Graco 307878Y 50 1 Ratio Fire Ball Lubrication Pump Users Manual 307878Y,

307878Y to the manual be35ab22-30ad-4200-96e6-97241885dc3c

2015-04-02

: Graco Graco-307878Y-50-1-Ratio-Fire-Ball-Lubrication-Pump-Users-Manual-685807 graco-307878y-50-1-ratio-fire-ball-lubrication-pump-users-manual-685807 graco pdf

Open the PDF directly: View PDF PDF.
Page Count: 18

307878Y
EN
Instructions
50:1 Ratio Fire-Ball®
Lubrication Pump
Portable units for heavy grease. For professional use only.
See page 2 for model information, including maximum
working pressure and approvals.
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
These systems are designed to be used only in
pumping non-corrosive and non-abrasive lubricants
and grease. Any other use of the system can cause
unsafe operating conditions and result in component
rupture, fire, or explosion which can cause serious
injury, including fluid injection.
Model 240883 shown
Table of Contents
2307878Y
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Models 225773, 225827, 240883, 240884, and
245695 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Models 225006, 225026, 240880, 240881, and
245696 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Models 222069, 240885, and 245694 . . . . . . . . 7
Models 222245 and 240882 . . . . . . . . . . . . . . . . 7
Models 226012 and 240886 . . . . . . . . . . . . . . . . 8
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . 9
Air Line and Accessories . . . . . . . . . . . . . . . . . 10
Pressure Relief Procedure . . . . . . . . . . . . . . . . 10
Start-up: Single or Multiple Pump Systems . . . 10
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 18
Models
Part No.
Maximum Working
Pressure
psi (MPa, bar)
Size Base Type* Dispense
Kit Cover Inductor Follow
Plate Pail
CE
Installation
Kit 240831
225006
5000 (35, 350)
120 lb Portable  
240880 † 120 lb Portable  
225026 120 lb 2-wheel truck  
245696 120 lb 2-wheel truck  
240881 † 120 lb 2-wheel truck  
222245 120 lb 2-wheel truck  
240882 † 120 lb 2-wheel truck  
225773 35 to 50 lb 2-wheel truck  
245695 35 to 50 lb 2-wheel truck  
240883 † 35 to 50 lb 2-wheel truck  
225827 35 to 50 lb - 
240884 † 35 to 50 lb - 
222069 25 to 50 lb - 
245694 25 to 50 lb - 
240885 † 25 to 50 lb - 
226012 50 lb 2-wheel truck  
240886 † 50 lb 2-wheel truck  
† These models are CE Certified.
Warnings
307878Y 3
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources, such as cigarettes and portable electric lamps.
Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Ground all equipment in the work area.
Use only grounded hoses.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment
until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS from distributor or retailer.
Do not leave the work area while equipment is energized or under pressure.
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
Warnings
4307878Y
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
Do not point dispensing device at anyone or at any part of the body.
Do not put your hand over the fluid outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or
servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses and couplings daily. Replace worn or damaged parts immediately.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
Read MSDSs to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.
WARNING
Installation
307878Y 5
Installation
Grounding
Ground all of this equipment:
Pump: Use a ground wire and clamp as shown in
FIG. 1. Remove the ground screw (Z) and insert
through the eye of the ring terminal at end of ground
wire (Y). Fasten the screw back onto the pump and
tighten securely. Connect the other end of the
ground wire to a true earth ground. To order a
ground wire and clamp, order P/N 222011.
Air and fluid hoses: Use only grounded hoses.
Air compressor: Follow manufacturer’s recommen-
dations.
Fluid supply container: Follow the local code.
To maintain ground continuity when flushing or
relieving pressure, always hold a metal part of the
fun firmly to the side of a grounded metal waste con-
tainer, then trigger the gun.
Models 225773, 225827, 240883,
240884, and 245695
Refer to FIG. 2 for the following instructions.
1. Models 225773, 240883, and 245695 only :
Assemble the truck as shown in the parts drawing
on page 13. Secure the truck pail (5) to the truck
base with the pointed hold-down clamps (3c) and
thumb nuts (3d).
