STANDBY GENERATORS

8 kW - 10 kW - 14 kW
Air-Cooled Gas Engine Generator Sets
Includes:
• True Power® Electrical Technology
•T
 wo Line LCD Digital Controller
(10 kW & 14 kW)

Continuous Standby Power Rating
Model 005518-1 (Steel - Bisque) - 8 kW 60Hz
Model 005520-1 (Steel - Bisque) - 10 kW 60Hz
Model 005522-1 (Steel - Bisque) - 14 kW 60Hz

•E
 lectronic Governor
(10 kW & 14 kW)
•E
 xternal Main Circuit Breaker
& System Status LED
(10 kW & 14 kW)
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Natural Gas or LP Gas Operation
• UL 2200 Listed

FEATURES
¡	INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.”
But it doesn’t stop there. Total commitment to component testing,
reliability testing, environmental testing, destruction and life testing,
plus testing to applicable CSA, NEMA, EGSA, and other standards,
allows you to choose GENERAC POWER SYSTEMS with the
confidence that these systems will provide superior performance.
¡	TRUE POWER® ELECTRICAL TECHNOLOGY: Superior harmonics
and sine wave form produce less than 5% Total Harmonic Distortion for
utility quality power. This allows confident operation of sensitive electronic
equipment and micro-chip based appliances, such as variable speed HVAC.
¡	 TEST CRITERIA:
	
	
PROTOTYPE TESTED	
	
	 SYSTEM TORSIONAL TESTED	

	 NEMA MG1-22 EVALUATION
	 MOTOR STARTING ABILITY

¡	SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.

¡	SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component.

¡	GENERAC TRANSFER SWITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.

®

INSTALLATION
SYSTEM

UNIT

CONTROLS

TRANSFER
SWITCH

GENERATOR

ENGINE

FEATURES	

Standby Generator - 8 kW - 10 kW - 14 kW

•Generac (OHVI) Design

Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma
moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of
engine wear, the OHVI has a significantly longer life than competitive engines.

•”Spiny-lok” cast iron cylinder walls

Rigid construction and added durability provide long engine life.

•Electronic ignition/spark advance

These features combine to assure smooth, quick starting every time.

•Full pressure lubrication system

Superior lubrication to all vital bearings means better performance, less maintenance and
significantly longer engine life. Now featuring a 2 year/200 hour oil change interval.

•Low oil pressure shutdown system

Superior shutdown protection prevents catastrophic engine damage due to low oil.

•High temperature shutdown

Prevents damage due to overheating.

•Revolving field

Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.

•Skewed rotor (8 & 10 kW)
Skewed stator (14 kW)

Produces a smooth output waveform for compatibility with electronic equipment.

•Displaced phase excitation

Maximizes motor starting capability.

•Automatic voltage regulation

Regulates the output voltage to ±2% prevents damaging voltage spikes.

•UL 2200 Listed

For your safety

Sold separately

•Manual/Auto/Off switch

Selects the operating mode.

•Utility voltage sensing

Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage.

•Utility interrupt delay

Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds.

•Engine warm-up

Ensures engine is ready to assume the load, setpoint approximately 10 seconds.

•Engine cool-down

Allows engine to cool prior to shutdown, setpoint approximately 1 minute.

•Seven day exerciser

Operates engine to prevent oil seal drying and damage between power outages.

•Timed Trickle Battery charger

Maintains battery charge level to insure starting.

•Main Line Circuit Breaker

Protects generator from overload.

•Electronic governor (10 & 14 kW)

Maintains constant 60 Hz frequency.

•Weather protective enclosure

Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability.

•Enclosed critical grade muffler

Quiet, critical grade muffler is mounted inside the unit to prevent injuries.

•Small, compact, attractive

Makes for an easy, eye appealing installation.

•1’ Flexible Fuel Line Connector

Easy Installation

•Composite Mounting Pad

SPECIFICATIONS
GENERATOR
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current
240 Volts
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)

Unit Weight
Dimensions (L” x W” x H”)
Sound output in dB(A) at 23 ft. with generator operating at normal load

®

Model 05518 (8 kW)

Model 05520 (10 kW)

Model 05522 (14 kW)

8,000 Watts*
7,000 Watts*
120/240

10,000 Watts*
9,000 Watts*
120/240

14,000 Watts*
13,000 Watts*
120/240

33.3 LP/29.2 NG
Less than 5%
35 Amp
1
2
60Hz
1
Group 26R
12 Volts and
350 Cold-cranking
Amperes Minimum
340 Pounds
48 x 25 x 29
62

41.6 LP/37.5 NG
Less than 5%
45 Amp
1
2
60Hz
1
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
387 Pounds
48 x 25 x 29
63

58.3 LP/54.2 NG
Less than 5%
60 Amp
1
2
60Hz
1
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
439 Pounds
48 x 25 x 29
66

ENGINE

Model 05518 (8 kW)

Model 05520 (10 kW)

Model 05522 (14 kW)

Type of Engine
Number of Cylinders
Rated Horsepower
Displacement
Cylinder Block

GENERAC OHVI
1
14.8 @ 3,600 rpm
410cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Mechanical
9.4:1
12 Vdc
Approx. 1.5 Qts.
3,600

GENERAC OHVI V-TWIN
2
18 @ 3,600 rpm
530cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.7 Qts.
3,600

GENERAC OHVI V-TWIN
2
32 @ 3,600 rpm
992cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.9 Qts.
3,600

Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter
Operating RPM
Fuel Consumption
Natural Gas 	

cu.ft./hr.
1/2 Load
77
102
156
Full Load
139
156
220
3
Liquid Propane	
ft /hr (gal/hr)
	
1/2 Load
34 (0.94)
46 (1.25)
58 (1.56)
	
Full Load
62 (1.68)
70 (1.93)
84 (2.30)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas

	
	

CONTROLS
2-Line Plain Text LCD Display (10 & 14 kW)
Mode Switch
-Auto
-Off
-Manual/Test (start)
Engine Start Sequence
Engine Warm-up
Engine Cool-Down
Starter Lock-out
2.5 Amp Timed Trickle Battery Charger
Automatic Voltage Regulator w/Overvoltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
High Temperature Shutdown
Overcrank Protection
Safety Fuse

Simple user interface for ease of operation
Automatic Start on Utility failure. 7 day exerciser
Stops unit. Power is removed. Control and charger still operate.
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration)
10 seconds
1 minute
Starter cannot re-engage until 5 sec. after engine has stopped.
Standard
Standard
Standard
Standard, 72Hz
Standard
Standard
Standard

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).

Standby Generator - 8 kW - 10 kW - 14 kW

W2

H2
H1
H1
H2

W1

W1
W2

TRANSFER
SWITCH
8KW - 17KW
(IF SUPPLIED)

TRANSFER
SWITCH
20KW
(IF SUPPLIED)

Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

637.6
[25.1]

1218
[47.9]

731.9
[28.8]

642
[25.3]

76.2 [3.0]
PEA GRAVEL
MINIMUM

LEFT SIDE VIEW

®

1226
[48.3]

FRONT VIEW

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2009 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0181640SBY-A Printed in U.S.A. 08/27/09



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:42
Instance ID                     : uuid:0da03a52-258a-473d-8c93-9e5f458fa2cd
Document ID                     : adobe:docid:indd:d32fe439-0e78-11de-8989-9b78f80736fb
Rendition Class                 : proof:pdf
Derived From Instance ID        : 3c650268-16c4-11dd-b59a-8b9816be89af
Derived From Document ID        : adobe:docid:indd:d539b2da-f4f2-11dc-92ed-f1a3393a07b4
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:5304DCB3BEA6DD1184F0C0E94525B3F0, uuid:35DCC80B62B2DD11B577C0785C7CE1F8, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55, uuid:0A468E1451D6DB11BA63D37FD96E4FB3, uuid:D4D5F9295462DE118517FD7E3805810D, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55, uuid:e43d8012-7493-4ec9-9406-9022a2335730, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55
Manifest Reference Document ID  : uuid:5204DCB3BEA6DD1184F0C0E94525B3F0, uuid:34DCC80B62B2DD11B577C0785C7CE1F8, uuid:591AE78A2AA5DD1182E79C1AE22DF06C, uuid:09468E1451D6DB11BA63D37FD96E4FB3, uuid:D726921E8018DE11ADA69D23DE108C13, uuid:591AE78A2AA5DD1182E79C1AE22DF06C, uuid:D11F688236F1DC11BFB5F868260DEDD0, uuid:591AE78A2AA5DD1182E79C1AE22DF06C
Create Date                     : 2009:08:27 09:30:30-05:00
Modify Date                     : 2009:08:27 09:30:39-05:00
Metadata Date                   : 2009:08:27 09:30:39-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 11994 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu