Model FSD-211 Combination APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 4 in. wg (1 kPa) for operation and dynamic closure in emergency fire smoke situations. Model FSD-211 may be installed vertically (with blades running horizontal) or horizontally and is rated for airflow and leakage in either direction. Ratings UL 555 Fi re Resistance Rating Fire Rating: 11⁄2 Hours Dynamic Closure Rating: Actual ratings are size dependent Maximum Velocity: 2000 fpm (10.2 m/s) Maximum Pressure: 4 in. wg (1 kPa) Maximum Temperature: 350ºF (177°C) -- Depending on actuator UL 555S Leakage Rating Leakage Class: I Operational Rating: Actual ratings are actuator dependent Maximum Velocity: 2000 fpm (10.2 m/s) Maximum Pressure: 4 in. wg (1 kPa) Maximum Temperature: 350ºF (177°C) - Depending on actuator FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL555 11⁄2 Hour Fire Resistance Rating Model FSD-211 meets the requirements for fire dampers, smoke dampers and combination fire smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101 & 105 IBC International Building Codes ICBO Uniform Building Codes CSFM California State Fire Marshal Fire Damper Listing (#3225-0981:103) Leakage (Smoke) Damper Listing (#3230-0981:104) New York City (MEA listing #260-91-M) “UL CLASSIFIED (see complete marking on product)” “UL CLASSIFIED to Canadian safety standards (see complete marking on product)” Standard 555 & 555S (Listing #R13317) Standard Construction Frame: Blades: Seals: Jamb Seals: Linkage: Closure Device: Axles: Bearings: Size Limitations: Minimum Size: Maximum Size: 5 in. x 1 in. (127mm x 25mm) galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17 in. (432mm) high to maximize free area and performance. 16 ga. (1.5mm) galvanized steel, reinforced with 3 longitudinal structurally designed vee’s. Extruded silicone rubber blade seals Flexible stainless steel jamb seals Concealed in jamb. UL listed 165°F (74°C) RRL 1⁄2 in. (13mm) dia. plated steel Bronze sleeve type 8 in. W x 6 in. H (203mm W x 152mm H) Single Section: 32 in. W x 50 in. H (813mm W x 1270mm H) 36 in. W x 48 in. H (914mm x 1219mm) Multiple Section: Horizontal: 144 in. W x 96 in. H (3658mm W x 2438mm H) Vertical: 128 in. W x 100 in. H (3251mm W x 2540mm H) Optional Features: Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. R W* RH H* • RRL/OCI (Open closed indication switches) • Electric or pneumatic actuators • POC retaining angles • Smoke detectors • Momentary switch LH • Pneumatic Relief Valve (PRV) • Security bars *W&H dimensions furnished approximately ¼in. (6mm) undersize. • TOR (remote override of 165ºF (74°C) or 212ºF (100°C) closure (Add sleeve thickness for overall sleeved damper dimension) allows damper to perform smoke management functions during a Right hand drive is shown. Left hand drive is available upon request. fire emergency) • 165ºF (74°C), 212°F (100°C), 250ºF (121°C), and 350ºF (177°C) RRL's available. Installation installations available at www.greenheck.com • Sealed transitions and sleeves Pressure Drop Data FSD-211 This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of .075 lb/ft3 (1.201 kg/m3). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 5D 6D 5D D 4 (W) (H) 3.14 FigureDrop 5.3 AMCA 5.2 Pressure FSD-211 5D D= 4 (W) (H) 3.14 Figure 5.2 Figure 5. 5 12 in. x 12 in. (305mm x 305mm) Velocity (fpm) Pressure Drop (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.04 0.14 0.31 0.55 0.86 1.24 1.69 2.20 24 in. x 24 in. (610mm x 610mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.02 0.07 0.16 0.29 0.45 0.65 0.89 1.16 R 36 in. x 36 in. (914mm x 914mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.01 0.04 0.09 0.16 0.25 0.36 0.49 0.64 12 in. x 48 in. (305mm x 1219mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. 0.01 0.06 0.13 0.23 0.36 0.52 0.70 0.92 48 in. x 12 in. (1219mm x 305mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.03 0.10 0.23 0.41 0.63 0.91 1.24 1.62 AMCA 5.3 Pressure Drop FSD-211 5D 6D Figure 5.3 5D D= 4 (W) (H) 3.14 Figure 5.2 Figure 5. 5 12 in. x 12 in. (305mm x 305mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.02 0.09 0.20 0.36 0.56 0.81 1.10 1.44 24 in. x 24 in. (610mm x 610mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.01 0.04 0.09 0.16 0.25 0.35 0.48 0.63 R 36 in. x 36 in. (914mm x 914mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.01 0.03 0.06 0.11 0.17 0.24 0.33 0.42 12 in. x 48 in. (305mm x 1219mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. 0.01 0.04 0.10 0.17 0.27 0.39 0.53 0.70 48 in. x 12 in. (1219mm x 305mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.02 0.07 0.16 0.29 0.45 0.64 0.88 1.14 D 4 (W) (H) 3.14 AMCA 5.5 Pressure Drop 12 in. x 12 in. (305mm x 305mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.06 0.22 0.50 0.89 1.39 2.00 2.72 3.55 24 in. x 24 in. (610mm x 610mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.03 0.14 0.31 0.54 0.85 1.22 1.66 2.17 R FSD-211 36 in. x 36 in. (914mm x 914mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.03 0.12 0.26 0.46 0.73 1.05 1.42 1.86 12 in. x 48 in. (305mm x 1219mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. 0.03 0.13 0.30 0.53 0.83 1.19 1.62 2.11 48 in. x 12 in. (1219mm x 305mm) Pressure Drop Velocity (fpm) (in. wg) 500 1000 1500 2000 2500 3000 3500 4000 0.04 0.17 0.38 0.67 1.04 1.50 2.05 2.67 Application Data Damper Sleeve Dimensional Data The drawings below and corresponding table show the position of the FSD-211 damper when mounted in a factory sleeve. The standard mounting locations provide enough space for the mounting of actuators, controls and allow space for installation of retaining angles and duct connections. The standard location of a damper mounted in a factory sleeve ("A" dimension) is shown below. The damper can be positioned at other locations within a range of 6 in. (152mm) to 12 in. (305mm) for the "A" dimension. 1 1/2 in. max. "A" Dimension in. (mm) All Dampers* 3 3/4 in. Standard Maximum 7 3/16 (183) 12 (305) 12 (305) 12 (305) When H is 11 in. (279mm) or less with OCI, RRL, or TOR 6 in. *With the exception of dampers 10 in. high (254mm) or less. NOTE: Entire damper frame is not required to be installed within the wall. The damper blades, when closed should be contained within the wall. Varies 5 3/8 in. LH RH Right hand drive is shown Left hand drive available upon request A 5 in. Sleeve Length Actuators and Accessories Space Envelopes Externally mounted actuators always require space outside of the damper sleeve. The “S” dimension illustrates the clearance required for various available actuators. T* S On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sleeve. “B” and “T” dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated. B* B* T* Actuator Type/Model With RRL, RRL/OCI, or TOR With RRL, RRL/OCI, or TOR ML-4XXX Series Honeywell 5¼ in. (133mm) ¾ in.(19mm) 6 in. (152mm) MS-4XXX Series Honeywell 6 in. (152mm) 3/8 in. (10mm) 6 in. (152mm) MS-4120 Series Honeywell 6 in. (152mm) 3/8 in. (10mm) 6 in. (152mm) ML-8XXX Series Honeywell 5¼ in. (133mm) ¾ in.(19mm) 6 in. (152mm) MS-8XXX Series Honeywell 6 in. (152mm) 6 in. (152mm) 6 in. (152mm) MS-8120 Series Honeywell 6 in. (152mm) 6 in. (152mm) 6 in. (152mm) S 120 Volt AC 24 Volt AC Pneumatic (25 psi min.) 331-4551 Powers 1 in. (25mm) 6¼ in. (159mm) 6½ in. (165mm) 331-2976 Powers 2 3/8 in. (60mm) 12 1/8 in. (308mm) 9¼ in. (235mm) MK2-7121 Invensys 3 3/4 in. (95mm) 16½ in. (419mm) 10 in. (254mm) * For dampers 18 in. (457mm) or more in height these dimensions are 0 in. . Damper Sizing Information Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The following figures show maximum damper section size and assembly configurations for multi-section dampers. Double Section Single Section 50 in. (1270mm) 50 in. (1270mm) 50 in. (1270mm) 96 in. (2435mm 32 in. (813mm) 32 in. (813mm) Transitioned Damper Dimensions D*+ 2 in. (51mm) +T 64 in. (1626mm) When a fire/smoke damper is being used in conjunction with round or oval ductwork, the FSD-211 can be supplied in a factory sleeve with round or oval transitions on both ends of the sleeve. Dampers should be ordered to the duct dimensions. Drawings below show overall damper size. s W* + 2 in. (51mm)+T s W* + 2 in. (51mm)+T s D* + 2 in. (51mm)+T 32 in. (813mm) s H*+ 2 in. (51mm)+Ts 21/8 in. (54mm) 21/8 in. (54mm) H* H* + 2 in. (51mm)+T s 21/8 in. H* (54mm) W* 16 in. (406mm) Min. D* 100 in. (2540mm) 16 in. (406mm) Min. W* 16 in. (406mm) Min. TYPE O TYPE R TYPE C * These dimensions are furnished approximately 1/4 in. Specifications 50 in. (1270mm) (6mm) undersize, except round and oval dimensions which are approximately 1/8 in. (3mm) undersize. Ts = (2)(Sleeve Thickness) Combination Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the 32 in. (813mm) requirements of NFPA 80, 90A, 92A, 92B, 101 & 105 and further shall be tested, rated and labeled in accordance with the latest edition of UL Standards 555 and 555S. Dampers shall have a UL555 fire rating of 1½ hours and be of low leakage design qualified to UL 555S Leakage Class I. in. (2540mm) reinforced128 corners. Bearings shall be sintered bronze sleeve type rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tighter seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Each damper /actuator combination shall have a UL555S elevated temperature rating of 250°F (121°C) minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 120 (24 or 230) volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. The Damper Manufacturer's submittal data shall certify all air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3, and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Dampers shall be labeled with the AMCA Air Performance Seal. Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Damper frame shall be galvanized steel formed into a structural hat channel shape with Damper must be rated for mounting vertically (with blades running horizontal) or horizontally and be UL 555S rated for leakage and airflow in either direction through the damper. Each damper shall be supplied with a 165°F (74°C) RRL. The basis of design is Greenheck Model FSD-211. Copyright ©2006 Greenheck Fan Corporation FSD-211 Rev 3 June 2006
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-702 Create Date : 2008:10:22 13:58:49-05:00 Metadata Date : 2008:10:23 07:26:05-05:00 Modify Date : 2008:10:23 07:26:05-05:00 Creator Tool : Adobe InDesign CS3 (5.0.2) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 12699 bytes, use -b option to extract) Document ID : adobe:docid:indd:91e7bc79-7545-11d9-93db-c429e5670938 Instance ID : uuid:7f042baa-0753-4fd9-96ff-82d766aec274 Rendition Class : proof:pdf Derived From Instance ID : 9d72e99c-4f7a-11d9-900d-9418c3585b94 Derived From Document ID : adobe:docid:indd:793bbfe6-fcfe-11d8-8191-9f7f6af70d67 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:fbeb707c-2493-4293-9f67-21c97424b6d6, uuid:5B03DFB64301DB11A3F3B8612B38E6FD, uuid:a374011a-d222-4ad2-9c14-94abdfb7bb09, uuid:5D03DFB64301DB11A3F3B8612B38E6FD, uuid:b51217e1-3137-45d2-bfba-44f249182967, uuid:5F03DFB64301DB11A3F3B8612B38E6FD, uuid:0E16419FEC01DB11B064AB6CEAA2EA0D, uuid:6103DFB64301DB11A3F3B8612B38E6FD Manifest Reference Document ID : uuid:7a8c783c-d774-4284-ad1c-54bdb5f89853, uuid:6203DFB64301DB11A3F3B8612B38E6FD, uuid:7F4442ED6801DB11A3F3B8612B38E6FD Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 7 Creator : Adobe InDesign CS3 (5.0.2)EXIF Metadata provided by EXIF.tools