Graco 311882T T2 2 1 Ratio Transfer Pump Users Manual
295616 a81d6120-7c85-469f-9645-14b0127cbd44 Graco Marine Sanitation System 295616 User Guide |
2015-04-02
: Graco Graco-311882T-T2-2-1-Ratio-Transfer-Pump-Users-Manual-686350 graco-311882t-t2-2-1-ratio-transfer-pump-users-manual-686350 graco pdf
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
Instructions T2 2:1 Ratio Transfer Pump 311882T EN For use with polyurethane foam, polyurea, and similar non-flammable materials. For professional use only. Not for use in explosive atmospheres. Model 295616 (55-gallon drum) 180 psi (1.2 MPa, 12 bar) Maximum Air Working Pressure 405 psi (2.7 MPa, 27 bar) Maximum Fluid Working Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. WLD Warnings Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Moisture Sensitivity of Isocyanates . . . . . . . . . . . . 4 Isocyanate Hazard . . . . . . . . . . . . . . . . . . . . . . . 4 Foam Self-Ignition . . . . . . . . . . . . . . . . . . . . . . . . 4 Keep Components A and B Separate . . . . . . . . . 4 Changing Materials . . . . . . . . . . . . . . . . . . . . . . . 4 Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . 5 Typical Installation, without Circulation . . . . . . . . 5 Typical Installation, with Circulation . . . . . . . . . . 6 Typical Installation for Lubrication Applications . 7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 System Accessories . . . . . . . . . . . . . . . . . . . . . . 8 Air Line Accessories . . . . . . . . . . . . . . . . . . . . . . 8 Fluid Line Accessories . . . . . . . . . . . . . . . . . . . . 8 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Grounding the System . . . . . . . . . . . . . . . . . . . 10 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Pressure Relief Procedure . . . . . . . . . . . . . . . . 11 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Daily Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Daily Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . 11 Air Motor Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pump Lower Repair . . . . . . . . . . . . . . . . . . . . . . . . 14 Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Parts - Model 295616 . . . . . . . . . . . . . . . . . . . . . . . 18 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Performance Chart . . . . . . . . . . . . . . . . . . . . . . 23 Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 24 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 24 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear impervious gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection 2 311882T Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. 311882T 3 Moisture Sensitivity of Isocyanates Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts. Isocyanate Hazard Read material manufacturer’s warnings and material MSDS to know the specific hazards of isocyanates. Use equipment in a well-ventilated area. Wear respirator, gloves, and protective clothing when using isocyanates. The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature. To prevent exposing ISO to moisture: • • • • • Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container. Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system. Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use. Never use solvent on one side if it has been contaminated from the other side. Always lubricate threaded parts with Part 217374 ISO pump oil or grease when reassembling. Foam Self-Ignition Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and material MSDS. Keep Components A and B Separate CAUTION To prevent cross-contamination of the equipment’s wetted parts, never interchange component A and component B. Changing Materials • • • • 4 When changing materials, flush the equipment multiple times to ensure it is thoroughly clean. Check with your material manufacturer for chemical compatibility. Some materials use catalyst on the A side, but some applications may use catalyst on the B side. Epoxies often have amines on the B (catalyst) side. Polyurethanes often have amines on the B (resin) side. 311882T Typical Installation Typical Installation Typical Installation, without Circulation Key for FIG. 1 A B C D E F G Reactor Proportioner Heated Hose Fluid Temperature Sensor (FTS) Heated Whip Hose Fusion Spray Gun Proportioner and Gun Air Supply Hose Feed Pump Air Supply Lines (3/8 in. (76 mm) ID min. H J K L M N P Waste Containers Fluid Supply Lines (217382) Feed Pumps Agitator Desiccant Dryer Bleed Lines/Over Pressure Relief Gun Fluid Manifold G K M K A N F J D E L H P C* B ti11572a * Shown exposed for clarity. Wrap with tape during operation. FIG. 1: Typical Installation, without Circulation 311882T 5 Typical Installation Typical Installation, with Circulation Key for FIG. 2 A B C D E F Reactor Proportioner Heated Hose Fluid Temperature Sensor (FTS) Heated Whip Hose Fusion Spray Gun Proportioner and Gun Air Supply Hose G J K L M N P Feed Pump Air Supply Lines (3/8 in. (76 mm) ID min) Fluid Supply Lines Feed Pumps Agitator Desiccant Dryer Recirculation/Over Pressure Relief Return Hoses Gun Fluid Manifold G K M M K A N F J D E L N P C* B ti11571a * Shown exposed for clarity. Wrap with tape during operation. FIG. 2: Typical Installation, with Circulation 6 311882T Typical Installation Typical Installation for Lubrication Applications Key for FIG. 3 A B C D E F Pump Air Regulator Air Line Lubricator Air Line Filter Bleed-Type Master Air Valve (required, for pump) Fluid Drain Valve (required) Bung Adapter G H J K L Grounded Air Hose Grounded Fluid Hose Pump Fluid Inlet 1/4 npt(f) Pump Air Inlet 3/4 npt(f) Pump Fluid Outlet D C A D B K F L G H E J J 01349 FIG. 3: Typical Installation for Lubrication Applications 311882T 7 Installation Installation Fluid Line Accessories A bleed-type master air valve (D) and a fluid drain valve (E) are required in your system, to help reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, and injury from moving parts when you are adjusting or repairing the pump. A fluid drain valve (E) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING on left). Install the drain valve so that it points down and the handle points up when the valve is opened. The bleed-type master air valve (D) relieves air trapped between this valve and the pump after the pump is shut off. Trapped air can cause the pump to cycle unexpectedly and result in serious injury, including amputation. Install the valve close to the pump. The fluid drain valve (E) helps relieve pressure in the displacement pump, hose, and dispensing valve when shutting off the pump. Actuating the dispensing valve to relieve pressure may not be sufficient, especially if there is a clog in the hose or the dispensing valve. System Accessories To ensure maximum pump performance, be sure that all accessories used are properly sized to meet your system’s requirements. See Accessories, page 20. Air Line Accessories Install the following accessories in the order shown in the Typical Installation for Lubrication Applications, using adapters as necessary: An air line lubricator (B) provides automatic air motor lubrication. A bleed-type master air valve (D) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING on left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator. An air line filter (C) to remove harmful dirt and moisture from the compressed air supply. A second bleed-type air valve (D) isolates the air line accessories for servicing. Locate upstream from all other air line accessories. 8 311882T Setup Setup 1. Apply thread sealant to the male threads of the air needle valve (48) and the quick disconnect fitting (49) and install. See FIG. 4 1 3. Use labels (70) provided to identify the appropriate pump for your material. See FIG. 5. Apply thread sealant 1 48 FIG. 6 1 49 WLD FIG. 4 2. Apply thread sealant to the male outlet fitting (not supplied) and insert into the outlet port. See FIG. 5. 