OWNER’S
MANUAL
824–001

This manual contains important
warnings and information.
READ AND RETAIN FOR REFERENCE

Rev D
Supercedes Rev. C

HYDRA-CLEAN 2000, 2800
Pressure Washers
Hydra-clean 2000
824–006 Series A

2000 psi (138 bar) Operating Pressure
2400 psi (165 bar) Maximum Working Pressure

Hydra-clean 2800
824–007, Series A

2800 psi (193 bar) Operating Pressure
3200 psi (225 bar) Maximum Working Pressure



Model 824–006

The SHERWIN–WILLIAMS COMPANY, 101 PROSPECT AVENUE, CLEVELAND, OHIO 44115

Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
804–544 Pump Service . . . . . . . . . . . . . . . . . . . . . . . . 11
804–559 Pump Service . . . . . . . . . . . . . . . . . . . . . . . . 13
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parts List & Drawing
Hydra-clean 2000 Pressure Washer . . . . . . . . . . . . 16
Hydra-clean 2800G Pressure Washer . . . . . . . . . . . 18
Pump Assembly Model 804–544 . . . . . . . . . . . . . . . . 20
Pump Assembly Model 804–559 . . . . . . . . . . . . . . . . 22
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Warning Symbol

WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.

WARNING
WARNING
INJECTION HAZARD
Spray from the gun, leaks or ruptured components can inject fluid into your body and cause serious
injury. Fluid splashed in the eyes or on the skin can also cause serious injury.
D Fluid injected into the skin may look like just a cut, but it is a serious injury. Get emergency
medical attention.
D Do not point gun at anyone or at any part of body.
D Do not stop or deflect leaks with hand, body, glove or rag.
D Do not put hand or fingers over spray tip.
D Tighten fluid connections before starting equipment.
D Engage the gun trigger safety whenever you stop spraying.
D Follow Pressure Relief Procedure on page 5 if spray tip clogs and before cleaning, checking or
servicing equipment.
D Repair or replace worn or damaged parts immediately.
D Check hoses, tubes, and coupling daily. Do not repair high pressure couplings: replace entire
hose. Fluid hoses must have spring guards on both ends to prevent kinks and rupture.



824–001

WARNING
WARNING
HAZARDOUS FLUIDS
Improper handling of hazardous fluids can cause serious injury, even death, due to splashing in eyes,
ingestion or bodily contamination.
D Know specific hazards of fluid being used.
D Store hazardous fluids in approved containers. Dispose of hazardous fluids per local, state and
national guidelines.
D Wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid manufacturer.

FUEL HAZARD
The fuel used in this unit is combustible and when spilled on a hot surface can ignite and cause a
fire.
D Do not fill the fuel tank while the engine is running or hot.

EXHAUST HAZARD
The exhaust contains poisonous carbon dioxide which is colorless and odorless.
D Do not operate this equipment in a closed building.

EQUIPMENT MISUSE HAZARD
Misuse of the pressure washer or accessories may cause them to rupture and result in fluid injection,
splashing in the eyes or on the skin, or other serious injury.
D Do not alter or modify any part or factory-set adjustment of this equipment.
D Do not exceed the maximum working pressure of any component or accessory in the system.
D Do not use any chemicals that are incompatible with the wetted parts as stated in the Technical
Data.
D Do not alter throttle setting.

824–001

3

Installation
Typical Installation – Pressure Washer
HOSE
RACK
SPRAY
GUN

SPRAY
HOSE

INLET WATER
CONNECTION
3/4” GARDEN
HOSE

Fig. 1

Check for Shipping Damage
Check the unit for any damage that may have occurred in
shipping. Notify the carrier immediately if there is any
damage.

Set Up
Connect the high pressure hose between the pump outlet
and the gun inlet. Both of these connections are made
with quick couplers.

CAUTION
Up to 100 ft (30 m) of high pressure hose may
be used. Longer hoses may affect sprayer
performance, and chemical injector performance,
if used.

Install the appropriate spray tip on the wand. See Installing and Changing Spray Tips. If you are using a
sandblaster kit, see its separate manual for installation
instructions.

4

824–001

HIGH PRESSURE
HOSE CONNECTION


Connect to Water Supply

CAUTION
Before attaching to the water supply, check your
local plumbing code regarding cross–connection
to the water supply. If required, a backflow
preventer may be installed.
If inlet water pressure is over 60 psi (4.1 bar), a
regulating water valve must be installed at the
garden hose connection.
Do not exceed 160_F (70_C) inlet water
temperature.
Connect a hose with at least a 3/4 inch (19 mm) ID from
the water supply to the unit’s 3/4 inch garden hose inlet.
The supply hose should not be more than 50 ft (15 m)
long
NOTE: The water source at the unit must have a minimum flow rate equal to that of the unit (see Technical Data, inside back cover).

Operation
Pressure Relief Procedure

WARNING
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
spraying accidentally. To reduce the risk
of an injury from accidental spray from the gun,
splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
D
D
D
D

are instructed to relieve the pressure,
stop spraying for more than 10 minutes,
check or service any of the system equipment,
or install or clean the spray nozzle.

Startup
Always use this start–up procedure to ensure that the
unit is started safely and properly.
1. Check oil levels:
NOTE: All units are equipped with a low-oil sensor that
shuts the engine off if the oil level falls below a
certain level. If the unit stops unexpectedly,
check both the oil and the fuel levels. Check the
oil level each time the unit is refueled.
2. Check fuel level.

Pressure Relief Procedure
1. Engage the trigger safety latch.
2. Turn the sprayer off.
3. Remove the ignition cable from the spark plug.
4. Shut off the water supply.

WARNING
FIRE HAZARD
Do not refuel a hot engine. Refueling a
hot engine could cause a fire. Use only
fresh, clean regular or unleaded gasoline. Close the fuel shutoff valve during
refueling.

5. Disengage the trigger safety latch and trigger the
gun to relieve pressure, and then engage the
trigger safety latch again.
6. If you suspect that the spray tip or hose is
completely clogged, or that pressure has not been
fully relieved after following the steps above:
Disengage the trigger safety latch and trigger the
gun to relieve pressure. Wrap a rag around the
hose end coupling and VERY SLOWLY loosen the
coupling to relieve pressure gradually, then loosen
completely. Now clear the tip or hose.

CAUTION
Never run the unit dry. Costly damage to the
pump will result. Always be sure the water
supply is completely turned on before operating.
3. Turn on the water supply.

824–001

5

Operation
4. Trigger the gun until water sprays from the tip
indicating that the air is purged from the system.
5. Open the fuel shutoff valve. Be sure the spark plug
ignition cable is pushed firmly onto the spark plug.
Put the switch in the “on” position and put the
throttle in the “run” position.

CAUTION
Do not allow the pressure washer to idle for more
than 10 minutes. Doing so may cause the recirculating water to overheat and seriously damage
the pump. Turn off the pressure washer if it will not
be spraying or cleaning at least every 10 minutes.
If heated inlet water is used, reduce this time
further. Do not operate the pressure washer with
the inlet water screen removed. This screen helps
keep abrasive sediment out of the pump, which
could clog the pump or damage the cylinders.
Keep this screen clean. Do not pump caustic
materials; such materials may corrode the pump
components.

CAUTION
Do not allow the starter rope to snap back against the
engine. Return it gently to prevent damage to the
recoil.

6

824–001

6. Start the engine.
NOTE: For easier starting, have one person start the
pressure washer while another person triggers
the spray gun.
If the engine is cold, completely close the engine
choke. Grasp the starter rope, brace one foot on
the pressure washer chassis and pull rope rapidly
and firmly. Continue holding the rope as it returns.
Pull and return the rope until the engine starts. In
cool weather, the choke may have to be kept
closed for 10 to 30 seconds before opening it to
keep the engine running. Otherwise, open the
choke as soon as the engine starts.
If the engine is warm, leave the choke open, or
just partly close it. Start the engine as described in
the preceding paragraph. When it starts, be sure
to open the choke completely.
7. Always engage the gun’s trigger safety latch
whenever you stop spraying, even for a moment,
to reduce the risk of fluid injection or splashing in
the eyes or on the skin if the gun is bumped or
triggered accidentally.
8. Always observe the following CAUTIONS to avoid
costly damage to the pressure washer.
9. See the sandblaster kit manual for detailed cleaning information if this accessory is used.

Operation
Trigger Safety Latch

Installing and Changing Spray Tips

WARNING
WARNING
To reduce the risk of serious bodily injury, including
fluid injection, splashing in the eyes or on the skin,
always engage the trigger safety latch whenever
spraying stops, even for a moment.In the engaged
position, the trigger safety latch prevents the gun
from being triggered accidentally by hand or if it is
dropped or bumped. Be sure the latch is pushed
fully down when engaging it or it cannot prevent
the gun from being triggered. See Figure 2.

To reduce the risk of serious bodily injury, including
fluid injection or splashing in the eyes or onto the
skin, use extreme caution when changing spray
tips. always follow the procedure below.
1. Follow the Pressure Relief Procedure.
2. Point the gun and wand away from yourself and
anyone else.
3. Spray tips have a 4– or 5–digit number on them.
The first two digits are the spray angle. Select the
spray tip appropriate for your application.
Spray Tip Number

Spray Pattern Fan Angle

00XXX

0_, blaster (red)

15XXX

15_ (yellow)

25XXX

25_ (green)

40XXX

40_ (white)

NOTE: The chemical injector tip is brass, has a large
opening and a black plastic cap.
4. Without holding your hand over the spray tip (A),
pull back the quick coupler ring (B). Remove the
current tip and/or install a different one, and then
push back the ring. See Figure 3.
5. Pull on the tip to be sure the tip is secure before
starting to spray again.
6. Tip holding holes are provided on the chassis.

CAUTION

TRIGGER SAFETY LATCH SHOWN ENGAGED

To avoid blowing the o-ring out of the quick coupler, due to the high pressure in the system, never
operate the pressure washer without a tip securely
mounted in the quick coupler.

B
A
04612

TRIGGER SAFETY LATCH SHOWN DISENGAGED
Figure 2
04929

Figure 3
824–001

7

Operation
Shutdown, Flushing and Storage
NOTE: An anti–freeze flush kit 802–327 is available to
make flushing easier.

CAUTION
If water does freeze in the pressure washer, thaw it
in a warm room before trying to start it. Do not pour
hot water on or into the pump; it may crack the
ceramic plungers!
1. If the pressure washer will be exposed to freezing
temperatures, drain all water out of the pump. If it
must be stored in freezing temperatures, flush the
unit with a 50% anti–freeze solution. Relieve
pressure. Flush the pressure washer before using
it again to remove the anti–freeze.
2. Before long-term (overnight) storage or transporting of unit, disconnect the water supply, and turn
off the fuel supply valve.
3. After each use, wipe all surfaces of the pressure
washer with a clean, damp cloth.
4. Perform the appropriate maintenance. See maintenance chart.

Maintenance
Observing regular maintenance intervals helps ensure
that you get maximum performance and life from the
pressure washer.
There is a break-in period for the engine, pump and
gear reducer (if used). After changing the oil in these
components following their respective break-in periods,
the interval between required changes is longer.
If the unit is operating in dusty conditions, these maintenance checks should be made more often.

8

824–001

WARNING
To reduce the risk of serious bodily injury, including
fluid injection, splashing in the eyes or on the skin
or injury from moving parts, always follow the
Pressure Relief Procedure on page 5 before
proceeding.

Interval

What to do

Daily

Clean water inlet screen and filter.
Check engine and pump oil levels.
Fill as necessary. Check gasoline
level. Fill as necessary.

After first 5
hours of operation

Change engine break–in oil. Drain
oil when warm. Use SAE 30 or
10W–30 detergent oil.

Each 25 hours
of operation

Clean and remove air cleaner
foam. Wash with water and detergent. Dry thoroughly. Rub with oil
and squeeze to distribute oil.

After first 50
hours of operation

Change pump break-in oil. Use
SAE 20 or 30 non-detergent oil.

Each 100
hours of operation
or 3 months

Clean or replace paper air cleaner
cartridge. Tap gently to remove
dirt. Change engine oil. Use SAE
30 or 10W–30 detergent oil.

Each 500
hours of operation
or 6 months

Change pump oil. Use SAE 20 or
30 non-detergent oil.

Troubleshooting
WARNING
To reduce the risk of serious injury, including fluid injection and splashing in the eyes, or on the skin, always
follow Pressure Relief Procedure on page 5 before proceeding.
Problem
Engine will not start
or is hard to start

Cause
No gasoline in fuel tank or carburetor.
Low oil.
Start/Stop switch in Stop position.
Water in gasoline or old fuel.
Choked improperly. Flooded engine.

Engine misses or
lacks power

Low pressure and/or
pump runs rough

Water leakage from
under pump manifold
Water on oil side of
pump

Dirty air cleaner filter.
Spark plug dirty, wrong gap or wrong
type.
Spray gun closed.
Partially plugged air cleaner filter.

Solution
Fill the tank with gasoline, open fuel shut off valve.
Check fuel line and carburetor.
Add to proper level.
Move switch to start position.
Drain fuel tank and carburetor. Use new fuel and dry
spark plug.
Open choke and pull engine several times to clear out
gas. Use a dry sprark plug.
Remove and clean.
Clean, adjust the gap or replace.
Trigger spray gun while spraying.
Remove and clean.

Spark plug dirty, wrong gap or wrong
plug type.
Worn or wrong size tip.

Clean, adjust the spark plug gap or replace.

Inlet filter clogged.
Worn packings, abrasives in water or
natural wear.
Inadequate water supply.
Fouled or dirty inlet or discharge valves.
Restricted inlet.
Worn inlet or discharge valves.
Leaking high pressure hose.
Worn packings.

Clean. Check more frequently.
Check filter. Replace packings. See PUMP SERVICE,
page 13.
Check water flow rate to pump.
Clean inlet and discharge valve assemblies. Check
filter.
Check garden hose, may be collapsed or kinked.
Replace worn valves. See PUMP SERVICE, page 13.
Replace high pressure hose.
Install new packings. See PUMP SERVICE, page 13..

Humid air condensing inside crankcase.

Change oil as specified in Maintenance, page 8.

Worn packings.
Oil seals leaking.

Install new packings. See PUMP SERVICE, page 13.
Install new oil seals. See PUMP SERVICE, page 13.

Replace with tip of proper size.

