Graco Msa 10 Air Operated Pump Users Manual
2015-04-02
: Graco Graco-Msa-10-Air-Operated-Pump-Users-Manual-686372 graco-msa-10-air-operated-pump-users-manual-686372 graco pdf
Open the PDF directly: View PDF .
Page Count: 2
DESCRIPTION
The MSA-10 is an air-operated pump with an ad justable volume
output. It is designed to be used in series progressive oil or grease
lubrication systems. Lubricant can be supplied to the MSA-10
pump by either a gravity feed reservoir or a pressurized source
such as a bulk header that exerts up to 500 psi at the pump inlet.
This pressure handling capability is a result of the pump pistons
valving ac tion which prevents lubricant from flowing into the lube
system when the piston is in the priming position. The MSA-10 is
supplied as a single-acting pump. However, it can easily be field-
converted to double-acting by removing the plastic vent plug from
the double-acting port and installing an air line.
FEATURES
Adjustable lube output, from .040 to .120 cubic inches per •
stroke, permits a broad range of applications.
The MSA-10 is ideal for bulk header lube systems because it •
can handle up to 500 psi inlet pressure.
Single-or double-acting air cylinder provides wide choice of •
controls.
Ability to pump either oil or grease expands the opportunity to •
standardize on the MSA-10 through out the plant or shop.
High pressure relief protection reduces chance of damage to •
the lube system in case of blockage.
Can be piped to standard Trabon reservoirs. (Refer to bulletin •
L12000 for reservoirs.)
OPERATION
When air is supplied in the single-acting port (SA), the pump piston
(A) is moved forward. The lube inlet is closed by the piston (A/B). The
lubricant in the chamber (C) is forced into a channel in the middle
of the piston (B1). An outlet hole (D) from that channel opens into an
undercut (E) on the piston. When the undercut (E) opens to the lube
outlet, the lubricant from the chamber (C) flows, under pressure, to
the lube system. If a blockage occurs in the lube system, the rupture
indicator (not shown) opens and the pressure is vented. When the air
has been vented from the single-acting inlet, the piston return spring
(G) returns the piston to its original position. If the pump is double-
acting, air will be supplied in the double-acting inlet (DA) as air is
vented from the single-acting port.
DA DC
AB
B1
E
SA
G
A1/4-18
N.P. S.F.
DOUBLE
ACTING PORT
.34(8.7) DIA.
2 MOUNTING
HOLES
LUBE OUTLET
1/4-18 N.P. S.F.
1/4-18 N.P. S.F.
SINGLE
ACTING PORT
14-18 N.P. S.F.
LUBE INLET
EXTERNAL
CHECK VALVE
MSA-10 Air Operated Pump
SPECIFICATIONS
Material Steel
Output per Stroke 0.040-0.120 cu.in. (0.66-1.97 cm3)
Max Pump Stroke per Min
Single-Acting 15
Double-Acting 60
Operating Pressure
Air Inlet 40-150 psi (275.8-1034.2 kPa)
Max Lube Inlet 500 psi (3447.5 kPa)
Max Lube Outlet 1450 psi (9997.7 kPa), w/Standard 1450
psi Rupture-To-Atmosphere Indicator
Lubricant Oil or Grease
Air to Lube 25:1
DIMENSIONS
Inches (mm)
INSTALLATION INSTRUCTIONS
Mount pump using both mounting holes.1.
Seal all pipe connections. 2. DO NOT USE PTFE TYPE TAPE.
Cycle the pump until all air is removed and lubricant runs clear 3.
at the outlet.
If you intend the MSA-10 to operate as a double-acting pump, 4.
remove the plastic vent orifice plug from the double-acting inlet
port and install the air line to that inlet.
To adjust pump output, remove adjustment screw cap and turn 5.
the screw clockwise to reduce output, or counterclockwise to
increase output.
9348
7
6
5
4
3
2
1
1
2.87 Dia.
(73.0)
4.64
(117.7) 6.48
(164.6)
10.75
(273.0)
RUPTURE-TO-
ATMOSPHERE
INDICATOR
1/4 - 8 N.P.S.F.
LUBE INLET
(2) .34 DIA.
MOUNTING
HOLES
2.12
(54.0)
1.50
(38.1)
.81
(20.6)
1.45
(36.8)
7.42
(188.4)
5.50
(139.7)
Dimension to centerline
single- and double-acting ports
.75
(19.0)
1.25
(31.8)
SPARE PARTS KIT
A handy spare parts kit is available and includes:
Appropriate O-rings (1, 2, 3, 4, 5, and 6); two gaskets (7): external
check valve (for replacement of both external and internal types) (8);
piston return spring (9); and complete instructions for installations.
All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
©2006-2009 Graco Inc. Form No. L12850 Rev. B 2/09 Printed in U.S.A. All other brand names or marks are used for identification purposes and are trademarks of their respective owners. All written and
visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
Contact us today!
To receive product information or talk with a Graco representative,
call 800-533-9655 or visit us online at www.graco.com.
ORDERING INFORMATION
Description Part No. Old Part No.
MSA-10 Air Operated Pump 562854 140-000-111
1450 psi Rupture-To-Atmosphere Indicator – 511-839-100
Spare Parts Kit 563912 560-001-550
Air Inlet Restrictor Valve 563072 463-410-080
For MAS-10 pumps with higher max psi, refer to Bulletin L15401 or consult
your Trabon distributor or the factory.