment, carefully read the “Notice to Installer” and “Safety Rules” on Pages 18 and 19. Comply with all safety rules to prevent death, personal injury or damage to equipment and/or property. Stress safety to all installers, operators and service technicians who work on this equipment. 5.3 STANDARDS BOOKLETS Installation, use and servicing of this equipment should comply strictly with published standards, as well as the manufacturer's recommendations. The following standards booklets (latest revision) are available from the sources indicated: 1. NFPA Standard 501C, “Standard for Recreational Vehicles,” available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 2. NFPA 70, “NFPA Handbook of the National Electric Code,” available same as Item 1. 3. ANSI C1-1975 and ANSI 119.2-1975, available from the American National Standards Institute, 1430 Broadway, New York, NY 10018. 4. ANSI A119.2/NFPA 501C, available from the Recreational Vehicle Association, 1896 Preston White Drive, Reston, VA 22090. 5. California Administrative Code, Title 25, available from the State of California, Documents Section, P.O. Box 1015, North Highlands, CA 95660. 20 Generac® Power Systems, Inc. 6. CSA Electrical Bulletin 946, available from the Canadian Standards Association, Housing and Constructions Materials Section, 178 Rexdale Boulevard, Rexdale, Ontario, Canada, M9W 1R3. 5.4 EQUIPMENT DESCRIPTION Instructions and information in this section pertain to Generac air-cooled generators. These generators are designed specifically for installing in recreational vehicles. They operate 120-volt, single-phase, 60Hertz, AC electrical loads. 5.5 GENERATOR ENGINE OPERATING SPEED The generator’s revolving field (rotor) is driven by a single-cylinder, four-cycle engine through a pulley and drive belt arrangement. The generator supplies 120 volts AC at 60 Hertz when the rotor is operating at 3,600 rpm.The drive belt arrangement allows the engine to operate at a lower speed than the rotor. 5.6 GENERATOR AC CONNECTION SYSTEM These air-cooled generator sets are equipped with dual stator AC power windings. These two stator windings supply electrical power to customer electrical loads by means of a dual 2-wire connection system. Generators may be installed to provide the following outputs: 1) 120 VAC loads only — one load with a maximum total wattage requirement equal to the generator’s rated power output (in watts), and 120V across the generator output terminals. (See Fig. 5.1 below) 2) 120/240 VAC loads — one load with a maximum total wattage requirement equal to the generator’s rated power output, and 240 V across the generator output terminals; or two seperate loads, each with a maximum total wattage requirement equal to half of the generator’s rated power output (in watts), and 120 V across the generator output terminals. (See Fig. 5.3 on page 22) Figure 5.1 – Connection for 120 Volts Only 526.2 516.2 TYP. 495 A 497.4 469.8 TYP. 25.4 TAILPIPE LOCATION HOT AIR EXHAUST 226.5 183.5 95.5 TYP. 45˚ 344.6 POWERED BY GUARDIAN 760cc OHVI V-TWIN QUIETPACT 855.8 834.9 FRONT DOOR ACCESS FOR ALL REQUIRED MAINTENANCE 574.7 545 3/8"-16 WELDNUTS (8 PLACES) 70.8 305.9 195.8 821.2 INDUSTRIAL 55G 469 FRONT 233.2 57 126.2 FUEL INLET 90 FUEL INLET AIR INTAKE 54 TYP. 536.2 212 84 AC OUTPUT HARNESS 39.8 REMOTE PANEL CONNECTOR 564.1 VIEW FROM TOP 89.4 120.5 190.4 513.7 470 FUEL FILTER BATTERY CONNECTIONS 50 TYP. NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS MUST BE KEPT CLEAR OF ANY OBSTRUCTIONS. ALL OPEN AREA IS REQUIRED FOR COOLING. Section 5 – General Information QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 5.2 - Major Features and Dimensions (Drawing No. 0E1058-A) Generac® Power Systems, Inc. 21 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 5.3 - Connection for 120/240 Volts CB1 T1 RED T2 WHITE • The location must provide sufficient room to allow minimum clearances as outlined in Section 6.2. If sound insulation is to be used on the compartment walls and ceiling, the minimum recommended applies to the space between the generator and such insulation. • The location must provide adequate cooling and ventilating airflow for the generator without a great deal of work and expense. ◆ 6.1.2 GENERATOR SUPPORT CB2 STATOR WINDINGS T3 BLACK GROUNDED NEUTRAL • The AC connection system on all air-cooled PRIMEPACT series generators uses a GROUNDED neutral. • A separate green ground wire is connected to the recreational vehicle’s junction box. • Loads connected across T1 (Red) to T2 (White), and T3 (Black) to T2 (White), must not exceed ratings for your specific generator (see Section 1.6.3). NOTE: Do NOT connect loads in excess of circuit breaker ratings. 6.1 LOCATION AND SUPPORT ◆ 6.1.1 GENERATOR LOCATION The most desirable location for the generator set is between the vehicle's main frame members. However, this is seldom possible. Most units must be installed on the side of the vehicle and are difficult to reinforce. Many recreational vehicles have been factory equipped with an area for the generator set. Some vehicles may even have a generator compartment provided by the vehicle manufacturer. Plan the generator location based on the following: • The generator set must be installed on a framework that is part of the recreational vehicle, as outlined in Section 6.1.2. • The location must provide an access opening that is large enough to permit generator removal (unless the generator is to be removed from underneath the supporting framework). • The location must provide easy access to frequently serviced components, such as filters, oil drains, spark plugs and other common maintenance parts. 22 Generac® Power Systems, Inc. The generator must be securely attached to a metal framework that has been made part of the vehicle frame structure by bolting or welding. The metal framework on which the generator will rest and which will restrain the generator set should consist of at least two horizontal beams. These beams should consist of (a) 1-1/2-inch square, 11-gauge steel tubing OR (b) 1-1/2-inch, 11-gauge angle iron. A typical supporting frame with horizontal support tubing, is shown in Figure 6.1. The generator can be installed so that it sits on top of the horizontal support tubing if the vehicle design permits. Another method is to suspend the generator below the horizontal support tubing by means of suitable, structurally sound metal framework. The following general rules apply: • Vehicle construction MUST be capable of supporting the weight of the generator. • Whether the generator is mounted above the horizontal support tubing or suspended below the tubing, the supporting frame used must be structurally sound. • If the generator cannot be bolted directly to the supporting frame or support tubing, consider using additional tubing, angle brackets or other supports to give the supporting frame sufficient strength. Figure 6.1 – Typical Horizontal Support Frame Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 6.1.3 SUSPENDED MOUNTING If you are going to suspend the generator below the horizontal support tubing, the suspension method you use with the vehicle frame members must (a) be able to support the weight of the generator AND (b) provide sufficient restraint for the generator. One typical suspended mounting system is shown in Figure 6.2. The location of a suspended mounting system must be carefully planned, keeping the following general rules in mind: • Protect the generator against road splash and debris. Baffles or splash guards may be required to protect certain areas of the generator. To make sure the generator is adequately protected, road test the installation through mud, water and slush. Figure 6.2 – Typical Suspended Mounting System 6.2 GENERATOR COMPARTMENTS Whether the generator set is being installed inside a compartment specifically manufactured to house a generator or inside a compartment that the installer constructs, the compartment MUST meet certain specifications as outlined in the following sections: ◆ 6.2.1 COMPARTMENT SIZE Plan the compartment size carefully. Provide a minimum clearance of 1/2 inch (13 mm) on the front and top, 1 inch (25 mm) on the sides, and 1/2 inch (13 mm) from the back for air circulation AFTER the compartment has been lined with metal and sound insulation (Figure 6.4). NOTE: Refer to “Figure 5.2 – Major Features and Dimensions” on Page 21. Figure 6.4 – Clearances Plywood Compartment 1/2" Clearance on Top 1" Clearance in Back QUIETPACT 55G POWERED BY GUARDIAN 760cc OHVI V-TWIN INDUSTRIAL 1" Each Side Insulation 1/2" in Front • The installer must make certain that the selected location will permit adequate cooling and ventilating airflow to be supplied. ◆ 6.1.4 GENERATOR RESTRAINT Use four 3/8"-16 hardened steel bolts (Grade 5) to fasten the generator to the supporting frame or the support tubing. These bolts must pass through (a) the generator mounting base, (b) the compartment floor (if a compartment is used) and (c) the supporting framework (Figure 6.3). All bolts must be long enough so that when tight, at least three threads are visible past the retaining lock nuts. Refer to Section 6.2 for the location of the generator mounting holes. Figure 6.3 – Typical Generator Restraint ◆ 6.2.2 COMPARTMENT CONSTRUCTION • The generator compartment should be either constructed of, or lined with, 26-gauge galvanized steel. NOTE: Aluminum is NOT an acceptable alternative to galvanized steel due to aluminum’s low melting point. • If the compartment is lined with galvanized steel, it may be constructed of any material. Generac recommends that the compartment be constructed of 1/2-inch thick plywood (not strandboard), with the floor made of a double thickness of 1/2-inch plywood with the grain of the wood at cross section for added strength (Figure 6.5). Generac® Power Systems, Inc. 23 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 6.5 – Typical Compartment Construction Figure 6.6 – Types of Lock Seams • After the compartment has been metal lined and vapor sealed, line the compartment interior walls and ceiling with an approved, nonflammable sound insulating material. See Section 6.2.3. • If constructing a compartment, line the exterior (underside) of the compartment floor with 26gauge galvanized steel. • All seams, splices and joints of the compartment walls (unless vapor tight by design) should be caulked to prevent poisonous, flammable or explosive vapors from entering the vehicle interior. NOTE: Caulking must be done so that the caulking material will stay in place permanently. Pressing such materials as putty tape onto joints and seams is not acceptable. A high quality silicone rubber base sealant is recommended. • Holes and openings made in the compartment walls to allow for the passage of electrical conduit, conductors, hoses, cables, etc., into the vehicle living area must be sealed vapor tight with silicone rubber base sealant. • If flexible metal conduit is used, it must be sealed internally at the end where it terminates inside the compartment’s electrical junction box. NOTE: Flexible metal conduit, due to its unique construction, is NOT vapor tight along its entire length. • Seams and joints of the galvanized steel (whether used as a liner or for the compartment itself) must be lapped and mechanically secured. Such seams may be manufactured, welded, bolted, riveted or screwed. Manufactured lock seams are shown in Figure 6.6. Installer constructed compartments typically utilize a standard lap joint. 24 Generac® Power Systems, Inc. DANGER Do not install any flammable material directly above or around the compartment. Heat, transferred through the compartment structure, may be sufficient to ignite, char or discolor seat cushions, fiberboard and other flammable materials. You may need to use approved nonflammable insulating materials in high temperature areas. ◆ 6.2.3 SOUND INSULATING MATERIALS Once installers have determined that a compartment is properly constructed and metal lined, they can add acoustical material. This may include additional sealant or insulating material, to reflect noise away from the vehicle interior. Sound insulating materials should be of a nonflammable type. One excellent insulating material is a 1inch (25 mm) thick fiberglass having a 2-pound density. When fiberglass is used, its coated side should face toward the compartment interior. DANGER Do not install sound insulation or any absorbent material on the compartment floor interior. Such materials will become soaked with combustible or explosive vapors and liquids and will become a fire hazard. Using a combination of sound insulating materials can often reduce noise more effectively than a single material. For example, a sheet of lead or visco-elastic material, along with a layer of other acoustical material, is more effective than when a single material is used. Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 6.2.4 ACOUSTICS ◆ 6.2.5 COMPARTMENT FLOOR CUTOUTS For additional noise abatement, the installer may wish to consider the following: You must provide openings in the generator compartment for the following items (Figure 6.8, Page 26): • Using special sound insulating materials. • Construction of a special noise abatement compartment. NOTE: • Engine exhaust and cooling air outlets • Generator cooling air inlet • Four holes for passage of generator mounting bolts. See Section 6.1.4 (Page 23). Any method used to reduce noise must not adversely affect the flow of cooling and ventilating air into or out of the compartment. DANGER In addition to the effective use of sound insulating materials, construction of a special noise abatement compartment might be considered to reduce noise levels. Such a compartment might be constructed as follows (Figure 6.7): • Use 5/8-inch thick or 3/4-inch thick plywood in the compartment. • Construct the compartment floor of a double thickness of 5/8-inch or 3/4-inch plywood. • Line the compartment interior walls and floor, as well as the underside of the floor, with 26-gauge galvanized steel. • Vapor seal all compartment seams and joints. • Over the galvanized steel lining, install a combination of acoustical materials as mentioned in Section 6.2.3. DANGER To prevent fire or explosion, do not install any insulation or other absorbent materials on the interior or underside of the compartment floor. • Seal all compartment door edges to prevent noise leakage around the door perimeter. • Line the compartment door interior (except for air openings) with suitable, fireproof sound insulation (such as 1-inch (25 mm) thick fiberglass with a 2pound density). Figure 6.7 – Typical Noise Abatement Fuel lines and exhaust piping must not pene- ! trate into the vehicle living area. 6.3 COOLING AND VENTILATING AIR It is absolutely essential that an adequate flow of air for cooling, ventilating and engine combustion be supplied to the generator set. Without sufficient airflow, the engine/generator quickly overheats. Such overheating can cause serious operating difficulties and also may cause fire and personal injury. The installer must make sure that sufficient air is available to the generator for cooling, ventilating and combustion. The installer also must provide for a path for exhausting the cooling air to the exterior of a compartment, if so equipped. DANGER Never use discharged cooling air for heating or permit such air to enter the vehicle interior. This air contains deadly carbon monoxide gas and other poisonous, flammable or explosive gases. ◆ 6.3.1 GENERATOR AIRFLOW Engine operation drives cooling fans for the two-stage cooling air system. A pressure fan draws cooling air into the top of the generator (Figure 6.9). This airflow cools the engine/generator and electronic components. The second part of the cooling system, a suction fan, draws air that is heated from a hot engine into a collector pan at the base of the unit. This heated air (although cooler than exhaust muffler) is then deflected out the bottom toward the ground. Figure 6.9 – Airflow Through Engine/Generator GUARDIA by Generac Power Syste QUIETPACT 55G INDUSTRIAL Generac® Power Systems, Inc. 25 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 6.8 — Compartment Floor Cutout HOT AIR EXHAUST 821.2 TAILPIPE 469 195.8 25.4 VIEW FROM TOP 233.2 4 YP. 45˚ 526.2 AIR INTAKE 516.2 TYP. 536.2 564.1 344.6 305.9 FUEL INLET 90 70.8 126.2 57 5 3/8"-16 WELDNUTS (8 PLACES) 226.5 545 FRONT 574.7 834.9 NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS MUST BE KEPT CLEAR OF ANY OBSTRUCTIONS. ALL OPEN AREA IS REQUIRED FOR COOLING. ◆ 6.3.2 TESTING THE INSTALLATION Generac recommends testing the installation to be sure adequate cooling airflow is available to the unit before placing the unit into service. If the unit shows signs of overheating, you will need to enlarge the air openings. Never place a unit into service until absolutely certain that cooling and ventilation is adequate. The installation of a gasoline fuel system (Figure 6.14) for a recreational vehicle generator set must comply with applicable codes, standards and regulations. The entire fuel system must be completely free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior. Figure 6.14 – Generator Fuel System NOTE: You must test the installation, especially if you bring in air from below the generator set. 6.4 Fuel Pump (Behind Access Cover) GASOLINE FUEL SYSTEM Fuel Filter (Side of Unit) DANGER Gasoline is highly flammable, and its vapors are explosive. Comply with all codes, standards and regulations pertaining to gasoline fuel systems used in recreational vehicle generators. Properly install and maintain the fuel system and keep it entirely free of leaks. Gasoline vapors must not enter the vehicle interior. 26 Generac® Power Systems, Inc. Fuel Line Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Factory installed generator fuel system components include (a) fuel filter, (b) 12-volt DC electric pump, (c) engine carburetor, and (d) interconnecting lines and fittings. Connect a fuel supply line to the fuel filter inlet. Use a flexible length of approved fuel hose between the fuel filter inlet connection and rigid fuel lines. ◆ 6.4.1 FUEL TANK Either the generator must share the vehicle engine's fuel tank, or you must install a separate fuel tank for the generator set. All fuel tanks installed on the vehicle must be constructed, installed and restrained so they comply with applicable codes, standards and regulations. If the generator is to share the vehicle engine's tank, separate fuel pickup tubes are required for the engine and the generator. Generac recommends that you make the fuel pickup tube 2 to 3 inches (51 to 76 mm) shorter than the vehicle engine's pickup tube. This prevents the generator from depleting the entire fuel supply during prolonged generator operating periods. ! Do NOT tee the generator fuel supply line into the vehicle engine fuel supply line. If this is done, the generator will be starved of fuel when both engines are operating at the same time. Also, while the vehicle engine is not running, generator operation may drain the vehicle engine supply line, making it difficult to start the vehicle engine. ◆ 6.4.2 GENERATOR FUEL SUPPLY LINE 6.4.2.1 Rigid Fuel Lines Those lines used to supply fuel from a tank to the generator must comply with applicable codes, standards and regulations. The following general rules apply to rigid fuel lines: • Rigid lines should be of annealed, seamless, drawn aluminum or steel. • Lines and fittings must comply with SAE J512F, “Standard Automotive Fittings,” or with ANSI B126.26 (latest edition). • Route the fuel line so that at least 2 inches (51 mm) of clearance is maintained between the line and any exhaust system parts. • Do not attach electrical wiring to fuel lines. Route the wiring so it cannot come into contact with any fuel line. • Route fuel lines so if they leak, fuel does not drip onto any electrical or exhaust system parts. • Use nonferrous metal straps without sharp edges to secure fuel lines. 6.4.2.2 Flexible Fuel Line Use an approved flexible length of fuel hose between the generator fuel inlet connection and rigid fuel lines. This prevents breaking of the line caused by vibration, shifting, settling or movement. The following rules apply: • The flexible hose must comply with SAE J30B, “Standard for Fuel and Oil Hose.” It must be approved for use with gasoline. • The hose should be at least 6 inches (152 mm) longer than is needed to prevent the hose from rupturing if the generator shifts or settles. 6.5 LP GAS FUEL SYSTEM DANGER LP gas is highly EXPLOSIVE. The gas is heavier than air and tends to settle in low areas. Even the slightest spark can ignite it and cause and explosion. Only competent, qualified people should be allowed to install, test, adjust or service an LP gas fuel system. Install the optional fuel system in compliance with applicable codes, standards and regulations. After the installation, do not do anything that might render the system in noncompliance with applicable codes and standards. The LP powered range of generators are fitted with a nonadjustable, factory set system. These systems are tamper-proof to meet 1997 California Air Resources Board requirements for engine emission. ◆ 6.5.1 LP FUEL CONSUMPTION (lb./hour) Model Idle 50% Load 100% Load Quietpact 55LP Quietpact 65LP Quietpact 75LP 2.34 2.34 2.34 3.96 4.20 4.44 5.07 6.50 8.75 ◆ 6.5.2 PARTS NOT INCLUDED IN FUEL SYSTEM The propane fuel system does NOT include such items as (a) gas tank, (b) gas piping, (c) fittings, (d) valves, and (e) primary regulator, used to store the gaseous fuel and deliver it to the gaseous fuel solenoid (Figure 2.15, Page 29). DANGER Use only approved components in the fuel supply system. All components must be properly installed in accordance with applicable codes. Improper installation or use of unauthorized components may result in fire or an explosion. Follow approved methods to test the system for leaks. No leakage is permitted. Do not allow fuel vapors to enter the vehicle interior. Generac® Power Systems, Inc. 27 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 6.15 – Typical Propane Gas Fuel System ◆ 6.5.5 PRIMARY REGULATOR Gas pressure delivered to the solenoid valve must be properly regulated by means of a primary gas regulator. Mount the primary regulator at the gas tank outlet or in the supply line from the gas tank. The following rules apply: • For best results, the primary regulator supplies gaseous fuel to the secondary regulator at 11 inches water column. Do NOT exceed 14 inches water column. • The installer must be sure the primary regulator is rated at sufficient gas flow to operate the generator plus all other gas appliances in the circuit. NOTE: Recommended MINIMUM gas flow rate for all aircooled PRIMEPACT series generators is 67 cubic feet per hour. ◆ 6.5.3 SOME IMPORTANT CONSIDERATIONS When installing an LP gas system, consider seriously the following items: • All fittings, lines, hoses and clamps must be tight and free of leaks. Apply a pipe sealant to threads when assembling threaded connections. This reduces the possibility of leakage. • Test the entire fuel system for leaks using approved test methods. • Optimum gas pressure at the inlet to the gaseous fuel solenoid valve and secondary regulator is 11 inches water column. • The installer’s fuel supply connection point is at the gaseous fuel solenoid valve. This is a 3/4-inch (female) connection. Provide a suitable 3/4-inch NPT (male) connector to attach to the fuel supply line. • Use a length of approved flexible fuel hose between the gaseous fuel solenoid valve and rigid gas piping. The flexible line should be at least 6 inches longer than necessary. ◆ 6.5.4 VAPOR WITHDRAWAL LP gas is stored in pressure tanks as a liquid. The gas systems used with these generators were designed only for vapor withdrawal type systems. Vapor withdrawal systems use the gas vapors that form above the liquid fuel in the tank. Do NOT attempt to use the generator with any liquid withdrawal type system. 28 Generac® Power Systems, Inc. If an existing primary gas regulator does not have a sufficient flow capacity for the generator and other gas appliances in the circuit, (a) install a primary regulator with adequate flow rate, or (b) install a separate regulator only and rated at least 67 cubic feet per hour. The inlet side of any primary regulator that supplies the generator must connect directly to a gas pressure tank. Do NOT tee the generator line into a gas circuit feeding other areas. ◆ 6.5.6 GASEOUS CARBURETION LP gas vapors should be supplied to the secondary regulator inlet at about 11 inches water column (positive pressure). The engine pistons draw air in during the intake stroke (Figure 6.16). This air passes through a carburetor venturi, which creates a low pressure that is proportional to the quantity of air being pumped. The low pressure from the carburetor venturi acts on the regulator diaphragm to pull the diaphragm toward the source of low pressure. A lever attached to the diaphragm opens a valve to permit gas glow through the carburetor. Figure 6.16 – LP Gas Carburetion Diagram Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators The greater the airflow through the carburetor venturi, the lower the pressure at the venturi throat. The lower the pressure at the venturi throat, the greater the diaphragm movement, and the greater the movement of the regulator valve. The more the regulator valve opens, the greater the gas flow that is proportional to airflow through the generator. The following facts about the secondary regulator must be emphasized: • The regulator must be sensitive to venturi throat pressure changes throughout the operating range. • The regulator must be properly adjusted so it will stop the flow of gas when the engine is not running (no air flow through the carburetor). • The slightest airflow (and vacuum in the venturi throat) should move the regulator valve off its seat and permit gas to flow. ◆ 6.5.7 FUEL SUPPLY LINES • LP gas lines must be accessible, but protected against possible damage. • Do NOT connect electrical wiring to any LP gas fuel line or run wiring alongside the lines. • Route gas lines away from hot engine exhausts. • Retain gas lines with metal clamps that do not have sharp edges. • Install an approved length of flexible hose between the gaseous fuel solenoid valve and rigid fuel supply lines. The flexible line must be nonmetallic, nonorganic and nonconductive. It must be approved for use with LP gas. ◆ 6.5.9 LEAKAGE TESTS Do not place the generator into service until you have properly tested the gas system for leaks. To test the system, you need a separate source of 12 volts DC to open the gaseous fuel solenoid valve. The leak test must comply fully with NFPA, Paragraph 318. All connections, hoses, valve regulators, fittings, and other fuel system parts must be tested under gas or air pressure of not less than 90 psi (620 kPa), while using soap and water or an equivalent solution to check for leaks. Other approved methods of testing for leaks may be used, if appropriate. DO NOT USE ANY FLAME TO TEST FOR LEAKS. 6.6 EXHAUST SYSTEM The generator exhaust system must be safely and properly installed. Only approved mufflers and other exhaust system parts must be used. A properly installed exhaust system must be vapor tight, quiet and completely safe. DANGER ! The generator engine gives off DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently; (b) vomiting; (c) twitching muscles; (d) throbbing temples; (e) dizziness; (f) headaches; (g) weakness; and (h) sleepiness. IF YOU FEEL ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Do not operate the generator until its exhaust system has been inspected and properly repaired. ! Never tee the generator engine exhaust pipe into the vehicle engine exhaust piping. This causes excessive back pressure on the generator engine. Also, water from one engine can damage the other engine. DANGER Gaseous fuel lines between the tank and the secondary regulator are under a positive pressure (about 11 inches water column). Gas pressure at the outlet side of the secondary regulator, however, is a negative pressure and can draw flame inside a line or fitting and cause an explosion. ◆ 6.5.8 EXCESS FLOW VALVE LP gas tanks should have an excess flow valve, according to NFPA 501C, Paragraph 3-4.4. This valve and the gas lines must be carefully sized so the valve will close when a fuel line is severed or broken. Consult the Natural-LP Gas Association for information and limitations of excess flow valves. Manual shutoff valves on the supply tank and elsewhere in the system must be fully open when operating the generator. The excess flow valve functions properly only if all valves are fully open. Generac® Power Systems, Inc. 29 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 6.6.1 MUFFLERS AND SPARK ARRESTORS This muffler meets code and standard requirements of the U.S. Forest Service. Use only mufflers and parts approved by Generac. Any person(s) installing an unapproved muffler, or an unapproved exhaust system part, or modifying an exhaust system in any way that might cause a hazard, is liable for any damage, injury or warranty expense that might be caused by such unapproved installation or modification. Failure to provide and maintain a spark arrestor may be in violation of the law. If this generator is used on any forest covered, brush covered or grass covered unimproved land, you must provide a spark arrestor. The vehicle owner or operator must maintain this device in good condition. In the state of California, the preceding is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. When installing/replacing the tailpipe or spark arrestor components, verify that the tailpipe has a hole to securely fasten the spark arrestor components (see Figure 6.17). Use only Generac supplied hardware. Substitution of parts may cause damage to the screen or a loose fit to the tailpipe. Figure 6.17 — Spark Arrestor Installation • If there is any possibility of the tailpipe or muffler being damaged, protect these damage-prone areas by means of a protective device (such as a skid bar). • Install the generator exhaust system according to safe automotive practices. • Use enough exhaust system hangers to prevent any part of the system from being dislocated. • Use exhaust system parts recommended by Generac. Using unapproved exhaust mufflers and exhaust system parts is the responsibility of the person(s) installing such unauthorized parts. • Do not terminate the exhaust system under any opening, window or vent that can be opened or is not permanently sealed from the vehicle interior. • Exhaust piping must be large enough to prevent excessive back pressure on the generator engine. • Never tee the generator engine exhaust pipe into the vehicle engine exhaust piping. This causes excessive back pressure on the generator engine. Also, water from one engine can damage the other engine. • Plan exhaust system installation carefully. Comply with all applicable codes, standards and regulations. 6.7 ELECTRICAL CONNECTIONS Be sure to read Section 5.6 on Page 20. The following general rules apply to electrical connections in a recreational vehicle: 38.1 [1.50"] 5 O.D. 24 [0.95"] 3.5 [[9/64"]] DRILL BOTTOM SIDE ONLY ◆ 6.6.2 EXHAUST SYSTEM SAFETY • Maintain a clearance of at least 3 inches (76 mm) between exhaust system parts and any combustible material (such as wood, felt, cotton, organic fibers or other like material). If you cannot maintain the 3-inch (76 mm) clearance, locate, insulate or shield the exhaust part(s) so that the temperature of any combustible material is not raised more than 117° F (65° C) above the ambient air temperature. • Extend the exhaust system at least 1 inch (25 mm) past the outer edge of the vehicle. Do not terminate the exhaust system under the vehicle. • Terminate the exhaust tailpipe such that exhaust gases will not be drawn back into the generator compartment and recirculated. 30 Generac® Power Systems, Inc. • Qualified electricians who are familiar with applicable codes, standards and regulations should install electrical wiring. • The wiring should comply with codes, standards and regulations. The National Electrical Code (NFPA 70), and state and local codes apply. • Switches and circuit breakers should be of a type approved for use in recreational vehicles and must be mounted and installed to prevent damage from road shock. • Wiring must be of adequate size, have approved insulative qualities and be properly supported. • Conduit and wire openings into the generator compartment (if used) must be vapor-sealed to prevent entry of flammable, explosive or poisonous gases into the vehicle. ◆ 6.7.1 ELECTRICAL JUNCTION BOX Install an approved, square electrical junction box with a blank cover on the interior or exterior wall of the area you plan to install the generator (NOT on the generator). Route the generator's AC output leads into this junction box through approved flexible conduit. This is the point of first termination for generator AC output leads. Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 6.7.2 WIRING • Wiring should be of stranded copper to reduce the chance that vibration may cause breakage. • Wire gauge size should be large enough to handle at least 115 percent of the installed generator's rated maximum current. • If neutral conductors are used, they must be the same size as other leg wires. • Route power supply conductors from generator AC output leads T1 (red), T2 (white), T3 (black) and the green ground wire through approved flexible conduit to the electrical junction box on the compartment wall. • If flexible metal conduit is used between the generator and the compartment junction box, the conduit end that terminates the compartment junction box must be vapor-sealed. Flexible metal conduit is NOT vapor tight along its entire length. • From the junction box, route power supply wires through approved conduit to either (a) doublepole, double-throw transfer switch, or (b) approved isolation receptacle. Connecting to a transfer switch or isolation receptacle must prevent vehicle electrical circuits from being connected to two different power supplies at the same time (such as generator and dockside power). • Conductors must be rated 221° F (105° C) or must be of a larger conductor size. ◆ 6.7.3 GENERATOR AC CONNECTIONS Generator AC output leads T1 (red), T2 (white) and T3 (black) come out of the generator as shown in Figure 6.18. Leads T1 (red) and T3 (black) are “hot,” while T2 (white) is the grounded neutral lead. There is also a green lead that connects to ground in the junction box of the recreational vehicle. Figure 6.18 – Generator AC Output Leads Line T1 (red) to T2 (white) is protected against overload by a circuit breaker (CB1). Use this line-to-neutral connection separately to operate 120-volt, singlephase, 60 Hertz, AC loads. Line T3 (black) to T2 (white) also is protected against overload by a circuit breaker (CB2). Use this line-to-neutral connection separately to operate similar loads. However, be sure the total unit load does not exceed the maximum rating of the generator. The neutral line (T2, white) on all units is a grounded neutral. Do NOT connect electrical loads in excess of any circuit breaker rating or you will develop problems with circuit breaker tripping, which causes a loss of AC output. Also, do NOT exceed the generator's rated wattage capacity. Add the watts or amperes of all lighting, appliance, tool and motor loads the generator will operate at one time. This total should be less than the unit's rated wattage/amperage capacity. ◆ 6.7.4 CONDUIT Route the connections between the generator and the junction box through approved, flexible conduit. The following general rules apply: • Cut wiring to the required length and allow extra wire for junction box connections. • Carefully prepare conduit ends to prevent sharp edges from cutting through wiring insulation. • Route conduit so it does not interfere with generator movement. • If you use metallic conduit, vapor seal the end of the conduit where it enters the junction box. Do this because flexible metallic conduit is not vaporproof along its entire length. ◆ 6.7.5 ISOLATING DIFFERENT POWER SOURCES T3 T2 T1 Green (Ground) Connections from the junction box must terminate in a double-pole, double-throw transfer switch (Figure 6.19, Page 33). An alternate method for isolating different power sources is by using an isolating receptacle (Figure 6.20, Page 33). Whichever method you use, you must be certain that both power sources are NOT connected at the same time. ◆ 6.7.6 POWER SUPPLY CORD The power supply cord must comply with all applicable codes, standards and regulations. It must be large enough to handle the full amperage to which it will be subjected. (See page 33 for illustration.) Generac® Power Systems, Inc. 31 Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators ◆ 6.7.7 GROUND FAULT CIRCUIT ◆ 6.8.3 BATTERY CABLE CONNECTIONS INTERRUPTERS The National Electrical Code (NFPA 70, article 551) requires that you install ground fault circuit interrupters (GFCIs) on all external and some internal electrical receptacles. Contact your manufacturer or dealer for recommendations. 6.8 BATTERY INSTALLATION ◆ 6.8.1 RECOMMENDED BATTERY Install a battery that meets the following requirements: • The battery must be a 12-volt, automotive type storage battery. • For prevailing ambient temperatures above 32° F (0° C), use a battery rated 70 amp-hours and capable of delivering 400 cold-cranking amperes. • For prevailing ambient temperatures below 32° F (0° C), use a battery rated 95 amp-hours and capable of delivering 400 cold-cranking amperes. NOTE: If the battery is to be used to power other vehicle accessories, as well as start the generator, you may need a battery with a larger capacity. 1. Connect the battery cable from the battery post or terminal indicated by a POSITIVE, POS or (+) to the lug on the starter contactor (Figure 6.21). NOTE: Check to be sure the battery cable boot for the starter cable has been installed. 2. Connect the battery cable from the battery post indicated by a NEGATIVE, NEG or (-) to the frame ground connection (Figure 6.21). 3. Connect cables so the connectors are clean and tight. Figure 6.21 – Connecting Battery Cables Positive Cable — + Battery Negative Cable Chassis Ground ◆ 6.8.2 BATTERY CABLES Using battery cables that are too long or too small in diameter may cause a drop in voltage, which causes starting problems. For the best cold weather starting, the voltage drop between battery terminals and the generator connection point should not exceed 0.12 volts per 100 amperes of cranking current. PRIMEPACT generators are rated at about 100 DC amperes of cranking current. Select battery cables based on (a) cable length and (b) prevailing ambient temperatures. Generally, the longer the cable and the colder the weather, the larger the cable size must be, as shown in the chart. CABLE LENGTH in Feet (meters) CABLE SIZE 0 to 10 (0 to 3) 2* 11 to 15 (3.4 to 4.5) 0 16 to 20 (4.5 to 6) 000 *For warm weather, use No. 2 cable up to 20 feet. 32 Generac® Power Systems, Inc. ◆ 6.8.4 BATTERY COMPARTMENT Install the generator battery in its own, vented compartment. Place the battery compartment away from any source of heat, sparks or flame. Provide ventilation openings in the battery compartment. The minimum size of openings should be 2 square inches at the top of the compartment. Mount the battery on a strong, rigid supporting structure, where leaks and spills of battery fluid will not cause damage. Section 6 – Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Figure 6.18 — Transfer Switch Isolation Method QUIETPACT 55G POWERED BY GUARDIAN 760cc OHVI V-TWIN INDUSTRIAL Figure 6.19 — Installation With Isolation Receptacle QUIETPACT 55G POWERED BY GUARDIAN 760cc OHVI V-TWIN INDUSTRIAL Generac® Power Systems, Inc. 33 Section 7 – Post Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 6.9 OPTIONAL ACCESSORIES A plug-in receptacle (Figure 6.22) is provided on the generator set, above the muffler enclosure. Use this receptacle to connect an optional remote-mounted start/stop panel to the generator. Installation of such a panel will permit you to start and stop the generator engine from any convenient location inside the vehicle. Figure 6.22 – Remote Panel Plug-in Receptacle 7.2 BEFORE INITIAL START-UP Before starting, complete the following: 1. Check the engine crankcase oil level and, if necessary, fill to the dipstick “FULL” mark (crosshatched area) with the recommended oil. Do not fill above the FULL mark. 2. Check the fuel supply. Gas fuel lines must have been properly purged and leak tested in accordance with applicable fuel codes. All fuel shutoff valves in the fuel supply lines must be open. DANGER ! 