824–001

9

Problem
Frequent or premature failure of the
packings

Cause
Scored, damaged or worn plungers.

Install new plungers. See PUMP SERVICE, page 13.

Abrasive material in the fluid being
pumped.
Inlet water temperature too high.

Install proper filtration on pump inlet plumbing.

Overpressurizing pump.
Excessive pressure due to partially
plugged or damaged tip.
Pump running too long without spraying.

Strong surging at inlet and low pressure
on discharge side

10

824–001

Solution

Running pump dry.
Foreign particles in the inlet or discharge
valve or worn inlet and/or discharge
valves.

Check water temperature; may not exceed
160_F(70_C).
Do not modify any factory–set adjustments. See
EQUIPMENT MISUSE HAZARD on page 3.
Clean or replace tip. See Installing and Changing
Spray Tips on page 7.
Never run pump more than 10 minutes without spraying.
Do not run pump without water.
Clean or replace valves. See PUMP SERVICE, page
13.

804–544 Pump Service
WARNING
To reduce the risk of serious bodily injury, including
fluid injection, splashing in the eyes or on the skin,
or injury from moving parts, always follow the
Pressure Relief Procedure Warning on page 5
before proceeding.

NOTE:

NOTE:

The following metric wrenches are needed: 5
mm, 13 mm and 22 mm. Repair kits are
available. Refer to the individual repair
sections and the pump parts page for more
details. For the best results, use all parts in
the kits.
There is a tool kit to aid in servicing the
pump. P/N 800–271 includes tools to aid in
the removal of packing retainers.

Valves
NOTE:

For a set of six valves, order P/N 801–472.

1. Remove the hex plug from the manifold using a 22
mm socket.
2. Examine the o–ring under the hex plug and
replace it if it is cut or distorted.
3. Remove the valve assembly from the cavity; the
assembly may come apart.
4. Install the new valve. Install the o–ring and hex
plug; torque to 33 ft–lb (45 Nm).
NOTE:

Retorque the plug after 5 hours of operation.

Pumping Section
1. Remove the eight capscrews and lockwashers
from the manifold using a 5 mm wrench.

2. Carefully separate the manifold from the
crankcase.
NOTE:

It may be necessary to tap the manifold
lightly with a soft mallet to loosen.

CAUTION
Keep the manifold properly aligned with the ceramic plungers when removing to avoid damage to
the plunger or seals.

3. Carefully examine each plunger for any scoring or
cracking and replace as necessary.

Servicing the Plungers
NOTE:

Plunger repair kit, P/N 801–474 is available
to replace retainers, o–rings, washers and
backup rings for three cylinders.

1. Loosen the plunger retaining nut five to six turns,
using a 13 mm wrench. Push the plunger towards
the crankcase to separate the plunger and
retaining screw.
2. Remove the nut from the plunger and examine the
o–ring, backup ring and copper bearing/gasket
washer. Replace these parts, if necessary, using
kit 801–474.
3. Remove the plunger and flinger from the plunger
shaft. Clean, examine and replace parts as
necessary.
4. Inspect the plunger shaft for oil leakage from the
crankcase. If leaking is obvious, replace the oil
seals. Otherwise, DO NOT remove these seals as
they cannot be reused. An oil seal kit is available
to replace the seals.
5. Lightly grease the flinger and oil seal, if it is being
replaced and replace them on the plunger shaft.
Then install the plunger.

824–001

11

804–544 Pump Service
6. Lightly grease the retaining screw and the outer
end of the plunger. Place the washer, o–ring and
backup ring around the screw and install the nut
through the plunger. Torque to 11 ft–lb (15 Nm).

NOTE:

If you plan to replace the packings, refer to
Servicing the V–Packings.

7. Lubricate the outside of each plunger. Slide the
manifold onto the crankcase, being careful not to
damage the seals.

8. Install the capscrews and washers finger–tight.
Torque the screws to 8.8 ft–lb (12 Nm) following
the tightening pattern (Figure 4). Uneven tightening
may cause the manifold to bind or jam.

5

1

4

7

8

3

2

6

Figure 4

12

824–001

Servicing the V-Packings
NOTE:

There are two types of packing kits: one is
packings only, the other includes the
packings, rings and retainers.

1. Remove the manifold as outlined in the Pumping
Section.
2. Carefully pull the packing retainer from the
manifold. Examine the o-ring and replace it if it is
cut or damaged.
3. Remove the v-packing and head ring. Pull out the
intermediate retainer ring. Remove the second
v–packing and second head ring.
4. Inspect all parts and replace as necessary.
5. Thoroughly clean the packing cavities and
examine for debris or damage.
6. Lightly grease the packing cavities and then
replace the packings in the following order: head
ring, v-packing, intermediate ring, head ring,
v-packing and packing retainer with the o-ring
installed in the retainer groove.

CAUTION
Install the parts in the proper order and facing the
correct direction. Improperly installed parts will
cause a malfunction.

7. Reassemble the manifold as instructed in
Servicing the Plungers.

804–559 Pump Service
WARNING
To reduce the risk of serious bodily injury, including
fluid injection, splashing in the eyes or on the skin,
or injury from moving parts, always follow the
Pressure Relief Procedure Warning on page 5
before proceeding.

NOTE:

NOTE:

The following metric wrenches are needed: 6
mm, 13 mm and 27 mm. Repair kits are
available. Refer to the individual repair
sections and the pump parts page for more
details. For the best results, use all parts in
the kits.
There is a tool kits to aid in servicing the
pump. P/N 800–271 includes tools to aid in
the removal of packing retainers.

Valves
NOTE:

For a set of six valves, order P/N 801–472.

1. Remove the hex plug from the manifold using a 27
mm socket.
2. Examine the o–ring under the hex plug and
replace it if it is cut or distorted.
3. Remove the valve assembly from the cavity; the
assembly may come apart.
4. Install the new valve. Install the o–ring and hex
plug; torque to 73 ft–lb (99 Nm).
NOTE:

Retorque the plug after 5 hours of operation.

Pumping Section
1. Remove the eight capscrews and lockwashers
from the manifold using a 6 mm wrench.

2. Carefully separate the manifold from the
crankcase.
NOTE:

It may be necessary to tap the manifold
lightly with a soft mallet to loosen.

CAUTION
Keep the manifold properly aligned with the ceramic plungers when removing to avoid damage to
the plunger or seals.

3. Carefully examine each plunger for any scoring or
cracking and replace as necessary.

Servicing the Plungers
NOTE:

Plunger repair kit, P/N 801–474 is available
to replace retainers, o–rings, washers and
backup rings for three cylinders.

1. Loosen the plunger retaining nut five to six turns,
using a 13 mm wrench. Push the plunger towards
the crankcase to separate the plunger and
retaining screw.
2. Remove the nut from the plunger and examine the
o–ring, backup ring and copper bearing/gasket
washer. Replace these parts, if necessary, using
kit 801–474.
3. Remove the plunger and flinger from the plunger
shaft. Clean, examine and replace parts as
necessary.
4. Inspect the plunger shaft for oil leakage from the
crankcase. If leaking is obvious, replace the oil
seals. Otherwise, DO NOT remove these seals as
they cannot be reused. An oil seal kit is available
to replace the seals.
5. Lightly grease the flinger and oil seal, if it is being
replaced and replace them on the plunger shaft.
Then install the plunger.

824–001

13

804–559 Pump Service
6. Lightly grease the retaining screw and the outer
end of the plunger. Place the washer, o–ring and
backup ring around the screw and install the nut
through the plunger. Torque to 14.4 ft–lb (19.5
Nm).

NOTE:

If you plan to replace the packings, refer to
Servicing the V–Packings.

7. Lubricate the outside of each plunger. Slide the
manifold onto the crankcase, being careful not to
damage the seals.

8. Install the capscrews and washers finger–tight.
Torque the screws to 22 ft–lb (30 Nm) following
the tightening pattern (Fig. 4). Uneven tightening
may cause the manifold to bind or jam.

5

1

4

7

8

3

2

6

Servicing the V-Packings
NOTE:

There are two types of packing kits: one is
packings only, the other includes the
packings, rings and retainers.

1. Remove the manifold as outlined in the Pumping
Section.
2. Carefully pull the packing retainer from the
manifold. Examine the o-ring and replace it if it is
cut or damaged.
3. Remove the v-packing and head ring. Pull out the
intermediate retainer ring. Remove the second
v–packing and second head ring.
4. Inspect all parts and replace as necessary.
5. Thoroughly clean the packing cavities and
examine for debris or damage.
6. Lightly grease the packing cavities and then
replace the packings in the following order: head
ring, v-packing, intermediate ring, head ring,
v-packing and packing retainer with the o-ring
installed in the retainer groove.

CAUTION

Figure 4

14

824–001

Install the parts in the proper order and facing the
correct direction. Improperly installed parts will
cause a malfunction.

7. Reassemble the manifold as instructed in
Servicing the Plungers.

Accessories
Water Sandblasting Kit 800–120

Anti–freeze Flush Kit 802–327

For abrasive cleaning of stubborn dirt and paint.
Requires a spray tip which is not included in kit (1535
uses 805–325, 2030 uses 805–313, 2540 uses
805–321, and 3040 uses 805–317).

For flushing system with 50% anti-freeze solution prior
to transporting or storing pressure washer in below
freezing temperatures.

