HBC radiomatic TC64126 Transceiver Module User Manual
HBC-radiomatic GmbH Transceiver Module
User Manual
User Manual Transceiver Module TC 641 UM-TC641-FCC-V2.DOC [ Word 2002 ] SEDH/DOKJH HBC Page 1 / 5 – Transceiver Module TC 641 (FCC) HBC-radiomatic GmbH • 74564 Crailsheim • Germany Information and specifications subject to change without notice. www.hbc-radiomatic.com 2007-06-05 User Manual Transceiver Module TC 641 UM-TC641-FCC-V2.DOC [ Word 2002 ] SEDH/DOKJH Page 2 / 5 Manufactured by: HBC-radiomatic GmbH Haller Strasse 47 – 53 74564 Crailsheim, Germany Telephone: +49 ( 0 ) 79 51 – 3 93 – 0 Fax: +49 ( 0 ) 79 51 – 3 93 – 50 E-mail: info@radiomatic.com http://www.hbc-radiomatic.com HBC-radiomatic GmbH is not liable for any misprints or errors! – All rights reserved. ™ HBC-radiomatic is a registered German trademark. © 2007 – 06 , HBC-radiomatic GmbH , 74564 Crailsheim , Germany No part of any software or of the present document may be reproduced in any manner whatsoever without the expressed written permission of HBC-radiomatic GmbH. HBC-radiomatic GmbH • 74564 Crailsheim • Germany Information and specifications subject to change without notice. www.hbc-radiomatic.com 2007-06-05 User Manual Transceiver Module TC 641 UM-TC641-FCC-V2.DOC [ Word 2002 ] SEDH/DOKJH Page 3 / 5 Table of Contents Warnings ........................................................ 4 Technical Data ................................................ 5 HBC-radiomatic GmbH • 74564 Crailsheim • Germany Information and specifications subject to change without notice. www.hbc-radiomatic.com 2007-06-05 User Manual Transceiver Module TC 641 UM-TC641-FCC-V2.DOC [ Word 2002 ] SEDH/DOKJH Page 4 / 5 Warnings This device complies with part 15 of the FCC rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications by the user could void the user’s authority to operate the equipment! NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. IMPORTANT NOTE: FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. HBC-radiomatic GmbH • 74564 Crailsheim • Germany Information and specifications subject to change without notice. www.hbc-radiomatic.com 2007-06-05 User Manual Transceiver Module TC 641 UM-TC641-FCC-V2.DOC [ Word 2002 ] SEDH/DOKJH Page 5 / 5 Technical Data Interface: Type: SPI interface Required input voltage: 3 VPP Maximum data rate: 250 kBit/s Port impedance: 100 kOhm // 220 pF Antenna terminal impedance: 50 Ohm Common (RX+TX): Frequency range: TC 64125 455,0 MHz – 465,0 MHz TC 64126 465,0 MHz – 470,0MHz Frequency accuracy: +/- 2,5 ppm Operating voltage: 3,3 ... 4,6 V Channel pattern: 12,5 kHz LF transmission bandwidth: 150 Hz ... 2,4 kHz Modulation type: F2D Operating temperature range: -30 ... +70 °C Transmitter: Output power: +10 dBm Frequency deviation: +/- 2,5 kHz Current consumption (when transmitting): 100 mA Switch-over time (RX-TX): < 1 ms Receiver: Sensitivity: -105 dBm (20dB S/N) First IF: 45 MHz Second IF: 455 kHz Current consumption (when receiving): 70 mA Switch-over time (TX-RX): < 1 ms LF output voltage: 65 mV RMS at +/-2,5 kHz deviation (internal test point only!) IP3: 0 dBm HBC-radiomatic GmbH • 74564 Crailsheim • Germany Information and specifications subject to change without notice. www.hbc-radiomatic.com 2007-06-05
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2007:06:05 12:27:43+02:00 Creator Tool : Acrobat PDFMaker 7.0 für Word Modify Date : 2007:06:05 12:27:55+02:00 Metadata Date : 2007:06:05 12:27:55+02:00 Format : application/pdf Title : User Manual Creator : SEDH/DOKUS Description : TC 641 FCC Document ID : uuid:ad70c2f7-f8bc-41be-b9fa-a580dd3b7867 Instance ID : uuid:89bf05b6-ee54-440b-a673-aba37e6be034 Company : HBC-radiomatic GmbH ; D-74564 Crailsheim Source Modified : D:20070605102726 Page Count : 5 Page Layout : OneColumn Subject : TC 641 FCC Author : SEDH/DOKUSEXIF Metadata provided by EXIF.tools