Trabon MSP Zero-Leak
Inlet Shut-off Valve
®

Description
The MSP Zero-Leak inlet shut-off valve is designed for use in oil
only header lines, for the lubrication of extended systems and/or
systems with varied lube frequencies. Such applications include
automotive transfer lines, conveyor lines, flexible machining
centers and also complete plant lubrication.
The MSP Zero-Leak inlet shut-off valve can be mounted as the
inlet section to any primary (master) divider valve assembly. By
using a remote manifold kit, it can be teed off of the header line
to a remote primary (master) divider valve assembly.
The MSP Zero-Leak shut-off valve is supplied normally closed to
flow. When the coil is energized, the zero-leak valve is opened,
allowing oil to flow through. Once the proper amount of oil has
been dispensed, the valve is de-energized, shutting off oil flow.
The Zero-Leak valve is designed for header-line pressures up to
1500 psi.

•	

Inlet restrictor/filter available for use in continuous
pressurized header line systems. This will slow down lube
inrush and enable accurate control of the lube systems.
Order Part Number 563074 (463-410-204) for NPT pipe
inlet.

•	

Coil is molded and sealed, making it impervious to coolant.
Allows mounting of valve in harsh environments.

Features/benefits
•	

Designed for use with an oil header line system, which is
an economical method of providing lubricant to extensive
systems. Reduces plumbing and installation cost.

•	

When used in a header line system, lubrication zones are
easily extended or deleted as changes are made to the lube
circuit. This reduces engineering design costs.

•	

Enables individual zone lubrication. Prevents over
lubrication thus saving on lubrication costs.

•	

Facilitates individual zone operation and monitoring.
Identifies a fault in a specific zone for ease of
troubleshooting. Helps lessen machine downtime, which
means more production time.

•	

Solenoid can be rotated through1800 to accommodate
any electrical hook up --orientation. Allows for faster
installation to reduce costs.

•	

Available with three pin mini-connection as standard

•	

Available with NPSF pipe, BSPP or SAE, o-ring sealed ports.

Operation
The MSP Zero-Leak inlet shut-off valve is used in conjunction
with an oil header line lube system with each shut-off valve
representing a zone of lubrication (See Fig.1). The header line
can either be continuously (use restrictor) or intermittently
pressurized upon demand. When the particular machine zone
requires lubrication, based upon a pre-determined interval, an
electrical signal from a Trabon Flexi-Monitor ® or machine PLC
will sequentially energize the solenoids attached to the shutoff valves (A1), (A2), and (A3). This will open the valve and
allow lubricant from the header line to cycle the divider valve,
thus providing lubricant to the points within the zone. Once the
zone has received the proper amount of lubrication, determined
through monitoring the cycle switch (B) or proximity switch (B)
for appropriate number of cycles, the controller will de-energize
the solenoid and the valve will shut-off lubricant flow.
HEADER LINE

)(

)(

(A3)

)(

(A2)

(B)

(B)

(A1)
(B)

PUMP AND
RESERVOIR

MASTER
DIVIDER

FIGURE 1
SECONDARY DIVIDERS

SPECIFICATION
Position

Normally closed

Material

Anodized Aluminum body

Pressure (max)

1500 psi (104 bar)

Lubricant

Oil up to 5000 SUS

Electrical Rating:
(AC)

120V at 60 Hz, 9.5W continuous duty coil,
class "H" insulation, .220 amps holding

(DC)

24V, 28W continuous duty coil w/
diode, class "H" insulation

Filtration

(ISO 18/14) or better oil cleanliness level

Wiring Diagram

NOTE: Diode on DC
	
version only

Graco endorses the SAE recommendation of ISO 18/14 (ISO 4406) oil cleanliness for most bearing
applications. Some high speed bearing may require cleaner oil. Consult the bearing manufacturer for
recommendation.

COMPONENT ORDERING
Description

COMPONENT ORDERING (continued)
Part No.

Old Part No.

Zero-Leak valve, 120 VAC w/
Brad Harrison 3 pin connector

Replacement Coil, 120 VAC

557226

492-120-206

Replacenment Coil, 24 VDC

557225

492-120-205

563461

527-004-360

563074

463-410-204

(1/4-18 NPSF)

563460

527-004-320

Remote mount manifold kit (includes outlet
manifold, O-Ring & 2 Mtg screws)

(9/16-18 SAE)

563468

527-005-200

(1/4-18 NPSF)
Inlet Restrictor w/90 Micron Last Chance Filter

Zero-Leak valve, 24 VDC w/Brad
Harrison 3 pin connector

(1/4 NPTF)

(1/4-18 NPSF)

563464

527-004-870

Brad Harrison Mating Cables

(9/16-18 SAE)

563467

527-005-180

6ft (1.3m) (3 pin) straight

558021

570-999-080

Zero-Leak valve (no coil), 1/4 BSPP

563462

527-004-770

12ft (3.7m) (3 pin) straight

558022

570-999-090

Repair Kit (w/wrench nut)

563933

560-002-640

Note: See bulletin L10105 for Modular Zero-Leak

All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.

Contact us today!
To receive product information or talk with a Graco representative,
call 800-533-9655 or visit us online at www.graco.com.
©2007-2009 Graco Inc. Form No. L10104 Rev. B 1/09 Printed in U.S.A. All other brand names or marks are used for identification purposes and are trademarks of their respective owners. All written and
visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2010:05:14 09:18:02-05:00
Keywords                        : Trabon MSP Zero-Leak Inlet Shut-off Valve, L10104, 10104, Divider Valve
Modify Date                     : 2012:05:24 16:39:03-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:072f46f2-0e1c-7049-a6d8-abbbf1fab93d
Document ID                     : adobe:docid:indd:6defe701-ef99-11dd-ae10-def5b81dbe74
Rendition Class                 : proof:pdf
Derived From Instance ID        : 6defe700-ef99-11dd-ae10-def5b81dbe74
Derived From Document ID        : adobe:docid:indd:27718bbd-2191-11dc-81ed-c9c361228cd0
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 299.99, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 299.99, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:2F431AC794F811DCAD1BE55D94AD26ED, uuid:BEB25A38092E11DC9E10DC92E31E0F92, uuid:9A2FE52B219211DCA398EECF0DEF711A, uuid:BEB25A38092E11DC9E10DC92E31E0F92
Manifest Reference Document ID  : uuid:CBA7313B8D1011DC996DEA6B667C972D, uuid:BEB25A37092E11DC9E10DC92E31E0F92, uuid:9A2FE52A219211DCA398EECF0DEF711A, uuid:BEB25A37092E11DC9E10DC92E31E0F92
Metadata Date                   : 2012:05:24 16:39:03-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 13872 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : Trabon MSP Zero-Leak Inlet Shut-off Valve
Creator                         : 
Subject                         : Trabon MSP Zero-Leak Inlet Shut-off Valve, L10104, 10104, Divider Valve
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu