HBC radiomatic TC240 Bluetooth Module User Manual User manual TC240

HBC-radiomatic GmbH Bluetooth Module User manual TC240

User Manual

    Transceiver module TC240 - Pos: 1 /Technische Dokumentation/Betriebsanleitungen/Allgemein/----- Seitenumbruch ------ @ 1\mod_1219672326234_0.doc @ 29509  User manual
   Pos: 2 /Technische Dokumentation/Betriebsanleitungen/Allgemein/1. Seite ML @ 3\mod_1243609355222_48.doc @ 44905 Table of Contents  FCC notesIC notesIntended useShielding provision of the RF partInstallation guidelinesTechnical dataAntennaLabelling  /Technische Dokumentation/Betriebsanleitungen/Allgemein/----- Seitenumbruch ------ @ 1\mod_1219672326234_0.doc @ 29508    Pos: 3 /Technisc he Dokumentation/Betriebsan leitungen/Allgemei n/----- Seitenumbruch ------  @ 1\mod_1219672326234_0.doc @ 29509  Manufacturer:  HBC-radiomatic GmbH • Haller Straße 45 – 53 • 74564 Crailsheim • Germany • Tel. +49 7951 393-0 • info@radiomatic.com. HBC.radiomatic GmbH is not liable for any misprints or errors! – Specifications and design subject to change without notice.® radiomatic and radiobus   are registered German trademarks. © 26 / 2012, HBC-radiomatic GmbH, 74564 Crailsheim, Germany No part of this document may be reproduced in any manner whatsoever without the expressed written permission of HBC-radiomatic GmbH.
   Pos: 4 /Technische Dokumentation/Betriebsanleitungen/Allgemein/FCC_TC240 @ 8\mod_1340972119078_48.doc @ 97248 FCC notes Part 15.21 Statement Changes or modifications made to this equipment not expressly approved by HBC-radiomatic GmbH may void the FCC authorization to operate this equipment.  Part 15.105 Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.    Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.    Consult the dealer or an experienced radio/TV technician for help.  RF Exposure Statement Radiofrequency radiation exposure information The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for human contact during normal operation is minimized.   The modular approved transmitter complies with the RF Exposure requirements for fixed or mobile installations / categorised host devices where a minimum separation distance of at least 20 cm between the radiating part and any human body can be assured under normal operating conditions.
  IC notes RSS-GEN – User Manual Statements (English/French)  Licence exempt  This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1.  this device may not cause interference, and 2.  this device must accept any interference received, including interference that may cause undesired operation of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1.  l'appareil ne doit pas produire de brouillage, et 2.  l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.   Note: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network, protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together.  This precaution may be particularly important in rural areas.   Note: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. This product meets the applicable Industry Canada technical specifications.    Safety Instructions  In customer related documents of the end product like instruction manuals, installation guides etc. appropriate safety instructions have to be included. The supplier of the complete system is responsible for these safety instructions.  Pos: 5 /Technisc he Dokumentation/Betriebsan leitungen/Allgemei n/----- Seitenumbruch ------  @ 1\mod_1219672326234_0.doc @ 29509
   Pos: 6 /Technische Dokumentation/Betriebsanleitungen/Sonstiges/TC240 @ 7\mod_1327655574965_48.doc @ 91463 Intended use  The TC240 is a SHF transceiver for data transfer with fast transmit-receive switchover. The frequency range is 2402 – 2480 MHz, according to the hardware version for USA.  This module is not sold separately, but is exclusively used for own HBC systems.      Shielding provision of the RF part The RF component has been designed in this way that the user cannot have easy access. Efficient shielding of RF part is achieved by means of metal shielding. The metal shielding is soldered up with the circuit board.    Installation guidelines   Align module with connector and insert it with care.   Affix module with fixing screw.  Check proper installation.
  Technical data Technical Specification Common data Module code  TC240 Country identity  --- Label  CE, FCC, IC (TC20 only), Gost-R Antenna MMCX socket Number of RF channels  79 Frequency range  2402 – 2480 MHz Channel spacing  1 MHz Operating temperature range  -30 °C … +80 °C Modulation GFSK, π/4 DQPSK, 8DPSK Dimensions  (40 x 30 x 12) mm (TC20) (40 x 30 x 16) mm (TC38) Weight 8 g   Transmitter specific data (@ 25 °C) Parameter Min. Typ. Max. Unit Supply voltage  3.3 4.2 4.6 V Parameter Min. Typ. Max. Unit Power (ERP)  - < 18 - dBm TX – output spectrum 20 dB bandwidth  -  900  -  kHz Adjacent Channel Power F = Fo + 2 MHz  -  -  -20  dBm Adjacent Channel Power F = Fo + 3 MHz  -  -  -40  dBm Adjacent Channel Power F = Fo > 3 MHz  -  -  -40  dBm Initial carrier frequency tolerance  -20  -  20  kHz Out of band spurious emissions  0.030 – 1.000 GHz  -36  -  -  dBm Out of band spurious emissions  1.000 – 12.750 GHz  -30  -  -  dBm Out of band spurious emissions  1.800 – 5.100 GHz  -47  -  -  dBm Out of band spurious emissions  5.100 – 5.300 GHz  -47  -  -  dBm Supply current  15 45 76 mA Receiver specific data (@ 25 °C) Parameter Min. Typ. Max. Unit Supply voltage  3.3 4.2 4.6 V Sensitivity (0.1% BER)  -  -90  -  dBm Adjacent channel selectivity at 0.1% BER / F = fo + 1 MHz  -  0  -  dB Adjacent channel selectivity at 0.1% BER / F = fo - 1 MHz  -  0  -  dB Adjacent channel selectivity at 0.1% BER / F = fo + 2 MHz - -20 - dB Adjacent channel selectivity at 0.1% BER / F = fo - 2 MHz - -30 - dB Adjacent channel selectivity at 0.1% BER / F = fo - 3 MHz - -40 - dB Adjacent channel selectivity at 0.1% BER / F = fo + 5 MHz - -40 - dB Maximum input level (0.1% BER)  -20  -  -  dBm Blocking 0.030 – 2.000 GHz  -10  -  -  dBm Blocking 2.000 – 2.400 GHz  -27  -  -  dBm Blocking 2.500 – 3.000 GHz  -27  -  -  dBm Blocking 3.000 – 12.750 GHz  -10  -  -  dBm Supply current  15  -  18  mA
  Antenna  The antenna is an omnidirectional straight dipole which has a gain of 2,14dBi and an impedance of 50Ω and is supplied with the module.   Other antennas with less gain are possible to use as well, e.g. a directly mounted λ/4-antenna with a length of 32mm.   The module should be used in “mobile” hosts with a distance of 20cm from the user to the antenna only.   The following picture shows the directly mounted λ/4-antenna on the TC240-Module instead of the omnidirectional straight dipole, which has more gain:                        TC20-version of TC240 with λ/4-antenna
  Labelling                  Labelling version 1 (TC38)   The TC38-version is not available in Canada.                      Labelling version 2 (TC20)   ===== Ende der S tückliste =====        Labelling for installing the module in another device    HBC label Antenna plug FCC-Label HBC label Antenna plug FCC-Label & IC-Cert. No
  The end product (host) with the module built inside must be marked as follows:  Contains Transmitter Module FCC ID: NO9TC240 / IC: 2977A-TC240 Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Module transmetteur ID IC: 2977A-TC240. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d’interférences nuisibles et (2) appareil doit accepter toute interference recue, y compris les interferences qui peuvent pertuber le fontionnement.  The following regulatory statements shall be printed in the user manual for the end product. This device complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and should be installed/operated with minimum distance 20 cm between the radiator & your body.   FCC Information:  Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to Part 15 of the FCC Rules.   Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the system off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  1. Reorient or relocate the receiving antenna. 2. Increase the separation between the end product and receiver. 3. Connect the end product into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio TV technician for help.   Industry Canada Information:  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network, protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together.  This precaution may be particularly important in rural areas.  NOTE: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. This product meets the applicable Industry Canada technical specifications.   Safety Instructions In customer related documents of the end product like instruction manuals, installation guides etc. appropriate safety instructions have to be included. The supplier of the complete system is responsible for these safety instructions.   ===== Ende der S tückliste =====