6 14A 14A 18 18 17 17 15 5 4 15 14 3 2 14 0 1 0 WIRE COLOR 0 14 15 17 18 14A WHITE RED ORANGE YELLOW BROWN BLUE LENGTH (mm) 12.0 (305) 12.0 (305) 12.0 (305) 12.0 (305) 12.0 (305) 12.0 (305) FUNCTION GROUND ENGINE RUN SIGNAL 12 VDC START STOP PRIME P/N: 0D9099-B ◆ 6.9.1 REMOTE PANEL MODELS The remote panels mount a rocker type start/stop switch, a “Generator Run” advisory lamp and an hourmeter. The hourmeter should be used in conjunction with the maintenance operations found in Part I of this manual. • Model 004057 includes the remote panel and a 10 foot long, 4 wire harness. • Model 004184 includes the remote panel and a 30 foot long, 4 wire harness. 7.1 POST INSTALLATION TESTS The air-cooled generator set was factory tested and adjusted. You should not be required to adjust the unit any further except under special circumstances. ! INITIAL START When you are absolutely certain that the unit has been properly installed and prepared for use, start the engine as follows: 12.00" WIRE No. 7.3 If a liquid propane (LP) gas fuel system has been installed, it must be properly tested for leaks before operating the system in compliance with ANSI A119.2/NFPA 501C. No leakage is permitted. You must be sure no gasoline fuel vapors enter the vehicle interior. Do not make any unnecessary adjustments. Factory settings are correct for most applications. When making adjustments, however, be careful to avoid overspeeding the engine. 34 Generac® Power Systems, Inc. 1. Turn off all electrical loads. Do this by setting the generator’s main circuit breakers to their “OFF” (or open) position. 2. Refer to Part I, Section 2.5, “Starting the Generator” (Page 8), for cranking and starting instructions. The engine may require more cranking for initial starting since the fuel lines have to be primed (use of the primer switch will shorten this time). 3. Let the engine warm up for about five minutes to allow internal temperatures to stabilize. 4. Carefully inspect the engine/generator for fuel, oil and exhaust system leaks. Before proceeding to the next step, correct any leakage immediately. 5. When all tests and adjustments at no-load are completed, apply electrical loads and check for proper operation under load. See Section 7.4. Run the unit at least 30 minutes with loads applied. 6. Turn off all electrical loads by setting the generator’s main circuit breakers to their “OFF” (or open) position. 7. Let the unit run at no-load for a few minutes to stabilize internal engine/-generator temperatures. Then, shut down the engine. NOTE: The generator set was thoroughly tested and adjusted at the factory before shipping. No additional adjustment should be necessary. Only qualified service technicians who have been trained should perform adjustments outlined in this manual. Section 7 – Post Installation QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 7.4 TESTING UNDER LOAD ◆ OPTIONAL LP GAS FUEL SYSTEM Apply electrical loads equal to about 75 to 100 percent of the unit's rated wattage/amperage capacity. ❑ Fuel system is properly installed and checked for leaks. Let the unit run at least 30 minutes with load applied. During this part of the test, check that the unit is not running excessively hot and that adequate cooling airflow is available. You must not allow the unit to overheat during prolonged operation. ❑ Pressure at regulator inlet is correct. NOTE: The generator engine is equipped with a high temperature switch. The switch has normally open (N.O.) contacts. When the engine temperature is too high, switch contacts close, and the engine shuts down automatically. GENERAC RECOMMENDS THAT YOU TEST THE GENERATOR FOR ADEQUATE COOLING. 7.5 INSTALLATION CHECKLIST ◆ LOCATION AND SUPPORT ❑ Rated flow of primary regulator is correct. ❑ All parts are properly installed. ❑ Fuel system is properly tested/adjusted. ◆ EXHAUST SYSTEM ❑ Exhaust system complies with all applicable codes. ❑ Exhaust system is properly and safely installed. ◆ ELECTRICAL CONNECTIONS ❑ Connections comply with local code requirements and all National Electrical Codes. ❑ Junction box is properly installed. ❑ Wiring meets all standards. ❑ Generator is properly located. ❑ All connections are correct. ❑ Generator is properly supported. ❑ Conduit is properly installed and sealed. ❑ Generator is properly restrained. ❑ Generator is properly bonded to the vehicle. ◆ GENERATOR COMPARTMENT ◆ BATTERY INSTALLATION ❑ Compartment construction is proper. ❑ Recommended battery is installed. ❑ Holes/Openings are vapor-sealed. ❑ Recommended cables are installed. ❑ Compartment size is correct. ❑ Cables are clean and tight. ❑ Compartment is vapor-sealed. ❑ Cables are connected properly. ❑ Sound insulation is correct. ❑ Proper ventilation is provided. ❑ Floor cutouts are properly completed. ❑ Terminals are coated with anti-corrosion grease, and terminal covers are positioned. ◆ COOLING AND VENTILATING AIR ❑ Airflow is adequate. ❑ Air inlet opening is correct. ❑ Compensate for restrictions. ❑ Check that installation has been tested. ◆ GASOLINE FUEL SYSTEM ❑ Fuel tank complies with all applicable codes. ❑ Fuel system is properly installed and checked for leaks. ◆ OPTIONAL ACCESSORIES ❑ Check that remote start/stop panels (if used) are installed properly. ❑ Check that hourmeter kit (if used) is installed properly. ❑ Check that any other options and accessories (if used) are installed properly. ◆ POST INSTALLATION TESTS ❑ Check that all tests are completed properly. DATE OF INSTALLATION ____________________________________________________ NAME OF INSTALLER ______________________________________________________ SIGNATURE OF INSTALLER ________________________________________________ Generac® Power Systems, Inc. 35 Section 8 – Troubleshooting QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 8.1 TROUBLESHOOTING GUIDE PROBLEM Engine won’t crank. CAUSE 1. 2. CORRECTION 3. 4. 5. 6. 7. 7.5 amp fuse blown. Loose, or corroded or defective battery cable(s). Battery is discharged or defective. Defective Start/Stop switch. Defective starter contactor. Defective starter motor. Defective Engine Control Board 3. 4. 5. 6. 7. Replace blown fuse. Tighten, clean or replace, as necessary. Recharge or replace battery. Replace switch. Replace starter contactor. Replace starter motor. Contact an authorized service dealer. Engine cranks, won't start. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Out of fuel. Fuel shutoff valve is closed. Fuel pump not operating. Automatic choke not operating properly. Engine is flooded. Fuel filter is clogged. Engine spark plugs defective. Bad ignition magneto on engine. Bad carburetor. Dirty air cleaner. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Refill fuel tank. Open fuel shutoff valve(s). Repair or replace pump. Repair, replace or adjust. Wait 5-10 minutes; try again. Replace filter if clogged. Clean, regap or replace as needed. Replace if defective. Adjust, repair or replace. Clean or replace as needed. Engine starts hard, runs rough. 1. 2. 3. 4. Dirty engine air cleaner. Automatic choke is sticking. Defective spark plugs. Defective ignition magneto. 1. 2. 3. 4. Clean or replace as needed. Free choke linkage as needed. Clean, regap or replace. Replace it if defective. Engine starts, then shuts down. 1. 2. 3. 4. 5. Engine oil level is low. Bad low oil pressure switch. Defective high temp switch. Water in fuel. Defective remote harness. 1. 2. 3. 4. 5. Add oil as needed. Replace, if bad. Replace, if bad. Drain fuel tank and refill. Disconnect remote harness. Contact authorised service facility. No AC output voltage. 1. 2. Main breaker(s) open. Transfer switch (if so equipped) is set to wrong position. Failure in vehicle electrical system. Generator component failure. 1. 2. Close main breaker(s). Reset transfer switch. 3. 4. See vehicle manual. Contact an authorized service facility. 3. 4. 36 Generac® Power Systems, Inc. 1. 2. Section 9 – Notes QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Generac® Power Systems, Inc. 37 Section 10 — Electrical Data QUIETPACT 55, 65, and 75 Recreational Vehicle Generators V-Twin – Drawing No. 0E1057-B BATTERY RED BLK SC RED 13 16 13 0 SM 16 0 SC SCR 14 F1 0 FS 15 14A 0 FP 0 14 CH SW2 16 PCB 15 56 J2 90 14 15 15 0 SCR J3 J1-4 18A J1-5 18A J1-6 17 J1-7 17 CS 0 SP2 0B J1-8 J1-9 4 14A 85 85 HTO 0 85 LOP 0 REMOTE PANEL 66 18 J1-15 4 18 17 0I 1 14 15 1 55 R1 CB3 - CIRCUIT BREAKER, 2.5A (QP55 MODEL) CIRCUIT BREAKER, 3.0A (QP65 & QP75 MODELS) CH - CHOKE HEATER (GASOLINE MODELS ONLY) 0N F1 - FUSE, 7.5A FP - FUEL PUMP-OR-LPG SHUT OFF VALVE FS - FUEL SOLENOID GT - TERMINAL, GROUND HM - METER, HOUR (OPTIONAL) HTO - SWITCH, HIGH TEMP. OIL (CLOSES ON HIGH TEMP.) IM1 - IGNITION MAGNETO - #1 CYL. IM2 - IGNITION MAGNETO - #2 CYL. L1 - LIGHT, RUN (OPTIONAL) LOP - SWITCH, LOW OIL PRESSURE (CLOSES ON LOW PRESSURE) L1 4 33 0N 44 22S 11S FUEL PRIME 11P ELECTRONIC VOLTAGE REGULATOR 0K CB1 RED CB2 2A SW1 - SWITCH, START/STOP SW2 - SWITCH FUEL PRIMER SP1 - SPARK PLUG #1 CYL. SP2 - SPARK PLUG #2 CYL. TC - TERMINAL, CONN. 4-TAB - CONNECTOR BLACK CB3 0N 4 2 6 T1 T3 DPE WINDING 0F GREEN T2 4 FIELD 120V 20A - QP55 120V 30A - QP65 120V 35A - QP75 120V 30A - QP55 & QP65 120V 35A - QP75 NEUTRAL CONNECTION BY CUSTOMER 38 Generac® Power Systems, Inc. HM 22P R1 - RESISTOR, 1 OHM 25W SC - STARTER CONTACTOR SCR - STARTER CONTACTOR RELAY WHITE 18 14 17 0 66 77 BCR - BATTERY CHARGE RECTIFIER CB1 - CIRCUIT BREAKER, 30A (QP55 & QP65 MODELS) CIRCUIT BREAKER, 35A (QP75 MODEL) CB2 - CIRCUIT BREAKER, 20A (QP55 MODEL) CIRCUIT BREAKER, 30A (QP65 MODEL) RED 15 LEGEND BLUE 14A 66 BROWN 3 4 14A BLACK RED REMOTE PANEL (OPTIONAL) Section 10 — Electrical Data QUIETPACT 55, 65, and 75 Recreational Vehicle Generators V-Twin – Drawing No. 0E1057-B SUPPLIED BY CUSTOMER 12V BATTERY SM SUPPLIED BY CUSTOMER 13 SC 16 11S 6 2A 16 16 ELECTRONIC VOLTAGE REGULATOR 22S 13 13 STATOR 2A 0 16 56 0 15 J3 15 14 56 0 90 22S 2A 18A 6 11S 17 2 17 17 4 77 66 4 66 55 0 14 2A RED 4 18 FIELD 0F 15 13 77 CB3 22P 2 66 0K 85 0 0 18 0F GT 0 0F 0 0I 0 0 0I 14 14 1 0 33 14A 15 18 15 REMOTE PANEL CONNECTOR CB1 11P 0B FP T2 T2 F1 RED FS SW1 SW2 15 GT TC 14 CONN. 2 PIN# 14A 4 18 17 2 3 14 14 14 14 2 17 14 90 3 0N 33 17 15 66 18 R1 11P 2 18A 55 44 2A CH 4 2 0 0 CLOSEST TO BEARING 44 16 J1-15 33 11P 90 RED 18 13 11P 0 15 CB2 BLACK 18 18 14A 18A 85 14A 15 15 85 LOP WHITE HTO T3 0 T1 0 GREEN CUSTOMER AC CONNECTION NEUTRAL CONNECTION BY CUSTOMER 18A 18A BLACK RED WHITE SP1 IM2 Generac® Power Systems, Inc. 39 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Base & Pulley – Drawing No. 0E1323-A 4 4 2 3 3 6 8 3 9 7 1 "B 10 11 5 8 12 3 2 13 3 2 4 1 3 15 2 23 22 21 19 18 20 25 26 27 45 A " 14 16 17 28 59 30 60 49 48 44 3 37 36 6 61 33 32 26 52 50 51 47 53 43 42 41 54 55 56 40 10 50 52 TO CARB. 39 "B 31 46 57 34 53 58 "A " 35 40 Generac® Power Systems, Inc. Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Base & Pulley – Drawing No. 0E1323-A ITEM PART NO. QTY. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0E0196 022129 022145 022259 0C7758 0C3168 0C2417 077603 0E0588 029451 0D8912 0E0571 0D8911 043107 0D9021 096289 0D8940 070006 070008 040976 056893 023897 0E1078 0C4138 043116 1 12 15 6 4 1 1 2 1 1.5 FT. 1 2 1 7 1 1 1 4 4 4 6 6 2 2 3 26 022097 022097 4 1 27 022473 3 28 29 0C1751 0C1753B 1 1 073106B 1 075224A 1 075224B 1 30 FRAME, 760 ENGINE WASHER LOCK M8-5/16 WASHER FLAT 5/16-M8 ZINC NUT HEX 5/16-18 STEEL VIB MNT 1.5 X 1.38 X 5/16-18 WASHER LOCK SPECIAL 5/16 EARTH STRAP SCREW HHC 5/16-18 X 3.5 SPC SPACER, SAFETY BOLT .375 I.D. TAPE ELEC UL FOAM 1/8 X ½ DUCT, AIR OUT GASKET,AIR OUT DUCT BRACKET, MUFFLER SUPPORT SCREW HHC M8-1.25 X 25 G8.8 MUFFLER, GTV760 RV CLAMP, EXHAUST 1.25" MANIFOLD, EXHAUST WASHER LOCK M8 SS WASHER FLAT M8 SS SCREW SHC M8-1.25 X 20 G12.9 SCREW CRIMPTITE 10-24 X ½ WASHER FLAT #10 ZINC GASKET, EXH BASE, GTV760 RV GASKET,EXHAUST PORT SCREW HHC M6-1.0 X 12 G8.8 (5.5 KW ONLY) WASHER LOCK M6-1/4 (5.5 KW ONLY) WASHER LOCK M6-1/4 (6.5 & 7.5 KW ONLY) WASHER FLAT 1/4-M6 ZINC (5.5 KW ONLY) FAN NYLON 7" DIA (5.5 KW ONLY) PULLEY, ALTERNATOR 2200 RPM (5.5 KW ONLY) PULLEY, ALTERNATOR 2500 RPM (6.5 & 7.5 KW ONLY) PULLEY, ENGINE 2100 RPM (5.5 KW ONLY) PULLEY, ENGINE 2500 RPM (6.5 & 7.5 KW ONLY) ITEM PART NO. QTY. DESCRIPTION 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 51 52 53 0E0586 0D7176 0E1334 0D8824 081105 073118 046526 022131 0C2824 0E1077 042633 022237 049451 0C1441 0C1112 023484E 0E1534 0D7530 0D9723 0D4511 0D8981 0D8981 0D8451 087680 0D3700 1 4 1 1 2 1 1 1 7 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 3 54 0D3700 087769 1 1 55 0E0570 1 56 0D9919 1 57 0E1330 1 58 59 60 61 0E1534A 0A1658 0D5133 0D5133A 045764 1 1 1 1 1 47 48 49 50 GASKET, BOTTOM AIR OUT QPRV WASHER SELF LOCKING 1"DIA 12GA SCREEN, BOTTOM AIR OUT TRAY, V-TWIN RV NUT FLG 5/16-18 LOCK SCREW HHC 3/8-24 X 2-1/4 G8 WASHER LOCK M10 WASHER FLAT 3/8-M10 ZINC SCREW TAP-R #10-32 X 9/1 BLOWER HOUSING GTV760 RV SCREW HHC 3/8-24 X 1 G5 WASHER LOCK 3/8 WASHER FLAT .406ID X 1.62OD SET,BLOWER HOUSING GASKET BELT,V-RIB 4LX42.5" BUSHING SNAP (GASOLINE ONLY) PLUG PLASTIC 0.687" (LP ONLY) STUD, M6-1.0 OFFSET ELEMENT AIR FILTER PRECLEANER,AIR GTH990 GASOLINE FILTER GASKET RV (GASOLINE ONLY) FILTER GASKET RV (LP ONLY) WASHER FLAT .281"ID X 1.25"OD NUT WING M6-1.0 NUT FLANGE M6-1.0 NYLOK (GASOLINE ONLY) NUT FLANGE M6-1.0 NYLOK (LP ONLY) FILTER FUEL 1/8P-5/16H (GASOLINE ONLY) ASSEMBLY,NON SHTOFF FUEL PUMP (GASOLINE ONLY) ASSEMBLY, RV V-TWIN FUEL LINE (GASOLINE ONLY) GROMMET, 38.1 DIA. CROSS SLIT (GASOLINE ONLY) PLUG PLASTIC 1.50" (LP ONLY) WASHER LOCK SPECIAL 1/4" SCREEN, SPARK ARRESTOR RETAINER, SPARK ARREST SCREEN SCREW HHTT M4-0.7 X 8 BP Generac® Power Systems, Inc. 41 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Enclosure – Drawing No. 0E1011-B 30 31 32 GROUND TO CONT. PANEL GROUND TO ENGINE 29 28 27 26 33 3 34 1 TARTER 25 35 36 30 31 30 48 37 24 2 42 9 43 44 23 4 38 46 VIEW "A" 3 6 48 38 47 7 5 5 5 40 VIEW "A" 16 17 14 13 15 5 8 5 40 6 10 6 12 2 11 41 22 5 21 18 2 5 19 9 42 Generac® Power Systems, Inc. 20 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Enclosure – Drawing No. 0E1011-B ITEM PART NO. QTY. DESCRIPTION 1 2 3 4 5 0D8827 0A7215 029451 0D8825 0D3700 0D3700 090388 0D8979 0D8960 023484D 0E0594 064113 0E0575 0D8980 0E1376 0E1377 0D8628 0D8910 0D8826 0D9162 0C5644 0D8828 0E0585 0E1486 0E1774 0D9099 074908 022473 022097 022507 0742600149 0C7968 022237 0C7423 0742600151 0A4456 0D8502 0E0593 0742600148 022129 022129 022259 045756 0A2115 029451A 0E1534A 0A5606 0E1528 0A1495 042907 022145 022145 0D8979A 1 22 11.5 FT. 1 14 17 8 1 1 1 1 1 1 1 1 1 3.5 1 1 1 2 1 1 1 1 1 4 1 1 1 1 4 2 1 1 1 1 1 1 2 4 2 8 1 6.5 FT. 1 1 1 2 2 1 3 1 PANEL, ENCLOSURE ROOF SCREW SW 1/4-20X5/8 N WA JS500 TAPE ELEC UL FOAM 1/8 X 1/2" PANEL, SIDE AND BACK ENCLOSURE NUT FLANGE M6-1.0 NYLOK (GASOLINE ONLY) NUT FLANGE M6-1.0 NYLOK (LP ONLY) SCREW HHTT M6-1.0 X 12 YC PANEL, AIR IN DUCT BASE PANEL, CUSTOMER CONNECTION BUSHING SNAP SB-875-11 COVER, RV AIR CLEANER BOX STUD WINGNUT M6-1.0 X 20MM NY FOAM SEALING STRIP 1" X 12FT PANEL, AIR IN DUCT BACK BAFFLE, V-TWIN RV SHORT BAFFLE, V-TWIN RV LONG FOAM, AIR OUT COMPARTMENT PANEL, MUFFLER SHIELD PANEL, ENCLOSURE SIDE PANEL, FRONT & SIDE ENCLOSURE SLIDE LATCH,FLUSH PANEL, ENCLOSURE DOOR FOAM PANEL, DOOR 1/2"THK QP RV HARNESS, AC OUTPUT (5.5, 6.5, & 7.5 KW ONLY) HARNESS, AC OUTPUT (5.0 & 7.0 KW-50 Hz ONLY) CUST. CONN. 4KW RV REMOTE SCREW HHTT M5-0.8 X 10 BP WASHER FLAT 1/4-M6 ZINC WASHER LOCK M6-1/4 SCREW HHC 1/4-20 X 1/2 G5 WIRE ASM. BATT. (NEG.) QP RV NUT HEX JAM 3/8-16 BRASS WASHER LOCK 3/8 STUD 3/8-16 X 2-1/4 BRASS GND WIRE C/PNL TO STUD V-T RV WASHER LOCK SPECIAL 3/8 NEUTRAL CONNETCTOR UL STUD, 1/4-20 TO 5/16-18 WIRE ASM BATT. (POS.) QP RV WASHER LOCK M8-5/16 (GASOLINE ONLY) WASHER LOCK M8-5/16 (LP ONLY) NUT HEX 5/16-18 STEEL SCREW HHTT M6-1.0 X 10 YC WASHER NYLON .250 TAPE, 1/2" X 1/16" CLOSED CELL PLUG PLASTIC 1.50" (GASOLINE ONLY) ELBOW 90DEG 3/8X3/4 (LP ONLY) BRACKET, LP REGULATOR MOUNTING (LP ONLY) SCREW HHTT M4-0.7 X 10 BP (LP ONLY) SCREW HHC M8-1.25 X 16 G8.8 (LP ONLY) WASHER FLAT 5/16-M8 ZINC (GASOLINE ONLY) WASHER FLAT 5/16-M8 ZINC (LP ONLY) PANEL, AIR IN DUCT 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Generac® Power Systems, Inc. 43 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Sheet Metal – Drawing No. 0E1012-B 1 96 2 113 5 3 94 4 66 92 2 102 "A" A 91 1 98 99 100 0 8 9 6 7 97 5 101 87 "B" 11 "C" 85 15 14 TO LP REGULATOR 106 83 107 106 114 115 116 82 12 84 81 "A" 1 80 74 75 78 8 7 70 7 79 69 73 77 67 66 63 17 18 60 65 64 105 103 "D" 1 66 104 5 58 112 111 110 109 55 62 54 53 "C" 50 35 39 18 "B" 20 29 36 28 32 4 31 30 22 44 Generac Power Systems, Inc. 40 27 21 ® 33 57 56 39 4 46 45 5 23 26 37 38 44 42 52 48 43 49 41 108 6 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Sheet Metal – Drawing No. 0E1012-B ITEM PART NO. QTY. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 045756 0D1131 0C3022G 0C9763 0D9782 0C3034 0C3033 051754 0A5992 0C3032 0C3031 0C3725A 0C3016A 023484F 0D9679A 0D9708 0D9681A 056893 072347 0E0998 0D8384 043790A 0D3083 0E0361A 0E0393 0C2824 15 1 1 4 1 1 1 2 2 1 1 1 1 1 1 1 1 13 2 1 1 1 1 1 1 2 27 28 29 30 31 32 33 34 35 36 0C2824 065852 075246 0A4456 0A2311 070185 0A8584 0A5360 043182 0C1085 0E1497 1 1 4 1 2 1 1 1 2 2 1 37 38 075281 0D9399 0D9513 1 1 1 0E1498 1 39 40 41 0D1366 0D9395 077075 2 1 1 42 43 44 45 46 47 48 0A7094 0D8590 0D8591 045770 049226 051713 0D9402 2 1 1 1 1 1 1 49 50 51 52 53 54 55 56 077091 082025 0E1247 055173 022129 022145 0D9403 0E1246 1 1 1 2 2 2 1 1 DESCRIPTION SCREW HHTT M6-1.0 X 10 YC GUARD,FAN 12KW HSB HOUSING, BLOWER V-TWIN RV NUT,GROMMET 1/4 PLUG HOSE, BREATHER NUT HEX M24-2.0 G8 YEL CHR WASHER,BELLEVILLE 25MM BOLT SCREW HHC M8-1.25 X 12 G8.8 WASHER SHAKEPROOF INT M8 SS PLATE, FAN GV-990 FAN NYLON GV-990 FLYWHEEL ASSY GT-990 PLATE,BACKING GT990 W/OIL COOL BUSHING SNAP SB-1000-12 WRAP, CRANKCASE GTV760 RV SPCC GT760 VERTICAL SHAFT RV ENGINE WRAP, CYL 1 GTV760 RV SPCC SCREW CRIMPTITE 10-24 X ½ SPARK PLUG CLAMP VINYL 9.5 O.D. TUBE TUBE, OIL DRAIN & CHECK BARBED EL 90 3/8NPT X 3/8 VS ASSEMBLY, OIL DRAIN HOSE OIL DRAIN / DIPSTICK TUBE VTW ASSEMBLY, CAP & DIP STICK SCREW TAP-R #10-32 X 9/16 (GASOLINE ONLY) SCREW TAP-R #10-32 X 9/16 (LP ONLY) SPRING CLIP HOLDER .37-.62 SCREW HHTT 3/8-16 X 1-1/4 CZ WASHER LOCK SPECIAL 3/8 SCREW SWAGE 1/4-20 X 1 Z/YC FILTER, OIL D 69X64 LG SWITCH OIL PRESSURE HOBBS SUPPORT OIL FLTR,FLARE WASHER LOCK M3 SCREW PPHM M3-0.5 X 8 SWITCH, OIL HIGH TEMP (GASOLINE ONLY) SWITCH, OIL HIGH TEMP (LP ONLY) ASSEMBLY, GOVERNOR LEVER SPRING, GOV.(5.5 KW & 5.0 KW-50HZ ONLY) SPRING, GOV.(6.5/7.5 KW & 7.0 KW-50HZ ONLY) BUSHING, GOVERNOR ROD ROD, GOVERNOR BOOT CHOKE SOLENOID (GASOLINE ONLY) RHMS 4-40 X 1/4 SEMS (GASOLINE ONLY) ASSY, BI-METAL/HEATER (GASOLINE ONLY) SOLENOID, CHOKE (GASOLINE ONLY) SCREW HHC M5-0.8 X 10 G8.8 WASHER LOCK M5 WASHER FLAT M5 LINKAGE, CHOKE SOLENOID/BELLCRNK (GASOLINE ONLY) COTTER PIN (GASOLINE ONLY) NUT LOCK HEX M5-0.8 SS NYL INS ASSEMBLY, GOV. ADJUSTMENT SCREW HHC M8-1.25 X 20 G10.9 WASHER LOCK M8-5/16 WASHER FLAT 5/16-M8 ZINC LINKAGE CHOKE BELLCRANK/CARB ASSEMBLY, CHOKE BRACKET (GASOLINE ONLY) ITEM PART NO. QTY. 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 0D9400 0A7095 0D9404 0D9801A 0C3018A 0D9680A 0D1143A 0C3053 085011 0D9852 022097 092079 0C1546 0C1547 082774 0A5358 0D9312 0D9314 0C1557 0A9028 0D9682A 0D9270 048031A 0D9269 0E0142 078643B 0D9219 0E0573 0D8807 0E1217 0E0572 0C3043 0D8836 049821 070008 070006 035461A 040173 0C9806 0C3026 0D9683A 0C9764 036933 0E0246 0D9394 022152 022158 043116 049811 047411 066849B 057822 074994 075476 1 2 1 1 1 1 1 1 1 2 8 4 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 2 1 4 4 4 2 4 2 1 1 4 1 1 1 1 1 2 4 2 2 2 2.25 FT. 1 109 082121A 1 110 111 112 113 114 115 116 038150 022264 051715 0D6029 055934D 022473 090388 1 1 1 2 1 1 1 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 DESCRIPTION BRACKET, CHOKE (LP ONLY) RHMS 4-40 X 5/16SEMS SPRING, CHOKE RETURN WRAP, VALLEY UPPER SPCC WRAPPER,UPR #1 W/ M8 WELD NUT WRAP, VALLEY GTV760 RV SPCC WRAPPER,UPR #2 W/ M8 WELD NUT ASSY GROUND WIRE GV990 INSULATOR ASM IGN ASSY,IGNITION COIL GT760 RV WASHER LOCK M6-1/4 SCREW HHTT M6-1.0 X 25 BP O-RING 59.92 X 66.98 X 3.53MM O-RING 21.89 X 27.13 X 2.62MM KEY, WOODRFF 4 X 19D ADPTR OIL PAD, FLARE TUBE, ENGINE OIL RETURN TUBE, ENGINE OIL OUT O-RING 20.35 X 23.91 X 1.78MM BOLT, OIL ADAPTOR WRAP, CYL 2 GTV760 RV SPCC INTAKE TUBE 1.25" X 20 GA HOSE CLMP-BAND 1 5/8 BOOT, INTAKE AIRBOX BOOT, CARB ADAPTOR BOLT,CARB MOUNT M6 X 1.0 -85LG ADAPTER, AIR INTAKE CARB GASKET,CARB TO ADAPTOR CARBURETOR, GT-760 (GASOLINE ONLY) CARBURETOR, GT-760 (LP ONLY) GASKET,CARB TO INTAKE MANIFOLD GASKET INTAKE PORT GT990 MANIFOLD, INTAKE 760 RV SCREW SHC M8-1.25 X 30 G12.9 WASHER FLAT M8 SS WASHER LOCK M8 SS BARBED STR 1/4NPT X 3/8 W/VS CLAMP HOSE #5.5 .62 - .62 HOSE,3/8"IDX6"L 300F COOLER, OIL GV-990 DUCT, OIL CLR GTV760 RV SPCC PLASTITE,1/4-15 X ¾ SCREW PPHM #10-32 X 3/8 SCREW HHTT #4-40 X ¼ PLATE, THROTTLE WASHER LOCK #10 NUT HEX #10-32 STEEL SCREW HHC M6-1.0 X 12 G8.8 WASHER FLAT M6 SCREW HHC M6-1.0 X 16 G8.8 SCREW HHTT M5-0.8 X 8 BP CLAMP HOSE #8 .53 - 1.00 (LP ONLY) HOSE 1\2 ID (LP ONLY) SCREW PPHM M4-0.7 X 16 (GASOLINE ONLY) CLIP-J VINYL COAT .375 ID (GASOLINE ONLY) WASHER FLAT #8 (GASOLINE ONLY) WASHER LOCK #8 (GASOLINE ONLY) NUT HEX M4-0.7 G8 YC (GASOLINE ONLY) SCREW HHTT M6-1.0 X 16 YC CLAMP VINYL 1.06 X .406 (LP ONLY) WASHER FLAT 1/4-M6 (LP ONLY) SCREW HHTT M6-1.0 X 12 (LP ONLY) Generac® Power Systems, Inc. 45 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Control Panel – Drawing No. 0E1013-A 3 6 7 8 9 2 4 1 5 9 10 13 11 46 12 2 39 40 37 36 35 47 45 5 25 14 4 26 27 7 7 44 4 49 8 43 50 8 51 52 7 42 15 41 28,2 55 16 39 17 40 56 53 5 30 31 18 19 20 60 32 33 37 36 34 35 54 59 39 61 62 63 65 7 8 64 67 21 22 23 24 5 46 Generac® Power Systems, Inc. 66 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators Control Panel – Drawing No. 0E1013-A ITEM PART NO. QTY. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 0C2375 022145 029459 075215 052858 047411 022097 022473 080925 0D9921 066849 066386 0C9674 0E0363H 0E0364H 0E0362H 073159 077005H 077004H 073163H 031971 077006 0C9675 0A5351 073146 0C1878 075242 075237 090145 2 2 2 2 6 7 13 10 8 4 2 1 1 1 1 1 1 1 1 1 1 4 1 1 2 2 4 4 1 0E1529 090144 090145 0E1529 025105 0A9611 032300 092113 087798 055440 0D9377 1 1 1 1 4 1 1 1 1 2 1 SCREW HHC M8-1.25 X 90 G8.8 WASHER FLAT 5/16-M8 ZINC TENSION SPRING WASHER, SPRING CENTER NUT LOCK FL M8-1.25 SCREW HHC M6-1.0 X 16 G8.8 WASHER LOCK M6-1/4 WASHER FLAT 1/4-M6 ZINC WASHER NYLON .404 STANDOFF, 1/2" HEX SCREW HHTT M5-0.8 X 16 ASSY, BRUSH HOLDER BEARING CARRIER, UP STATOR ASSEMBLY (5.5 KW ONLY) STATOR ASSEMBLY (6.5 KW ONLY) STATOR ASSEMBLY (7.5 KW ONLY) BEARING BALL ROTOR ASSEMBLY (5.5 KW ONLY) ROTOR ASSEMBLY (6.5 KW ONLY) ROTOR ASSEMBLY (7.5 KW ONLY) BEARING STUD,RV STATOR D/C BEARING CARRIER, LOW NYLON SLIDE SLIDE, NYLON SUPPORT, SLIDE SPRING, GEN. MOUNT WASHER, SPRING CENTER CIRCUIT BREAKER 30 X 1 (5.5 & 6.5 KW ONLY) CIRCUIT BREAKER 35 X 1 (7.5 KW ONLY) CIRCUIT BREAKER 20 X 1 (5.5 KW ONLY) CIRCUIT BREAKER 30 X 1 (6.5 KW ONLY) CIRCUIT BREAKER 35 X 1 (7.5 KW ONLY) SCREW RHM 6-32 X 1/4 SIMS FUSE 7.5 AMP HOLDER FUSE SWITCH SPDT ON-MOM-ON SWITCH 6A SPDT SCREW HHC M5-0.8 X 25 G8.8 PANEL, TOP CONTROL ITEM PART NO. QTY. DESCRIPTION 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 054502 031879 043182 051714 092234 049226 051716 023484R 0D3700 0D9378 052619 075476 065795 0C2174 092120 049721 0A1658 074260-146 049813 023484D 074260-151 084867 043181 075210A 022264 051715 0C7605 083049 089047 075234 0A2053 058000K 0D8941 029451A 0E0583 1 4 4 4 1 5 3 2 1 1 1 2 1 1 4 2 2 1 4 1 1 1 2 1 2 2 2 1 2 1 1 2 1 2.3 FT. 1 0E1812 1 0E1375 1 CIRCUIT BREAKER 3 X 1 WASHER FLAT #4 ZINC WASHER LOCK M3 NUT HEX M3-0.5 G8 YEL CHR ASSY POTTED RV CNTL WASHER LOCK M5 NUT HEX M5-0.8 G8 YEL CHR BUSHING SNAP NUT FLANGE M6-1.0 NYLOK PANEL, BOTTOM CONTROL SCREW HHC M5-0.8 X 20 G8.8 SCREW PPHM M4-0.7 X 16 RECTIFIER-BATTERY CHARGE RELAY 12V 25A SPST NUT LOCK TRIC M6 X 1.0 Y/ZNC SCREW HHC M6-1.0 X 35 G8.8 BLK WASHER LOCK SPECIAL 1/4" WIRE ASM GRD STD CONN. NUT HEX M6 X 1.0 G8 YEL CHR BUSHING SNAP GROUND WIRE C/PNL TO STUD V-T RV RUBBER U-CHANNEL SCREW PHM M3-0.5 X 10MM BLOCK 1 POSITION WASHER LOCK #8-M4 NUT HEX M4-0.7 G8 YEL CHR SCREW HHC M5-0.8 X 60 G8.8 ASY POTTED REG W/FIN SPACER .25 X .43 X .55 ST/ZNC RESISTOR WW LUG 1R 5% 25W SCREW HHC M6-1.0 X 65 G8.8 NUT TRIC M5 X .8 COMPARTMENT, AIR BOX TAPE, 1/2" X 1/16" CLOSED CELL WIRE HARNESS, QP RV (GASOLINE ONLY)(NOT SHOWN) WIRE HARNESS, QP RV (LP ONLY) (NOT SHOWN) WIRE ASS'Y STARTER TO C/PNL (NOT SHOWN) Generac® Power Systems, Inc. 47 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 760 V-Twin Engine – Drawing No. 0E1014-B 3 4 2 5 62 63 1 6 64 7 8 22 9 59 61 60 58 11 19 7 18 12 56 17 54 53 44 2 51 50 49 48 16 14 15A 15B 15A 13 25 26 24 20 23 47 46 27 21 28 45 43 33 3 42 29 34 30 36 33 32 31 37 41 40 39 48 Generac® Power Systems, Inc. 38 35 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators 760 V-Twin Engine – Drawing No. 0E1014-B ITEM PART NO. QTY. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15A 15B 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 0C5730A 0C3008 090388 0C5372 0C3005 0C3003 0D8067A 0C2981C 071983 0C5848 021533 071980 0D4041 0C2983 0C2985A 0C2985B 0D4042 0A7811 0C2977 0C5943 0D4122A 0D3961 0C2978 093873 021374 0C2994 0C2997 0C2995 0C2996 0C3011 0C3009 0C3010 050873A 1 1 6 1 1 3 1 1 4 2 2 2 1 1 2 1 1 1 1 1 1 2 2 3 3 1 1 1 1 2 2 2 1 DESCRIPTION ASSEMBLY, CRANKCASE RV SEAL, 38 I.D. CRANKCASE SCREW, HHTT M6-1.0 X 12mm ASSEMBLY, BREATHER GASKET, BREATHER COVER SEPARATOR, OIL BREATHER ASSEMBLY, HEAD #1 COVER, ROCKER RETAINER, PISTON PIN 20 PISTON, HC SET, PISTON RING 90mm PIN , PISTON D20 ASSEMBLY, CAMSHAFT & GEAR SHAFT, GOVERNOR ROLLER BEARING, GOVERNOR PLATE ROLLER BEARING, GOVERNOR ASSEMBLY, GOVERNOR GEAR SPOOL, GOVERNOR MACHINED GASKET, CRANK CASE SEAL, OIL PASSAGE ASSEMBLY, CRANKSHAFT ASSEMBLY, CONNECTING ROD GASKET, HEAD WASHER, LOCK RIB M6 SCREW, SHC M6-1.0 X 30mm SCREEN, OIL PICKUP COVER, GEROTOR GEROTOR, INNER GEROTOR, OUTER COVER, OIL RELIEF SPRING, OIL RELIEF BALL, 1/2D OIL RELIEF 1/4" NPT PIPE PLUG ITEM PART NO. QTY. 33 34 35 36 37 38 39 40 0C2991 0D1667A 0C2988 0C2992 0C5732 0C2993 0C3007 0D9756 2 1 1 1 1 1 1 1 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 0C3006 0C8566 0C2982 093064 0C2979 086515 0D2274 0D3867 078672 0C5371 0D5326 0D5354 0D5313 0D6023 0D6024 0C2976 0D8067B 0C2229 086516 0D9853D 083897 0C3017 022129 061906 10 8 1 1 2 8 4 4 2 4 4 4 4 4 2 12 1 2 2 4 4 1 2 2 DESCRIPTION E-RING, GOVERNOR ARM ARM, GOVERNOR THRUST WASHER, GOVERNOR BUSHING, GOVERNOR LOWER ASSEMBLY, SUMP WITH SLEEVE SEAL, GOVERNOR SHAFT SEAL, 42 I.D. CRANKSHAFT CONNECTOR, 3/8NPT TO INVTD FLR 3/8OD SCREW, HHFC M10-1.5 X 55mm SCREW HHFC M6-1.0 X 20mm COVER, ROCKER WITH OIL FILL ASSEMBLY, OIL FILL CAP GASKET, VALVE COVER KEEPER, VALVE SPRING RETAINER, VALVE SPRING SPRING, VALVE SEAL, VALVE STEM D7 WASHER, VALVE SPRING NUT, JAM ROCKER ARM PIVOT, ROCKER ARM ROCKER ARM STUD, ROCKER ARM M8-1.0 x 57mm PLATE, PUSH ROD GUIDE SCREW HHFC M8-1.25 X 65mm ASSEMBLY, HEAD #2 VALVE, INTAKE VALVE, EXHAUST PUSHROD 147 TAPPET, SOLID STARTER, V-TWIN ENGINE WASHER LOCK M8 SCREW, HHC M8-1.25 X 85mm Generac® Power Systems, Inc. 49 Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators LP Regulator – Drawing No. 0E1530 2 3 5 4 6 7 8 1 11 10 9 12 16 13 17 14 18 19 15 21 22 20 23 24 25 26 27 50 Generac® Power Systems, Inc. Section 11 — Exploded Views and Parts Lists QUIETPACT 55, 65, and 75 Recreational Vehicle Generators LP Regulator – Drawing No. 0E1530 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 PART NO. 0D5694 075475 022264 043180 0C5765 0C6070 0C4680 0C4647 0C4643 0D3973 0C6606 026073 0D3308 070728 0C5764 0C4643A 0C6066 0C5968 0C5759 0C5761 0C6069 0C6731 0C6067 0C4706 0C6068 0C5762 045764 QTY. 1 4 4 4 1 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 8 DESCRIPTION CASTING, TWIN REGULATOR HOUSING SCREW PPHM M4-0.7 X 10 WASHER LOCK #8-M4 WASHER FLAT M4 SOLENOID, TWIN REGULATOR SPRING-SOLENOID PLUNGER PLUNGER LP REG. ASSY GASKET, SOLENOID INLET, TWIN REGULATOR NO HOLE PLUG, EXPANSION 16MM TWINREG BARBED STR 1/2 X 1/2NPT W/VS PLUG STD PIPE 1/8 STEEL SQ HD WASHER FLAT 3.2MM ID X 10MM OD SCREW PFILHM M3-0.5 X 5 SPRING, REGULATOR 45N/M 32MM INLET, TWIN REG 11.11 DIA. SEAL, INLET REGULATOR SUPPORT, INLET SEAL PIN, PIVOT ARM LEVER, REGULATOR GASKET, DIAPHRAGM RIVET .118 X .125 ALUMINUM SUPPORT, DIAPHRAGM DIAPHRAGM, TWIN REGULATOR CAP, DIAPHRAGM SUPPORT COVER,TWIN REGULATOR SCREW HHTT M4-0.7 X 8 BP Generac® Power Systems, Inc. 51 Section 12 – Warranty QUIETPACT 55, 65, and 75 Recreational Vehicle Generators CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board (CARB) and the United States Environmental Protection Agency (EPA), together with Generac Power Systems, Inc. (Generac), are pleased to explain the Emission Control System Warranty on your new engine.* New utility, and lawn and garden equipment engines must be designed, built and equipped to meet stringent anti-smog standards for the state of California and the federal government. Generac will warrant the emission control system on your engine for the periods of time listed below provided there has been no abuse, neglect, unapproved modification or improper maintenance of your engine. Your emission control system may include parts such as the carburetor, ignition and exhaust systems. Generac will repair your engine at no cost to you for diagnosis, replacement parts and labor, should a warrantable condition occur. MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE: Emissions control systems on 1997 and later model year engines are warranted for two years as hereinafter noted. If, during such warranty period, any emission-related component or system on your engine is found to be defective in materials or workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service Facility. PURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES: As the engine purchaser/owner, you are responsible for the completion of all required maintenance as listed in your factory supplied Owner’s Manual. For warranty purposes, Generac recommends that you retain all receipts covering maintenance on your engine. However, Generac cannot deny warranty solely because of the lack of receipts or for your failure to ensure the completion of all scheduled maintenance. As the engine purchaser/owner, you should, however, be aware that Generac may deny any and/or all warranty coverage or responsibility if your engine, or a part/component thereof, has failed due to abuse, neglect, improper maintenance or unapproved modifications, or the use of counterfeit and/or ‘grey market’ parts not made, supplied or approved by Generac. You are responsible for presenting your engine to a Generac Authorized Warranty Service Facility as soon as a problem occurs. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days. Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Facility. To locate the Generac Authorized Warranty Service Facility nearest you, call our toll-free number: 1-800-333-1322 IMPORTANT NOTE: This warranty statement explains your rights and obligations under the Emission Control System Warranty (ECS Warranty), which is provided to you by Generac pursuant to California and federal law. See also the “Generac Limited Warranties for Generac Power Systems, Inc.,” which is enclosed herewith on a separate sheet, also provided to you by Generac. The ECS Warranty applies only to the emission control system of your new engine. If there is any conflict in terms between the ECS Warranty and the Generac Warranty, the ECS Warranty shall apply except in circumstances where the Generac Warranty may provide a longer warranty period. Both the ECS Warranty and the Generac Warranty describe important rights and obligations with respect to your new engine. Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty service, evidence must be presented showing the date of the sale to the original purchaser/owner. The purchaser/owner shall be responsible for any expenses or other charges incurred for service calls and/or transportation of the product to/from the inspection or repair facilities. The purchaser/owner also shall be responsible for any and/or all damages or losses incurred while the engine is being transported/shipped for inspection or warranty repairs. If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at the following address: ATTENTION WARRANTY DEPARTMENT GENERAC POWER SYSTEMS, INC. P.O. BOX 297 WHITEWATER, WI 53190 Part 1 52 Generac® Power Systems, Inc. Section 12 – Warranty QUIETPACT 55, 65, and 75 Recreational Vehicle Generators EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS Warranty) for 1997 and later model year engines: (a) Applicability: This warranty shall apply to 1997 and later model year engines. The ECS Warranty Period shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter. (b) General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment, and to each subsequent purchaser/owner, that each of its engines is ... (1) Designed, built and equipped so as to conform with all applicable regulations adopted by the EPA and CARB pursuant to their respective authority, and (2) Free from defects in materials and workmanship which, at any time during the ECS Warranty Period, may cause a warranted emissions-related part to fail to be identical in all material respects to the part as described in the engine manufacturer’s application for certification. (c) The ECS Warranty only pertains to emissions-related parts on your engine, as follows: (1) Any warranted, emissions-related parts that are not scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (2) Any warranted, emissions-related part that is scheduled only for regular inspection as specified in the Owner’s Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary” shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (3) Any warranted, emissions-related part that is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection (4) below. Any such emissions-related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part. (4) Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a Generac Authorized Warranty Service Facility. (5) When the engine is inspected by a Generac Authorized Warranty Service Facility, the owner shall not be held responsible for diagnostic costs if the repair is deemed warrantable. (6) Generac shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of any emission-related part covered by the ECS Warranty. (7) Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts. (8) Any Generac authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repairs and will be provided without charge to the purchaser/owner. Such use shall not reduce Generac’s ECS Warranty obligations. (9) Unapproved, add-on, modified, counterfeit and/or ‘grey market’ parts may not be used to modify or repair a Generac engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. Generac shall not be held liable hereunder for failures of any warranted parts of a Generac engine caused by the use of such an unapproved, add-on, modified, counterfeit and/or ‘grey market’ part. EMISSION RELATED PARTS INCLUDE THE FOLLOWING: 1) Fuel Metering System: 1.1) Gasoline carburetor assembly and its internal components (if so equipped). a) Fuel filter (if so equipped) b) Carburetor gaskets c) Fuel pump (if so equipped) 1.2) LPG carburetion assembly and its internal components (if so equipped). a) Fuel controller (if so equipped) b) Mixer and its gaskets (if so equipped) c) Carburetor and its gaskets (if so equipped) d) Primary gas regulator (if so equipped) e) LP liquid vaporizer (if so equipped) 2) Air Induction System including: a) Intake pipe/manifold b) Air cleaner 3) Ignition System including: a) Spark plug b) Ignition module 4) Catalytic Muffler Assembly (if so equipped) including: a) Muffler gasket b) Exhaust manifold 5) Crankcase Breather Assembly including: a) Breather connection tube *Generac engine types covered by this warranty statement include the following: 1) Utility 2) Lawn and Garden Equipment 3) Recreational Vehicle (RV) Generator 4) Industrial Mobile (IM) Generator Part 2 Generac® Power Systems, Inc. 53 Section 12 – Warranty QUIETPACT 55, 65, and 75 Recreational Vehicle Generators GENERAC POWER SYSTEMS’ THREE-YEAR LIMITED WARRANTY FOR RECREATIONAL VEHICLE GENERATORS NOTE: ALL UNITS MUST BE INSTALLED BY GENERAC POWER SYSTEMS AUTHORIZED SERVICE FACILITIES. For a period of 3 (three) years or 2,000 (two thousand) hours of operation from the date of original sale, whichever occurs first, Generac Power Systems, Inc. (Generac) will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Facility, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Facility. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac generators sold and rated for “Recreational Vehicle” (RV) applications, as Generac has defined Recreational Vehicle generator applications. This warranty is effective only upon Generac’s receipt, from the original purchaser/owner, of a completed Warranty Registration Card. This card is the only valid registration identification and must be presented at time of request for warranty service. Claims will not be accepted without presentation of the Warranty Registration Card. The factory recommends exercising the unit one half-hour every season. WARRANTY SCHEDULE – COMMERCIAL APPLICATIONS YEAR ONE – 100% (one hundred percent) coverage on part(s), labor, removal and reinstallation listed: • Engine – All components • Alternator – All components WARRANTY SCHEDULE – CONSUMER/PERSONAL APPLICATIONS YEARS ONE AND TWO – 100% (one hundred percent) coverage on part(s), labor, removal and reinstallation listed: • Engine – All components • Alternator – All components YEAR THREE – 100% (one hundred percent) only on selected part(s) and labor listed (Any labor and part(s) not listed, and removal and reinstallation are the owner’s responsibility): • Rotor, Stator, Computer Control Board, (if applicable with regard to the generator) Cylinder Block, Cylinder Head, Crankshaft, Piston(s), Valve, Valve Lifter(s), Intake and Exhaust Manifolds Generac RV generators manufactured prior to December 31, 1997, DO NOT have a transferable warranty. Generac RV generators manufactured after January 1, 1998, have a transferable warranty to the second owner ONLY for the remainder of the three-year limited warranty. Proof-of-purchase is required and must be presented to a Generac Authorized Warranty Service Facility prior to the performance of any warranty service. All warranty expense allowances are subject to the conditions defined in Generac’s SUPER SERV ICE INFORMATION MANUAL. THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING: • Generac Guardian generators that utilize non-Generac replacement parts. • Costs of normal maintenance, adjustments, installation and start-up. • Failures caused by any contaminated fuels, oils, coolants or lack of proper fluid amounts. • Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper installation. As with all mechanical devices, the Generac engines need periodic part(s) service and replacement to perform well. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine. • Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane. • Damage related to rodent infestation. • Products that are modified or altered in a manner not authorized by Generac in writing. • Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s). • Failure due to misapplication. • Telephone, cellular phone, facsimile, internet access or other communication expenses. • Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period. • Expenses related to "customer instruction" or troubleshooting where no manufacturing defect is found. • Rental equipment used while warranty repairs are being performed. • Overnight freight costs for replacement part(s). • Overtime labor. • Starting batteries, fuses, light bulbs and engine fluids. THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC'S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state. GENERAC® POWER SYSTEMS, INC. P.O. BOX 297 • WHITEWATER, WI 53190 Part No. 0E1015 Revision B (08/30/02) Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:08:30 08:52:55-05:00 Modify Date : 2003:04:28 16:53:45-05:00 Subject : Guardian RV Owner's Manual for Quietpact 75D, Model 4270-2 Page Count : 56 Creation Date : 2002:08:30 13:52:55Z Mod Date : 2002:08:30 13:52:55Z Producer : Acrobat Distiller 5.0 (Windows) Author : bforrett Metadata Date : 2002:08:30 13:52:55Z Creator : bforrett Title : 0E1015RevB.qxdEXIF Metadata provided by EXIF.tools