1 4. Lubricate the bung adapter inside diameter and mounting threads. Ensure the gasket is in place and screw the bung adapter (51) securely into the bunghole of the drum. Insert the pump through the adapter and lock it in place. See FIG. 7. 2 Lubricate threads Apply thread sealant 1 51 1 2 FIG. 7 FIG. 5 311882T 9 Setup 5. Install air line (3/8 in. (76 mm) ID minimum) with quick disconnect air coupler (52) provided. See FIG. 8. 1. Pump: Connect Ground Wire (Y) to grounding screw (72) and tighten the screw securely. See FIG. 9. Connect the other end of the wire to a true earth ground. Make certain to comply with all National, State, and Local Electrical Codes. Y 72 52 WLD FIG. 9 FIG. 8 Grounding the System To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. 2. Air compressor: according to manufacturer’s recommendations. 3. Fluid hoses: use only grounded hoses with a maximum of 300 ft (91 m) combined hose length to ensure grounding continuity. Refer to Hose Grounding Continuity. 4. Dispensing valve: grounding is obtained through connection to a properly grounded fluid hose and pump. 5. Object being sprayed: according to local code. 6. Fluid supply container: according to local code. 7. All solvent pails used when flushing, according to local code. Use only metal pails, which are conductive. Do not place the pail on a non–conductive surface, such as paper or cardboard, which interrupts the grounding continuity. 8. To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the spray gun/dispensing valve firmly to the side of a grounded metal pail, then trigger the gun/valve. 10 311882T Operation Operation Pressure Relief Procedure 1. Follow Pressure Relief Procedure, page 11. 2. Place suction tube in grounded metal drum containing cleaning fluid. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. 1. Engage trigger lock. 2. Close the bleed-type master air valve. 3. Set pump to lowest possible fluid pressure, and start pump. 4. Hold a metal part of the dispense valve firmly to a grounded metal pail. Trigger the dispense valve until clean solvent dispenses. 5. Remove valve from hose. 3. Disengage the trigger lock. 6. Follow Pressure Relief Procedure, and remove fluid filter and soak in solvent. Replace filter cap. 4. Hold a metal part of the dispense valve firmly to a grounded metal pail. Trigger the valve to relieve pressure. Daily Startup 5. Engage the trigger lock. 6. Open all fluid drain valves in the system, having a waste container ready to catch drainage. Leave drain valve(s) open until you are ready to dispense again. 7. If you suspect the nozzle or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen the hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or nozzle obstruction. Flushing Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. 1. Verify that the air needle valve is closed. 2. Connect the air line quick disconnect coupler to the transfer pump 3. Turn on the main air supply. 4. Slowly open the air needle valve until the transfer pump runs slowly. 5. Use the air needle valve to control the pump speed. Caution Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed and could cause personal injury and/or damage to the pump. If the pump accelerates quickly or starts running too fast, stop it immediately and check the fluid supply. If the supply container is empty or air has been pumped into the lines, refill the container and prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system. Do not attempt to operate pump unless it is securely mounted in a drum. • • Flush at the lowest pressure possible. Check connectors for leaks and tighten as necessary. Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted parts. Daily Shutdown 1. Disconnect air line coupler. 2. When air pressure is bled off, close the air line needle valve. 311882T 11 Air Motor Repair Air Motor Repair CAUTION Air valve assembly has changed to series B for improved performance. Parts are not interchangeable between series A and B air motor. Series A air valves can be upgraded to series B with kit 262042. 2. Series A air motors only: Loosen set screw (18) and unscrew air valve (5). If necessary to assist turning, wedge a screwdriver blade between the screw heads and the hex cap of air valve (5). Discard items 5, 13, 15, and 18. See FIG. 11. *15 1. Remove cap (1), cylinder (4), and square gaskets (3*). Inspect all parts, including spring under cap (not shown in FIG. 10) for damage and replace if necessary. See FIG. 10. Unscrew by hand or use a chain wrench to prevent distortion of the cylinder’s shape. 5 *13 18 1 *3 FIG. 11: Series A Air Valve 4 *3 WLD FIG. 10 3. Series B (and later Air Motors): Unscrew air valve (5). If necessary to assist turning, wedge a screwdriver blade between the screw heads and the hex cap of the air valve (5). Inspect o-rings (13* and 15*) for damage and replace if necessary. Ensure o-ring (13*) is correctly positioned and not pinched. See FIG. 12. *15 NOTE: Cap (1) was replaced with a spring stop assembly for improved spring life. Existing pumps can be upgraded with Kit 24T043. NOTE: Series A air motors have thin, flat, white seals in air valve. Series B (and later) air motors have thicker black seals in the air valve. 5 *13 WLD FIG. 12 Series B Air Valve 12 311882T Air Motor Repair 4. Align slot of shield (75) with piston hole and place pin tool (69) in piston hole to prevent piston from turning. Use second pin tool (69) to unscrew piston cap (17) and separate from piston (21) to expose dowel pin (19). See FIG. 13. 6. Slide air piston (21) out the top of the air motor base (23). Remove o-ring (24*) from air motor base. Inspect all parts, including the spring (22) in the air motor base, for damage. See FIG. 15. 17 21 69 21 *24 69 22 75 23 WLD FIG. 15 WLD FIG. 13 5. Remove dowel pin (19) and take piston cap (17) off transfer shaft (20). Remove o-ring (50*) from piston cap. Inspect all parts for damage. See FIG. 14. 17 19 *50 20 WLD FIG. 14 311882T 13 Pump Lower Repair Pump Lower Repair 1. Use a chain wrench near the top of the suction tube at the point indicated in FIG. 16, and a wrench on the flats of the foot valve (45) to loosen the foot valve from the suction tube (44). To prevent damage to the suction tube, do not remove the foot valve until instructed to do so in step 3. 2. With the foot valve still in place to support the suction tube, use a chain wrench near the bottom of the suction tube at the point indicated in FIG. 17, to loosen the suction tube (44) from the pump body (34). 3. Remove the foot valve assembly from the suction tube (44). 4. Remove retaining ring (46), snap ring (47), ball (71), and o-ring (38*) from foot valve (45). Inspect all parts for damage. See FIG. 17. Apply chain wrench approximately here 5. Remove suction tube (44) from pump body (34). See FIG. 18. 44 6. Inspect o-ring (38) on pump body and suction tube for damage. See FIG. 18. 38 34 Apply chain wrench approximately here FIG. 16 NOTE: When removing the suction tube, be very careful not to bend, dent, or damage it. To avoid damage, use the chain wrench only at the top and bottom of the suction tube as indicated in FIG. 16 and FIG. 17. Do not apply the wrench to the middle of the suction tube. 44 ti9976 FIG. 18 44 46 47 71 *38 45 Apply chain wrench approximately here ti9903 FIG. 17 14 311882T Pump Lower Repair 7. Pull transfer shaft (20) out the bottom of pump body (34). See FIG. 19. 9. Remove pins (55). See FIG. 21. 55 36 35 54 34 74 55 20 r_311880_14e_fig21 FIG. 21 NOTE: Series A and B pumps were equipped with springs pins. In Series C pumps, these pins were replaced with a solid clevis pin (55, 56). ti9905 FIG. 19 8. Remove pin (56). Remove piston valve assembly. Unscrew piston valve (43) from piston housing (53). Remove wear ring (41*), u-cup (40*) and ball (42). Inspect all parts for damage. See FIG. 20. 10. Loosen set screw (37) from collar (36). Remove collar from piston housing (54). Remove u-cup (35*). Inspect all parts for damage. See FIG. 22. 36 *35 Lip down 53 37 56 *40 Lip up 54 *41 42 r_311882_14e_fig22 43 ti9904b FIG. 20 311882T FIG. 22 15 Pump Lower Repair 11. Unscrew mounting flange (26) from pump body (34). Remove o-ring (32*) and PTFE gasket (33*) from pump body (34). Inspect all parts for damage. See FIG. 23. 13. Unscrew three fasteners (60) to remove the flange (26) and tie-rods (25). Slide the guard (75) out. Unscrew the tie rods (25) using the wrench flats at the bottom. NOTE: Align a bottom slot of the shield (75) and use pin tool (69) to loosen the hex nut/packings from the pump shaft. 25 34 26 75 *32 26 *33 WLD 60 FIG. 23 WLD FIG. 24 12. Remove hex nut (27) from mounting flange (26). Remove female gland (30*), 2 PTFE packings (29*), male gland (28*) and wiper (31*). Inspect all parts for damage. See FIG. 25. 27 75 *30 *29 69 *28 *31 WLD Seal stack enlarged to show detail. FIG. 25 16 311882T Reassembly Reassembly NOTE: See Air Motor Repair, step 3 and step 4 (FIG. 12) for special notes on reassembly. To reassemble the pump lower and air motor, reverse the steps on the preceding pages. Follow the torque requirements listed in the Parts - Model 295616 drawing on page 18. Troubleshooting Problem The pump fails to operate Cause Solution Dirty or worn air motor. Clean, service Inadequate air supply or restricted lines. Clean lines or increase the air supply (see Technical Data). Closed or clogged air valves. Open or clear the valves. Clogged fluid hose or valve. Clear the hose or valves Worn or damaged valves or seals. Service the valves or seals. The pump operates, but the output is Clogged fluid hose or valve. low on both strokes. Exhausted fluid supply. Worn or damaged valves or seals. Clear the hose or valves. Refill the fluid supply and reprime the pump. Service the valves or seals. The pump operates, but the output is Held open or worn intake valve. low on the downstroke. Worn or damaged valves or seals. Clear or service the valve. The pump operates, but the output is Held open or worn piston valve. low on the upstroke. Worn or damaged valves or seals. Clear or service the valve. Erratic or accelerated operation. Refill the fluid supply and reprime the pump. Exhausted fluid supply. Service the valves or seals. Service the valves or seals. Broken air motor compression spring. Replace the spring. Pump slowly moves after fluid shutoff Clogged or dirty intake valve check in downstroke. ball. Worn or damaged valves or seats. Pump slowly moves after fluid shutoff Clogged or dirty lower piston ball or in upstroke. seat. Worn or damaged valves or seats. 311882T Clean ball and seat. Install repair kit. Clean ball and seat. Install repair kit. 17 Parts - Model 295616 Parts - Model 295616 21 1 4 74❄ 8 76 56✓ 77 *3 22 53 2 40✓ 34 41✓ 23 8 42✓ 4 24* 43 2 44 5 3* 25 6 5d 5e 38✓ 73✓ 5a* 5c 4 ✿5 75 39 5b* 3 5h* 27 *30 5f 9 46 7 47 *29 *28 36 31* 5g 37 ❄20 71 35✓ 38✓ 5j* 72 ✿19 17✿ 60 26 ❄55 ❄54 45 5 4 6 WLE *✿50 1 *32 51c *33 ✓51h Lubricate all o-rings and seals before and after assembly 51 Bung Adapter 2 Torque to 45-55 ft-lbs (61-74.5 N•m) 3 Torque to 30-40 ft-lbs (40.6-54.2 N•m) 4 Torque to 15-20 ft-lbs (20.3-27.1 N•m) 51b 5 Torque to 10-12 ft-lbs (13.5-16.3 N•m) ✓51a 6 Torque to 110-120 in-lbs (12.3-13.4 N•m) 7 Torque to 20-30 in-lbs (2.2-3.3 N•m) 8 Torque to 50-60 in-lbs (5.6-6.7 N•m) 9 Tighten 1/8 to 1/4 turn past finger-tight 18 311882T Parts - Model 295616 Ref 1‡ 2‡ 3‡* 4 5✿ 5a* 5b* 5c 5d 5e 5f 5g 5h* 5j* 17✿ 19✿ 20❄ 21 22 23 24* 25 26 27 28* 29* 30* 31* 32* 33* 34 35✓ 36 37 Part 16V524 157630 120212 24J528 262035 15J539 121889 15J544 121610 16U730 15V554 15J546 160258 722834 38✓★ 39 40✓ 41✓ 42✓ 43 44 45 46 47 48† 49† 50*✿ 51 106258 24J534 15J565 15J566 103462 24J531 24J532 24J533 120734 120735 206264 169969 108832 253146 51a✓ 51b 51c 51h✓ 52† 53 54❄ 55✓❄ 120998 24J526 234188 120207 114558 15J570 15J548 24J535 15J551 24J529 159846 15J553 24J530 15J555 15J556 15J557 15J558 15J559 15C638 15J560 24J536 15J562 15J563 101194 120294 311882T Description CAP, air cylinder SPRING, tapered PACKING, square CYLINDER, air motor VALVE, air GASKET, upper O-RING SPACER SCREW CAP, air, valve HEAD, air valve DISK, air valve O-RING O-RING CAP, air piston PIN, dowel SHAFT, transfer PISTON, air SPRING, compression BASE, air motor O-RING (green) ROD, tie FLANGE, mounting NUT, hex GLAND, packing, (male) V-PACKING, PTFE GLAND, packing, (female) WIPER, ROD O-RING, PTFE, encapsulated GASKET, PTFE BODY, pump, 2:1 PACKING, piston cup COLLAR, retaining SCREW, set, socket head, 10-32 x .25 in. (6 mm) O-RING CYLINDER, fluid PACKING, u-cup, PTFE RING, wear BALL, outlet, sst, 3/4 in. (19 mm) VALVE, piston TUBE, suction VALVE RING, retaining, internal RING, snap, e series VALVE, needle FITTING, air line O-RING ADAPTER, bung (includes 51a-51g) O-RING, fluoroelastomer ADAPTER CLAMP, hopper O-RING; inner (brown) COUPLER, air line HOUSING, piston PISTON, upper PIN, clevis, 3/16 in. x 3/4 in. Qty 1 1 2 1 1 1 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 2 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Ref 56✓ 60 69† 70† 71✓ 72 73✓ 74❄ 75 76‡ 77‡ * Part Description 120295 PIN, clevis, 3/16 in. x 1-1/4 in. 120348 SCREW, cap, socket head 1/4-20 x 1 in. (25 mm) 15H197 TOOL, pin 15K008 LABEL, material identification. 107167 BALL, intake, sst, 1 in. (25 mm) 116343 SCREW, ground 113944 O-RING SHAFT, transfer, lower 24V858 GUARD 111819 O-RING 16V523 PIN, spring stop Qty 1 3 2 1 1 1 1 1 1 1 1 Parts included in Upper Seal Repair Kit 262034 (not sold separately). ✓ Parts included in Lower Seal Repair Kit 247883. NOTE: Seal Repair Kit 24X056 includes all parts in kit 262034 and kit 247883. The spring pins (55, 56) originally supplied in series A and B pumps have been upgraded to a solid clevis pin for improved reliability. ❄ Parts included in repair kit 256560 NOTE: The pump shaft originally supplied in series A pumps has been upgraded to a multi-piece assembly for better sealing and serviceability. Pumps can be upgraded with repair kit 256560. ✿ Parts included in repair kit 262042 NOTE: The air valve originally supplied in series A pumps can be upgraded with kit 262042. † Indicates parts not shown, 48, 49, 52, 69, 70 (shipped loose) ★ O-rings included in Tube Extension Kit 24N451. ‡ Parts included in air cap 24T043 NOTE: The cylinder cap has been upgraded with spring stop for improved reliability. Existing pumps can be upgraded with Kit 24T043. NOTE: The T2 can be adapted for use in 250 gallon (946 liter) totes. Tube Extension 24N451 increases the length by 6.25 in. (165 mm) to reach material in the bottom of larger totes. 1 1 1 1 1 1 1 2 19 Accessories Accessories Grounding Clamp Part Description 103538 CLAMP, ground Air Line Lubricator Qty . 1 250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure Part Description 214848 LUBRICATOR, air line; 8 oz (0.24 liter) bowl capacity; 1/2 npt(f) inlet and outlet Qty . 1 Bleed-Type Master Air Valve 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure Part Description 107142 VALVE, ball, vented; 1/2 npt(m) inlet x 1/2 npt(f) outlet Air Line Filter and Regulator Qty . 1 180 psi (1.3 MPa, 13 bar) Maximum Working Pressure Part Description 202660 FILTER, air; includes gauge and two 1/4 npt(m) outlet valves, 50 micron filter element with 100 mesh inlet strainer; 1/2 npt(f) inlet; flow rate is over 50 scfm (1.4 m3/min). Air Line Filter Qty . 1 250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure Part Description 106149 FILTER, air line; 1/2 npt(f) inlet and outlet 20 Qty . 1 01355 311882T Accessories Air Regulator and Gauge Fluid Drain Valve 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure 500 psi (3.5 MPa, 35 bar) Maximum Working Pressure Part Description 202156 REGULATOR, air; 0-200 psi (0-14 bar) regulated pressure range; 3/8 npt(f) inlet and outlet 311882T Qty . 1 Part Description 208630 VALVE, ball; 1/2 npt(m) x 3/8 npt(f); for non-corrosive fluids; carbon steel and PTFE 237534 VALVE, ball; 3/8 npt(m) x 3/8 npt(f); for corrosive fluids; SST and PTFE Qty . 1 1 21 Technical Data Technical Data T2 2:1 Ratio Transfer Pump US Pressure Ratio Max fluid working pressure Maximum Air inlet pressure Max Output Flow (continuous) Metric 2.25:1 2.8 MPa, 28 bar 1.2 MPa, 12 bar 20 lpm 405 psi 180 psi Max Output Flow (intermittent Pump cycles per 1 gallon (3.8 liters) Maximum recommended pump speed for continuous operation Gallons (liters) per pump cycle Air consumption Maximum Ambient temperature Maximum Fluid Temperature Wetted parts Air Inlet Port Fluid Outlet Port Weight Sound Pressure Sound Power, per ISO 9614-2 5.0 GPM 7.5 GPM 28 lpm 15.9 100 cycles per min (150 cycles per min intermittent) 0.063 gal. 0.24 l See performance chart 120° F 50° C 190° F 88° C Stainless Steel, PTFE 1/4 npt(f) 3/4 npt(f) 21.0 lb 9.5 kg 88.7 dB(A) at 80 psi (.55 MPa, 5.5 bar) 96.8 dB(A) at 80 psi (.55 MPa, 5.5 bar) Dimensions 1/4 npt inlet 3/4 npt outlet 54 in. (137.2 cm) 33.7 in. (85.6 cm) WLD 22 311882T Technical Data Performance Chart Calculate Fluid Outlet Pressure (black curves) Calculate Pump Air Consumption (gray curves) To calculate fluid outlet pressure (MPa/bar/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (MPa/bar/psi), use the following instructions and pump data chart. To calculate pump air consumption (m3/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (MPa/bar/psi), use the following instructions and pump data chart. 1. Locate desired fluid flow along bottom of chart. 1. Locate desired fluid flow along bottom of chart. 2. Follow vertical line up to intersection with selected air pressure curve (black). Follow horizontally left to read fluid outlet pressure. 2. Follow vertical line up to intersection with selected air pressure curve (gray). Follow horizontally right to read air consumption. Key: Air Pressure Outlet Pressure in PSI (MPa, bar) 180 psi (1.2 MPa, 12.4 bar) 100 psi (0.7 MPa, 7 bar) 70 psi (0.5 MPa, 4.8 bar) 40 psi (0.3 MPa, 2.8 bar) 40.00 (1.1) 35.00 (1.0) 400 (2.8, 28) 30.00 (0.8) A 25.00 (0.7) 300 (2.1, 21) A B 200 (1.4,14) C 100 (0.7, 7) B D C D 0.0 0.0 20.00 (0.6) 15.00 (0.4) 10.00 (0.3) 5.00 (0.1) Air Consumption in SCFM (m3/min) A B C D 500 (3.5, 34.5) 0.00 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 (1.9) (3.8) (5.7) (7.6) (9.5) (11.4) (13.3)(15.2) (17.1) Fluid Flow in gpm (lpm) 311882T 23 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains English. MM 311882 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revision T, October 2014
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 Copyright : 2007, Rev. T, October 2014 Job Ref : Z092395 Marked : True Producer : Acrobat Distiller 7.0.5 (Windows) Web Statement : 311882T - T2 2:1 Ratio Transfer Pump, Instructions, English Keywords : 311882, 311882T, 311882EN-T, 311882EN, 295616, T2 2:1 Ratio Transfer Pump, nopct Modify Date : 2014:10:20 11:13:54-05:00 Creator Tool : FrameMaker 11.0 Create Date : 2005:04:27 11:19:54Z Metadata Date : 2014:10:20 11:13:54-05:00 Format : application/pdf Title : 311882T - T2 2:1 Ratio Transfer Pump, Instructions, English Creator : Emily Bringle Description : 311882 - T2 2:1 Ratio Transfer Pump, Instructions, English Document ID : uuid:c3c4fea3-f090-4bf6-b56e-89ac9c280a25 Instance ID : uuid:d3c08ab5-3d61-45b2-afd0-31a6e3773dcc Page Count : 24 Language : en Subject : 311882 - T2 2:1 Ratio Transfer Pump, Instructions, English Author : Emily BringleEXIF Metadata provided by EXIF.tools