INSTALLATION
INSTRUCTIONS
INSTRUCTIONS
POUR L 'INSTALLA TION DE L'HUMIDIF!CA
GENERALAIRE®
TEUR
MODE-LE 65
i
POWER
HUMIDIFIER
FOR INSTALLATION ON A VERTICAL PLENUM
SURFACE OF ANY FORCED AIR FURNACE
The Generalaire® Power Humidifier
is based on the evaporative
pad method of adding moisture to the air. A polyurethane
slowly rotating drum which is wetted as it turns in an automatically
furnace.
It is recommended
pad forms the surface of a
controlled level of water and is installed on a vertical plenum surface of any forced air
that the humidifier be mounted on the return air plenum.
These illustrations show the humidifier installed with the 5" outlet
to the right. The humidifier may also be installed with the 5" outlet to the left by reversing the motor mounting plate and the by-pass collar
The float
valve must be installed on the same side as the drive motor.
L'humidificateur
electrique GENERALAIRE®
monte sur un tambour rotatif partiellement
a pour principe de disperser dans I'air I'humidite qui s'evapore a partir d'un manchon de polyurethane
immerge dans une ouvette d'eau a niveau contrele ; oet humidificateur
ohambre a air (plenum) de route fournaise a air chaud et circulation
montrent I'humidifioateur
monte aveola
forcee.
sortie de 5" pc dirigee vers la droit.
plaque de montage du moteur et le collier de derivation.
se pose sur la pardi erticale de la
On reoommande de I'installer sur la chambre a air de retour.
Les figures
Mais si I'on desire placer la sortie de " du cote gauche, il faut intervertir la
A soupape du flotteur doit etre installee du meme cete que le moteur.
.... -_.#::
.... _y@,.!p.,_,._-.-_.;_..:-.
Select location on vertical surface of return air plenum for mounting
humidifier.
level.
Stick mounting template in place.
Make sure the template is
C,#oisir I'ernplaceme,_Tt cur la pardi vertiea/e de la chambre 9 a# de retour,
,
-,i.-
puis y Pb_erle gabarit en pre,_a,_Ttsoir,, de le placer blen au niveau
l
-@-.-
Center punch the 5 mounting holes on the template and drill with a I/8" drill.
Cut out center section of template.
to the adjacent plenum.
screws.
E_end horizontal centerline from template
Remove remaining template
and start five sheet metal
Mount humidifier cabinet in level position and tighten screws.
gauge plenums use two additional
On light
screws at top of cabinet for support.
f
Apres avo# marque #emplacement
les trous avec une perceuse
centrale du G,abariL
des cmq (5) ws b I'aide d'un pointeau,
6qul:Dee d'une m_cDe de 1/8!
Prolonger la I,igne hor/zontale
faire
Decouper la pattie
depu/s le milieu du gabafit
jusqu'b /a chambre b air voisme. En/ever /e restant du gabarff et engager cmq
v/s b terb/anter/e.
Poser le bo/tier de/'humid/t/cateur
au n/veau, et serrer les
v/s. Sur une pardi mince, on doit poser deux v/s supplementa/res
,DOUrb/en supporter/e
bortieL
darts le haut
L
Scribe 5" diameter circle on plenum adjacent to humidifier for cutting bypass opening. Locate vertical centerline of circle 10" to 15" from side
of humidifier on cabinet center-line. Cut 5" hole and install by-pass pipe
by bending tabs of collar down. Drill I/8" holes through top and bottom
of 5" pipe and humidifier flange Secure with sheet metal screws
NOTE: If furnace
in by=pass pipe.
is used for summer cooling,
close inline damper
Tracer un cercle de 5 pc de diamctre sur le plenum adjacent
I'humidificateur pour decouper I'ouverture de derivation. Placer I'axe
central vertical du cercle a une distance de 10 po a 15 pc du cOte de
I'humidificateur sur I'axe central du boi"tier. Deoouper le trou de 5 poet
installer le tuyau de derivation en pliant vers le bas les pattes du
manchon
Percer des trous de 1/8 po darts les parties superieure et
inferieure du tuyau de 5 poet de la bride de I'humidifioateur
Fixer
I'aide de vis pour tOle.
REMARQUE:
Si ia fournaise eat utilisCe pour refroidir la maison
pendant Fete, former le registre incorpore dana le tuyau de
dSrivation.
Slide water pan into humidifier
as drive motor.
and assemble
Placer/a cuvette d'eau darts/'humiditicateur
flotteur du m6me c6t6 que /e moteu_
float on same side
et mstat/er le
Remove paper backing from valve hole cover plate and stick over
valve hole that is not being used.
Entever te pap/or as; dos de/a p/aque recouvrant /'or/tice de/a
soupape et te ptacer sur /'o,riflce de so_,pape qui ne servira paa
Assemble drum into humidifier cabinet by engaging drive on one end of
drum shaft with the slotted motor coupling. Place opposite end of drum
shaft in bearing. DO NOT ROTATE DRUM MANUALLY OR DAMAGE TO
MOTOR GEAR TRAIN MAY RESULT.
Assembler le tambour dans le boi'ter en glissant le dispositif d'entrainement,
situe a un bout de I'arbre, dans le couplage du moteur a fentes. Placer
I'autre exLremite de I'arbre du tambour dans le palier. NE PAS FAIR
TOURNER LE TAMBOUR A LA MAIN, CAR CA POURRAIT
ENDOMMAGER L'ENDOMMAGER
L'ENGRENAGE DU MOTEUR.
jJJ
Mount the self tapping saddle valve on a cold water pipe. Follow the
instructions on the valve package. A side or top mount is best to avoid
clogging from pipe sediment
J
J
_J
<
Montez le robinet-vanne
a etrier auto-taraudant
sur une canalisation
d'eau froide. Suives les instructions sur I'emballage du robinet. II est
preferable de le monter sur le cote ou sur le dessus de la canalisation
pour eviter que les sediments ne le bouchent.
Connect
!4."O.D.
tubing
tothesaddle
valve.Copper
tubing
requires
abrass
compression
nutandbrass
sleeve.
Plastic
tubing
requires
abrass
insert
inside
thetubing,
aplastic
sleeve
ontheoutside
withabrass
compression
nut.DONOT
USE
PLASTIC
TUBING
ONHOTWATER
ORINCONTACT
WITH
ANYHOT
PLENUM
SURFACE
ORDUCT.
_
COPPER
TUB IN G
:>
Connecter le tube de _" D.E. b la soupape de I'attache. Avec us tube es cu/vre,
on doit employer use vtrole es laitos et us 6crou b compression es laitos. Les
tubes de plastique requi@rest use pi@ce de laitos b I'ist6rieur amsi qu'use doullle
de plastique b !'ext_rieur avec us 6crou b compression es laitos. NE PAS
EMPLO YER DE TUBE EN PLASTIQUE POUR DE L'EAU CNAUDE OU S/LE
TUBE EST EN CONTACT A VEC UNE SURFACE CNAUDE DE LA CHAMBRE
AIR.
_) _j
(}
_)TUBING
PLASTIC
Open saddle valve for several seconds to flush dirt from pipe and tubing
Connect the !4." water supply tubing to the humidifier
Ouvrlr/a soupape de I'attache pesdast plusieurs secosdes pour _/im/ser
/es salet6s costesues dass le tube et /e tuyau R_'corder /e tube de ¼"
qu/ am6se /'eau b /',#um/d/t/cateur.
Install 24 V. transformer on junction box with 120 V. primary leads
connected
to 120 V. power supply. Connect humidistat in series with the 24 V.
circuit.
Follow the installation instructions supplied with the humid/star. ALL
WIRING
SHOULD COMPLY WITH LOCAL ELECTRICAL CODES
120 VOLT
PC@4ERSUPPLY
HUMIDIFIER
MOTOR
Installer us trastormateur de 24 volts sur la bo£te de josct/os es reliant/es
cbbles pr/ma/res de 120 volts "bla source de courast de 120 volts.
Connecter/'hum/d/stat
es serie avec le circuit de 24 volts. Su/vre /es
mstruct/oss toum/es aec I'hum/dlstat
TOUTE LA F/LER/E DOlT ETRE
CONFORME AU>("CODES D'ELECTRICITE LOCAO%
II L____z=_zu
TR/_!4s_OL
T
-
i
I I
HUMIDISTAT
i
,
12[t,_ I#JlRIN
G
2€V
IX_IRIH
e
TEST RUN HUMIDiFIER-Turn
on water supply and check operation of humidifier. The float should maintain a water depth of
approximately 1 1/2". The water level may be adjusted by loosening the hex nut and moving the float assembly up or down.
The humidifier motor should turn the humidifier drum when the humid/star is set to a demand setting.
ESSAI DE L'HUMIDIFICATEUR-Ouvrir
I'arrivee d'eau et verifier le fonctionnement
de I'humidificateur
Le flotteur doit
maintenir environ 1 !/2" d'eau dans la curette. On peut regler le niveau de I'eau en devissant I'ecrou hexagonal et en
rood/f/ant la hauteur de I'assemblage du flotteur, vers le haut ou vers le bas. Le moteur de I'humidifioateur devrait faire
tourner le tambour Iorsque I'humidistat est r6gle a un certain degre d'humidite
iNSTALLER:
PLEASE LEAVE HOMEOWNER'S
GUARANTEE
CARD AND MAINTENANCE
iNSTRUCTiONS
ON SADDLE VALVE.
,
I
TYPICAL INSTALLATIONS
RETURN
.O,IR
RETURN
S
HIGH
BOY
AiR
)-...
COUNTER-FLOW
LOW
BOY
PARTS LIST FOR HUMIDIFIER
ITEM NO.
N° D'AR]ICLE
7
8
9
10
11
12
13
14
15
18
17
18
l/
/
19
20
©
toTEMNO.
N° D'ARTICLE
I
PARTS N.a_E
NOM
DRUM SHAFT
Arbre du tambour
RETAINER CLIP
Agrafe
DRUM END-OPEN
Ex.tr_mite dutambour-
PART NO.
N° DE PIECE
12856
21
CANADIAN
PART NO.
65-I0
22
P-188
81-10A
23
12855
65-9
12853
65-55
24
ouvert
5
6
DRUM ASSEMBLY
Assemblage du tambour
sans le manchon
EVAPORATOR SLEEVE
Manchon _vaporateur
DRUM END-CLOSED
Extr_mit_ dutambourferm_
GENERAL
FILTERS,
USA
CANADIAN
PART NO,
PART NO,
N° DE PIECE N° DE PIECE
12858
85 GEN
12881
85-7
12852
85-2
727-11A
81-28
727-40
81-50
975-3
81-12F
747-11
81-12G
727-8
81-12A
975-6
81-12E
727-24
81-12B
975-1
81-120
P-118
81-12C
81-11
81-11
81-12
81-12
81-21
81-58
12861
85-3
81-14
81-14
12849
85-1
40-7
81-13A
81-18
81-18
12857
65-4
ECFOU
26
INC.
43800 GRAND RIVER AVE.
NOVI, MI 48376=8025
FORM NO 12870
25
NAME
NOM
COMER ASSEMBLY
(including window)
Assemblage du couvercle
avec fen_tre
WINDOW
Fen_tre
MOTOR MOUNTING
PLATE
Plaque de montage
du mdceur
COUPLING
Coupiage d'entr?nement
MOTOR ASSEMBLY
Assemblage du moteur
ORIFICE NUT
Ecrou de I'orifice
\/ALVE WASHER
Rondelle de la soupape
SPLASH GUARD
Garde contre
_claboussures
\f'AL_'E SHEILD
Ecran de la soupage
ORIFICE F0q-ING
Graniture de I'orifice
\/AL'VE SEAT
Si_ge de lasoupage
COTTER PiN
Goupille
FLOAT ARM
Bras de la soupape
FLOAT
Flotteur
FLOAT ASSEMBLY
(consi_s of items 12
thru 20)
Assemblage du flotteur
BY-PASS COLLAR
Collier de derivation
'v'ALvE HOLE COVER
Plaque de I'orifice de la
soupape
CABINET
BoRer
SPEED NUT
85-5
65.15
12854
65-8
THUMB SCREW
Mis
\_ATE R PAN
Cuvette _ eau
27
CANADIAN
GENERAL
39 CROCKFORD
SCARBOROUGN,
BLVD.
ONTARIO
FILTERS,
MI R 3B7
LTD.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Sat Mar 06 04:22:59 2010 Author : Title : Subject :EXIF Metadata provided by EXIF.tools