Technical Data
Model 824–006

Model 824–007

Engine
(4 cycle, air cooled)

5.5 HP Honda OHV

9 HP Honda OHV

Gasoline Tank Capacity

3.8 quarts (3.6 liter)

6.2 quarts (6.1 liter)

Water Pump Maximum Working Pressure
Water Pump Maximum Flow

2000 psi (138 bar)
3 gpm (11 lpm)

2800 psi (193 bar)
3.5 gpm (13 lpm)

Inlet Hose Connection

3/4” garden hose (f)

3/4” garden hose (f)

Weight (without gun and hose)

79 lb (36 kg)

110 lb (50 kg)

Dimensions
Length

34.5” (914mm)

34.5” (914mm)

Width

22” (533mm)

22” (533mm)

Height

23.5” (572mm)

23.5” (572mm)

160_F (70_C)

160_F (70_C)

Maximum Inlet Water Temperature
Wetted Parts
High Pressure Hose
Bypass Hose
Pressure Washer
(including fittings)

Acrylonitrile and Buna-N cover and tube
Synthetic yarn and EPDM
Anodized aluminum, Aluminum or bronze alloys, Brass Copper, Nylon–PTFEr composite,
Ceramic, Buna-N, Cotton phenolic, 303, 304, and 316 Stainless steel, Polymide–12
thermoplastic, PTFEr, Carbon steel, Zinc with or without yellow chromate plate

PTFE r is a registered trademark of the DuPont Company
.

824–001

15

Hydra-Clean 2000 Pressure Washer – Parts
Model 824–006, Series A

37


56

1

34



53
39

41

38



4

51

47
59

44

54
45
55

59


4

33
6
5

3

25,26,27,46,57
4

24

13
49

28
23

48

4 10

8

9

7

6

40
16
12 16

22
15
6

11

14

21

8

20
04999A

19
18

32
17

31


Apply sealant to threads



Supplied with pump



Supplied with engine
29

16

824–001

30

04999

Hydra-Clean 2000 Pressure Washer – Parts
USE ONLY GENUINE GRACO PARTS AND ACCESSORIES
Models 824–006, Series A
Ref.
No.
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

Part No.
802–264
804–510
804–533
804–523
111–040
101–545
154–636
804–511
804–512
804–554
804–516
100–527
804–509
804–514
114–412
804–515
100–643
109–059
100–086
102–040
804–530
108–789
801–012
805–427
805–428
805–429
804–524
804–479
801–569
801–568

Description
ENGINE, 5.5 hp
HANDLE, lift
SCREW, cap, flange, 5/16–18
WASHER, handle
NUT, Lock 5/16–18
PIN, cotter 1/8 dia. x 1”
WASHER, plain, 1–3/16
WHEEL, pneumatic
SPACER
AXLE
PLATE, motor mounting
WASHER, plain
HANDLE
PLATE, pump
SCREW, flange, hex hd.
PLATE, bottom
SCREW, cap, sch, 14–20 x .75
PAD, rubber
WASHER, plain, 3/16
NUT, lock, hex, 1/4–20
SCREW, mach, flthd, 3/8–16
KNOB
GROMMET, rubber
TIP, spray
TIP, spray
TIP, spray
LABEL
HOSE, high pressure 3/8 x 50’
QUICK COUPLER, 3/8 female
QUICK COUPLER, 3/8 male

Qty.
1
1
6
2
14
2
4
2
2
1
1
2
1
1
8
1
4
2
4
4
1
1
6
1
1
1
1
1
1
1

Ref.
No.

Part No.

32

800–392

32a
32b
32c
32d
32e

801–569
801–009
801–134
801–674
803–350

33
34
37
38
39
40
41
44
45
46
47

804–529
804–531
290–013
802–363
820–137
290–131
290–133
801–683
803–857
805–430
804–543

48
49
51
53
54
55
56
57
59

801–210
100–214
800–742
804–546
804–551
801–112
804–275
805–520
804–570

Description

Qty.

GUN & WAND ASSEMBLY
(includes 32a – 32f),
QUICK COUPLER, female 3/8
QUICK COUPLER, female 1/4
WAND, 32”
SLEEVE, 28”
GUN, Spray (see Inst. Manual
308–511)
HOLDER, gun
PUMP ASSEMBLY (see page 20)
LABEL
LABEL, caution
LABEL
LABEL, warning
LABEL
STRAINER
COUPLER, sst
TIP
KIT, unloader
includes items 54 and 59
SCREW
WASHER, lock
VALVE, thermal relief
VALVE, relief
INJECTOR, chemical
SCREEN
TUBE, chemical
TIP, chemical injector
GASKET

824–001

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
4

17

Hydra-Clean 2800G Pressure Washer – Parts
Model 824–007, Series A

1

1

34

2

37

39
38
44

41
56

3

57

4

50
59
58
45
31

51
59
58

2

4
33

6

46

5
3

24

25,26,27,28,42,

16
13
48
47

41
23

4 10 8

9

6

40
16
22

12
15

16

11

14

6
21

8

32

20
19
18

17
31

1

Apply sealant to threads

2

Supplied with pump

3

Supplied with engine
29

18

824–001

30

05923A

7

Hydra-Clean 2800G Pressure Washer – Parts
USE ONLY GENUINE GRACO PARTS AND ACCESSORIES
Models 824–007, Series A
Ref.
No.
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Part No.
803–900
804–510
110–837
804–523
111–040
101–545
154–636
804–511
804–512
804–554
804–516
100–527
804–509
804–514
114–412
804–515
100–643
109–059
100–086
102–040
804–530
108–789
801–012
805–427
805–428
805–429
805–430
804–479
801–569

