Graco 3A0235G Feed Supply Pump Kits Users Manual Kits, Instructions Parts, English
3A0235G to the manual c4b14562-5bc2-4d0c-b88a-c77812f4e2fb
2015-04-02
: Graco Graco-3A0235G-Feed-Supply-Pump-Kits-Users-Manual-685870 graco-3a0235g-feed-supply-pump-kits-users-manual-685870 graco pdf
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
Instructions-Parts Feed Supply Kits For supplying viscous materials to Graco® HFR™ Metering System. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 3 for model information, including maximum working pressure and approvals. 246081 Package shown installed in HFR proportioning system. Some parts shown are not included in kit. 3A0235G EN Related Manuals Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Complete Supply Pump Systems . . . . . . . . . . . . . 3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . . . 6 Material Self-ignition . . . . . . . . . . . . . . . . . . . . . . . 6 Moisture Sensitivity of Isocyanates . . . . . . . . . . . . 6 Keep Components A and B Separate . . . . . . . . . . 6 Foam Resins with 245 fa Blowing Agents . . . . . . . 6 Changing Materials . . . . . . . . . . . . . . . . . . . . . . . . . 6 A and B Components . . . . . . . . . . . . . . . . . . . . . . . 7 ...................................... 7 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Flush Pumps Before Using . . . . . . . . . . . . . . . . . . . 8 Position Drums . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Feed Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 T2 2:1 and Monark 5:1 . . . . . . . . . . . . . . . . . . . 10 Husky 1050 Wall Mount . . . . . . . . . . . . . . . . . . 10 Husky 515 and 716 . . . . . . . . . . . . . . . . . . . . . . 11 Related Manuals Manual Description 313997 HFR Operation 313998 HFR Repair-Parts 311882 T2 2:1 Ratio Transfer Pump Instructions-Parts 307044 55 Gallon 5:1 Ratio Monark® Pump, Instructions-Parts 307043 5:1 Ratio Monark Air Motor, Instructions-Parts 308116 Stainless Steel Pumps, Instructions-Parts 308981 Husky™ 515 and Husky 716 Pump 309116 Husky 515 and Husky 716 Drum Pump Kits and Packages, Instructions-Parts 312877 Husky 1050 Pump 311211 High-Flo® Pumps, Instructions-Parts High-Flo® Pumps . . . . . . . . . . . . . . . . . . . . . . . 11 Install Air Supply Kit . . . . . . . . . . . . . . . . . . . . . . . 12 T2 2:1, Husky 515, Husky 716, and Husky 1050 Kits 12 Air Regulator Kit 248829 . . . . . . . . . . . . . . . . . . 12 Connect Air Lines . . . . . . . . . . . . . . . . . . . . . . . . . 12 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Changing Drums . . . . . . . . . . . . . . . . . . . . . . . . 13 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Complete Supply Pump Systems . . . . . . . . . . . 14 Complete Supply Pump Systems, continued . . 15 Fluid Supply Kits (1) . . . . . . . . . . . . . . . . . . . . . 16 Fluid Supply Kits (1), continued . . . . . . . . . . . . 18 Pump with Riser Tube Kits . . . . . . . . . . . . . . . . 19 Pumps with Riser Tube Kits, continued . . . . . . . 21 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 24 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 24 2 3A0235G Complete Supply Pump Systems Complete Supply Pump Systems Most packages include all air and fluid fittings and hoses. Approvals are only for the pumps and not for the entire package. ★ Complete Package only comes with one pump, air and fluid fittings, and hoses. Complete Package (fluid and air) Material Pump Model CS T2 2:1 Ratio 246081 24D091 24E396★ 24E397★ Husky™ 515 295616 295616 295616 295616 ✔ 246369 246484 ✔ SS ✔ ✔ Maximum Air Input Pressure Maximum Fluid Working Pressure 180 psi (1.2 MPa, 12.5 bar) 405 psi (2.8 MPa, 28 bar) ✔ 0359 100 psi (0.7 MPa, 7 bar) 24D092 Approvals 100 psi (0.7 MPa, 7 bar) ✔ 241564 0359 II 2 GD c IIC T4 Husky™ 716 246375 24D093 Husky™ 1050 24D328 24D094 246485 D54311 ✔ 647673 ✔ 651458 ✔ 100 psi (0.7 MPa, 7 bar) 100 psi (0.7 MPa, 7 bar) ✔ 125 psi (0.86 MPa, 8.6 bar) 125 psi (0.86 MPa, 8.6 bar) 0359 II 2 GD c IIC T4 Monark® 5:1 Ratio, 55 Gallon 24D095 218956 ✔ 24E398★ 218956 ✔ 24G714 ✔ 224350 Monark® 5:1 Ratio, 5 Gallon 24D096 902278 24E399★ 902278 High-Flo® Pumps 257769 JC20L1 257777 3A0235G JS20L1 0359 180 psi (1.2 MPa, 12.5 bar) 900 psi (6.2 MPa, 62 bar) II 1/2 G T2 ITS03ATEX11228 ✔ ✔ 180 psi (1.2 MPa, 12.5 bar) 900 psi (6.2 MPa, 62 bar) ✔ 100 psi (0.7 MPa, 7 bar) 200 psi (1.4 MPa, 14 bar) ✔ II 2 Gc T3 3 Warnings Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear impervious gloves when spraying or cleaning equipment. • If this equipment is used with isocyanate material, see additional information on isocyanates in Isocyanate Conditions Section of this manual. 4 3A0235G Warnings WARNING MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure. Disconnect power or air supply. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to: • Protective eyewear, and hearing protection. • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer. 3A0235G 5 Isocyanate Conditions Isocyanate Conditions To prevent exposing ISO to moisture: • Spraying materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates. • Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates. • Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area. • • • To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area. Material Self-ignition Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS. Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts. NOTE: The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature. 6 Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container. Keep the ISO lube pump reservoir (if installed) filled with Graco IsoGuard Select® (ISG), Part 24D086. The lubricant creates a barrier between the ISO and the atmosphere. Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system. Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use. Never use solvent on one side if it has been contaminated from the other side. Always lubricate threaded parts with ISO pump oil or grease when reassembling. Keep Components A and B Separate NOTICE To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (red) and component B (blue) parts. Foam Resins with 245 fa Blowing Agents Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system. Changing Materials • • • When changing materials, flush the equipment multiple times to ensure it is thoroughly clean. Always clean the fluid inlet strainers after flushing. Check with your material manufacturer for chemical compatibility. 3A0235G A and B Components A and B Components IMPORTANT! For all machines: • Material suppliers can vary in how they refer to plural component materials. • Be aware that when standing in front of the manifold on proportioner: • • Component A (Red) is on the left side. • Component B (Blue) is on the right side. 3A0235G • The A (Red) side is intended for ISO, hardeners, and catalysts. If one of the materials being used is moisture-sensitive, that material should always be in the A (Red) side. The B (blue) side is intended for polyols, resins, and bases. For ratios higher than 1:1, the higher volume is typically the B (Blue) side. 7 Grounding Grounding Position Drums Place component A (red) and component B (blue) drums as desired. Air hose (C) connecting feed pumps is 15 ft (4.57 m) long. See FIG. 1. The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. Pump: follow instructions in separate feed pump manual, supplied. HFR: see operation manual. Spray gun: see gun manual. Fluid supply container: follow local code. Object being sprayed: follow local code. Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity. To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun or dispense valve firmly to the side of a grounded metal pail, then trigger the gun or valve. Flush Pumps Before Using Fluid hose (103) connecting feed pumps to systems are 10 ft (3.05 m) long. Installation Feed Pump 1. Complete Setup instructions in pump manual before installing in drum or pail. a. For Riser Tube Kit 246419: Inspect bung o-ring (309) and gasket (303) in place. If either is worn or damaged, or if material shows signs of crystallization, replace. See page 22. b. If required, install desiccant dryer (Graco part no. 247616 not included). Remove elbow and 2 in. bushing supplied with desiccant dryer (6). Screw dryer 3/4 npt fitting into vent of moisture sensitive drum. NOTICE Lubricate bung o-ring with 217374 ISO Pump Oil each time you change drums. This keeps air and moisture from reacting with material and allows bung adapter to rotate freely. NOTICE Tighten pump clamps and external fasteners before first use. See pump manual. Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents. 8 3A0235G Installation Complete Package 246081 shown installed in HFR proportioning system. Includes *parts only. 101* (red) 2 2 2 Air Supply Kit. See 309827. 6* 101* (blue) 2 2* 2 C* *103 (Ref) D 103* (Ref) 2 2* FIG. 1: Installation 3A0235G 9 Installation T2 2:1 and Monark 5:1 Husky 1050 Wall Mount 1. Flush pumps, page 8. 1. Be sure wall can support weight of pump, hoses, and accessories, and can withstand stress during operation. 2. Position drums, page 8. 3. Open drum bung hole. Screw bung adapter with gasket into bung hole. See pump manual. 4. Install swivel fitting (102) in pump fluid outlet. See FIG. 2. 5. Connect hose (103) between swivel fitting (102) and the system swivel inlet (D, see FIG. 1). 6. Install air supply kit and connect air lines, page 12, to finish installation. 2. Position wall bracket (204) no more than 5 ft (1.52 m) above floor. Check that bracket is level. Attach to wall, using screws long enough to keep bracket from vibrating. See FIG. 3. 3. Connect swivel union (209) to pump inlet. 4. Install bushing (105) in pump air inlet. 5. Install pump (201) on bracket (204) securely, using screws (211), washers (210), and nuts (212). 6. Connect elbow (210) to top of riser tube kit (202). 7. Connect suction hose (203) to elbow (210) and inlet swivel (209). 201 8. Install swivel fitting (102) in pump fluid outlet. See FIG. 4. 9. Connect hose (103) between swivel fitting (102) and GMS™ swivel inlet fitting. See FIG. 4. 10. Install air supply kit and connect air lines, page 12, to finish installation. 102 bung adapter 103 201 105 209 TI10281a 203 210 212 FIG. 2. Standard 2:1 Kit 211 213 202 204 r_24D329_3a0235_1a FIG. 3. Husky 1050 Wall Mount 10 3A0235G Installation Husky 515 and 716 High-Flo® Pumps 1. Place riser tube (202) into drum. Tighten bung adapter securely. 1. Install elbow fitting (106) in pump (101) fluid outlet. 2. For carbon steel supply pump systems, Install swivel fitting (102) in pump (201) fluid outlet. 2. Connect hose (103) between elbow fitting (106) and fitting (102). Install nipple (109) and swivel fitting (110). 3. Connect hose (103) between swivel fitting (102) and GMS swivel fluid inlet fitting. 3. Connect swivel fitting (110) and GMS swivel fluid inlet fitting. 4. Install air supply kit and connect air lines, page 12, to finish installation. For A-Side only: remove 1/2 npt swivel fitting from GMS swivel fluid inlet prior to connecting swivel fitting (10). 201 4. Connect air lines (not supplied), page 12, to finish installation. 102 101 103 202 110 106 102 r_246481_3a0235a_1a FIG. 4. Husky 716 109 103 111 r_257769_3a0235a_1a FIG. 5: High-Flo 3A0235G 11 Install Air Supply Kit Install Air Supply Kit Connect Air Lines T2 2:1, Husky 515, Husky 716, and Husky 1050. See manual 309827 to install air supply kit. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. T2 2:1, Husky 515, Husky 716, and Husky 1050 Kits 5:1 Monark Kits 1. Shut off air valves (V) at feed pumps (201). 201 1. Supply clean, dry filtered air to feed pumps. V 2. See manual 309827 to install air supply kit. 7 Air Regulator Kit 248829 1b The air regulator kit (7) is only used with the Monark kits. 1a r_256276_312769_2A 1. Install air regulator kit (7). 2. Interconnect tee fitting (1f) and quick disconnect fitting (1b) on pump with air hose (1a). 2. Install air line (1a) with quick disconnect coupler (1b) provided. 3. Connect air line and quick disconnect coupler to air regulator (7). 12 3A0235G Operation Operation Maintenance Startup NOTE: 1. See Load fluid with feed pumps in system operation manual. 2. Open feed pump air regulator. 3. Open feed pump bleed-type master air valve. See supplied pump manual for maintenance, repair, and parts information. Lubricate bung o-ring (309) with 217374 ISO Pump Oil each time you change drums. This keeps air and moisture from reacting with ISO. 4. Adjust air to feed pump with needle valve. NOTE: • • • Cold, viscous material may be difficult to prime. Use needle valve to reduce air flow to motor. Do not plug or shut off pump fluid outlet when priming. Fluid must be free to flow through pump to prime. To increase pump flow rate and reduce icing, remove pump muffler. This will increase exhaust noise. 5. Never let pump run when drum is empty. A dry pump can accelerate and damage itself. If pump is running too fast, stop it immediately. Check and refill fluid supply, or flush with compatible solvent. Always prime entire system to remove any air. Do not let material harden in pump. Whenever pump is removed from drum, inspect bung o-ring (309) and gasket (303) in place. If either is worn or damaged, or if ISO shows signs of crystallization, replace. See page 22. Tighten pump clamps and external fasteners periodically. See pump manual. Repair See supplied pump manual for maintenance, troubleshooting, and repair procedures. Shutdown See Shutdown and Pressure Relief Procedure in system operation manual. Close feed pump bleed-type master air valve. Changing Drums NOTICE To prevent cross-contamination of fluid when changing drums, complete changing one component before changing second component. 1. See Shutdown above. 2. Remove riser tube from drum. Install in new drum, page 8. 3. Lubricate bung o-ring, page 8. 4. See Load fluid with feed pumps in GMS operation manual. 3A0235G 13 Parts Parts Complete Supply Pump Systems Each complete supply pump system includes a fluid supply kit, air supply kit, and desiccant dryer. See parts lists on pages 15. Two Pump Systems One Pump Systems Pump Material Complete Pump System Fluid Supply Kit (1) (See Page 16) Husky 515 CS 246369 246481 SS 24D092 24D100 CS 246375 246482 SS 24D093 24D101 CS 24D328 24D332 SS 24D094 24D102 CS 246081 246898 24E396 SS 24D091 24D103 24E397 Monark 5:1, 5 Gallon SS 24D096 24D104 24E399 Monark 5:1, 55 Gallon CS 24D095 24D105 24E398 Monark 5:1, 55 Gallon SS 24D105 24G714 High-Flo CS 257769 257769 (page 18) High-Flo SS 257777 257777 (page 18) Husky 716 Husky 1050 T2 2:1 246081 Package shown installed in HFR proportioning system. Includes * parts only. 2* 2 6* Complete Pump System 2* 2 1* (blue) 1* (red) 1 1*(Ref) 1* (Ref) 1 2 14 2* 1 Fluid Supply Kit. See page 16. 2 Air Supply Kit. See 309827. 3A0235G Parts Complete Supply Pump Systems, continued Ref. 1★ 2 6 7❖ Part Description 246481 KIT, fluid supply, Husky 515; 246369 24D100 KIT, fluid supply, Husky 515; 24D092 246482 KIT, fluid supply, Husky 716; 246375 24D101 KIT, fluid supply, Husky 716; 24D093 24D332 KIT, fluid supply, Husky 1050; 24D328 24D102 KIT, fluid supply, Husky 1050; 24D094 246898 KIT, fluid supply, T2 2:1; 246081 24D103 KIT, fluid supply, T2 2:1; 24D091 24D104 PUMP, Monark 5:1, 5 gallon; 24D095 24D105 PUMP, Monark 5:1, 55 gallon; 24D096; see manual 307044 257769 KIT, complete, High-Flo; cs 257777 KIT, complete, High-Flo; ss 246483 AIR SUPPLY KIT; see 309827 247616 KIT, desiccant dryer; for A (red) side; see page 14 248829 REGULATOR KIT, air, feed pump Qty. 1 1 1 Husky and T2 2:1 Kits See illustration on page 14. 24D096 and 24E399 Monark 5:1 5 Gallon Feed Pump Kit 1 1 7 1 1 1 1 1 1 1 1 1 1 1 ★ See Fluid Supply Kits on page 16. ❖ Only for Monark 5:1 kits. r_24D095_3a0235_1a 24D095 and 24E398 Monark 5:1 Kit 55 Gallon Feed Pump Kit 1 7 r_24D096_3a0235a_1a 3A0235G 15 Parts Fluid Supply Kits (1) Carbon Steel Husky Kits 101 24D105 55 Gallon Monark 5:1 Kit 101 102 103 103 r_246481_3a0235a_1a Stainless Steel Husky Kits 101 103 246898 and 24D103 T2 2:1 Kits 101 r_24d101_3a0235a_1a 102 103 24D104 Monark 5:1 5 Gallon Kit 101 103 TI10282a r_24D104_3a0235a_1a 16 3A0235G Parts Fluid Supply Kits (1), continued Each fluid supply kit contains two pumps with riser tubes, fittings, and hoses needed to supply fluid from the pumps to the proportioner. Use the tables below to identify what parts are used for the carbon steel and stainless steel fluid supply kits. See page 16 for fluid supply kit illustrations. High-Flo pumps are on page 18. Carbon Steel Fluid Supply Kits Husky 515 (246481) Husky 716 (246482) Husky 1050 (24D332) T2 2:1 (246898) Qty. 246484 246485 647673 295616 2 Ref. No. Description 101 KIT, pump with riser tube 102 UNION, swivel; UNION, swivel; 3/4 npt(m) x 3/4 npsm(f) 157785 157785 157785 157785 2 103 HOSE, fluid; 3/4 npt (mbe); 3/4 in. (19 mm) ID; 10 ft (3.05 m); nylon 217382 217382 217382 217382 2 104 FITTING, swivel; 1/2 npt(m) x 3/4 nps(f); (not shown) (use as necessary to adapt 1/2 npt A side “red” inlet) 113344 1 105 BUSHING, reducer, 1/2 npt(m) x 3/4 npt(f); use on 1/2 npt A side (red) inlet hose (not shown) 104969 104969 1 104969 Stainless Steel Fluid Supply Kits Ref. No. Description 101 KIT, pump with riser tube 102 UNION, swivel; UNION, swivel; 3/4 npt(m) x 3/4 npsm(f) 103 HOSE, fluid; 3/4 npt (mbe); 3/4 in. (19 mm) ID; 10 ft (3.05 m); ss 105 BUSHING, reducer (not shown) 106 NIPPLE, reducing; 1 in. npt x 3/4 npt, ss; see page 19. 3A0235G Husky 515 (24D100) Husky 716 (24D101) Husky 1050 (24D102) T2 2:1 (24D103) Monark 5:1 (24D104) Monark 5:1 (24D105) Qty. 233052 233057 651458 295616 902278 224350 2 122268 24C656 24C656 24C656 16C632 16C628 24C656 1 24C656 24C656 2 1 1 17 Parts Fluid Supply Kits (1), continued 257769, Carbon Steel High-Flo Fluid Supply Kit 257777, Stainless Steel High-Flo Fluid Supply Kit 101 112 110 Ref. No. Description 257769 257777 Qty. 101 PUMP, High-Flo JC20L1 JS20L1 2 102 UNION, swivel 202966 122639 2 103 HOSE, coupled; 1/2 npt; 6 ft (10.9 m); nylon 220372 106 102 HOSE, coupled; 1/2 npt; 6 ft (10.9 m); ss 106 109 FITTING, union, adapter, 90°; 1/2 npt(f) x 1/2 nps(m) 214959 102806 FITTING, union, adapter, 90° 103 109 NIPPLE; 3/4-14 npt 110 FITTING, union, swivel; 3/4 npt 100627 r_257769_3a0235a_1a 18 2 2 123111 118459 FITTING, union, swivel; 3/4 npt 2 2 510786 NIPPLE; 3/4 in. npt 111 2 2 2 112268 2 111 FRAME 253692 253692 2 112 KIT, floor/stand bracket 247312 247312 2 113 CONTROL, air, integrated, locking NXT011 NXT011 2 114 SCREW, cap, sch 112566 112566 4 3A0235G Parts Pump with Riser Tube Kits Pump Kit No. Material Husky 515 246366 CS 233052 (see manual 309116) Plastic 246367 CS 233057 (see manual 309116) SS 24D329 CS 24D097 SS 295616 (see manual 311882) SS Monark 5:1, 5 Gallon 24D098 SS Monark 5:1, 55 Gallon 24D099 CS Husky 716 Husky 1050 T2 2:1 246367 Husky 716 Pump 201 203 202 246366 Husky 515 Pump TI3450a 201 Ref. 201 202 203 202 Part Description Qty. 246485 PUMP, Husky 716; see 308981 and 1 read NOTICE below 246419 RISER TUBE KIT; see page 22 1 158555 NIPPLE, reducing; 1 in. npt x 3/4 1 npt 16C628 NIPPLE, reducing; 1 in. npt x 3/4 1 npt, ss; only used with fluid supply kit 24D101 NOTICE 246485 Husky 716 Pump is built specifically for use with isocyanates and is tested with oil. To order replacement parts and repair kits, refer to the Husky 716 parts list in manual 308981. Ref. 201 202 Part Description Qty. 246484 PUMP, Husky 515; see 308981 and 1 read NOTICE below 246419 RISER TUBE KIT; see page 22 1 NOTICE 246484 Husky 515 Pump is built specifically for use with isocyanates and is tested with oil. To order replacement parts and repair kits, refer to the Husky 515 parts list in manual 308981. 3A0235G 19 Parts Pumps with Riser Tube Kits, continued 24D329 CS Husky 1050 Pump 24D097 SS Husky 1050 Pump 201 201 105 105 209 203 210 212 211 213 202 209 210 211 202 213 204 203 212 204 r_24D097_3a0235_1a r_24D329_3a0235_1a Ref. Part Description Qty. 201 647673 PUMP, Husky 1050; 24D332, see 1 313435 202 246419 RISER TUBE KIT; 24D332, see page 1 22 1 203 214961 HOSE, suction; 3/4 npt (mbe); 3/4 in. (19 mm) ID; 6 ft (1.8 m); neoprene 204 189233 BRACKET, wall 1 209 202965 UNION, swivel, pump inlet; 1 1 in. npt(m) x 3/4 npsm(f) 210 107409 ELBOW, swivel, riser tube; 90°; 1 1 in. npt(m) x 3/4 npsm(f); 24D332 211 100214 WASHER, lock; 5/16 4 212 100450 SCREW, cap, hex-hd; 5/16-18; 4 1 in. (25 mm) 213 111303 NUT, hex; 5/16-18 4 20 Ref. Part Description Qty. 201 651458 PUMP, Husky 1050; 24D102, see 1 manual 313435 202 183549 TUBE, section; 24D100 1 203 221171 HOSE, suction; 3/4 npt (mbe); 1 3/4 in. (19 mm) ID; 6 ft (1.8 m); neoprene 204 189233 BRACKET, wall 1 209 16C629 FITTING, adapter, swivel; 1 npt(m) x 1 3/4 npt(f), ss 210 16C631 ELBOW, swivel 90°, 1/2 npt(m) x 1/2 1 nps(f), ss; 24D102 211 100214 WASHER, lock; 5/16 4 212 100450 SCREW, cap, hex-hd; 5/16-18; 4 1 in. (25 mm) 213 111303 NUT, hex; 5/16-18 4 214 183553 PLUG, bung; 24D102 2 3A0235G Parts Pumps with Riser Tube Kits, continued 24D098, 5 Gallon 5:1 Monark Ref. No. 2 6 7 201 24D099, 55 Gallon 5:1 Monark Part No. Description 246483 AIR SUPPLY KIT; see 309827 247616 KIT, desiccant dryer; for A (red) side; see page 14 248829 REGULATOR KIT, air, feed pump 902278 PUMP, Monark 5:1; includes 902147, see manual 308116 Qty. 1 1 Ref. No. 2 6 1 1 7 201 Part No. Description 246483 AIR SUPPLY KIT; see 309827 247616 KIT, desiccant dryer; for A (red) side; see page 14 248829 REGULATOR KIT, air, feed pump 218956 PUMP, Monark 5:1; see 307044 Qty. 1 1 1 1 201 7 201 7 air inlet fitting 1/4 npt r_24D098_3A0235A_1a 3A0235G 21 Accessories Accessories Riser Tube Kit, 246419 Ref. 301 302 303 304 305 306 307 308 309 Part 159101 156592 106537 15B728 15B727 15B921 100279 159100 110831 Return Tube Accessories Description HOUSING, valve, intake TUBE, riser GASKET, bung ADAPTER, bung FITTING; 1 in. npt SPACER BALL RETAINER, ball O-RING Qty. 1 1 1 1 1 1 1 1 1 See manual 309852 for installation and parts. Material Part Carbon Steel 246477 Stainless Steel 24D106 Circulation Kits See manual 309852 for installation and parts. 1 Lubricate with 217374 ISO Pump Oil each time you change drums. 305 309 304 Material Part Carbon Steel 24E379 Stainless Steel 24D107 1 246483 Air Supply Kit 303 See manual 309827 for installation and parts. 15C381 Desiccant Dryer Cartridge 302 233048 Husky 716 Accessory Kit Includes stainless steel bung base and stainless steel suction tube. See manual 309116. Material Filters 307 308 301 306 TI3445a 22 Material Part Carbon Steel 213058 (60 mesh) Stainless Steel 244053 (60 mesh) NOTE: See manual 307282 for installation and parts. 3A0235G Technical Data Technical Data Maximum air input pressure T2 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monark 5:1 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . Husky 716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Husky 1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 psi (1.2 MPa, 12 bar) 180 psi (1.2 MPa, 12 bar) 100 psi (0.7 MPa, 7 bar) 125 psi (0.86 MPa, 8.6 bar) 100 psi (0.7 MPa, 7 bar) Maximum fluid working pressure T2 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monark 5:1 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . Husky 716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Husky 1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 psi (2.8 MPa, 28 bar) 900 psi (6.2 MPa, 62 bar) 100 psi (0.7 MPa, 7 bar) 125 psi (0.86 MPa, 8.6 bar) 200 psi (1.4 MPa, 14 bar) Wetted parts Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fluid hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suction hose (Husky 1050 only). . . . . . . . . . . . . . . . . . . . Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See supplied pump manual Carbon steel Nylon Neoprene Carbon steel 3A0235G 23 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Toll Free: 1-800-746-1334 or Fax: 330-966-3006 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains English. MM 3A0235 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA Copyright 2010, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revised February 2012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 Job Ref : A141M00000, Z071562 Producer : Acrobat Distiller 7.0 (Windows) Copyright : 2010, Rev G 02/2012 Marked : True Web Statement : 3A0235G - Feed Supply Pump Kits, Instructions-Parts, English Keywords : 3A0235, Feed Supply Pump Kits, HFR, 246081, 24D091, 24E396, 24E397, 246369, 24D092, 246375, 24D093, 24D328, 24D094, 24D095, 24E398, 24G714, 24D096, 24E399, 257769, 257777, nopct Create Date : 2009:08:26 11:29:32Z Creator Tool : FrameMaker 9.0 Modify Date : 2012:02:28 14:00:40-05:00 Metadata Date : 2012:02:28 14:00:40-05:00 Format : application/pdf Creator : Heath McCartney Description : Feed Supply Pump Kits, for supplying viscous materials to Graco HFR Metering System Title : 3A0235G - Feed Supply Pump Kits, Instructions-Parts, English Document ID : uuid:5363da59-ccd9-4016-af3a-9c490993b83d Instance ID : uuid:234de3a0-3f76-474e-8da3-b9c86975e956 Page Count : 24 Subject : Feed Supply Pump Kits, for supplying viscous materials to Graco HFR Metering System Author : Heath McCartneyEXIF Metadata provided by EXIF.tools