Guard RFID Solutions PTE2 Generator for active RFID tag wakeup User Manual Tag Exciter Location Appliance

Guard RFID Solutions Generator for active RFID tag wakeup Tag Exciter Location Appliance

Contents

User Manual

Download: Guard RFID Solutions PTE2 Generator for active RFID tag wakeup User Manual Tag Exciter          Location Appliance
Mirror Download [FCC.gov]Guard RFID Solutions PTE2 Generator for active RFID tag wakeup User Manual Tag Exciter          Location Appliance
Document ID3836436
Application IDpZmJPnJZj2UyYZy/eoPkaA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.43kB (192889 bits)
Date Submitted2018-05-02 00:00:00
Date Available2018-05-02 00:00:00
Creation Date2018-04-13 12:20:59
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-04-13 12:20:59
Document TitleTag Exciter – Location Appliance
Document CreatorMicrosoft® Word 2016
Document Author: John Mitchell

PRODUCT INFORMATION
Proximity Tag Exciter
PTE
FEATURES:
•
Creates a precise and definable tag detection zone at a specific location
•
Adjustable detection zone from 2 – 10’
•
Simple installation – only requires mounting and power
•
May be mounted above the ceiling or surface-mounted on a wall
•
Fully supervised device, using 433MHz transceiver
•
PoE compatible – simplifies and reduces installation costs
DESCRIPTION:
The Proximity Tag Exciter creates a 125 KHz radio frequency (RF) zone with a unique ID that allows
instant and accurate location of GuardRFID’s Active Tags equipped with 125KHz Receivers. When
such an active tag enters the PTE zone, it immediate transmits the zone’s unique ID to the system.
This real-time tag location information can then be used by GuardRFID’s Argus network to detect
the precise location of the tag. The PTE is primarily used for very close proximity tag detection,
such as for room or bed level location, a narrow choke point leading from one manufacturing cell to
another or tagged items on a conveyor belt, for example.
The field strength of the Exciter’s LF field can be adjusted from 2’ to 10’, creating a defined detection
zone. By adjusting the LF field the Exciter can tightly define a specified area. The Tag Exciter also
has a UHF transceiver, so that it can communicate with the network. This communications
capability is used to monitor the health of the PTE in real-time, and to enable remote adjustment of
its LF field size.
The PTE can be either recessed within a wall or can be surface mounted on the wall.
SPECIFICATIONS:
PTE
Part Number
61-30006
Output Frequency
125 KHz
Power
12VDC, 1.0A max. (Individual power adapter, CPS, or PoE)
Dimensions (W x H x D)
Weight
18 oz. (510 g)
Operating Temperature
Humidity
Mounting
Guard RFID Solutions Inc.
sales@guardRFID.com
Coverage Area
Tel: 866.785.7343
Fax: 604.524.4018
Regulatory
Indicators
Warranty
9.25 in. x 4.0 in. x 2.075 (235 mm x 102 mm x 53)
14° F to 122°F (-10°C to 50°C)
0 – 95% RH non-condensing
Wall or ceiling
2 – 10 ft. radius (configurable)
Visual indicators (power/communications, alarm/error, field status)
and audible buzzer for alerts
FCC, IC
1 Year
This device complies with part 15 of the FCC Rules and with Industry Canada specification RSS-210. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la spécification RSS-210 d'Industry Canada. Son fonctionnement est soumis aux deux conditions suivantes:
(1) cet appareil ne peut engendrer aucune interférence et
(2) il doit accepter toute interférence qu'il reçoit, y compris celles qui peuvent altérer son fonctionnement.
FCC ID:
IC:
02-00094-110
VZKPTE2
9937A-PTE2
NOTE:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
Specifications Subject to Change Without Notice. © Guard RFID Solutions, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 1
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : Tag Exciter – Location Appliance
Creator                         : John Mitchell
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:04:13 12:20:59-07:00
Modify Date                     : 2018:04:13 12:20:59-07:00
Document ID                     : uuid:E0F42B5E-C35C-417B-B8D8-3D5D2A86D471
Instance ID                     : uuid:E0F42B5E-C35C-417B-B8D8-3D5D2A86D471
Author                          : John Mitchell
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VZKPTE2

Navigation menu