2. Models 225827 and 240884 only : Remove the
fluid outlet adapter included with the pump, and
screw the holster (6) into the pump outlet, using
thread sealant.
3. Remove the cover (4) from the pail of lubricant.
Place the pail of lubricant into the truck pail.
4. Secure the cover (4) on the pail with three thumb-
screws (A).
5. Insert the pump riser tube through the top of the
cover (4). Lower the pump until it rests on the cover.
6. Assembly the gun (2b) and hose (2a), and connect
the hose to the pump fluid outlet.
7. Connect the nipple (2d) to the pump air inlet or air
regulator (7b) inlet, whichever is applicable.
8. Connect the quick-disconnect coupler (2c) to the air
supply hose.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
FIG. 1
Y
Z
FIG. 2
2c,
2d
4
5
3c, 3d
2b
2a
A
7b
Model 240883 shown
6
Installation
6307878Y
Models 225006, 225026, 240880,
240881, and 245696
Refer to FIG. 3 for the following instructions.
1. Models 225006 and 240880 : Assembly the base
(3) as shown in the Parts Drawing on page 14.
Models 225026, 240881, and 245696 : Assemble
the truck (3) as shown in the Parts Drawing on page
13.
2. Remove the fluid outlet adapter included with the
pump, and screw the holster (6) into the pump out-
let, using thread sealant.
3. Place an open 120-lb (54.43 kg) drum of grease on
mounting base or truck and secure it with the
hold-down clamps.
For portable base models 225006 and 240880:
For steel drums use pointed end of bracket (3c).
Position clamps above drum bead. Tight bolts (3b).
For fiber drums reverse bracket (3c) to use flat end.
For truck model 225026, 245696 and 240881:
For steel drums: use pointed end of bracket (3c).
Position clamp above drum bead. Tighten thumb
nuts (3d).
4. Press the follow plate (5) down firmly onto the
grease, and rotate it to eliminate air pockets and
reduce channeling.
5. Insert the pump through the cover (4).
6. Slide the cover up far enough to let the pump pass
easily through the follow plate grommet.
7. Secure the cover (4) on the drum with the thumb
screws (A). It is not necessary to bolt the pump to
the cover.
8. Assemble the gun (2b) and hose (2a), and connect
the hose to the pump fluid outlet.
9. Connect the nipple (2d) to the pump air inlet or air
regulator (7b) inlet, whichever is applicable.
10. Connect the quick-disconnect couple (2c) to the air
supple hose.
FIG. 3
Model 240881 shown
2a
Installation
307878Y 7
Models 222069, 240885, and
245694
Refer to FIG. 4 for the following instructions.
1. Remove the cover from the pail and scoop the lubri-
cant from the center to the sides of the pail to make
its surface concave.
2. Center the follow plate (5) in the pail opening. Press
the plate firmly downward and rotate it over the
lubricant surface to eliminate air pockets and pre-
vent channeling.
3. Place the cover (3a) on thep ail, and tighten the
thumb screws (3f).
4. Assemble the gun (2b) and hose (2a), and connect
the hose to the pump fluid outlet.
5. Connect the nipple (2d) to the pump air inlet or air
regulator (7b) inlet, whichever is applicable.
6. Connect the quick-disconnect coupler (2c) to the air
supply hose.
Models 222245 and 240882
Refer to FIG. 5 for the following instructions.
1. Assemble the cart (6). Use only 2 of the 4 brackets
(5d) supplied.
2. Install the rear positions of the drum shelf (6b).
3. Press the follow plate (4) down firmly onto the
grease, and rotate it to eliminate any air pockets
and reduce channeling. Insert the pump through the
cover (3). Slide the cover up far enough to allow the
pump to pass easily through the follow plate grom-
met and into the grease.
4. Using items 5a to 5d, secure the cover to the drum,
and the drum to the cart. It is not necessary to bolt
the pump to the cover.
5. Assemble the gun (2b) and hose (3a), and connect
the hose to the pump fluid outlet.
6. Connect the quick-disconnect nipple (2d) to the
pump air inlet or air regulator (7b) inlet, whichever is
applicable.
7. Connect the quick-disconnect couple (2c) to the air
supply hose.
FIG. 4
2a
2c,
2d
3f
3a
7b
Model 240885 shown
2b
5
FIG. 5
2b
2c
2d
3
6
4
6b
5a
5b
5c
5d
Model 240882 shown
2a
7b
Installation
8307878Y
Models 226012 and 240886
Refer to FIG. 7 for the following instructions unless other
wise indicated.
1. Assemble the truck as shown in the Parts Drawing
on page 13 but do not assemble the handle.
2. Slide handle through elevator slide tube and secure
handle to base.
3. Remove the fluid outlet adapter included with the
pump, and screw the holster (6) into the pump outlet
using thread sealant.
4. Secure pump to elevator mounting plate.
5. Remove inductor plate locking nut, locking ring, and
o-ring. (FIG. 6)
6. In order, slide inductor plate locking nut, locking
ring, and o-ring on pump riser tube.
7. Adjust the inductor plate (5) on the pump riser tube
so the slots are showing just below the inside of the
plate. Tighten the locking nut securely. (FIG. 6)
8. Open the inductor plate vent by turning the knob
counter clockwise.
9. Place an open 50 lb (22.68 kg) pail of grease on the
truck and secure it with the hold-down clamps.
10. Remove the cover from the pail and scoop the lubri-
cant from the center to the sides of the pail to make
its surface concave.
11. Center the inductor plate (5) in the pail opening.
Press down on the pump and rock it back and forth
to seat the inductor plate to eliminate air pockets.
Continue action until material appears at the vent
opening.
12. Close the inductor plate vent by turning the knob
clockwise.
13. Assemble the gun (2b), Z-swivel, and hose (2a).
14. Connect hose (2a) to holster (6) or to pump fluid
outlet adapter if you chose not to use the hol-
ster.Connect the nipple (2d) to the pump air inlet or
air regulator inlet (7b), whichever is applicable.
15. Connect the quick-disconnect coupler (2c) to the air
supply hose.
FIG. 6
Locking nut
Locking ring
5
1/8” (3 mm)
Pump intake slots
Pump riser tube
FIG. 7
6
3c, 3d
5
2a
2b 2c, 2d
7b
Model 240886 shown
Installation
307878Y 9
Typical Installation
The installation shown below is only a guide for selecting and installing system components and accessories. Con-
tact your Graco distributor for assistance in designing a system to suit your particular needs.
Key:
A Fluid dispense line
B Pump ground wire (required)
C Air regulator
D Main air supply line
EAir filter
F Pump lubricator
G Pump runaway valve
H Bleed-type master air valve (required)
J Quick-disconnect couple and nipple
K Air regulator (7b) with safety valve (7c) and gauge (not
shown)
Included with Models 240880 to 240886
FIG. 8
A
B
ECFGH
J
D
Installation
10 307878Y
Air Line and Accessories
NOTE: Install air line accessories in the order shown in
the Typical Installation.
Install a pump runaway valve (G) to shut off the air
to the pump if the pump accelerates beyond the
pre-adjusted setting. A pump that runs too fast can
be seriously damaged.
Install an air line lubricator (F) for automatic air
motor lubrication.
Install a bleed-type master air valve (H) to relieve air
trapped between the valve and the motor when the
valve is closed.
Install the air regulator (C) to control pump speed
and pressure.
On the main air supply line from the compressor,
install an air line filter (E) to remove harmful dirt and
contaminants from the compressed air supply.
For Models 240880 through 240886, install the
provided air regulator/safety valve (K) at the pump
air inlet with the nipple (7a, also included).
Operation
Pressure Relief Procedure
1. Shut off the air to the pump.
2. Bleed off the air pressure by closing the air regulator
(self-relieving type), or closing the bleed-type mas-
ter air valve installed upstream of the air regulator,
or disconnecting the air supply hose at the
quick-disconnect.
3. Hold a metal part of the gun or valve firmly to the
side of a grounded metal waste container and trig-
ger to relieve fluid pressure.
Start-up: Single or Multiple
Pump Systems
1. Close the air regulator and bleed-type master air
valves to all but one pump.
2. Open the master air valve from the compressor.
3. For the pump which is connected, trigger the dis-
pensing valve into a grounded metal waste con-
tainer, making firm metal-to-metal contact between
the container and valve.
4. Open the bleed-type master air valve, and open the
pump air regulator slowly until the pump is running.
When the pump is primed and all air has been
pushed out of the lines, release the trigger.
5. If you have more than one pump, repeat this proce-
dure for each pump.
NOTE: When the pump is primed, and with sufficient air
supplied, the pump starts when the dispensing valve is
opened and shuts off when it is closed.
Trapped air can cause the air motor to cycle
unexpectedly, causing serious injury if you are
adjusting or repairing the pump. Follow the Pressure
Relief Procedure on page 10.
NOTICE
Avoid hanging air accessories directly on the pump
air inlet. The fittings are not strong enough to support
the accessories and may cause one or more to
break. If accessories must be installed directly on the
pump, provide a bracket on which to mount them.
Installation
307878Y 11
6. Set the air pressure to each pump at the lowest
pressure needed to get the desired results.
NOTE: A pump runaway valve can be installed not he
air line to automatically shut off the pump if it starts to
run too slow.
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself. If the pump accelerates
quickly or is running too fast, stop it immediately and
check the fluid supply. If the supply container is empty
and air has been pumped into the lines, prime the pump
and lines with fluid, or flush it and leave it filled with a
compatible solvent. Be sure to eliminate all air from the
fluid system.
7. Read and follow the instructions supplied with each
component in the system.
8. When shutting off the system, always follow the
Pressure Relief Procedure on page 10.
The maximum working pressure of each pump in
your system may not be the same. To reduce the risk
of over-pressurizing any part of your system, be sure
you know the maximum working pressure rating of
each pump and its connected components. Never
exceed the maximum working pressure of the lowest
rated components connected to a particular pump.
To determine the fluid output pressure using the air
regulator reading, multiply the ratio of the pump by
the air pressure down on the regulator gauge. For
example:
50:(1) ratio x 100 psi air = 50000 psi fluid output
50:(1) ratio x 0.7 MPa air = 35 MPa fluid output
50:(1) ratio x 7 bar air = 350 bar fluid output
Limit the air to the pump so that no air line or fluid line
component or accessory is over pressurized.
Parts
12 307878Y
Parts
Ref No 2, Dispense Kit 222070
Model 225827, 240884: 35 lb to 50 lb pail size
Model 222069, 245694, 240885: 25 lb to 50 lb
pail size
Ref. Part No. Description
Qty
.
2a 109151 HOSE, 1/4 npt (mbe), 12 ft (3.7 m) 1
2b 242056 VALVE 1
2c 114558 COUPLER, quick-disconnect 1
2d 169971 NIPPLE, quick-disconnect 1
2e 202577 Z-SWIVEL 1
Ref. Part No. Description
Qty
.
1 239877 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, See parts list
above
1
3 204134 PAIL 1
4 24N924 COVER, See manual 306345 for
parts, model 225827
1
24R350 COVER, See manual 306345 for
parts, model 240884
1
6 203976 HOLSTER 1
7 240831 CE INSTALLATION KIT, See parts
list on page 16, model 240884
1
Ref. Part No. Description
Qty
.
1 239877 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, see parts above 1
245697 DISPENSE KIT, Model 245694
only, See parts list on page 14
1
3 222059 COVER, includes items 3a- 3h 1
3a 207617 COVER, pail 1
3b 168102 PLATE, stop, pump 1
3c 158048 BUMPER, button, rubber 1
3d 159608 RIVET 1
3e 150868 HOLDER, gun 1
3f 100200 SCREW, thumb 3
3g 100025 NUT, 1/4 npsm thd 1
3h 100579 PIN, cotter, 1/8” x 1” 1
5 220653 FOLLOW PLATE, See manual
306345 for parts, model 240885
1
24F901 FOLLOW PLATE, see manual
306345, models 222069, 245694
1
7 240831 CE INSTALLATION KIT, See parts
list on page 16, model 240885
1
2c 2d
2a
2e
2b
6
1
4
3
7
Model 240884 shown
2
1
5
3f
2
3b
3c
3h
3e
7
Model 240885 shown
3d
3a
Ref No. 2
Parts
307878Y 13
Model 225026, 245696l, 240881: 120 lb drum
size
Model 225773, 245695, 2480883: 35 lb to 50
lb pail size
Ref No. 3, Truck 203650
.
Ref. Part No. Description
Qty
.
1 239887 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, See parts, page 12 1
245697 DISPENSE KIT, Model 245696 only,
See parts, page 14
1
3 203650 TRUCK, 2 wheel, See parts below 1
4 204574 COVER, See manual 30345 for parts,
models 245696, 240881
1
24R350 COVER, See manual 30345 for parts,
model 255026
1
5 220654 FOLLOW PLATE, See manual
306345 for parts, model 245696,
240881
1
220654 FOLLOW PLATE, See manual
306345 for parts, model 255026
1
6 203976 HOLSTER 1
7 240831 CE INSTALLATION KIT, See parts
on page 16, model 240881
1
Ref. Part No. Description Qty
1 239877 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, See parts, page 12 1
245697 DISPENSE KIT, Model 245696 only,
See parts, page 14
1
3 203650 TRUCK, 2 wheel, See parts below 1
4 204574 COVER, See manual 306345 for
parts, models 245695, 240883
1
24F901 COVER, See manual 306345 for
parts, model 225773
1
5 204134 PAIL 1
6 203976 HOLSTER 1
7 240831 CE INSTALLATION KIT, See part list
on page 16, models 240883
1
Ref. Part No. Description
Qty
.
3a 203651 BASE, truck, bare 1
3b 101251 WHEEL 2
3c 159912 NUT, thumb, 5/16-18 2
3d 159913 CLAMP, hold down, steel drums
only
2
3e 154636 WASHER, 5/8”, 16 GA 4
3f 100609 SCREW, rd nd mach, 1/4-20 x 3/8” 2
3g 101242 RING, retaining 2
3h 159924 HANDLE, truck 1
4
2
3
7
Model 240881 shown
5
6
1
1
6
4
5
7
Model 240883 shown
2
3
3h
3g
3e
3b
3f
3e
3c
3d
3a
Ref No. 3
Parts
14 307878Y
Model 225006, 240880: 120 lb drum size
Ref No. 3, Portable Base 203622, Series B
Ref No. 2, Dispense Kit 245697
Ref. Part No. Description Qty.
1 239887 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, See parts, page 12 1
3 203622 PORTABLE BASE, See parts list
below
1
4 204574 COVER, See manual 306345 for
parts, model 240880
1
24R350 COVER, See manual 306345 for
parts, model 225006
1
5 220654 FOLLOW PLATE, See manual
306345 for parts, model 240880
1
5 24F902 FOLLOW PLATE, See manual
306345 for parts, model 225006
1
6 203976 HOLSTER 1
7 240831 CE INSTALLATION KIT, See parts
on page 16, model 240880
1
Ref. Part No. Description
Qty
.
3a 191750 BASE, drum 1
3b 102547 BOLT, hex hd, 5/16”-18 x 1.5” 2
3c 191747 BRACKET 2
3d 100214 WASHER, lock 2
3e 100132 WASHER, flat 2
3f 113660 RIVET 16
3g 113646 CASTER, polyurethane 4
Ref Part No. Description
Qty
.
2a 109151 HOSE, 1/4 npt(mbe), 12 ft (3.7 m) 1
2b 233807 VALVE 1
2c 114558 COUPLER, quick-disconnect 1
2d 169971 NIPPLE, quick-disconnect 1
2e 202577 Z-SWIVEL 1
2
Mode
l 240880 shown
1
7
4
6
5
3
3a
3b
3c
3e
3d
3f
3g
2c
2d
2a
2e
2b
Ref No. 2
Ref No. 3
Parts
307878Y 15
Ref No. 2, Dispense Kit 222838
Model 222245, 240882: 120 lb drum size
Ref Part No. Description Qty
2a 109154 HOSE 1
2b 242056 VALVE 1
2c 114558 COUPLER, quick-disconnect 1
2d 169971 NIPPLE, quick-disconnect 1
2e 202577 Z-SWIVEL 1
Ref Part No. Description
Qty
.
1 239887 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222383 DISPENSE KIT, See parts list
above
1
3 222060 COVER, See manual 306345 for
parts
1
4 220654 FOLLOW PLATE, See manual
306345 for parts, model 240882
1
24F902 FOLLOW PLATE, See manual
306345 for parts, model 222245
1
5 222061 HOLD DOWN KIT, Includes items
5a to 5d
1
5a 200889 NUT, wing 2
5b 153166 HOOK, drum mounting 2
5c 153102 ROD, drum 2
5d 159016 BRACKET, retaining (2 used) 4
6 222243 CART KIT, includes items 6a to 6p 1
6a 218027 FRAME, cart 2
6b 183987 SHELF, drum 1
6c 107144 SCREW, cap, 3/8-16 x2-1/4 4
6d 179766 HANDLE, cart 1
6e 100731 WASHER, flat, 3/8 6
6f 101566 LOCKNUT, hex, 3/8-16 6
6g 179770 AXLE 1
6h 154628 WASHER, flat, 3/4 4
6j 107146 RING, retaining, ext, 3/4 4
6k 106039 WHEEL, tire, pneumatic 2
6m 107145 CAP, tube 2
6n 100680 CAPSCREW, 3/8-16 x 7/8 2
6p 159016 BRACKET, retaining 2
7 240831 CE INSTALLATION KIT,
See part list on page 16, model
240882
1
2c
2d
2a
2e
2b
2
3
6g
4
6b
5a
5b
5c
5d
6c
6e
6d
6m
6f
6j
6a
6h
6n
6p 6e 6f 6k 6h 6j
1
7
Ref No. 2
Parts
16 307878Y
Model 226012, 240886: 50 lb pail size
Ref No. 7, CE Installation Kit 240831
Ref. Part No. Description Qty.
1 239877 PUMP, 50:1 Fire-Ball, See manual
308883 for parts
1
2 222070 DISPENSE KIT, See parts, page
12
1
3 203650 TRUCK, portable, See parts list on
page 13
1
4 203664 ELEVATOR 1
5 204351 FOLLOW PLATE 1
6 203976 HOLSTER 1
7 240831 CE INSTALLATION KIT, See parts
list below, model 240886
1
Ref. Part No. Description Qty.
7a 156849 NIPPLE 1
7b 109075 REGULATOR, air, with gauge 1
7c 103347 VALVE, safety 1
7d 222011 CLAMPING, grounding 1
7e CE Label 1
ATTENTION: To comply with CE directives, the CE
identification label must be affixed to the back of the
cart or to the top of the drum cover. Permanently
mark the date of the assembly on the label.
1
3
4
5
6
7
Model
240886 shown
2
7a
7b
7d
7e
7c
Ref No. 7
Technical Data
307878Y 17
Technical Data
.
50:1 Ratio Fire-Ball Lubrication Pumps
US Metric
Maximum fluid working pressure 5000 psi 35 MPa, 350 bar
Maximum Air Inlet Pressure 100 psi 0.7 MPa, 7 bar
Sound (dBa)
Tested at 100 psi (0.7 MPa, 7 bar) at 40 cycles per minute
Sound Pressure Level, measured at 1
meter from unit
77.9 dB(A)
Sound Power Level, tested in accordance
with ISO 9614-2
85.6 dB(A)
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original instructions. This manual contains English. MM 307878
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 1988, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revised May 2014
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590