QKQ— EXHIBIT 5 SYSTEM MANUAL 5473A CLOUDS REST ' MARIPOSA, CAUFOHNIA 95338 ' (209) 966-5240 - FAX (209) 966-4257 MiniProx Reader Installation Manual Installation Requirements The following instructions Wl|| explain the installation procedure for the MiniProx Reader. The instructions include these sec- tions' Mounting Instructions (hazardous & nonhazardous) Connecting the Reader to the Host Testing & Operation of the MInIPrnx Reader Mounting Instructions 1. Determine an appropriate mounting position for the Reader. 2. Drill two 7/64th (.109) inch holes for mounting the Reader to the surface. Tolerances ‘(lt -/- OJ” (xx zlr 010" no mmmau — 3. Drill a 3/8 to 1.0 Inch hole for the cable. If you are mounting on metal place a grommet around the edge of the hole. 4. Route the interface cable from the Reader and/or power supply to the Host, Linear type power supply is recommended. 525 Figure I Check all electrical codes for proper cable installation Mount the Reader with the screws provided when mounting onto metal mull/ans or junction boxes. On other materials use appropriate fasteners. Connecting the Reader to the Host The MiniProx is available with an 18" Pigtail With a 10 conductor cable and a 10 conductor terminal strip. 3. Pigtail - Prepare the new cable by cutting the cable d. Prepare the new cable by cutting the cable jacket jacket back 1-1/4“ and strip the wires Vi”. back 1-1/4 inches and strip the wire ‘A Twist the ends b. Splice the cable and the pigtail together and seal of the wires to eliminate stray strands. the splice ifthe Thin Line will be an outdoor unit. Trim e. Form each wire into a hook and install each wire by and cover all conductors that are not used. wrapping it around the screw. c. Terminal Strip - Loosen the terminal strip screws until the top of the screw is flush with the back surface of the Reader. Be careful not turn them further; they are not captive and will fall out. HID Corporation 9292 Jeronimo Road Irvine. CA 92518 USA TEL (714) 598—1600 (800) 237-7769 FAX (714) 598-1 590 Web page, E-mail -www.prox.com MiniProx Reader Installation Manual 5365-903 REV D 1 Connect the Reader to the Host according to this wiring diagram and the Host installation guide. The legend for wiring is color coded according to the "Wiegand Standard” for the recommended cable. The numbering for the terminals is shown on the back label and in Figure 2 "— “m BM mm, m— ” These connections are OPTlONAL. All other connections are required. Terminal Strip Marking the wires will make future maintenance easier. Cable Notes 1) When using a separate power supplyforthe Reader, me power supply and Host should have a common ground (voltage reference), 2) if the Host is controlling the beeper, Hold, or the LEDs are configured for the dual LED mode. additional conductors will be required. The recommended cables are Alpha 12950, 12960, 12970, 1298C and 12990 that are five. six, seven, eight and nine conductors respectively, Larger wire gauges are acceptable, The wire is to be stranded with an overall shleld, either foil or braided. 3) The Cable shield should be connected to the Shield Ground on Reader TB1— E, and left floating at the panel or power supply end of the cable. This configuration is the best for shielding the reader cable from external interference and reducing the likelihood of the Reader causing interference. Testing Br Operation of the MultiProx Reader After wiring the Reader and power supply, the Reader is ready to be tested. 1. Power up the Reader and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay, This indicates that the micro-controller unit is working properly. 2. Present an ID card to the Reader and the LED should momentarily turn green, indicating a read of the card. 3. If the Reader LED lS controlled by the Host refer to the Host description of the LED operation, NOTES: THE ABOVE ARE RECQMMENDED INSTALLATION PROCEDURES. ALL LOCAL, STATE AND NATlONAL ELECTRICAL CODES TAKE PRECEDENCE HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690 Web page, E-mail - www.prox.com MiniProx Reader installation Manual 5365-903 REV D 2 er r] Figure 3 Important Product Specifications Power Requirements Powersuppiy Linear type recommended Installation Procedure: (hazardous unit) 1. Determine an appropriate location for the junction box, Attach the junction box to the mounting surface using the 4 holes shown in figure 3, Mount the junction box cover to the junction box and mount the Reader to the cover with the provided screws. 2. Route conduit and cable to the junction box per National Electric Code An‘lcle 720-2, Provide enough cable length to allow wiring of the Reader assembly outSide of lhejunction box. Route wiring from junction box through the center hole of the junction box cover. 3. Loosen the terminal strip screws until there is sufficient room to wrap a wire around the screw post. Prepare the cable by cutting the cable jacket beck 1-1/4 inches and strip the wires ‘/4". Twist the ends of the wires to eliminate stray strands. 4. Connect the Reader & the Host together. Refer to Figure 2 (nonhazard- ous installation section). Testlng and operation are the same for this unit. Operating Voltage Range (+00) 4.75VDC 716.0VDC Absolute Maximum (+DC non-operating) 18.0VDC Maximum Average Current 5V/12V 40mA/50mA Peak Current 5V/12V (maximum) 60mA/120mA Peak Current 5V/12V (typical non-metallic mounting) 50mAI100mA Peak Current 5V/12V (typical mounted on metal) 60mA/120mA Operating Parameters Maximum cable Distance to Host 500 feet (152 meters) HID Corporation 9292 Jeronimo Road Irvine, CA 92613 USA TEL (714) 598—1600 (800) 237-7769 FAX (714) 598—1690 Web page, E-mail — www.prox.com MiniProx Reader Installation Manual 5365—903 REV D J Thin Line II Reader Installation Manual Installation Requirements The following instructions will explain the installation procedure for the Thin Line II Reader. The instructions include these sec- tions: Mounting instructions Connecting the Reader to the Host Testing & Operation of the Thin Line ll Reader —_—“ Mounting Instructions 1. Determine an appropriate mounting position for the Reader. Parts List (Included) 1) Thin Line ii 2) 156-32 x 1" self tapping, Type T or 23 3) Installatlon Sheet Quantity Parts Recommended (not Included) 1) ere Splice 2) Grommet 3) DC Power Supply 4.75 to 16VDC, SOmA 4) Cabie,10 conductor , 22 AWG 2. Drill two 7/64th (.109) Inch holes for mounting the Reader to the surface 34 Drill a 3/8 to 1.0 Inch hole for the cable. If you are mounting on metal place a grommet around the edge of “ ‘ the hole. I g I 2 4 Route the interface cable from the l It / I Reader avid/or power supply to the i ' ‘ ‘ Q / I go Host. Linear type power supply is ‘ f II recommended. I . I} l 1 II I . 2 LEE—1 9—44 Check all electrical codes forproper I cable installation Figure 1 Connecting the Reader to the Host The Thin Line II is available with an 18" Pigtail With a 10 conductor cable and a 10 conductor terminal strip. a. Pigtail - Prepare the new cable by cutting the cable jacket back 1-114" and strip the wires '/.". h. Splice the cable and the pigtaii together and seal the splice iftne Thin Line will be an outdoor uniti Trim and cover all conductors that are not used. 5. Terminal Strip - Loosen the terminal strip screws until the top of the screw is flush with the back surface of the Reader. Be careful not turn them further; they are not captive and will fall out. d. Prepare the new cable by cutting the cable jacket back 1-1/4 inches and strip the wire V. ". Twist the ends of the wires to eliminate stray strands. a. Form each wire into a hook and install each wire by wrapping it around the screw. Mount the Reader with the screws provided when mounting on to metal mull/ens orjunction boxes. On other materials use appropriate fasteners. Important Product Specifications Power Requirements Power supply Linear type recommended Operating Voltage Range (+DC) Absolute Maximum (¢DC nonoperatlng) Maximum Average Current 5V/12V Peak Cuflent 5VI12V (maximum) Peak Current 5V/12V (typical non-metallic mounting) Peak Current svnzv (typiml mounted on metal) 4.75VDC 46 OVDC 18.0VDC 40mA/50mA 60mA/1 ZOmA SOmAii OOmA EOmA/‘i ZDmA Operating Parameters Maximum Cable Distance it: Host 500 feet (152 meters) HID Corporation 9292 Jeronimo Road Irvme. CA 92518 USA Web page, E-mail - www.prox.com Thin Line II Reader Installation Manual 5395—902 Rev C TEL (714) 598-1600 (800)237-7769 FAX (714)598-1690 1 of2 Connect the Reader to the Host according to this wiring diagram and the Host installation guide. The legend For wiring is color coded according to the “Vinegand Standard“ for the recommended cable. The numbering for the terminals is shown on the _—Q\ back label and in Figure 2 53 2° 4» .mm~ EH iii“ EH i: ii iii ' These connections are OPTIONAL. All omer connections a.re required. Marking the wires will make future maintenance easier, Cable Notes 1) When using a separate power supply for the Thin Line ii. the power supply and Host should have a common ground (voltage reference), 2) if the Host is controlling the beeper. Hold. or the LEDs are configured for the dual LED mode. additional conductors will be required. The recommended cables are Alpha 12950. 12960. 1297C, 1298C and 12990 that are five, six. seven, eight and nine conductors respectively. Larger wire gauges are acceptable, The wire is to be stranded with an overall shield, either foil or oraided. 3) The Cable shield should be connected to the Shield Ground on Reader TBi - E, and left floating at the panel or power supply end of the cable. This configuration is the best for shielding the reader cable from external interference and reducing the likelihood otthe Reader causing intederence. Testing & Operation of the Thin Line II Reader After wiring the Reader and power supply, the Reader is ready to be tested. 1. Power up the Reader and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay. This indicates that the micro-controller unit is working properly. 2. Present an ID card to the Reader and the LED should momentarily turn green. indicating a read of the card 3‘ If the Reader LED is controlled by the Host refer to the Host description of the LED operation. NOTES: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURESt ALL LOCAL, STATE AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE. HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690 Web page. E-mail -www.pro>ccom Thin Line ll Reader installation Manual 5395-902 Rev C 2 of 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2001:05:26 14:39:24 Producer : Acrobat Distiller 4.0 for Windows Author : jsoscia Title : 51977.pdf Modify Date : 2001:05:26 14:39:29-04:00 Page Count : 6EXIF Metadata provided by EXIF.tools