Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001
ti8919a
SG10 Spray Guns
Model: 255107
Maximum Working Pressure: 3600 psi (248 bar, 24.8 MPa)
- For the application of architectural paints and coatings -
The following Warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point
symbol alerts you to a general warning and hazard symbols refer to procedure-specific risks. Refer back to these Warnings.
Additional, product-specific warnings may be found throughout the body of this manual where applicable.
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured
components will pierce skin. This may look like just a
cut, but it is a serious injury that can result in amputation. Get
immediate surgical treatment.
• Do not point gun at anyone or at any part of the body.
Do not put your hand over the spray tip.
Do not stop or deflect leaks with your hand, body, glove,
or rag.
• Do not spray without tip guard and trigger guard
installed.
• Engage trigger lock when not spraying.
Follow Pressure Relief Procedure in this manual, when
you stop spraying and before cleaning, checking, or ser-
vicing equipment.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes,
in work area can ignite or explode. To help prevent
fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, ciga-
rettes, portable electric lamps, and plastic drop cloths
(potential static arc).
Keep work area free of debris, including solvent, rags
and gasoline.
• Do not plug or unplug power cords, or turn power or light
switches on or off when flammable fumes are present.
Ground all equipment in the work area. See Grounding
instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering
into pail.
• If there is static sparking or you feel a shock, stop oper-
ation immediately. Do not use equipment until you iden-
tify and correct the problem.
• Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influ-
ence of drugs or alcohol.
• Do not exceed the maximum working pressure or tem-
perature rating of the lowest rated system component.
See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equip-
ment wetted parts. See Technical Data in all equipment
manuals. Read fluid and solvent manufacturer’s warn-
ings. For complete information about your material,
request MSDS forms from distributor or retailer.
Check equipment daily. Repair or replace worn or dam-
aged parts immediately with genuine manufacturer’s
replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your
distributor for information.
Route hoses and cables away from traffic areas, sharp
edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull
equipment.
• Keep children and animals away from work area.
Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1,1,1-trichloroethane, methylene chlo-
ride, other halogenated hydrocarbon solvents or flu-
ids containing such solvents in pressurized aluminum
equipment. Such use can cause serious chemical reaction
and equipment rupture, and result in death, serious injury,
and property damage.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment
when operating, servicing, or in the operating area of
the equipment to help protect you from serious
injury. This equipment includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and
solvent manufacturer
•Gloves
Hearing protection
WARNINGS
311977C
IMPORTANT SAFETY INSTRUCTIONS. Refer to your
sprayer instruction manual for Pressure Relief, priming and
spray instructions. Keep these instructions.
Instructions/Parts
English
2311977C
Pressure Relief Procedure
Follow this Pressure Relief Procedure
whenever instructed to relieve pressure,
stop spraying, check or service equipment,
or install or clean spray tip.
1. Turn OFF power and turn sprayer pressure control to low-
est pressure setting.
2. Hold gun against side of grounded metal flushing pail.
Trigger gun into pail to relieve pressure.
If you suspect spray tip or hose is clogged or that pressure has
not been fully relieved after following the steps above, VERY
SLOWLY loosen tip guard retaining nut or hose end coupling
to relieve pressure gradually, then loosen completely. Clear
hose or tip obstruction.
Gun Trigger Lock
To prevent injury when the gun is not in use, always
set the gun’s trigger lock if unit is being shut down or
left unattended.
Setup
Make sure sprayer is turned off and unplugged from power
source. Refer to your sprayer instruction manual for priming
and spray instructions.
Connect Gun to Sprayer
1. Attach supply hose to sprayer fluid outlet.
2. Attach other end of supply hose to gun's bottom fitting.
Use two wrenches (one on the bottom fitting and one on
the hose), to tighten all connections securely.
3. Refer to sprayer instruction manual for priming
instructions.
Installing Tip (16) and Guard (15) on Gun
1.If equipment has recently been operated,
relieve pressure. Set trigger lock.
2. Using a pencil or similar object, insert seat (17) into back
of guard (15).
3. Install guard (15) over end of gun. Tighten retaining nut.
4. Insert tip (16) into slot on guard (15).
Operation
Spraying
1. Unlock trigger lock.
2. Be sure the arrow shaped tip (16) faces forward (spray).
3. Hold gun perpendicular and approximately 12-inches
(304 mm) from surface. Move gun first, then pull gun
trigger to spray a test pattern.
4. Slowly increase pump pressure until coverage is uniform
and even (see sprayer instruction manual for additional
information).
Aligning Spray
1.Relieve pressure. Set trigger lock.
2.Loosen guard retaining nut.
3.Align guard (15) horizontally to spray a
horizontal pattern.
4. Align guard (15) vertically to spray a vertical pattern.
Clearing Clogs
1. Relieve pressure. Set trigger lock.
2. Rotate tip (16) 180°. Unlock trigger lock. Trigger gun into
pail or onto ground to remove clog.
3. Set trigger lock. Rotate tip (16) 180° back to spray
position.
WARNING
WARNING
WARNING
Trigger Locked
(no spray)
Trigger Unlocked
(spray)
ti8923a ti8922a
WARNING
WARNING
WARNING
311977C 3
Maintenance
Before performing any maintenance on gun, read all warnings
on front cover of this manual and relieve pressure.
Cleaning/Replacing Filter (19)
1. Relieve pressure. Set trigger lock.
2. Unscrew hose from gun at gun swivel.
3. Remove filter (19).
4. Clean filter. Use a soft brush to loosen and remove excess
debris.
5. Insert clean filter into handle.
Cleanup
Flush gun after each work shift and store in a dry location.
To clean the handle grip, use water and a brush. For tougher
stains, use a rag wetted in paint thinner or mineral spirits to
scrub off paint. Do not operate until solvents have evaporated.
To preserve life of the handle grip, do not stretch or pull grip
from edges
Ref
No. Part. No. Description Qty
15 237859 GUARD, RAC IV;
7/8 in. (22 mm) thread
1
16 221515 TIP, spray, 515, 0.015 in. (0.381 mm)
orifice; 10-12 in. (254-304.8 mm) fan
(includes 17a and 17b)
1
17 243004 KIT, repair, gasket (includes 17a to 17b) 1
17a GASKET, tip, black rubber 1
17b SEAT, cylinder 1
19 288748 FILTER, 2-pack, 60 & 100 mesh 1
15
17b
17a
16
19
Always replace the gasket and
seat (included with tip) when you
replace a worn spray tip. See
Installing Tip (16) and Guard
(15) on Gun, page 2.
Clean the spray gun fluid filter
with compatible solvent and a
brush every time you flush the
system.
1
2
1
1
2
ti8920a
WARNING
CAUTION
Never soak gun in solvent.
Do not leave the gun or any parts in water or clean-
ing solvents.
For complete warranty information contact your local Graco distributor, call Graco customer
service: 1-800-690-2894 or visit our website: www.graco.com.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 311977
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
01/2007, Revised 2/2007