Description
ENGINE, 9 hp
HANDLE, lift
SCREW, cap, flange, 5/16–18
WASHER, handle
NUT, Lock 5/16–18
PIN, cotter 1/8 dia. x 1”
WASHER, plain, 1–3/16
WHEEL, Pneumatic
SPACER
AXLE
PLATE, motor mounting
WASHER, Plain
HANDLE
PLATE, pump
SCREW, Flange, Hex Hd.
PLATE, bottom
SCREW, cap, sch, 14–20 x .75
PAD, rubber
WASHER, plain, 3/16
NUT, lock, hex, 1/4–20
SCREW, mach, flthd, 3/8–16
KNOB
GROMMET, Rubber
TIP, spray
TIP, spray
TIP, spray
TIP, spray
HOSE, High Pressure 3/8 x 50’
QUICK COUPLER, 3/8 female

Qty.
1
1
6
2
14
2
4
2
2
1
1
4
1
1
8
1
4
2
4
4
1
1
6
1
1
1
1
1
1

Ref.
No.

Part No.

31
32

801–568
800–392

32a
32b
32c
32d
32e

801–569
801–009
801–134
801–674
803–350

33
34
37
38
39
40
41
42
44
45
46
47
48
50
51

804–529
804–559
290–013
802–363
820–137
290–131
820–137
805–520
804–536
804–553
804–051
801–210
100–214
804–397
804–567

56
57
58
59

804–275
801–683
804–569
804–570

Description

Qty.

QUICK COUPLER, Male 3/8
1
GUN & WAND ASSEMBLY
1
(includes 32a – 32f), Model 1535
QUICK COUPLER, Female 3/8
1
1
QUICK COUPLER, Female 1/4
1
WAND, 32”
1
SLEEVE, 28”
1
GUN, Spray
(see Manual308–511)
HOLDER, gun
1
PUMP ASSEMBLY (see page 22) 1
LABEL
1
LABEL, caution
1
LABEL
1
LABEL, warning
1
LABEL
1
1
TIP, spray
1
VALVE, relief
1
KIT, repl, injector
SCREEN
1
SCREW
4
4
WASHER, lock
1
VALVE, thermal relief
1
KIT, unloader
includes items 45, 58 and 59
TUBE, chemical
1
STRAINER
1
2
GASKET, unloader
GASKET
2

824–001

19

Pump Assembly – Parts
Model 804–544

33
34

35
32

25
16

30 31

23

28
26

15
14
17

36

37

29

27

24

13
22

12

5

1

21

11

59

10
58

49
50

57
20
19
3

18
9

4

8
6

17
15
16

7

2
56
55

2

54
51
53
52
05001

20

824–001

Pump Assembly – Parts
USE ONLY GENUINE GRACO PARTS AND ACCESSORIES
Model 804–544
REF
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

PART
NO.

DESCRIPTION
CRANKCASE
801-484 PLUG
802-344 O-RING
PROTECTOR
KIT 83
SEAL, Oil
PLUG
MANIFOLD
WASHER
SCREW
KIT 1
O-RING
KIT 1
SEAT, Valve
KIT 1
PLATE, Valve
KIT 1
SPRING
KIT 1
CAGE, Valve
KIT 84
O-RING
KIT 84
CAP, Valve
KIT 1
VALVE ASSEMBLY
KIT 96,97 RING, Head
KIT 96,97 PACKING
KIT 96
RETAINER, Packing
KIT 96,97 O-RING
KIT 96,97 O-RING
802-345 GAUGE, Sight
BEARING

Kit
No.

Repair Kit
Part No.

Ref
No.

1

801-472
Valve
Assembly

10
11
12
13
14
or
17*

QTY
1
2
1
1
1
1
8
8

1
1

Description

Qty.

O-RING
SEAT, Valve
PLATE, Valve
SPRING
CAGE, Valve

6
6
6
6
6

VALVE ASSEMBLY

6

83

804-033
Oil Seal

5

SEAL, Oil

3

84

804-034
Valve Cap

15
16

O-RING
CAP, Valve

6
6

96

804-036
Packing
Assembly

18
19
20
21
22

RING, Head
PACKING
RETAINER,
Packing
O-RING
O-RING

1
1
1
1
1

97

804-037
Packing

18
19
21
22

RING, Head
PACKING
O-RING
O-RING

3
3
3
3

REF
NO.
25
26
27
28
29
30
31
32
33
34
35
36
37
49
50
51
52
53
54
55
56
57
58
59

PART
NO.
DESCRIPTION
801-659 DIPSTICK
NUT
WASHER
PLUNGER
803-918 O-RING
803-919 RING, Back Up
WASHER, Flinger
PIN, Connecting Rod
COVER, Crankcase
SCREW
804-015 GASKET, Cover
END, Connecting Rod
ROD, Connecting
SCREW
801-652 WASHER
FLANGE
SCREW
WASHER
SPACER
803-268 O-RING
804-018 SEAL, Oil
RING, Snap
BEARING
CRANKSHAFT

* Item 17 consists of items 10 through 14.
See Pump Assembly illustration on previous page.
824–001

QTY
1
3
3
3
3
3
3
3
1
4
1
3
3
4
4
1
4
4
1
1
1
1
1
1

21

Pump Assembly – Parts
Model 804–559
13
14

10
12

19

15

9

16

8

18

7

11

6
5
4
1
2

45

3

44

43

42

44

45

41

40

17

48
46
79

49
47

80

75

11

76

9

83

10

77
78

81

84

82

25

27

28

29
32
34

26

35



24
23
22
33


824–001

31

30

Pump Assembly – Parts
USE ONLY GENUINE GRACO PARTS AND ACCESSORIES
MODEL 804–559
REF
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
22
23
24
25
26
27
28
29

PART
NO.
801-651
801-652
KIT 123
KIT 123
KIT 123
KIT 123
KIT 123
KIT 124
KIT 124
KIT 123

803-268
KIT 23
801-659

801-488

DESCRIPTION
HEAD, Pump
SCREW
WASHER
O-RING
SEAT, Valve
VALVE
SPRING
CAGE, Valve
O-RING
CAP
VALVE ASSEMBLY
SCREW
COVER, Bearing
SPACER
O-RING
BEARING
SEAL, Oil
CRANKCASE
DIPSTICK
GUIDE, Piston
ROD, Connecting
O-RING
COVER, Rear
SCREW
O-RING
SCREW, Cap
PIN

Ref.
No. Description
17
SEAL, Oil

QTY
1
8
8

8
2
1
1
2
1
1
3
3
1
1
5
1
1
3

Kit
No.

Repair Kit
Part No.

23

801-658
Oil Seal

123

804-402
4
Valve Assembly 5
6
7
8
or
11*

O-RING
SEAT, Valve
VALVE
SPRING
CAGE, Valve

6
6
6
6
6

VALVE ASSEMBLY

6

124

804-403
Valve Cap

9
10

O-RING
CAP

6
6

130

804-404
Packing
Assembly

40
41
42
43
44
45

O-RING
RETAINER, Packing
RING, Intermediate
PACKING
PACKING
RING, Head

1
1
1
1
2
2

REF
NO.
30
31
32
33
34
35
40
41
42
43
44
45
46
47
48
49
75
76
77
78
79
80
81
82
83
84

PART
NO.
803-919
803-918
804-415

KIT 130
KIT 130
KIT 130
KIT 130
KIT 130
KIT 130
801-482
801-485

DESCRIPTION
WASHER
RING, Anti-Extrusion
O-RING
PISTON
WASHER
NUT
O-RING
RETAINER, Packing
RING, Intermediate
PACKING
PACKING
RING, Head
SCREW, Cap
SCREW, Cap
WASHER
WASHER
RING, Retaining
CRANKSHAFT
BEARING
O-RING
SCREW
WASHER
FLANGE
SEAL, Oil
WASHER
SCREW

QTY
3
3
3
3
3
3

1
1
1
1
1
1
1
1
4
4
1
1
4
4

Qty.
3

* Item 11 consists of items 4 through 8.
See Pump Assembly illustration on previous page.

824–001

23

The SHERWIN–WILLIAMS Warranty
and Disclaimers
WARRANTY
Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on
the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this
warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation,
misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco
equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor
for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any
defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts,
labor and transportation.
DISCLAIMERS AND LIMITATIONS
The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or
implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non–contractual
liabilities, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase price.
Any action for breach of warranty must be brought within two (2) years of the date of sale.
EQUIPMENT NOT COVERED BY GRACO WARRANTY
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with
respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items sold, but not
manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer.
Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

The SHERWIN–WILLIAMS COMPANY, 101 PROSPECT AVENUE, CLEVELAND, OHIO 44115
PRINTED IN U.S.A.

24

824–001

824–001 January 1996, Revised May 1998



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 1998:05:26 12:56:18Z
Modify Date                     : 2008:10:16 10:17:50-05:00
Metadata Date                   : 2008:10:16 10:17:50-05:00
Producer                        : Acrobat Distiller 2.1 for Windows
Format                          : application/pdf
Document ID                     : uuid:42267d80-89a3-420d-a3b2-d19da3656b31
Instance ID                     : uuid:84f86f8b-ddec-4383-ae38-d570a7b6a79b
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu