Generac Standby Generators 005518 1 Users Manual
005522-1 to the manual 54f00876-c88c-49fb-b845-bafa8542ed7f
2015-01-05
: Generac Generac-Standby-Generators-005518-1-Users-Manual-166206 generac-standby-generators-005518-1-users-manual-166206 generac pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
STANDBY GENERATORS 8 kW - 10 kW - 14 kW Air-Cooled Gas Engine Generator Sets Includes: • True Power® Electrical Technology •T wo Line LCD Digital Controller (10 kW & 14 kW) Continuous Standby Power Rating Model 005518-1 (Steel - Bisque) - 8 kW 60Hz Model 005520-1 (Steel - Bisque) - 10 kW 60Hz Model 005522-1 (Steel - Bisque) - 14 kW 60Hz •E lectronic Governor (10 kW & 14 kW) •E xternal Main Circuit Breaker & System Status LED (10 kW & 14 kW) • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation • UL 2200 Listed FEATURES ¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TRUE POWER® ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC. ¡ TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY ¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ® INSTALLATION SYSTEM UNIT CONTROLS TRANSFER SWITCH GENERATOR ENGINE FEATURES Standby Generator - 8 kW - 10 kW - 14 kW •Generac (OHVI) Design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. •”Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life. •Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. •Full pressure lubrication system Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. Now featuring a 2 year/200 hour oil change interval. •Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil. •High temperature shutdown Prevents damage due to overheating. •Revolving field Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. •Skewed rotor (8 & 10 kW) Skewed stator (14 kW) Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability. •Automatic voltage regulation Regulates the output voltage to ±2% prevents damaging voltage spikes. •UL 2200 Listed For your safety Sold separately •Manual/Auto/Off switch Selects the operating mode. •Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage. •Utility interrupt delay Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds. •Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 10 seconds. •Engine cool-down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. •Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages. •Timed Trickle Battery charger Maintains battery charge level to insure starting. •Main Line Circuit Breaker Protects generator from overload. •Electronic governor (10 & 14 kW) Maintains constant 60 Hz frequency. •Weather protective enclosure Ensures protection against mother nature. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. •Small, compact, attractive Makes for an easy, eye appealing installation. •1’ Flexible Fuel Line Connector Easy Installation •Composite Mounting Pad SPECIFICATIONS GENERATOR Rated Maximum Continuous Power Capacity (LP) Rated Maximum Continuous Power Capacity (NG) Rated Voltage Rated Maximum Continuous Load Current 240 Volts Total Harmonic Distortion Main Line Circuit Breaker Phase Number of Rotor Poles Rated AC Frequency Power Factor Battery Requirement (not included) Unit Weight Dimensions (L” x W” x H”) Sound output in dB(A) at 23 ft. with generator operating at normal load ® Model 05518 (8 kW) Model 05520 (10 kW) Model 05522 (14 kW) 8,000 Watts* 7,000 Watts* 120/240 10,000 Watts* 9,000 Watts* 120/240 14,000 Watts* 13,000 Watts* 120/240 33.3 LP/29.2 NG Less than 5% 35 Amp 1 2 60Hz 1 Group 26R 12 Volts and 350 Cold-cranking Amperes Minimum 340 Pounds 48 x 25 x 29 62 41.6 LP/37.5 NG Less than 5% 45 Amp 1 2 60Hz 1 Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum 387 Pounds 48 x 25 x 29 63 58.3 LP/54.2 NG Less than 5% 60 Amp 1 2 60Hz 1 Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum 439 Pounds 48 x 25 x 29 66 ENGINE Model 05518 (8 kW) Model 05520 (10 kW) Model 05522 (14 kW) Type of Engine Number of Cylinders Rated Horsepower Displacement Cylinder Block GENERAC OHVI 1 14.8 @ 3,600 rpm 410cc Aluminum w/Cast Iron Sleeve Overhead Valve Solid-state w/Magneto Mechanical 9.4:1 12 Vdc Approx. 1.5 Qts. 3,600 GENERAC OHVI V-TWIN 2 18 @ 3,600 rpm 530cc Aluminum w/Cast Iron Sleeve Overhead Valve Solid-state w/Magneto Electronic 9.5:1 12 Vdc Approx. 1.7 Qts. 3,600 GENERAC OHVI V-TWIN 2 32 @ 3,600 rpm 992cc Aluminum w/Cast Iron Sleeve Overhead Valve Solid-state w/Magneto Electronic 9.5:1 12 Vdc Approx. 1.9 Qts. 3,600 Valve Arrangement Ignition System Governor System Compression Ratio Starter Oil Capacity Including Filter Operating RPM Fuel Consumption Natural Gas cu.ft./hr. 1/2 Load 77 102 156 Full Load 139 156 220 3 Liquid Propane ft /hr (gal/hr) 1/2 Load 34 (0.94) 46 (1.25) 58 (1.56) Full Load 62 (1.68) 70 (1.93) 84 (2.30) Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas CONTROLS 2-Line Plain Text LCD Display (10 & 14 kW) Mode Switch -Auto -Off -Manual/Test (start) Engine Start Sequence Engine Warm-up Engine Cool-Down Starter Lock-out 2.5 Amp Timed Trickle Battery Charger Automatic Voltage Regulator w/Overvoltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown High Temperature Shutdown Overcrank Protection Safety Fuse Simple user interface for ease of operation Automatic Start on Utility failure. 7 day exerciser Stops unit. Power is removed. Control and charger still operate. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) 10 seconds 1 minute Starter cannot re-engage until 5 sec. after engine has stopped. Standard Standard Standard Standard, 72Hz Standard Standard Standard Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F). Standby Generator - 8 kW - 10 kW - 14 kW W2 H2 H1 H1 H2 W1 W1 W2 TRANSFER SWITCH 8KW - 17KW (IF SUPPLIED) TRANSFER SWITCH 20KW (IF SUPPLIED) Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637.6 [25.1] 1218 [47.9] 731.9 [28.8] 642 [25.3] 76.2 [3.0] PEA GRAVEL MINIMUM LEFT SIDE VIEW ® 1226 [48.3] FRONT VIEW Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2009 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0181640SBY-A Printed in U.S.A. 08/27/09
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:42 Instance ID : uuid:0da03a52-258a-473d-8c93-9e5f458fa2cd Document ID : adobe:docid:indd:d32fe439-0e78-11de-8989-9b78f80736fb Rendition Class : proof:pdf Derived From Instance ID : 3c650268-16c4-11dd-b59a-8b9816be89af Derived From Document ID : adobe:docid:indd:d539b2da-f4f2-11dc-92ed-f1a3393a07b4 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:5304DCB3BEA6DD1184F0C0E94525B3F0, uuid:35DCC80B62B2DD11B577C0785C7CE1F8, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55, uuid:0A468E1451D6DB11BA63D37FD96E4FB3, uuid:D4D5F9295462DE118517FD7E3805810D, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55, uuid:e43d8012-7493-4ec9-9406-9022a2335730, uuid:6cec41ab-2e57-436d-8124-962f8ef1bc55 Manifest Reference Document ID : uuid:5204DCB3BEA6DD1184F0C0E94525B3F0, uuid:34DCC80B62B2DD11B577C0785C7CE1F8, uuid:591AE78A2AA5DD1182E79C1AE22DF06C, uuid:09468E1451D6DB11BA63D37FD96E4FB3, uuid:D726921E8018DE11ADA69D23DE108C13, uuid:591AE78A2AA5DD1182E79C1AE22DF06C, uuid:D11F688236F1DC11BFB5F868260DEDD0, uuid:591AE78A2AA5DD1182E79C1AE22DF06C Create Date : 2009:08:27 09:30:30-05:00 Modify Date : 2009:08:27 09:30:39-05:00 Metadata Date : 2009:08:27 09:30:39-05:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11994 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools