Graco 311304J GTP10 Fuel Transfer Pump, Instructions Parts, U.S. English User Manual To The 4537537a 963f 4962 8543 890953b96d5c

User Manual: Graco 311304J to the manual

Open the PDF directly: View PDF PDF.
Page Count: 16

DownloadGraco 311304J GTP10 Fuel Transfer Pump, Instructions-Parts, U.S. English User Manual  To The 4537537a-963f-4962-8543-890953b96d5c
Open PDF In BrowserView PDF
Instructions - Parts List

GTP10 Pump

311304J
EN

For pumping gasoline, diesel fuel, and kerosene. Do not use to pump other fluids including
water.

Models 260000 through 260017, 260019, 260024, 260580, and 260581
10 gpm (38 lpm), 12 VDC (CSA C/US listed motor)
Models 260020 and 260021, 10 gpm (38 lpm), 24 VDC
Models 260022 and 260023, 12 gpm (45 lpm), 230 VAC
Models 260025 through 260028
12 gpm (45 lpm), 115 VAC (CSA C/US listed motor)
10 psi (0.07 MPa, 0.7 bar) Maximum Working Pressure

Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.

CSA mark applies only to 12 VDC
and 115 VAC motors for Class I, Div
I, Group D Hazardous Locations

Models

Models
Part No.

Hose

Nozzle

12 VDC, 10 gpm (38 lpm), 12.5 amps
260000

260069 - 12 ft (3.66 m) grounded

260079 - manual, leaded/diesel

260001

260069 - 12 ft (3.66 m) grounded

260082 - automatic, regular/diesel

260002

260069 - 12 ft (3.66 m) grounded

260078 - manual, unleaded

260003

260083 - automatic, unleaded

260005

260069 - 12 ft (3.66 m) grounded
260526 - 4 ft (1.22 m) UL listed assembly
260523 - 8 ft (2.44 m) UL listed assembly
260525 - 5 ft (1.52 m) UL listed assembly

260006

260525 - 5 ft (1.52 m) UL listed assembly

260078 - manual, unleaded

260007

260524 - 6 ft (1.83 m) UL listed assembly

260078 - manual, unleaded

260008

260524 - 6 ft (1.83 m) UL listed assembly

260078 - manual, unleaded

260009

260525 - 5 ft (1.52 m) UL listed assembly

260078 - manual, unleaded

260010

260522 - 10 ft (3.05 m) UL listed assembly

260078 - manual, unleaded

260011

260525 - 5 ft (1.52 m) UL listed assembly

260078 - manual, unleaded

260012

260523 - 8 ft (2.44 m) UL listed assembly

260078 - manual, unleaded

260013

260525 - 5 ft (1.52 m) UL listed assembly

260078 - manual, unleaded

260014

260525 - 5 ft (1.52 m) UL listed assembly

260078 - manual, unleaded

260015

260078 - manual, unleaded
260078 - manual, unleaded

260017

260523 - 8 ft (2.44 m) UL listed assembly
270521 - 12 ft (3.66 m) UL listed assembly
260525 - 5 ft (1.52 m) UL listed assembly
260525 - 5 ft (1.52 m) UL listed assembly

260019

None

None

260024

None

None

260580

260573 - 12 ft (3.66 m) grounded

260079 - manual, leaded/diesel

260581

260573 - 12 ft (3.66 m) grounded

260082 - automatic, regular/diesel

260004

260016

260078 - manual, unleaded
260078 - manual, unleaded

260078 - manual, unleaded

24 VDC, 10 gpm (38 lpm), 7 amps
260020

260069 - 12 ft (3.66 m) grounded

260079 - manual, leaded/diesel

260021

260069 - 12 ft (3.66 m) grounded

260082 - automatic, regular/diesel

230 VAC, 12 gpm (45 lpm), 1 amps
260022

260069 - 12 ft (3.66 m) grounded

260078 - manual, unleaded

260023

260069 - 12 ft (3.66 m) grounded

260083 - automatic, unleaded

115 VAC, 12 gpm (45 lpm), 2 amps

2

260025

260069 - 12 ft (3.66 m) grounded

260079 - manual, leaded/diesel

260026

260069 - 12 ft (3.66 m) grounded

260082 - automatic, regular/diesel

260027

260069 - 12 ft (3.66 m) grounded

260078 - manual, unleaded

260028

260069 - 12 ft (3.66 m) grounded

260083 - automatic, unleaded

311304J

Models

311304J

3

Warnings

Warnings
The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Additional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual,
refer back to these pages for a description of the specific hazard.

WARNING
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources, such as cigarettes and portable electric lamps.
• Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Ground all equipment in the work area.
• Use only grounded hoses.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
• Keep a fire extinguisher in the work area.
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing
equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and
cause serious injury.
• Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning,
checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

4

311304J

Warnings

WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco
replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your Graco distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.

311304J

5

Installation

Installation

When unpacking pump, check for shipping damage.
Report any shipping damage to delivering carrier immediately.
CAUTION
Do not use a curb pump automatic shut-off nozzle
with this pump. Use of a curb pump automatic nozzle
may cause priming problems, reduced output flow,
and motor overheating. If an automatic shut-off nozzle
is required, use Graco part number 260082 (regular)
or 260083 (unleaded) or Catlow, Inc. part number
NCLF-1 (regular) or NCNLF-1 (unleaded).

FIG. 1

Mounting Pump
•
•

CAUTION
Ensure tank being used is clean and free of welding
slag
Ensure the tank is vented to allow air into the tank
as the fuel is being pumped out. Failure to provide a
vent will cause priming problems

FIG. 2

1. Apply PTFE thread tape (provided with the pump) to
large thread of bung adapter (9) (2 in. X 1 ½ in.
reducer fitting). Install bung adapter to fuel tank.
2. Assemble suction tube sections by applying ¼ in. to
½ in. wide bead of PVC cement (PN: 260086; white
tube provided with the pump) around the entire
inside diameter of the coupler (see FIG. 1). While
sliding the tube into the couplers turn the tube at
least one full revolution until the tube bottoms out on
the coupler (see FIG. 2, FIG. 3, and FIG. 4). This will
allow the cement to coat the entire surface for the
best possible seal. Allow cement to set for 5 minutes minimum before installing pump into tank.

FIG. 3

For tanks deeper than 36 in. (914 mm) you will
need a standard 1 in. (25 mm) pipe with 1 in. npt
threads on one end. Suction tubes longer than 60
in. (1.52 m) require a foot valve (Graco Part No.
260217) at the bottom of the tube to prevent loss of
prime.
FIG. 4

6

311304J

Installation

3. Cut the suction tube so that it is 2 in. (55 mm) from
the bottom of the tank when installed in the tank.
4. Insert gasket (7f) into union nut (1k). If using Graco
supplied PVC suction tube it is not necessary to
apply thread tape before assembly, just screw into
pump inlet (1j). If using metal suction tube (not supplied with pump) then apply thread tape provided
with pump to NPT threads before assembling to
pump inlet (1j).
5. Insert suction tube attached to pump through bung
adapter (9) into tank. Position pump as desired and
tighten union nut (1k) on bung adapter (9).

Mounting Hose and Nozzle
1. Apply thread tape provided with pump to both ends
of hose assembly. Screw ¾” NPT end of 90° union
swivel (15) to one end of hose (see fig. 5).
2. Screw nozzle onto other end of hose and tighten.
3. Start swivel end of 90° union swivel (15) onto ¾”
nipple (14) on pump outlet (see FIG. 5). Orient the
hose/nozzle assembly to desired position and
tighten swivel fitting.
It is important that the swivel end of the 90° union
swivel (15) is assembled to the ¾” outlet nipple (14)
for proper sealing (see FIG. 6). If the pump has difficulty priming, it is easy to remove the swivel and
pour fluid into the pump outlet cavity when assembled this way.

FIG. 5

FIG. 6

311304J

7

Installation

Electrical Installation
12 VDC and 24 VDC

Electrical Installation
115 VAC and 230 VAC

If you are installing models 260580 or 260581 skip
this section. These pumps have been factory wired
To install wiring for a negative ground system:
1. Ensure pump switch is OFF.
2. To remove electrical cover (2a), remove four bolts
(2c).
Power cable can be cut to shorter length if 18 feet
(5.5 m) is not required. Cut to proper length and
proceed with steps 3 and 4.

On 115 VAC and 230 VAC pumps, electrical connections must be made by a licensed electrician per
requirements of local, state, and national codes
regarding class 1, group D installations. Only rigid
conduit with threaded connections or other
approved wiring methods for Class 1 or Division 1
installations should be used. Conduit opening in
pump must be sealed with waterproof, fuel-resistant
sealant. Failure to comply with this warning could
result in injury from electrical shock, fire or explosion.

3. Strip 3 in. (76 mm) of outside insulation from power
cable (6c) from end opposite of fuse.

1. Ensure pump switch is OFF and electrical power is
disconnected.

4. Strip 3/8 in. (10 mm) of insulation from red and black
wires.

2. Install conduit and user-supplied power cord to
pump.

5. Slide strain relief (6b) over end of power cable (6c)
on the end just stripped. Male thread of strain relief
should be toward stripped end.

3. Strip 3 in. (76 mm) from power cord jacket and 1/2
in. (13 mm) from individual conductor insulation.

6. Insert power cable through conduit thread in electrical cover (2a). Connect wires from power cable to
wires from the motor using wire nuts (2e): red to red
and black to black.
7. Screw strain relief (6b) into electrical cover (2a).
8. Position power cable (6c) so the large diameter of
power cable extends through strain relief (6b).
9. Tighten nut on strain relief to form a seal around the
power cable.

4. To remove electrical cover (2a), remove four bolts
(2c).
5. Remove 1/2 in. (13 mm) of insulation from power
wires inside pump electrical terminal cavity.
6. Insert electrical power wire through conduit opening
in back of pump.
7. Using wire nuts (2e), connect wires: green to green,
white to white, and black to black.
8. Replace electrical cover.

10. Reinstall electrical cover (2a) on the pump.
11. Remove 1/2 in. (13 mm) of insulation from wires on
the fuse holder end of the power cable.
12. Attach battery clamps (6a) with red sleeve to red
wire and black sleeve to black wire. Wire must be
crimped to the battery clamp firmly to get a good
electrical connection.
13. Connect red wire with fuse holder inline to positive
battery terminal. Connect black wire to negative battery terminal.

8

311304J

Operation

Priming Pump
All pump models should prime within 5 seconds after
pump is turned on up to a height of 36 in. (91 mm).
Pumps installed at height up to 5 ft. (1.52 m) may have
difficulty priming. Follow procedure below to initiate
prime. Pumps installed at suction height above 5 ft.
(1.52 m) will have difficulty in holding prime. It is recommended that check valve (Graco part no. 260217) be
added to the bottom of the suction tube to help maintain
prime.
If prime in not achieved in 30 seconds after turning the
pump on use the following procedure to initiate prime;
1. Remove 90° Union Swivel (15) from ¾” Inlet Nipple
(14).
2. Pour fluid being pumped into pump outlet until completely filled.
3. Re-assemble Union Swivel (15) back onto nipple
(14). Turn pump on. The pump should gain prime in
under 5 seconds.
4. If pump still does not gain prime check for any major
leaks in the system. If no leaks are found then the
pump is mechanically defective and should be
reported to Graco Product Service for disposition.
It is important that the swivel end of the 90° union
swivel (15) is assembled to the ¾” outlet nipple (14)
for proper sealing (see fig. 6). Also, if the pump has
difficulty priming it is easy to remove the swivel and
pour fluid into the pump outlet cavity when assembled this way.

If prime is lost
1. First make sure there are no fluid leaks from the
pump outlet out to the fuel nozzle. Any leaks after
the outlet will allow air to push the fluid column back
to the tank and prime will be lost.

Operation
Before servicing, turn pump off and open the
nozzle to relieve pressure.

CAUTION
Do not operate pump dry. Do not run pump for more
than 5 minutes with nozzle closed. Do not operate
pump for more than 30 minutes continuously in 1 hour.
On/Off switch lever (8d) is located under nozzle holder.
Remove nozzle before turning pump on.
1. Move switch lever (8d) on.
2. Insert nozzle into tank and actuate nozzle lever to
dispense fuel.
3. Immediately after fueling turn switch lever (8d) off.

Maintenance
1. Clean inlet strainer (3b) after every 50 hours of
operation.
2. To remove inlet strainer (3b), remove four screws
(3c) and strainer cover (3a). Remove and clean
strainer.
3. If strainer is excessively dirty, clean tank to protect
pump and the equipment being fueled.
4. After cleaning strainer, replace strainer and cover.
Make sure cover seal (3d/7e) is in place.

2. If no leaks are detected on the outlet side of the
pump, remove the pump from the tank and inspect
the suction tube and pump inlet for leaks.
3. If the system is leak free and the suction height
guidelines are followed the pumping system should
not lose prime.
All guidelines and procedures are based on pumping diesel fuel. If pumping gasoline priming may be
more difficult due to the lift of gasoline dependent
on Reid's vapor pressure of the gasoline and it's
temperature. The lower the vapor pressure and
temperature, the higher the possible lift.
311304J

9

Troubleshooting

Troubleshooting
Problem
Motor runs but pump will not prime.

Unit pumps but output flow is low.

10

Cause

Solution

Motor rotation wrong. (12 VDC and
24 VDC units only.)

Check wiring instructions for possible
problems.

Missing relief valve o-ring seal
(4c/7a).

Remove gear cover (1b) inspect seal
(4c/7a), replace if missing or
damaged.

Sheared drive key (1f/7c).

Remove cover (1b) and inspect key
(1f/7c/10b), replace if worn or
sheared.

Dirt under relief poppet (4a) or seal
(4c/7a).

Remove cover (1b) and inspect,
clean or replace if damaged.

Strainer seal (3d/7e) leaking.

Inspect and replace if damaged.

Suction height too high to prime.

See Priming Pump, page 9.

Worn or damaged gears.

Remove cover (1b) and inspect
gears. Replace if worn or damaged.

Fuel level low.

Refill tank.

Cover seal (1e7b/10c) damaged.

Replace if worn or damaged.

Inlet strainer (3b) clogged.

Remove and clean or replace.

Air leak in suction tube.

Inspect all joints in suction tube.
Make sure all joints in suction tube
are sealed. and that there are no
cracks from over-tightening

Air lock in system.

This may occur if filter or meter or
automatic shut-off nozzle is used. If
this occurs, fill pump and meter with
fuel through top of pump.

Motor does not run at proper speed.

Check electric connections. Check
supply voltage for proper voltage
level.

Clogged inlet strainer (3b).

Clean or replace.

Air leak in suction tube.

Check to make sure all joints in suction tube are sealed and that there
are no cracks.

Suction tube too close to tank
bottom.

Suction tube must have a 2 in.
(51 mm) minimum clearance.

Tank empty.

Refill tank.

Tank not vented.

Tank must be vented to atmosphere.

Worn or damaged gears.

Remove cover (1b) and inspect
gears. Replace if worn or damaged.

Damaged motor.

Replace motor.

Clogged suction tube, hose, or
nozzle.

Inspect and clean.

311304J

Troubleshooting

Problem
Motor stalls when nozzle is closed.

Fuel leaking in motor mount.

Motor overheating.

Switch will not turn pump on.

311304J

Cause
Bypass relief valve (4a) stuck.

Solution
Inspect relief valve, making sure
poppet is free. Replace if damaged.

Low supply voltage.

Check supply voltage.

Gears (1c/10a) damaged and
binding.

Inspect gears. Gears should turn
freely. Replace if damaged.

Faulty motor.

Replace motor.

Faulty or damaged motor shaft seal
(1g/7d).

Replace shaft seal

Operating pump extended time with
nozzle closed.

Do not exceed 5 minutes of operation
with nozzle closed.

Motor shaft worn.

Replace motor if shaft has groove
worn in seal area.

Gears (1c/10a) binding.

Check to make sure gears turn freely
on shaft.

Operating pump extended time with
nozzle closed.

Do not exceed 5 minutes of operation
with nozzle closed.

Clogged inlet strainer (3b).

Clean or replace, see Maintenance,
page 9.

Clogged suction tube, hose, or
nozzle.

Inspect and clean if required.

Operating pump more than 30 minutes continuous duty.

Limit operation to 30 minutes per
hour.

Blown fuse.

Replace fuse. 20 amp automotive
fuse (Littelfuse ATO 257020 or
Bussman ATC-20).

Electrical problem.

Check that supply voltage is proper
and getting to pump.

Defective switch (8e).

Check and replace if defective.

Mechanical problem.

Check switch actuator cam (8c). Cam
should be actuating the switch (8e).

Damaged or defective motor.

Check motor, replace if damaged or
defective.

11

Parts Drawing

Parts Drawing
Models 260000 through 260017, 260019,
3a
260024, 260580, and 260581, 12 VDC
Models 260020 and 260021, 24 VDC
Models 260022 and 260023, 230 VAC
3b
Models 260025 through 260028, 115 VAC

3c

260456

3d/7e

1h
Packing Kit 260434 includes items 7a-7f
which are also included in other kits.

260458
260459
253723

1b

1e/7b/10c
1f/7c/10b

1c/ 10a
1j

9

4c/ 7a

1d
4b
4a

7f

1k 1g/7d
2g

5c
5a

2c

260457
15

1a

2h

This end to
hose (11)
14

2i

2b
260300

2d

5b

2f

2e
5a

8e
8f
8b

2a
6a

6c

2c

8g
8c

260450
260451
260452
260453
253719
253720
253721
253722
260433
253718

8a

6b
260454

12

8d

311304J

Parts List

Parts List
Models 260000 through 260017, 260019, 260024, 260580, and 260581, 12 VDC
Models 260020 and 260021, 24 VDC
Models 260022 and 260023, 230 VAC
Models 260025 through 260028, 115 VAC
Ref. No.
1
260458
260459
253723
1a
1b
1c (10a)
1d
1e
(7b/10c)
1f
(7c/10b)
1g (7d)
1h
1j
1k
2

260450
260451
260452
260453
253719
253720
253721
253722
2a
2b
2c
2d
2e
2f
2g
2h
2i

311304J

Description
KIT, pump with swivel, blue
(includes items 1a-1k)
KIT, pump without swivel, blue
(includes items 1a-1j)
KIT, pump with swivel, black
(includes items 1a-1k)
BODY, assembly
COVER, gear
GEAR
SHAFT, gear
SEAL, gear cover

Qty
.

1
1
2
2
1

KEY, drive

1

SEAL, shaft
BOLT, hex, 5/16-18 x 3/4 in.
FITTING, inlet
NUT, union (260458 and 253723)

1
4
1
1

KIT, motor, 12 VDC, blue
(includes items 2a-2i)
KIT, motor, 24 VDC, blue
(includes items 2a-2i)
KIT, motor, 115 VAC, blue
(includes items 2a-2i)
KIT, motor, 230 VAC, blue
(includes items 2a-2i)
KIT, motor, 12 VDC, black
(includes items 2a-2i)
KIT, motor, 24 VDC, black
(includes items 2a-2i)
KIT, motor, 115 VAC, black
(includes items 2a-2i)
KIT, motor, 230 VAC, black
(includes items 2a-2i)
COVER, electrical
HOUSING, electrical, 12 V
BOLT, hex, 1/4-20 x 3/4 in.
NUT, 10-32
WIRE NUT, 260450 and 260451
WIRE NUT, 260452 and 260453
FLAG TERMINAL
MOTOR, electric
COVER, nozzle
GUIDE, nozzle

Ref. No.
3
260456
3a
3b
3c
3d (7e)
4

260457
4a
4b
4c (7a)

KIT, popoff (includes items 4a-4c)
POPPET, relief valve
SPRING, relief valve
SEAL, relief valve

1
1
1

5*

260300

KIT, suction, pipe
(includes items 5a-5c)
PIPE, PVC
COUPLER, PVC, female
ADAPTER, PVC, male
CEMENT, PVC (not shown)

2
1
1
1

5a
5b
5c
5d
6** 260454
6a
6b
6c

7

1
1
10
2
2
3
2
1
1
1

Qty
.

Description
KIT, filter, universal
(includes items 3a-3d)
COVER, strainer
SCREEN
SCREW, hex head, 10-24 x 3/8 in.
SEAL, strainer cover

260434
7a (4c)
7b
(1e/10c)
7c
(1f/10b)
7d (1g)
7e (3d)
7f

1
1
1

KIT, cable, 12 V and 24 V only
(includes items 6a-6c)
CLAMP, battery
BLACK SLEEVE
RED SLEEVE
STRAIN RELIEF
ASSEMBLY, power cable,
18 ft (5.5 m), fuse holder, 20 amp
fuse

2
1
1
1
1

KIT, packing (includes items 7a-7f)
SEAL, relief valve
SEAL, gear cover

1
1
1

KEY, drive

1

SEAL, shaft
SEAL, strainer cover
GASKET, inlet

1
1
1

13

Parts List (continued)

Parts List (continued)
Models 260000 through 260017, 260019, and 260024, 12 VDC
Models 260020 and 260021, 24 VDC
Models 260022 and 260023, 230 VAC
Models 260025 through 260028, 115 VAC
Ref. No.
8
260433

8a
8b
8c
8d
8e
8f
8g
260061

ADAPTER, bung

1

KIT, gear (includes 10a-10c)
GEAR
KEY, drive

1
2
1

SEAL, gear, cover

1

253718

9

Qty
.

Description
KIT, switch, blue
(includes items 8a-8g)
KIT, switch, black
(includes items 8a-8g)
COVER, switch
BRACKET, switch
CAM, actuator switch
SWITCH, actuator assy.
SWITCH
SCREW, phillips, 8-32 x 3/8 in.
SCREW, phillips, 6-32 x 1/4 in.

10 260277
10a (1c)
10b
(1f/7c)
10c
(1e/7b)

1
1
1
1
1
2
1

11 see pg. 2 ASSEMBLY, hose, 3/4 in.
(not shown)
12 see pg. 2 ASSEMBLY, nozzle, (not shown)
1315G901
14 15F074
15 156589

LABEL, warning (not shown)
NIPPLE, 3/4 in. x 3/4 in.
ADAPTER, 90° swivel

1
1

 Replacement Danger and Warning labels, tags, and
cards are available at no cost.
* Not used on models 260004, 260006, 260008,
260009, 260010, 260013, 260014, 260015, 260017,
260019, 260024, 260580, and 260581
** Used on 12 VDC and 24 VDC models only

14

311304J

Technical Data

Technical Data
Working pressure
Inlet size
Outlet size
Weight
Power cable
Current draw

10 psi (0.07 MPa, 0.7 bar)
1 in. npt
3/4 in. npt
20 lb (9 kg)
18 ft (5.5 m), 14 AWG (12 VDC and 24 VDC models only)
12 VDC models: 12.5 amps
24 VDC models: 7 amps
115 VAC models: 2 amps
230 VAC models: 1 amps
30 min/hour
1 in. x 34 in. (25.4 mm x 864 mm)
carbon steel with zinc plating, 416 and 302 stainless
steel, fluoroelastomer, Buna-N, Aluminum, Valox®, Nylon,
Nitrile, PVC, Vellumoid,

Duty cycle
Suction tube
Wetted parts

Valox® is a registered trademark of the General Electric Company

/54,%4 02%3352% PSI BAR

-0A

Performance Chart


 

 

 

 

 

 

"
!



 

GPM
LPM
























&,/7 2!4%
0!24 .5-"%23 ,%'%.$
!  6$#  6$#
"  6!#  6!#

311304J

0RESSURE
RELIEF OPENS

15

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 311304

Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2005, Graco Inc. is registered to ISO 9001
www.graco.com
Revised March 2015



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Web Statement                   : 311304 - GTP10 Fuel Transfer Pump
Keywords                        : "MM311304, 311304, 311304J, 311304EN, 311304EN-J, Fuel, pump, PBL, Models,  260000-260017, 260019, 260024, 260580, 260581, 2600020, 260022, 260021, 260022, 260023, 260026-260028, "
Copyright                       : 11/2005, Rev. J, March 2015
Marked                          : True
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Job Ref                         : Z095998
Modify Date                     : 2015:04:22 16:33:33-05:00
Creator Tool                    : FrameMaker 11.0
Create Date                     : 2005:04:27 11:19:54Z
Metadata Date                   : 2015:04:22 16:33:33-05:00
Format                          : application/pdf
Title                           : 311304J  GTP10 Fuel Transfer Pump, Instructions-Parts,  U.S. English
Creator                         : Terri Howard
Description                     : GPT10 Fuel Transfer Pump
Subject                         : MM311304, 311304, 311304J, 311304EN, 311304EN-J, Fuel, pump, PBL, Models,  260000-260017, 260019, 260024, 260580, 260581, 2600020, 260022, 260021, 260022, 260023, 260026-260028,
Document ID                     : uuid:67025b51-279d-48d3-a13c-5b736277f1d7
Instance ID                     : uuid:d379ff3a-403c-4d40-8a91-2b3e55fe9b1e
Page Count                      : 16
Language                        : en
Author                          : Terri Howard
EXIF Metadata provided by EXIF.tools

Navigation menu