Greenheck Fan Series L Users Manual
Series L to the manual e4873b7f-9a50-435a-a334-7af102ee9f68
2015-02-09
: Greenheck-Fan Greenheck-Fan-Series-L-Users-Manual-562608 greenheck-fan-series-l-users-manual-562608 greenheck-fan pdf
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
Centrifugal Roof Exhaust Fans Series L Low Silhouette Louvered Penthouse Style LDP/LBP Fabra Hood Style LD/LB April 2008 Series L Centrifugal Roof Exhaust Fans Greenheck’s Series L, low silhouette, models LD, LB, LDP, and LBP centrifugal roof exhaust fans provide the industry’s best performance and durability for general clean air applications. • Broadest performance in the industry, up to 1.25 in. wg (311 Pa) and 37,500 cfm (63,713 m3/hr). • Performance as cataloged is assured. All fan sizes are tested in our AMCA Accredited Laboratory, and all models are licensed to bear the AMCA sound and air performance seals. • UL Listed for electrical.* • Greenheck subjects these products to extensive life testing, assuring you the fans will provide years of reliable performance. Greenheck Fan Corporation certifies the models LD, LDP, LB, and LBP shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. * UL is optional and must be specified. Models LD, LDP, LB, and LBP are listed for electrical (UL/cUL 705) File no. E40001. Leading Edge Technical Support When you need extensive product or installation and operating manual (IOM) information, our products are supported by the industry’s best product literature, electronic media and computer aided product selection (CAPS) program. You’ll also find this information on our website at www.greenheck.com You can always count on personal service and expertise from our national and international representative organization. To locate your nearest Greenheck representative, call 715-359-6171 or visit our website at www.greenheck.com Quick Build Programs Our Quick Build (QB) Program ensures rapid response time when your needs require a fast turnaround. Select from more than 40 configurations of the Series L, low silhouette model fan and we will manufacture and ship them within ten days. We have strategically located many warehouses across the United States and internationally to fill your request at a moments notice. World Class Manufacturing Greenheck’s skilled production workers use cost-effective machines and unique dies designed and built by our own engineers to add innovative features and greater strength to our centrifugal roof exhaust fans. Our advanced manufacturing processes and quality control procedures always ensure the highest product quality. And just to be sure you get the peace-of-mind you expect when you specify Greenheck, our assembly inspectors test run and monitor every fan before it leaves the factory. Results of these tests are kept in permanent records for future reference. 2 Unique Construction Features Fabra Hood Style Louvered Penthouse Style • Hinged Hood - All sizes feature a hood which may be hinged to provide quick access to the motor and drive assembly. Access may be gained by simply removing two of the four hood fasteners or all fasteners for complete removal. • Large Interior Dimensions - All sizes allow complete accessibility. Interior dimensions offer clearance for inspection, cleaning, or maintenance of the motor, wheel, belt(s), and drives. • Hinged Cover - All sizes feature an aluminum cover which may be hinged to provide quick access to the motor and drive assembly. Covers are fastened down with a quick release hood latch. • Large Interior Dimensions - All sizes allow complete accessibility from above. Interior dimensions offer clearance for inspection, cleaning, or maintenance of the motor, wheel, belt(s), and drives. • Strength & Weather Resistant - Each unit features storm resistant aluminum louver blades with mitered corners. For decades, our storm resistant blades have proven highly effective. Each sturdy extruded aluminum louver blade has a material thickness of 0.080 inches. • Strength & Weather Resistance - The hood is designed with arched panels manufactured of heavy gauge, precision roll formed steel with interlocking edges. Each interlocking rib creates a tight, weather resistant seal. Heavy gauge steel support members provide structural strength. The first hood was put into service over 30 years ago. Greenheck’s interlocking rib design combines four material thicknesses with I-beam design principles producing a hood far superior in strength to conventional designs (an important feature in high wind and snow load regions). Formed channels adjacent to the ribs provide water drainage to ensure weather tightness. Greenheck’s louvered penthouse hoods feature heavy gauge extruded aluminum louvers with mitered corners for a clean, finished appearance and weather resistant construction. The interior vertical edge of the curb cap forms the throat and weathershield. Each corner is also shielded to prevent leakage. Penthouses are available in aluminum for lasting durability and appearance. Hoods are available in galvanized steel, painted steel, or aluminum construction. 3 1 6 12 10 5 2 9 15 11 14 13 LB/LD FABRA HOOD STYLE 8 4 6 10 13 11 7 5 9 3 LBP/LDP LOUVERED PENTHOUSE STYLE 4 Unique Construction Features 1 FABRA HOOD STYLE - Models LD and LB have a rib-lock aluminum housing. Hood panels are interlocked and attached to sturdy aluminum rails. (Galvanized housings are optional). 2 HINGED ACCESS - The entire hood assembly on models LD and LB can be hinged open for access to the internal fan components. 3 LOUVERED PENTHOUSE - Models LDP and LBP penthouse style housings are constructed of heavy extruded aluminum louvers with mitered and welded corners. 4 HOOD COVER - Models LDP and LBP aluminum hood covers are hinged and removable for access. 5 DRIVE FRAME - Constructed from heavy gauge galvanized steel. Belt adjustment is accomplished by loosening fasteners, sliding the motor plate, and retightening fasteners. 6 FAN SHAFT - Precisely sized, ground, and polished so the first critical speed is at least 25% over the maximum operating speed. Close tolerances between the shaft and bearing result in longer bearing life. 7 BEARINGS - 100% factory tested and designed specifically for air handling applications with a minimum L10 life in excess of 100,000 hours (L50 average life of 500,000 hours). 8 CURB CAP - Curb cap has prepunched mounting holes to ensure correct attachment to the curb. 9 MOTOR - Permanently lubricated, sealed ball bearing motors are selected to provide years of trouble-free operation. 10 DRIVE ASSEMBLY - Drives are oversized 150% of driven horsepower. Machined cast iron pulleys are factory set to the required RPM and are adjustable for final system balancing. Belts are static free and oil resistant. 11 WHEEL - An aluminum, backward inclined, non-overloading, centrifugal wheel is utilized to deliver maximum efficiency. Each wheel is statically and dynamically balanced. 12 VIBRATION ISOLATORS - Support the drive assembly and wheel without steel to steel contact providing long life and quiet operation. 13 BIRDSCREEN - Galvanized rigid wire protects the fan’s discharge from birds or small objects. (Aluminum birdscreen is optional). 14 WINDBAND - Lower windband assembly ensures weathertight and rigid unit construction. 15 DISCONNECT SWITCH - NEMA-1 switch is factory mounted and wiring is provided from the motor to the disconnect enclosure as standard. All wiring and electrical components comply with the National Electric Codes (NEC) and are UL Listed or Recognized. 16 CONDUIT CHASE - A large diameter conduit for installing electrical wiring through the curb cap into the motor compartment. (Not shown) STANDARD INSTALLATION Models LB, LD, LBP, and LDP exhaust fans are designed to meet the needs of general clean air applications. Tests have been conducted to ensure safe and reliable fans capable of withstanding normal exhaust conditions. When roofing materials extend to the top of the curb, roof curbs should be 11⁄2 in. (38 mm) (3/4 in. (19 mm) on a side) less than the unit curb cap to allow for roofing and flashing. For recommended duct size, damper size, and roof opening dimensions, refer to CAPS or the performance data pages. 8 to 12 in. (203 to 305 mm) 3/4 in. (19 mm) Installation must include a means for inspecting, cleaning, and servicing the exhaust fan. Due to the varying airstreams encountered in commercial ventilation, system designers must be aware of national, state, and local codes and guidelines governing these installations. Local code authorities should be consulted before proceeding with any ventilation project. Damper 1 1/4 in. (32 mm) Recommended Duct and Damper Size 1 1/4 in. (32 mm) Recommended Roof Opening 5 Options and Accessories BIRDSCREEN - Galvanized mesh is standard. Optional aluminum or stainless steel rigid wire are also available. HOOD INSULATION - Hood insulation is dualdensity to minimize condensation, reduce thermal transfer, and enhance sound absorption at high and low frequencies. LIFTING LUGS - Four heavy gauge steel brackets are available to provide lifting points when raising the fan to the roof. Tie Down Points - Four heavy gauge steel brackets are available to secure the fan in heavy wind applications. Cables and anchors by others. COATINGS - All Greenheck coatings and resistance charts can be found in the performance coatings catalog. A wide variety of coatings and colors are available in two categories: Decorative coatings – Sixteen standard colors are available. Protective coatings – Five electrostatic applied powder coatings are available to protect against most environments. DAMPERS - Designed to prevent outside air from entering back into the building when fan is off. Options include gravity and motorized dampers. Damper sizes are shown on each performance data page. CURB SEAL - Rubber seal between fan and curb to ensure proper sealing when attached to a curb. 6 DISCONNECT SWITCHES - A wide selection of NEMA rated switches are available for positive electrical shutoff and safety, including: dust-tight, rainproof, and corrosion-resistant. Switches may be internally or externally mounted. SPEED CONTROLLERS - Available for use with shaded pole and permanent split capacitor (PSC) open motors on models LD and LDP fans. They provide an economical means of system balancing with direct drive fans. CURB EXTENSIONS - Extensions raise the fan discharge above the roof line and provide an accessible mounting location for dampers. Insect screen bases constructed with a removable fine mesh are recommended for applications where insect entry must be prevented. Curb extensions are not available with LDP and LBP severe duty construction models. ROOF CURBS - Prefabricated roof curbs reduce installation time and costs by ensuring compatibility between the fan, curb, and roof opening. All curbs are insulated with fiberglass. A wide variety of roof curbs are available including flanged, pitched, and sound-absorbing. Severe Duty Option SEVERE DUTY - Specifically designed for applications with extremely high structural design load requirements. The severe duty models LDP and LBP are far superior to any centrifugal roof exhaust fan currently in the market. Designed with structural steel supports and ESD-603D louver blades, the severe duty louver enclosure (SDLE) may be used in any application which requires a fan to endure high winds with the potential of wind blown debris. The louvered housing has been tested in accordance with the following Miami-Dade test protocols: • Large Missile Impact Test - TAS-201-94 • Uniform Static Air Pressure - TAS-202-94 • Uniform Cyclic Wind Loading - TAS-203-94 To meet the above protocols, the severe duty fan must be mounted on a severe duty roof curb, which is attached directly to the building NOTICE OF ACCEPTANCE NUMBER 03-0422.05 structure. Maximum design load is 140 psf. Available on sizes • LDP - 60 though 120 • LBP - 10 through 30 Weights and dimensions will vary from standard LDP and LBP construction. Severe Duty Installation Models LDP and LBP severe duty exhaust fans are designed to meet the needs of general clean air applications. Tests have been conducted to ensure safe, rugged and reliable fans capable of withstanding severe exhaust conditions. The severe duty roof curb model SD is supplied with this product and is designed with 12 gauge welded steel construction. Greenheck recommends the severe duty curb to be anchored to the structure of the building. Dependent upon roofing material it shall be bolted and welded. For recommended duct size, refer to CAPS or installation manual. Installation must include a means for inspecting, cleaning, and servicing the exhaust fan. Due to the varying airstreams encountered in commercial ventilation, system designers must be aware of national, state, and local codes and guidelines governing these installations. Local code authorities should be consulted before proceeding with any ventilation project. 3/4 INCH (19 MM) THROAT DIMENSION (ROOF OPENING) 1 3/4 INCH (44 MM) 1 3/4 INCH (44 MM) OUTSIDE CURB DIMENSION 12, 18 OR 24 INCHES (305, 457, 610 MM) 1 INCH (25 MM) INSULATION 4 IN. (102 MM) ROOF OPENING 4 IN. (102 MM) CORRUGATED ROOF DECK CONCRETE ROOF TRUSS RECOMMENDED DUCT & DAMPER SIZE 1 1/4 INCH (32 MM) 2 1/2 INCH (64 MM) 4 INCH (102 MM) 6 INCH x 3 INCH (152 MM x 76 MM) STEEL MOUNTING ANGLE (12 GAUGE MINIMUM) 1 3/4 INCH (44 MM) 2 1/2 INCH (64 MM) 4 INCH (102 MM) 7 Severe Duty Dimensions LDP - SEVERE DUTY DIMENSIONS B C D E A A LBP - SEVERE DUTY DIMENSIONS C B D E A Model Number LDP 60 65 70 75 80 85 90 95 100 120 A B A C D E Damper Size (square) Roof Opening (square) Weight* 17 347⁄8 347⁄8 175⁄8 13⁄4 8 101⁄2 375 (432) (886) (886) (448) (44) (203) (267) (170) 19 367⁄8 367⁄8 175⁄8 13⁄4 10 121⁄2 400 (483) (934) (934) (448) (44) (254) (318) (181) 22 397⁄8 397⁄8 195⁄8 13⁄4 12 141⁄2 425 (559) (1013) (1013) (498) (44) (305) (368) (193) 10 22 397⁄8 503⁄8 181⁄8 13⁄4 12 101⁄2 550 (559) (1013) (1280) (460) (44) (305) (267) (249) 14 26 437⁄8 517⁄8 181⁄8 13⁄4 16 101⁄2 550 (660) (1114) (1318) (460) (44) (406) (267) (249) 101⁄2 550 30 477⁄8 577⁄8 245⁄8 13⁄4 18 (267) (249) (762) (1216) (1470) (625) (44) (457) 10 ⁄2 700 (267) (318) 18 LBP 21 1 24 34 517⁄8 617⁄8 245⁄8 13⁄4 24 101⁄2 800 (864) (1318) (1572) (625) (44) (610) (267) (363) 30 40 577⁄8 697⁄8 271⁄4 13⁄4 30 101⁄2 950 (1016) (1470) (1775) (692) (44) (762) (267) (431) Cover Thickness Louver Thickness Curb Cap Thickness 0.100 0.125 0.25 (0.045) (0.056) (0.113) aluminum aluminum steel 0.100 0.125 0.25 (0.045) (0.056) (0.113) aluminum aluminum steel All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. 8 Severe Duty Curb Installation Options OUTSIDE CURB DIMENSION THROAT DIMENSION (ROOF OPENING) 1.75 INCH (44 MM) 1.75 INCH (44 MM) Concrete CURB HEIGHT 12, 18, OR 24 INCHES (305, 457, or 610 MM) 1 INCH (25 MM) INSULATION HILTI KB11, 3/8-16 X 3 ON 12 INCH (305 MM) MAXIMUM CENTERS. MINIMUM TWO PER SIDE. ROOF OPENING 2.5 INCH (57 MM) EMBEDMENT MINIMUM CONCRETE STRENGTH OF 3000 PSI 2.25 INCH (57 MM) TYPICAL 1.75 INCH (44 MM) 4 INCH (102 MM) MOUNTING FLANGE TYPICAL 4 INCH (102 MM) TYPICAL OUTSIDE FLANGE DIMENSION THROAT DIMENSION AND ROOF OPENING EQUAL OUTSIDE CURB DIMENSION MINUS 3.5 INCHES (89 MM) OUTSIDE CURB DIMENSION THROAT DIMENSION (ROOF OPENING) 1.75 INCH (44 MM) Steel CURB HEIGHT 12, 18, OR 24 INCHES (305, 457, 610 MM) 1.75 INCH (44 MM) CORNER TOP VIEW 1 INCH (25 MM) INSULATION HILTI KWIK-FLEX 12-14 SCREW, NO. 3 POINT. THREE (3) FASTENERS EACH CORNER AND MAXIMUM OF 4.5 INCHES (114 mm) SPACING; ADD ADDITIONAL FASTENERS TO SATISFY. 4 INCH (102 MM) MOUNTING FLANGE TYPICAL ROOF OPENING CORRUGATED ROOF DECK 6 X 3 INCH (152 x 76 mm) STEEL MOUNTING ANGLE (12 GAUGE MINIMUM) ROOF TRUSS 1.75 INCH (44 MM) 2.25 INCH (57 MM) TYPICAL 4 INCH (102 MM) TYPICAL OUTSIDE FLANGE DIMENSION THROAT DIMENSION AND ROOF OPENING EQUAL OUTSIDE CURB DIMENSION MINUS 3.5 INCHES (89 MM) Model Number Code The Model number system is designed to completely identify the fan. The correct code letters must be specified to designate belt or direct drive. The remainder of the model number is determined by the size and performance selected from the following pages. LB - 30 - 7 Model LD - Fabra Hood Direct Drive LB - Fabra Hood Belt Drive LDP - Louvered Penthouse Direct Drive LBP - Louvered Penthouse Belt Drive Fan Size LD/LDP 60 thru 120 LB/LBP 10 thru 54 Motor hp (Belt Drive only) 6 = 1/6 10 = 1 50 = 5 75 = 71⁄2 4 = 1/4 15 = 11⁄2 3 = 1/3 20 = 2 100 = 10 5 = 1/2 30 = 3 150 = 15 7 = 3/4 Motor RPM A = 1725 B = 1140 C = 860 (Direct Drive only) 9 LD/LDP 60-75 Direct Drive LD Dimensions 131⁄2 (559) Size 60 and 65 0.6 27 Static Pressure Pa 13 (44) 0.5 120 (330) 13⁄4 RPM Density 0.075 lb/ft3 140 (686) (343) 2 17 17 (432) (432) (51) 100 80 60 40 Static Pressure in. wg 22 LD /L 0.3 23 111⁄2 -6 5 /L DP -6 0 0.2 0 0.0 0 50 100 150 200 250 300 cfm 23 (584) DP LD 0.1 20 LDP Dimensions 0.4 0 (584) 50 100 150 200 250 300 350 400 450 500 3 m /hr (292) Size 70 and 75 131⁄2 0.6 RPM Density 0.075 lb/ft3 140 (343) 0.5 17 17 (432) (432) LD 60 thru LD 75 LDP 60 thru LDP 75 Hood Thickness 24 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 8 (203) 8 (203) Roof Opening Square 101⁄2 (267) 101⁄2 (267) Weight* Galvanized, 37 (17) Aluminum, 49 (22) 100 80 60 40 20 0 Static Pressure in. wg 1 ⁄4 (44) Static Pressure Pa 120 3 LD 0.4 /L DP -7 0 0.3 LD/LDP-60 Motor HP 1/60 Fan RPM 1590* -7 5 0.2 0.1 0.0 0 50 100 150 200 LD/LDP-65 1/30 1680* 70 W LD/LDP-70 1/30 1665* 73 W LD/LDP-75 1/25 1620* 79 W 250 300 350 400 cfm 0 100 200 300 400 500 600 3 m /hr CFM / Static Pressure in Inches wg Watts 51 W /L DP All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LDP dimensions. Model Number LD CFM 0 0.1 0.125 0.2 0.25 0.3 202 171 164 139 119 97 0.375 0.4 Sones 4.8 4.3 4.3 4.0 3.8 3.6 CFM 274 245 238 208 187 165 129 112 Sones 5.6 5.3 5.2 5.0 5.1 5.1 5.1 5.2 0.45 0.5 CFM 360 324 314 282 257 231 188 171 132 Sones 6.4 6.0 5.9 5.5 5.4 5.3 5.2 5.1 5.0 CFM 400 360 351 317 290 264 222 206 168 122 Sones 5.8 5.2 5.1 4.9 4.7 4.5 4.2 4.1 4.0 3.8 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 10 LD/LDP 80-95 Direct Drive LD Dimensions Size 80 and 85 0.7 27 131⁄2 0.6 (343) Static Pressure Pa 140 16 (406) 13⁄4 (44) RPM Density 0.075 lb/ft3 160 (686) 4 19 19 (483) (483) (102) 120 100 80 60 Static Pressure in. wg 28 (711) 0.5 -8 0 LD /L DP -8 5 0.2 0.0 0 100 200 300 400 500 600 cfm 25 (635) DP 0.3 0.1 0 LDP Dimensions 121⁄2 /L 40 20 25 LD 0.4 0 200 400 600 (635) 800 1000 3 m /hr (318) Size 90 and 95 161⁄2 220 0.9 (419) 200 0.8 180 19 (483) (483) Hood Thickness Cover Thickness Louver Thickness Curb Cap Thickness Damper Size Square Roof Opening Square Weight* LD 80 thru LD 95 LDP 80 thru LDP 95 24 ga 0.064 (0.029) 0.081 (0.036) 0.064 (0.029) 0.064 (0.029) 10 (254) 10 (254) 1 12 ⁄2 (318) 121⁄2 (318) Galvanized, 45 (20) Aluminum, 63 (29) 140 120 100 80 60 0.7 Static Pressure in. wg (44) 160 19 Static Pressure Pa 1 ⁄4 3 RPM Density 0.075 lb/ft3 0.6 LD 0.5 /L DP LD 0.4 LD/LDP-80 Motor HP 1/20 Fan RPM 1550* -9 0.3 0 0.2 40 0.1 20 0 0.0 0 200 400 600 LD/LDP-85 1/20 1500* 120 W LD/LDP-90 1/15 1550* 92 W LD/LDP-95 1/8 1550* 160 W 800 1000 1200 cfm 0 200 400 600 800 1000 1200 1400 1600 1800 2000 3 m /hr CFM / Static Pressure in Inches wg Watts 115 W 5 DP All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LDP dimensions. Model Number -9 /L CFM 0 0.1 0.125 0.2 0.25 0.3 0.375 0.5 481 426 413 372 342 310 258 165 Sones 8.8 8.2 8.0 7.8 7.6 7.4 7.2 7.5 CFM 576 507 490 440 403 360 291 182 Sones 8.6 8.1 8.0 7.7 7.3 7.1 7.0 7.8 CFM 819 735 714 654 608 562 485 361 0.6 0.625 Sones 8.8 8.6 8.5 8.4 8.3 8.1 7.8 7.9 CFM 1052 965 942 870 825 780 695 552 430 396 Sones 11.8 11.2 11.1 10.8 10.4 10.2 10.0 9.8 10.1 10.2 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 11 LD/LDP 100-120 Direct Drive LD Dimensions 250 (686) (44) 22 (559) (559) 4 (102) 100 50 S YS TEM TO FT H IS 0.7 0.6 0.4 0.3 0.2 0.1 0 LDP Dimensions 0.0 0 14 (711) 11 40 86 DO 0 NO 200 400 600 800 1000 1200 1400 1600 cfm 28 28 25 LEF 0.5 17 TH E 22 150 TO (457) 0.8 SE LE CT Static Pressure Pa 18 Static Pressure in. wg 0.9 200 13⁄4 1.0 (343) RPM Density 0.075 lb/ft3 CUR VE 131⁄2 (762) Size 100 1.1 27 T 30 0 500 1000 1500 (711) 2000 2500 3 m /hr (356) Size 120 1.2 URV E 181⁄2 100 F TH TO 0.4 0.2 0 Motor HP Fan RPM LD/LDP-100-C 1/8 860 LD/LDP-100-B 1/6 1140 LD/LDP-100-A 1/4 1725 LD/LDP-120-C 1/8 860 LD/LDP-120-B 1/6 1140 LD/LDP-120-A 1/4 1725 25 40 0.0 0 86 0 DO 200 400 600 800 1000 1200 1400 1600 1800 2000 cfm 0 500 1000 1500 2000 2500 3000 3 All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LDP dimensions. Model Number 17 11 N OT 50 0.6 L EF 150 0.8 HE LD 100 thru LD 120 LDP 100 thru LDP 120 Hood Thickness 24 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 12 (305) 12 (305) 1 Roof Opening Square 14 ⁄2 (368) 141⁄2 (368) Weight* Galvanized, 57 (26) Aluminum, 82 (37) 200 CT TO T 22 (559) RPM Density 0.075 lb/ft3 SE LE 22 (559) 1.0 Static Pressure in. wg 13⁄4 (44) Static Pressure Pa 250 IS S YST EM C (470) m /hr CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 766 0.022 6.3 1016 0.051 12.0 1538 0.18 16.2 0.125 568 0.029 5.3 879 0.065 11.0 1457 0.21 14.8 0.2 407 0.028 5.1 780 0.068 10.6 1399 0.22 14.4 CFM BHP Sones CFM BHP Sones CFM BHP Sones 921 0.03 6.6 1221 0.071 11.9 1848 0.25 21 702 0.041 5.3 1072 0.086 10.9 1762 0.28 19.6 536 0.043 5.1 960 0.094 10.3 1693 0.29 19.4 CFM / Static Pressure in Inches wg 0.25 0.375 0.5 0.625 0.75 0.875 0.9 709 0.068 10.4 1360 0.22 14.2 493 0.066 10.4 1256 0.23 14.3 1142 0.24 14.2 1024 0.24 14.8 891 0.23 15.3 724 0.23 15.9 678 0.22 16.1 886 0.096 10.0 1652 0.29 19.3 664 0.099 9.2 1540 0.31 18.6 1412 0.33 18.4 1286 0.34 18.2 1142 0.35 18.2 979 0.34 18.3 940 0.33 18.3 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 12 LB/LBP 10 Belt Drive LB Dimensions 17 ⁄4 (711) 1.4 50 SY ST EM OF TH IS LE FT 0.2 0 LBP Dimensions T NO 10 SE 67 83 60 3 0 200 400 600 0 500 800 1000 (978) 1000 1200 1400 1600 1500 2000 2500 3 m /hr (356) (432) 22 13⁄4 34 00 cfm 17 325⁄8 (559) (44) 0.0 0 381⁄2 (711) 15 13 TH 0.4 DO 14 67 E 0.6 (559) 28 17 TO (85) 100 0.8 T (559) 22 150 1.0 LE C (44) 31⁄4 Static Pressure in. wg Static Pressure Pa (432) 22 1.2 (438) 200 RPM HP Density 0.075 lb/ft3 p p 300 250 1 ⁄4 3h 4h (991) 17 3 1/ 1/ 39 1 CU RV E 28 (829) LB-10 LBP-10 Hood Thickness 22 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 12 (305) 12 (305) Roof Opening Square 141⁄2 (368) 141⁄2 (368) Galvanized, Aluminum, Weight* 99 (45) 56 (25) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 600 712 937 1049 LB/LBP-10-4 1/4 1162 1274 1386 1499 1611 1689 LB/LBP-10-3 1/3 1767 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 539 0.013 3.0 639 0.021 3.6 841 0.048 5.1 942 0.067 5.9 1043 0.091 6.9 1144 0.12 8.0 1244 0.15 9.2 1346 0.19 10.0 1446 0.24 11.2 1516 0.28 12.2 1587 0.32 13.5 0.125 351 0.014 1.6 500 0.024 2.3 746 0.053 4.3 855 0.073 5.3 963 0.097 6.3 1070 0.13 7.5 1177 0.16 8.8 1283 0.2 9.8 1388 0.25 10.9 1461 0.29 11.9 1533 0.33 13.0 0.25 CFM / Static Pressure in Inches wg 0.375 0.5 0.625 0.75 0.875 1 1.125 MAX. BHP AT A GIVEN RPM - (rpm/2476)3 MAXIMUM FRPM = 1767 TIP SPEED = rpm x 2.913 MAX. MOTOR FRAME SIZE = 56 623 0.054 3.6 759 0.076 4.7 887 0.103 5.9 1004 0.13 7.1 1114 0.17 8.4 1224 0.21 9.5 1331 0.26 10.7 1406 0.3 11.6 1480 0.34 12.6 625 0.075 4.2 780 0.103 5.4 917 0.14 6.8 1047 0.18 8.2 1168 0.22 9.3 1280 0.27 10.4 1356 0.31 11.3 1432 0.35 12.2 618 0.099 4.7 818 0.14 6.3 953 0.18 7.9 1093 0.22 8.8 1220 0.28 10.1 1304 0.32 11.0 1385 0.36 11.9 861 0.17 7.3 1006 0.22 8.3 1142 0.28 9.5 1237 0.32 10.6 1327 0.36 11.7 910 0.22 7.8 1064 0.28 9.0 1158 0.32 9.9 1254 0.36 11.0 970 0.27 8.5 1087 0.32 9.5 1182 0.36 10.5 980 0.31 8.9 1112 0.36 10.1 997 0.36 9.5 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 13 LB/LBP 14 Belt Drive LB Dimensions OF TH IS EF T EL 0.2 0 0.0 0 (813) TH TO 0 900 1200 1500 1800 2100 2400 2700 1000 2000 3000 4000 3 m /hr (406) 17 26 13⁄4 600 (1016) (432) 26 (660) (44) 0 16 300 cfm 40 32 N 48 DO 2 O T 50 LBP Dimensions 43 0.4 65 (660) 70 (660) 100 (102) 5 (44) 4 26 0.6 RPM HP Density 0.075 lb/ft3 hp 7 26 2 82 13⁄4 150 hp 0.8 1/ 11 (457) 200 hp 13 18 4 99 Static Pressure Pa (445) 1/ 1.0 URV E 3 250 S YS TEM C 1/ (991) SE LE CT 17 ⁄2 (889) 1.2 39 1 Static Pressure in. wg 35 (660) LB-14 Hood Thickness 22 ga Cover Thickness Louver Thickness Curb Cap Thickness 0.064 (0.029) Damper Size Square 16 (406) Roof Opening Square 181⁄2 (470) Galvanized, Weight* 81 (37) LBP-14 0.064 (0.029) 0.081 (0.036) 0.064 (0.029) 16 (406) 181⁄2 (470) Aluminum, 116 (53) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 480 564 731 LB/LBP-14-4 1/4 815 899 982 1066 1118 LB/LBP-14-3 1/3 1170 1257 LB/LBP-14-5 1/2 1343 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 903 0.022 4.1 1061 0.035 4.7 1375 0.077 5.9 1533 0.11 6.7 1690 0.14 7.5 1847 0.19 8.5 2004 0.24 9.8 2102 0.27 10.7 2200 0.31 11.5 2364 0.39 12.9 2525 0.47 14.4 0.125 614 0.025 3.2 848 0.041 4.2 1231 0.086 5.6 1402 0.12 6.4 1574 0.15 7.3 1743 0.2 8.4 1912 0.25 9.7 2016 0.28 10.6 2120 0.32 11.3 2290 0.4 12.7 2456 0.49 14.1 0.25 CFM / Static Pressure in Inches wg 0.375 0.5 0.625 0.75 0.875 1 1.125 MAX. BHP AT A GIVEN RPM - (rpm/1639)3 MAXIMUM FRPM = 1343 TIP SPEED = rpm x 3.829 MAX. MOTOR FRAME SIZE = 56 1024 0.089 5.1 1241 0.12 5.9 1439 0.16 6.9 1629 0.21 8 1807 0.26 9.4 1913 0.3 10.3 2019 0.34 11.1 2197 0.42 12.5 2372 0.51 13.8 1013 0.12 5.4 1264 0.17 6.4 1482 0.21 7.5 1681 0.27 8.9 1801 0.31 9.8 1920 0.36 10.6 2112 0.44 12.1 2289 0.53 13.5 946 0.15 5.7 1297 0.21 7 1534 0.28 8.4 1672 0.32 9.3 1797 0.36 10.1 2002 0.44 11.6 2199 0.54 13.1 1351 0.27 7.8 1512 0.32 8.7 1657 0.36 9.5 1887 0.45 11.1 2092 0.55 12.6 1257 0.3 8.1 1487 0.36 9.0 1748 0.45 10.5 1979 0.55 12.2 1585 0.44 10.1 1848 0.55 11.6 1692 0.54 11.1 1386 0.51 10.4 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 14 LB/LBP 18 Belt Drive LB Dimensions (445) 30 (44) 30 (762) (762) 200 (114) 1/ 1.5 3 1/ 4 1.0 1/ 2 hp LBP Dimensions 19 (914) 14 60 12 61 10 62 86 66 46 4 N 5 1000 2000 3000 4000 5000 6000 cfm 46 36 DO hp 3 OT 0.0 0 0 2 RPM HP Density 0.075 lb/ft3 hp hp hp 0.5 1/ OT HE LEF TO F TH IS S 1 ⁄4 3 Static Pressure in. wg 4 ⁄2 1 hp (533) 400 hp 4 21 1 3/ Static Pressure Pa 2.0 2 1 YST EM (991) TT (1016) CUR VE 17 ⁄2 2.5 600 39 1 SE LE C 40 0 2 4 (1168) 6 8 10 3 m /hr X 1000 (483) 241⁄2 (622) 30 13⁄4 30 (762) (44) (762) LB-18 LBP-18 Hood Thickness 22 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 18 (457) 18 (457) Roof Opening Square 201⁄2 (521) 201⁄2 (521) Galvanized, Aluminum, Weight* 179 (81) 135 (61) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 465 LB/LBP-18-4 1/4 562 755 LB/LBP-18-3 1/3 826 888 LB/LBP-18-5 1/2 949 LB/LBP-18-7 3/4 1085 LB/LBP-18-10 1 1141 1286 LB/LBP-18-15 11⁄2 1375 LB/LBP-18-20 2 1460 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 1753 0.056 3.6 2119 0.099 4.9 2847 0.24 8.7 3115 0.31 10.2 3348 0.39 11.7 3578 0.48 13.4 4091 0.71 16.8 4302 0.83 18.0 4849 1.19 21 5185 1.45 24 5505 1.73 26 0.125 1422 0.064 2.7 1871 0.108 4.1 2671 0.25 7.9 2957 0.33 9.5 3203 0.4 11.0 3442 0.49 13.0 3972 0.73 16.2 4189 0.84 17.3 4749 1.2 20 5091 1.47 23 5417 1.76 25 0.25 1522 0.114 3.4 2474 0.27 7.4 2778 0.34 8.9 3039 0.42 10.4 3292 0.51 12.0 3847 0.75 15.5 4073 0.86 16.7 4648 1.22 19.8 4997 1.49 22 5328 1.78 24 CFM / Static Pressure in Inches wg 0.5 0.75 1 1.25 1.5 1.75 2 MAX. BHP AT A GIVEN RPM - (rpm/1157)3 MAXIMUM FRPM = 1460 TIP SPEED = rpm x 4.843 MAX. MOTOR FRAME SIZE = 145T 1925 0.27 6.5 2324 0.36 8.0 2638 0.45 9.4 2936 0.54 11.0 3575 0.79 14.6 3814 0.91 15.9 4423 1.27 19.2 4790 1.54 21 5138 1.83 23 2110 0.44 8.7 2498 0.55 10.3 3218 0.82 13.4 3493 0.94 14.8 4183 1.32 18.5 4576 1.59 21 4936 1.88 23 2822 0.82 12.9 3140 0.96 14.1 3880 1.35 17.8 4311 1.63 20 4714 1.93 22 2674 0.93 13.8 3568 1.37 17.4 4025 1.66 19.9 4446 1.98 22 3208 1.35 17.1 3719 1.67 19.6 4176 2 22 3382 1.65 19.5 3874 2 22 3538 1.97 22 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 15 LB/LBP 21 Belt Drive LB Dimensions E TO 00 FT 12 LEF 53 10 HE CT TO T 6 LE 9 75 SE OT 2 5 N 1000 2000 3000 46 0 2 4 4000 5000 6000 7000 8000 6 8 10 12 3 (1168) m /hr X 1000 (483) (622) 30 13⁄4 DO cfm 241⁄2 30 (762) (44) 0.0 0 0 46 19 61 36 90 0.5 100 LBP Dimensions (914) HIS S hp Static Pressure in. wg 4 hp Static Pressure Pa 3/ 4 hp 1/ 3 (152) 1.0 1/ 6 30 (762) hp 30 (762) 200 2 13⁄4 300 1.5 1/ 23 hp 400 hp hp 1 (584) RPM HP Density 0.075 lb/ft3 2 2 (1295) (584) (44) YST EM CUR V 1/ 23 (1092) 2.0 51 1 43 (762) LB-21 LBP-21 Hood Thickness 22 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 18 (457) 18 (457) Roof Opening Square 201⁄2 (521) 201⁄2 (521) Galvanized, Aluminum, Weight* 191 (86) 145 (66) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 465 LB/LBP-21-4 1/4 595 LB/LBP-21-3 1/3 651 699 LB/LBP-21-5 1/2 747 801 LB/LBP-21-7 3/4 855 LB/LBP-21-10 1 899 1010 LB/LBP-21-15 11⁄2 1077 LB/LBP-21-20 2 1200 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 2820 0.12 6.6 3609 0.24 8.8 3948 0.32 10.1 4239 0.39 11.6 4531 0.48 13.4 4858 0.59 15.5 5186 0.72 16.7 5452 0.83 17.1 6126 1.18 20 6532 1.43 22 7278 1.98 26 0.25 1732 0.13 5.2 2938 0.28 7.8 3371 0.36 8.8 3724 0.44 9.9 4056 0.53 11.2 4424 0.65 12.9 4790 0.79 14.4 5087 0.91 15.4 5826 1.26 18.9 6260 1.52 21 7034 2.07 25 0.375 2457 0.28 6.9 2970 0.36 8.2 3362 0.45 9.3 3741 0.54 10.4 4157 0.66 11.8 4553 0.8 13.3 4858 0.93 14.5 5614 1.3 18.1 6068 1.56 20 6890 2.12 25 CFM / Static Pressure in Inches wg 0.5 0.625 0.75 1 1.25 1.5 1.75 MAX. BHP AT A GIVEN RPM - (rpm/910)3 MAXIMUM FRPM = 1200 TIP SPEED = rpm x 5.596 MAX. MOTOR FRAME SIZE = 145T 2354 0.34 6.9 2954 0.45 8.6 3390 0.55 9.8 3833 0.67 11.3 4261 0.81 12.8 4602 0.94 13.9 5415 1.32 17.3 5877 1.59 19.4 6712 2.18 24 1964 0.38 7.1 2909 0.53 9.1 3491 0.68 10.8 3954 0.82 12.1 4313 0.95 13.4 5183 1.34 16.6 5691 1.61 18.8 6542 2.2 23 2937 0.64 10.1 3608 0.82 11.5 4019 0.96 12.7 4926 1.35 16.2 5451 1.62 18.2 6375 2.22 23 2894 0.86 11.7 4386 1.36 15.0 4965 1.65 17.3 5954 2.25 22 3369 1.24 14.0 4395 1.63 16.4 5517 2.28 21 5013 2.26 20 4122 2.11 18.5 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 16 LB/LBP 24 Belt Drive LB Dimensions 1.6 23 ⁄2 1 (597) 34 (44) 34 (864) (864) 63⁄4 200 150 100 (171) 2 0.8 1/ 4 1/ 3 hp 20 (1016) hp hp 0.6 0.4 0.2 0 0.0 0 T NO 1000 CU RVE RPM HP Density 0.075 lb/ft3 hp 91 0 79 9 68 8 57 7 46 6 S 35 5 2000 3000 491⁄2 0 2 4 4000 5000 6000 7000 8000 9000 6 8 10 12 14 3 m /hr X 1000 (1257) (508) (597) 34 13⁄4 4 2 cfm 231⁄2 34 (864) (44) 3/ hp hp YS TEM 1/ 1.0 DO 40 2 1.2 50 LBP Dimensions 1/ hp EL 13⁄4 250 1 EF TO Static Pressure Pa 300 1 1.4 TH EL (521) 350 TO (1156) (1295) EC T 20 ⁄2 Static Pressure in. wg 45 ⁄2 1 FT HIS S 51 1 (864) LB-24 LBP-24 Hood Thickness 22 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 24 (610) 24 (610) Roof Opening Square 261⁄2 (673) 261⁄2 (673) Galvanized, Aluminum, Weight* 239 (108) 188 (85) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 355 LB/LBP-24-4 1/4 409 462 LB/LBP-24-3 1/3 508 LB/LBP-24-5 1/2 582 625 LB/LBP-24-7 3/4 667 LB/LBP-24-10 1 734 LB/LBP-24-15 11⁄2 787 868 LB/LBP-24-20 2 910 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 3419 0.11 5.8 3938 0.17 6.3 4449 0.24 7.4 4892 0.32 8.5 5604 0.48 10.7 6018 0.59 12.4 6423 0.72 14.1 7068 0.96 17.0 7578 1.18 19.6 8358 1.58 24 8763 1.82 27 0.25 2715 0.19 5.1 3451 0.28 6.3 4043 0.36 7.4 4917 0.54 9.4 5381 0.66 11.0 5828 0.8 12.7 6531 1.05 15.3 7080 1.29 17.4 7907 1.7 21 8333 1.95 24 0.375 CFM / Static Pressure in Inches wg 0.5 0.625 0.75 0.875 1 1.25 1.375 MAX. BHP AT A GIVEN RPM - (rpm/710)3 MAXIMUM FRPM = 910 TIP SPEED = rpm x 6.414 MAX. MOTOR FRAME SIZE = 145T 2491 0.25 5.3 3433 0.36 6.8 4441 0.55 8.9 4988 0.68 10.3 5505 0.82 12.0 6252 1.08 14.6 6820 1.32 16.5 7675 1.74 20 8114 2 23 3899 0.55 8.4 4497 0.68 10.0 5062 0.83 11.5 5912 1.1 13.9 6560 1.35 15.9 7440 1.78 19.4 7889 2.04 21 3929 0.66 9.5 4589 0.83 11.1 5503 1.1 13.5 6190 1.36 15.4 7192 1.81 18.9 7664 2.07 21 3984 0.79 10.9 5073 1.1 13.2 5799 1.36 15.0 6855 1.82 18.3 7377 2.09 20 4555 1.07 12.9 5398 1.36 14.8 6505 1.83 17.9 7056 2.1 19.8 4909 1.32 14.1 6141 1.82 17.6 6713 2.1 19.5 5285 1.76 16.0 5995 2.08 18.4 5537 2.03 17.2 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 17 LB/LBP 30 Belt Drive LB Dimensions 2.0 hp SY STE M HIS FT TO TH CT TO SE LE 6 40 8 10 12 14 16 5 10 15 20 25 3 m /hr X 1000 (673) (1016) 5 0 0 (1473) 261⁄2 13⁄4 83 4 3 2 1 4 (584) (44) 71 59 35 23 2 cfm X 1000 58 46 (1168) T 23 0.0 0 NO RPM HP Density 0.075 lb/ft3 47 hp DO 0 hp Static Pressure in. wg 2 1/ 3 1/ Static Pressure Pa 1 hp 0.5 100 LBP Dimensions hp 2 1/ (1016) 1.0 4 3/ (1016) (216) hp 40 200 1.5 1 (44) 81⁄2 40 300 hp 26 ⁄8 (676) 2 400 EL EF (749) 5 13⁄4 CU RVE 3 (1270) (1600) hp 291⁄2 5 63 50 40 (1016) LB-30 LBP-30 Hood Thickness 22 ga Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 30 (762) 30 (762) Roof Opening Square 321⁄2 (826) 321⁄2 (826) Galvanized, Aluminum, Weight* 318 (144) 249 (113) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 230 LB/LBP-30-3 1/3 366 394 LB/LBP-30-5 1/2 421 LB/LBP-30-7 3/4 483 LB/LBP-30-10 1 529 567 LB/LBP-30-15 11⁄2 605 LB/LBP-30-20 2 667 LB/LBP-30-30 3 703 LB/LBP-30-50 5 835 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 3910 0.076 8.0 6221 0.31 8.7 6697 0.38 9.0 7156 0.47 9.7 8210 0.7 12.0 8992 0.92 13.8 9638 1.14 15.3 10284 1.38 16.8 11338 1.85 19.8 11950 2.17 22 14194 3.63 27 0.25 4729 0.37 5.9 5354 0.45 6.5 5939 0.54 7.4 7196 0.8 10.7 8079 1.04 12.9 8797 1.27 14.2 9507 1.53 15.7 10639 2.02 18.6 11287 2.34 20 13635 3.84 26 0.375 CFM / Static Pressure in Inches wg 0.5 0.625 0.75 1 1.25 1.5 1.75 MAX. BHP AT A GIVEN RPM - (rpm/512)3 MAXIMUM FRPM = 835 TIP SPEED = rpm x 7.985 MAX. MOTOR FRAME SIZE = 184T 4290 0.44 6.0 5076 0.55 6.7 6567 0.83 9.7 7559 1.07 12.1 8334 1.31 13.6 9073 1.57 15.2 10257 2.07 17.9 10935 2.41 19.5 13356 3.95 25 5777 0.83 8.8 6946 1.1 11.4 7786 1.34 13.0 8605 1.61 14.6 9863 2.12 17.5 10562 2.46 19.1 13062 4.03 25 6162 1.09 10.3 7174 1.36 12.3 8068 1.64 14.1 9419 2.16 17.1 10184 2.51 18.7 12747 4.09 24 6410 1.33 11.2 7434 1.64 13.3 8933 2.19 16.6 9722 2.54 18.3 12432 4.14 24 7737 2.17 14.9 8701 2.57 17.0 11728 4.24 23 7032 2.41 14.2 10951 4.33 22 9965 4.29 21 8478 4.06 18.2 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 18 LB/LBP 36 Belt Drive LB Dimensions ST SY TH IS EF T OF 8 TH EL 6 58 49 TO 4 LE CT 40 SE 3 31 1 0 22 2 4 6 0 8 10 10 12 14 16 18 20 20 30 3 (1600) m /hr X 1000 (660) 343⁄8 (873) 46 13⁄4 hp 26 T NO cfm X 1000 63 513⁄4 46 (1168) (44) 0.0 0 0 LBP Dimensions 67 2 1/ Static Pressure in. wg 1 Static Pressure Pa hp 0.5 100 DO (1314) hp 2 hp hp (1168) (1168) 2 1/ (248) 1.0 4 3/ (44) 93⁄4 46 46 200 hp 13⁄4 300 1.5 1 325⁄8 (829) 3 400 EM CU RVE (1600) (686) RPM HP Density 0.075 lb/ft3 hp 27 (1524) 2.0 63 5 60 (1168) LB-36 LBP-36 Hood Thickness 0.064 (0.029) Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 36 (914) 36 (914) Roof Opening Square 381⁄2 (978) 381⁄2 (978) Galvanized, Aluminum, Weight* 444 (201) 338 (153) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 220 LB/LBP-36-5 1/2 315 LB/LBP-36-7 3/4 360 LB/LBP-36-10 1 397 426 LB/LBP-36-15 11⁄2 454 LB/LBP-36-20 2 499 536 LB/LBP-36-30 3 572 614 LB/LBP-36-50 5 678 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 6204 0.16 4.9 8884 0.47 8.2 10153 0.7 10.6 11196 0.94 13.7 12014 1.16 14.8 12804 1.41 16.0 14073 1.87 18.2 15116 2.31 20 16132 2.81 22 17316 3.48 25 19121 4.69 30 0.25 6937 0.55 6.3 8570 0.81 8.9 9816 1.08 12.1 10765 1.32 14.0 11668 1.58 15.4 13064 2.06 17.6 14196 2.52 19.7 15287 3.04 22 16540 3.72 24 18419 4.95 29 0.375 CFM / Static Pressure in Inches wg 0.5 0.625 0.75 0.875 1 1.25 1.5 MAX. BHP AT A GIVEN RPM - (rpm/384)3 MAXIMUM FRPM = 678 TIP SPEED = rpm x 9.425 MAX. MOTOR FRAME SIZE = 184T 7487 0.83 7.9 8911 1.1 10.6 9964 1.35 12.7 10949 1.63 14.5 12442 2.13 17.2 13646 2.61 19.3 14790 3.14 21 16087 3.84 24 18041 5.08 29 7775 1.1 9.4 9056 1.37 11.6 10127 1.65 13.7 11760 2.17 16.6 13037 2.67 18.7 14229 3.21 21 15598 3.93 24 17621 5.21 29 7716 1.34 10.1 9209 1.66 12.5 11004 2.2 16.1 12361 2.7 18.4 13649 3.26 20 15066 3.99 23 17165 5.3 28 7552 1.57 11.0 10173 2.2 15.1 11652 2.73 17.8 12989 3.29 19.9 14504 4.05 23 16683 5.37 27 8773 2.12 13.9 10837 2.72 16.7 12313 3.32 19.0 13890 4.08 22 16192 5.44 27 9559 2.65 15.8 11534 3.31 18.1 13262 4.1 21 15636 5.47 26 11584 4.04 19.2 14494 5.52 24 12970 5.45 22 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 19 LB/LBP 42 Belt Drive LB Dimensions 5 (1905) 1 ⁄4 3 52 (44) 52 (1321) (292) (1321) 100 3/ 4 0.6 2 0.4 DO LBP Dimensions 29 (1473) HIS SY S TE hp 2 NO 51 5 45 0 38 5 T 32 0 SE 25 5 19 0 4 6 8 10 12 14 16 18 20 22 24 cfm X 1000 701⁄2 58 hp hp 1/ 0.0 0 hp FT OF T 1 0.2 0 1/ 2 0.8 E 111⁄2 200 1 1.0 hp hp TH 373⁄8 (949) 2 1.2 LE CT Static Pressure Pa 300 Static Pressure in. wg (851) RPM HP Density 0.075 lb/ft3 hp MC 3 UR VE 1.4 LE 33 ⁄2 (1794) 1.6 75 1 TO 70 ⁄8 5 0 10 (1791) 20 30 40 3 m /hr X 1000 (737) 381⁄4 (972) 52 13⁄4 52 (1321) (44) (1321) LB-42 LBP-42 Hood Thickness 0.064 (0.029) Cover Thickness 0.064 (0.029) Louver Thickness 0.081 (0.036) Curb Cap Thickness 0.064 (0.029) 0.064 (0.029) Damper Size Square 42 (1067) 42 (1067) Roof Opening Square 441⁄2 (1130) 441⁄2 (1130) Galvanized, Aluminum, Weight* 530 (240) 396 (180) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 190 LB/LBP-42-5 1/2 247 LB/LBP-42-7 3/4 283 LB/LBP-42-10 1 311 334 LB/LBP-42-15 11⁄2 356 LB/LBP-42-20 2 392 420 LB/LBP-42-30 3 448 482 LB/LBP-42-50 5 515 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 8328 0.21 5.2 10827 0.47 6.9 12405 0.71 8.3 13632 0.94 9.8 14640 1.17 11.5 15605 1.41 13.2 17183 1.89 16.1 18410 2.32 18.6 19637 2.82 22 21128 3.51 23 22574 4.28 25 0.125 6455 0.25 4.3 9583 0.53 6.0 11362 0.78 7.6 12718 1.02 9.3 13812 1.25 11.0 14828 1.5 12.7 16477 1.98 15.5 17751 2.42 18.0 19020 2.93 21 20554 3.63 23 22037 4.41 24 0.25 7772 0.55 5.5 9965 0.83 7.1 11521 1.08 8.7 12766 1.33 10.4 13887 1.58 12.1 15667 2.08 14.9 17030 2.52 17.3 18378 3.04 20 19980 3.74 22 21500 4.53 24 CFM / Static Pressure in Inches wg 0.375 0.5 0.625 0.75 0.875 1 1.25 MAX. BHP AT A GIVEN RPM - (rpm/301)3 MAXIMUM FRPM = 515 TIP SPEED = rpm x 11.061 MAX. MOTOR FRAME SIZE = 184T 7932 0.81 6.5 10057 1.1 8.3 11480 1.37 9.8 12733 1.64 11.5 14715 2.16 14.3 16205 2.62 16.6 17605 3.14 19.4 19281 3.86 22 20887 4.65 24 9795 1.35 9.2 11417 1.66 10.8 13626 2.21 13.7 15201 2.68 16.1 16740 3.22 18.8 18562 3.97 21 20214 4.77 23 9401 1.59 10.3 12382 2.21 13.2 14135 2.72 15.4 15786 3.28 18.1 17683 4.04 20 19480 4.87 22 10481 2.13 12.9 12945 2.72 15.3 14735 3.3 17.5 16796 4.1 19.3 18651 4.94 21 11013 2.61 15.2 13494 3.28 17.6 15798 4.11 18.7 17822 5.01 21 14692 4.09 18.5 16871 5.01 20 14331 4.88 19.3 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 20 LB/LBP 48 Belt Drive LB Dimensions (2210) 300 58 (1473) (295) 100 4 1 hp 1/ 2 0.4 50 0.2 0 0.0 0 hp SYS hp hp hp DO LBP Dimensions 32 (1626) 0 36 6 31 2 25 8 20 4 N 15 4 8 0 12 16 20 24 28 cfm X 1000 761⁄2 64 42 TH EL 3/ 0.6 RPM HP Density 0.075 lb/ft3 hp EF TO FT HI S 2 O 58 (1473) 1/ 5 TO 1 ⁄4 150 2 1 0.8 SE LE CT 11 ⁄8 5 200 hp 1.0 T Static Pressure Pa 411⁄2 Static Pressure in. wg 3 (1054) (44) 1.2 (1041) 250 3 URV E 41 (1788) 1.4 87 TEM C 70 ⁄8 3 0 10 (1943) 20 30 40 3 m /hr X 1000 (813) 403⁄8 (1026) 13⁄4 58 58 (44) (1473) (1473) LB-48 Hood Thickness 0.064 (0.029) Cover Thickness Louver Thickness Curb Cap Thickness 0.064 (0.029) Damper Size Square 48 (1219) Roof Opening Square 501⁄2 (1283) Galvanized, Weight* 430 (195) LBP-48 0.064 (0.029) 0.081 (0.036) 0.064 (0.029) 48 (1219) 501⁄2 (1283) Aluminum, 579 (263) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 150 LB/LBP-48-5 1/2 175 199 LB/LBP-48-7 3/4 226 LB/LBP-48-10 1 249 LB/LBP-48-15 1 ⁄2 267 1 285 LB/LBP-48-20 2 314 LB/LBP-48-30 3 359 381 LB/LBP-48-50 5 420 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 9666 0.21 6.1 11277 0.34 6.9 12824 0.5 7.6 14563 0.73 8.5 16046 0.98 9.5 17205 1.2 10.6 18365 1.46 12.3 20234 1.96 15.4 23134 2.93 18.4 24552 3.5 20 27065 4.69 23 0.125 6546 0.24 5.4 8948 0.38 5.6 10846 0.56 6.8 12863 0.81 8.2 14530 1.07 9.4 15823 1.31 10.4 17103 1.58 11.7 19141 2.1 14.5 22214 3.1 17.8 23685 3.68 19.6 26278 4.89 23 0.25 CFM / Static Pressure in Inches wg 0.375 0.5 0.625 0.75 0.875 0.9 1 MAX. BHP AT A GIVEN RPM - (rpm/241)3 MAXIMUM FRPM = 420 TIP SPEED = rpm x 12.632 MAX. MOTOR FRAME SIZE = 213T 7629 0.54 7.0 10741 0.83 7.5 12787 1.1 9.2 14222 1.35 10.2 15612 1.63 11.1 17779 2.17 13.4 21041 3.21 17.2 22620 3.81 19.1 25383 5.05 23 10092 1.08 8.3 12151 1.36 9.2 13896 1.66 10.5 16397 2.2 12.5 19878 3.25 16.5 21512 3.87 18.6 24354 5.15 23 11357 1.61 9.6 14665 2.22 12.2 18650 3.29 15.9 20378 3.92 17.9 23363 5.21 22 11934 2.1 11.5 17134 3.31 15.5 19104 3.95 17.4 22317 5.25 22 15069 3.25 14.8 17564 3.95 17.1 21159 5.29 21 11596 2.84 13.4 15491 3.86 16.2 19839 5.31 21 15076 3.85 16.0 19534 5.3 21 18029 5.23 20 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 21 LB/LBP 54 Belt Drive LB Dimensions 35 64 (1626) SY STE H IS FT TO EF TH EL 3 TO 0 (2121) NO 18 5 4 13 0 10 15 10 20 20 25 30 35 40 30 40 50 60 3 m /hr X 1000 (889) (1108) 13⁄4 8 cfm X 1000 435⁄8 (44) 0.0 0 83 ⁄2 70 34 29 1 (1778) 1 9 T 0.2 0 40 23 SE LE CT Static Pressure in. wg Static Pressure Pa hp hp 0.4 DO LBP Dimensions hp 1 50 0.6 2 (1626) 100 1/ (318) 0.8 1 12 ⁄2 64 hp 64 (1626) 150 1.0 2 13⁄4 1 200 2 hp (1153) RPM HP Density 0.075 lb/ft3 1/ 3 250 453⁄8 (44) 1.2 7 (965) 300 hp (2019) (2210) 5 38 MC UR VE 1.4 87 79 ⁄2 1 64 (1626) LB-54 Hood Thickness 0.064 (0.029) Cover Thickness Louver Thickness Curb Cap Thickness 0.064 (0.029) Damper Size Square 54 (1372) Roof Opening Square 561⁄2 (1435) Galvanized, Weight* 596 (270) LBP-54 0.064 (0.029) 0.081 (0.036) 0.064 (0.029) 54 (1372) 561⁄2 (1435) Aluminum, 780 (354) All dimensions are in inches (millimeters). Weight in pounds (kilograms). *Weight shown is the largest cataloged Open Drip Proof motor. See page 8 for severe duty LBP dimensions. Model Number Motor HP Fan RPM 130 LB/LBP-54-10 1 155 206 LB/LBP-54-15 11⁄2 235 LB/LBP-54-20 2 258 277 LB/LBP-54-30 3 296 323 LB/LBP-54-50 5 350 376 LB/LBP-54-75 71⁄2 401 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 12159 0.25 4.6 14497 0.42 5.8 19267 0.99 8.7 21980 1.47 11.2 24131 1.95 12.1 25908 2.41 14.1 27685 2.94 17.6 30210 3.82 19.3 32736 4.87 18.9 35167 6.03 22 37506 7.32 25 0.125 11186 0.48 4.9 17356 1.1 8.5 20319 1.6 11.2 22628 2.09 12.5 24517 2.57 13.4 26383 3.11 15.5 29017 4.01 17.8 31634 5.06 19.5 34142 6.25 23 36544 7.54 26 0.25 CFM / Static Pressure in Inches wg 0.375 0.5 0.625 0.75 0.875 1 1.125 MAX. BHP AT A GIVEN RPM - (rpm/198)3 MAXIMUM FRPM = 401 TIP SPEED = rpm x 14.137 MAX. MOTOR FRAME SIZE = 213T 13895 1.12 8.7 17983 1.66 11.3 20831 2.18 13.0 22962 2.68 14.1 25030 3.25 15.2 27789 4.17 17.3 30514 5.25 20 33111 6.45 23 35583 7.77 26 14194 1.6 11.7 17904 2.21 13.3 20554 2.72 14.4 23122 3.31 16.0 26305 4.27 18.4 29312 5.39 21 32039 6.62 24 34583 7.96 27 17326 2.65 13.7 20394 3.34 15.1 24165 4.31 18.3 27766 5.46 22 30716 6.72 25 33500 8.11 28 16072 3.1 13.1 21535 4.29 16.8 25487 5.5 21 29030 6.79 26 32150 8.19 29 17215 4.01 14.7 22974 5.43 19.0 26889 6.82 24 30332 8.24 29 18944 5.13 17.8 24483 6.71 22 28324 8.29 27 20824 6.4 21 26018 8.13 26 22767 7.81 24 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (Bhp) does not include transmission losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sones. 22 Specifications Direct Drive Specifications The LD and LDP exhaust fans shall be direct drive type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the fan’s venturi for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan shall be constructed of heavy gauge steel or aluminum with a rigid internal support structure and a birdscreen. Motors shall be mounted on vibration isolators. Motors shall be readily accessible for maintenance. A disconnect switch shall be factory installed and wired from the fan motor to a junction box within the motor compartment. A conduit chase shall be provided through the curb cap to the motor compartment for ease of electrical wiring. All fans shall bear the AMCA Certified Ratings Seal for sound and air performance. Each fan shall bear a permanently affixed manufacturer’s engraved aluminum nameplate containing the model number and individual serial number for future identification. Fans shall be models LD or LDP as manufactured by Greenheck Fan Corporation in Schofield, Wisconsin, USA. BELT DRIVE SPECIFICATIONS The LB and LBP exhaust fans shall be belt drive type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the fan’s venturi for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan shall be constructed of heavy gauge steel or aluminum with a rigid internal support structure and birdscreen. Motors shall be heavy duty ball bearing type, carefully matched to the fan load, and furnished at the specified voltage, phase and enclosure. Drive frame assembly shall be constructed of heavy gauge steel. Motors and drives shall be mounted on vibration isolators. Motors and drives shall be readily accessible for maintenance. Precision ground and polished fan shafts shall be mounted in permanently sealed, lubricated pillow block ball bearings. Bearings shall be selected for a minimum L10 life in excess of 100,000 hours (L50 average of 500,000 hours) at maximum cataloged operating speed. Drives shall be sized for a minimum of 150% of driven horsepower. Pulleys shall be of the cast type, keyed and securely attached to the wheel and motor shafts. Motor pulleys shall be adjustable for final system balancing. A disconnect switch shall be factory installed and wired from the fan motor to a junction box installed within the motor compartment. A conduit chase shall be provided through the base to the motor compartment for ease of electrical wiring. All fans shall bear the AMCA Certified Ratings Seal for sound and air performance. Each fan shall bear a permanently affixed manufacturer’s engraved aluminum nameplate containing the model number and individual serial number for future identification. Fans shall be models LB or LBP as manufactured by Greenheck Fan Corporation in Schofield, Wisconsin, USA. 23 Other Exhaust Fans Models G and GB, direct or belt drive, spun aluminum downblast centrifugal roof exhaust fans are an economical means of exhausting air. They utilize a backward inclined wheel and are available in 45 different sizes. Performance capacities range up to 3.25 in. wg (810 Pa) of static pressure and from 50 to 44,700 cfm (85 to 75,900 m3/hr). Series C models CUE, CUBE, CW and CWB, are commonly used for general clean air, mild grease and fume hood exhaust applications. Both roof upblast and sidewall configurations are specifically designed to discharge air directly away from the mounting surface. These models are constructed of aluminum and use an aluminum backward inclined wheel. They are UL/cUL Listed for electrical or grease. Performance capacities ranges up to 5 in. wg (1242 Pa) and up to 30,000 cfm (51,000 m3/hr). Model SWB centrifugal backward inclined belt driven utility fans are designed for supply, exhaust and return air applications requiring higher discharge velocities and high static pressures. The SWB Series 100 is for general clean air applications. The SWB Series 200 fans are constructed with heavy gauge steel. Designed for light industrial duty and grease applications, it’s capacities range from 70 to 27,000 cfm (120 to 45,900 m3/hr) and up to 5 in. wg (1,118 Pa) of static pressure. SWB fans can be mounted indoors or outdoors. Models NYD and NYB, direct or belt drive, tamper resistant centrifugal roof exhaust fans are galvanized construction and prevent entry into the unit and/or building. They utilize a backward inclined wheel and are available in 10 different sizes. Performance capacities range from 170 to 8,080 cfm (290 to 13,700 m3/hr) and up to 1 in. wg (249 Pa) of static pressure. Building Value in Air Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative airrelated equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet dependable operation they experience long after the construction project ends. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Prepared to Support Green Building Efforts Catalog Series L Rev 4 April 2008 R Copyright © 2008 Greenheck Fan Corp.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Modify Date : 2008:05:28 15:36:17-05:00 Create Date : 2008:05:22 08:57:59-05:00 Metadata Date : 2008:05:28 15:36:17-05:00 Format : application/pdf Document ID : uuid:f0bddf04-0d27-4b66-b0bd-fbc958002bf9 Instance ID : uuid:e02d1b2b-f4f2-40a2-a9cf-5b563897f5f2 Has XFA : No Page Count : 24EXIF Metadata provided by EXIF.tools