-  1  -Heart  Rate  Monitor(HRM-3200)User’s  ManualH3  SYSTEM  Co.,  Ltd.
-  2  -USA-Federal  Communications  Commission  (FCC)This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to the  following  two  conditions:  (1)  This  device  may  not  cause  harmful interference,  and  (2)  this  device  must  accept  any  interference  received, including  interference  that  may  cause  undesired  operation.This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a Class  B  digital  device,  pursuant  to  Part  15  of  FCC  Rules.  These  limits  are designed  to  provide  reasonable  protection  against  harmful  interference  in  a residential  installation. This  equipment  generates,  uses,  and  can  radiate  radio  frequency energy. If  not  installed  and  used  in  accordance  with  the  instructions,  it  may  cause harmful  interference  to  radio  communications.  However,  there  is no guarantee  that  interference  will  not  occur  in  a  particular  installation.If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception,  which  can  be  determined  by  tuning  the  equipment  off  and  on,  the user is encouraged to try and correct the interference by one or  more  of the  following  measures:  - Reorient or relocate the receiving antenna    -  Increase  the  distance  between  the  equipment  and  the  receiver.    -  Connect  the  equipment  to  outlet  on  a  circuit  different  from  that  to     which the receiver is connected.    -  Consult  the  dealer  or  an  experienced  radio/TV  technician  for  help.Any changes or modifications not expressly approved by the party responsible  for  compliance  could  void the user’s authority to operate  the equipment.
-  3  -I.  General  Description     This  device  is  to  measure  heart  rate  and  being  composed  of  main  body  with sensing part, arm band, battery charger and an adaptor (Optional).     The  measurement  principle  is  based  on  the  optics.  The  amount  of the       reflected  light  compared  to  the  acting  light  is  measured  at  the  sensing  part.     The  change  of  the  light  reflectance  is  analyzed  to  calculate  heart  rate  at     the  main  body.  Calculated  pulses  are  displayed  on  the  LCD  screen  of  main     body,  and  can  be  wirelessly  transmitted  to  other  devices,  PC  or  smart     phone.  This  device  uses  a  rechargeable  battery  and  can  be  charged     through  DC  adapter.II.  Component  Description1.  Heart  rate  monitor                  ①  Main body              ③  Arm Band      ⑤  micro-USB  connecter                                                    Charging Terminal LCD, 2 Buttons (TOP)  ④  Sensing  Part(Bottom)
-  4  -① Main body : The main body is central processing part  composed    of  LCD  display,  ON  /  OFF  button,  measurement  button,  charging    terminals  and  a  built-in  communication  module.ⓐ  charging  terminal  :  Connect  the  inner  battery  to  charging terminal  by  adaptorⓑ  LCD  display  :  LCD  screen  that  displays  heart  rate. ⓒ  " "(On/Off) Button : power ON / OFFⓓ  " "(Start/Stop)  Button  :  Measurement  Start  /  Stop,       Wireless  (Bluetooth)  Start  /  Stop  Button ③  Arm  band  :  Fixtures  for  holding  main  body  and  sensing  part  to   arm. ④ Sensing part : optical parts which measures PPG(Photo       plethysmography) signal. It measures the amount of the    reflected light compared to the acting light at the Arm⑤  Micro-USB  connecter:  Put  the  heart  rate  monitor  to  micro-USB connecter  for  charging.III.  Using  a  heart  rate  monitor1.  Wearing  and  power-on  the  device(1)  Wearing  heart  rate  monitor  arm  band.    *  Caution  :  When  you  wear  arm  band,  The  Arm  band  should  be  fasten tightly  not  to  move  around  a  arm.(2)  Press  the  ‘ S(start)’  button  :  displays  that  LCD  is  ON.
-  5  -2.  Heart  rate  measurement(1)  In  order  to  start  the  heart  rate  measurement,  press  “ (Measurement Start)”  button.   * Measuring Notes          The  initial  10  seconds  are  needed  to  initialize  the  measurement,  it  is     recommended during this first 10 seconds not to move your arms,(2)  If  the  10  seconds  initialization  is  successful,  the  heart  rate  monitor   displays your current heart rate at the LCD display.   * Notice          In  some  cases  (not  usual),  If  it  displays  ‘E0’  for  a  while,  It  is recommended  to  press  the  ‘ '(Measurement  stop)  button  to  stop measuring  and  restart  monitor  after  reworn  the  device.(3)  During  exercise,  any  of  the  buttons  should  not  be  pressed.3.  After  using  the  heart  rate  monitor.(1)  “ (Measurement  Stop)”  button.      -  If  The  heart  rate  monitor  will  terminated  successfully,  then  press  the      “ (stop)”  button  for  Heart  rate  monitor  power  down.  After  you wear  off  the  arm  band,  please  be  kept  charged  by  plugging  in  the adapter.(2)  After  measuring  or  end  of  measure, it can be automatically wirelessly         transmitted  to  other  devices,  PC  or  smart  phone.4.  How to store and maintenance(1)  Storage  environment  :  Temperature  5~40  ℃,  humidity  is  kept  at  less    than 95%.(2)  The  following  points  should  be  taken  when  storing.   - not exposed to corrosive gases.   - should be kept away from moisture and dust.   - should be kept clean.
-  6  -5. Precautions during use(1) Wear the sensing part with care to avoid application of excessive  force.(2) Remain stop during 10 to 20 seconds after pressing the “(measurement  Start)”  button(3)  Do  not  stare  at  the  light  of the sensing part since the LED light is    harmful if you stare on.(4)  This  device  was  developed  for  purposes  described  in  this  manual  and   the manufacturer is not responsible for side effects caused by  an      improper  purpose  or  improper  use.(5)  Before  using  the  device  and  accessory,  please  check  and  confirm  that there  is  no  faulty.  When  in  doubt,  do  not  use  and  notify  the  manufacturer or  service  center  immediately.(6)  This  device  should  be  repaired  by  an  approved  person  and  approved    organizations.(7)  This  device  should  not  be  repaired  by  user  itself.(8)  Use  only  standardized  accessories  which  is  provided  with  this  device. IV.  Electrical  rating(1)  The  type  and  degree  of  protection  to  protect  against  electrical    shock : The internal power-type  equipment,  BF-type  mounting(2) Electrical Rating: DC 3.7V Lithium polymer battery (240mAh)        V.  Matters(1)  The  product  name,  model  name  (model):  heart  rate  monitor  (HRM-3200)(2)  the  manufacturer's  name  and  address  :       -  Company  Name:  H3  System  Co.,  Ltd.      -  Address        :  3rd  floor,  Daedeok  Bldg.,  397-27,  Doryong-dong,                                 Yuseong-gu, Daejeon city, Korea (republic  of)   - Phone          : +82-42-862-9313~4   - Homepage : http://www.h3system.co.kr