HIGHSTAR ELECTRICAL HSD7730BR Remote weather station alarm User Manual
Shenzhen Highstar Electrical Co., Ltd Remote weather station alarm
User Manual
Instruction Manual RF433 MHz Remote Weather Station alarm Clock Main Feltures & Fllllctinll .Date, Time, indoor and Outdoor Temperature and Humidity keadout. .12 hours or 24 hours format selection 01 set of alarm setting with snooze function, oSwitching mode of Daylight saving time display. oColor LCD backlight Weather forecast function (Sunny/Sun with Cluudy/Cloudy/Rainy) by indoor/outdoor temperature and humidity data collecting .Maxrmum and minimum temperature and humidity records query. o0utdoor temperature sensor via. 433MHz transmismn(upen space distance greater than 10m). oDegrees Celsius or Fahrenheit selection. Product Illustratlnn Operating Instruction 1.3atteries installltiun adapter connection Open the battery cover, according to polarity symbol to insert 3*AAA battery If batteries inserted properly, the product will self-check and full-screen display automatically, and then display initial time 1200 1 January and generate “Bl" sound at the same time, otherwise, re-install battery accordingly, If symbol “2‘ displayed when use batteries that means battery too low and need to replace new batteries -Altematively, connecting an external Dc zdapler(5V/1A) into the chack, which locates at the back of the unit. -In starting initial state, press “A“ur “v" key to set the current weather conditions, press "MODE" key to Confirm, the indoor device enter to data receiVing state. Remark: rind External DC -It is not necessary tn insert batteries if DC external adapter to be connected. -The battery power is low or external adapter is disconnected. please reset the time and other settings. -Wtien the unit is powered by batteries, the color backlight is OFF. Press Snooze/light button to light up the color backlight display for 20 seconds and then OFF for saving batteries. -The color backlight is always ON by connecting external DC adapter 2.Tlme Setting -In the time display mode, press “SET" key to set Hour, Minute, Year, Month, Day in turn, press “A"or “V" to adjust the blinking item. Weeks follow the mange of Year, Month and Day eLong press the “A”ur .1 V” for fast selection, .Press and hold “V" key about 3 seconds to switch between 12/24 hours format. when sztCh to 12 hours format. moniing hours Without “AM“ display, atternoon hours Wlll display "PM". 3.Alarln Time Setting -In time mode, press the "MODE" key to trigger the time and alarm. eln time mode, press the “MODE" key to enter the alarm made Press the “SET" key tu set the alarm hour, minute. Press ”A“ key or “V" key to adjust the blinking item Press "MODE" key to return. -After finishing the alarm setting,in time mode, press "ALARM" key to turn ON/OFF [he a1arm,when~~ gm .. symbol are shown on display, that the alarm is ON. eWhen the time reaches the preeselling alarm time, there will be ”131131" sound, press any key to stop the alarm. 4.Snooze Setting .Press and hold “swoon" key 3 seconds to turn ON/OFF snooze function -When the snooze Funciton is ON, the display shows “22". .when it reaches the alarm time, the BiBi sound, and press “SNOOZE” key to keep snooze function. “22" symbol is flashing lasting for 50 seconds, and sound every 5 minutes and 5 times in total 5.Daylight Slving Time Mode Press and hold “MODE" key 3 seconds to tuin ON or OFF daylight saving time mode, when daylight saving time mode is on the LCD display “DST' symbol, then the clock incresae 1 hour 5.Temperatnre Mode Setting .Press and hold “A" key 3 seconds to switch change degrees Celsius or Fahrenheit. .Press “A“ key to view the indoor and outdoor maximum and minimum records, .Press and hold “ALARM" key 3 seconds to delete outdoor device data, then the indoor device re-scan to receive the outdoor data. 7.Language Setting This product has 7 kinds of languages to choose Press “SET" key for about 4 seconds to change the language, change the order as follows: English . German . French . Italian . Dutch . Spanish . Danish sszgees ”EEEEF§§- gg===g= Eight-2|“: Soozc>=> g2222>zz ~< _. fi—luZZUE: afim;’a§z;w g2 2Z2 =- 2 2° =m—trl'lh1 Hz SuflwwgmM cc é 5‘ U U —l EEOHQOEO Eczcozmw s4 3-rtfrl<<<<*r1 _. mm H gafizzfimg ~< fimmmmmmr H>>>> §> adage-45mg m GNU EEEEOQOE gzzzzzzz s4 The remote temperature sensor -The sending range is 10 meters rubstules such as wall, concrete, and large metal objects can reduce the range .insert 2*AAA batteries into the outdoor sensor and screw tight the battery cover, and make sure that the indoor unit is powered. -P1ace both units in their desired location/distance, and Wait for 3 minutes [0 ensure that than: is proper reception. If no data is received by indoor unit, check the outdoor device is placed on normal reception range of indoor unit Weather Forecast The weather forecasting feature is for 12 to 24 hours and based solely upon the change of air pressure over time There are 4 possible weather icons that will be shown in the acrylic panel. when £2? light on, indicate weather forecast is Sunny in coming 12 hours When ‘4} " light on, indicate weather forecast is Sun with cloudy in coming 12 hours. when u % ight on, indicate weather forecast is cloudy in coming 12 hours. when “ are" light on, indicate weather forecast is Rainy in coming 12 hours Remark: .Weather forecast will be automatically updated within a certain cycle, users can press the “swoon" key to manually update the forecast indicates, the forecast symbols are lighting in turn and the final LED light will stay the most accurate forecast symbol. .When using an adapter, the forecast indicator light will always ON >When using the battery, press the “SNOOZE” ltey to turn ON the forecast indicator light for 20 seconds, and then turn off Troubleshooting Problem: Hour is incorrect (minute and date are correct). Solution: Be sure correct time zone and daylight saving time settings are selected Prnhlenl: The LCD is faint Solution: Replace the batteries. Problem: No outdoor temperature is displayed Solution: Remove all batteries, rernsert into remote temperature sensor first, then the indoor weather station. Place the remote temperature sensor closer to the indoor unit. Be sure all batteries are fresh Place the remote temperature sensor and indoor unit in position so the straight—line signal is not passing through more than two or three walls Caution -The indoor unit is limited to indooruse -Extreme temperatures, Vibration, shock, moist environment, and immersed in water should be avoided to prevent damage to the units .Ciean displays and units with soft, damp cloth. Do not use solvents or scouring agents, they may mark the displays and casings .immediately remove all iowe powered batteries to avoid leakage and damage FCC Certification Requirements Caution Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) nus device must accept any interference received, including interference that may cause undesired operation. including interference that may cause undesired operation. The manufacturer is not responsible for any radio Ur TV interference caused by unauthorized momflcatwns to this equipment. Such modifications could void the user‘s authority to operate the equipment. This equipment has been tested and found to complywith the limits for a class B digital deVice, pursuant to Part 15 of the FCC Rules These limits are designed to prOVlde reasonable protection against harmful interference in a residential installation This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance Wllh the instmctions, may cause harmful interference to radio communications However, there is no guarantee that interference Wlll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can lie determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures' .. Reuricnl or relocate the receiving antenna -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the Receiver is connected .. Consult the dealer or an experienced radio/TV technician for help,
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 3 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0bb45105-c6f2-4e37-a4a6-fb0206dc62c3 Modify Date : 2014:04:14 11:23:56+08:00 Create Date : 2014:04:14 11:23:55+08:00 Metadata Date : 2014:04:14 11:23:56+08:00 Document ID : uuid:d70fed55-8c29-4546-9564-008f680ee62f Format : application/pdf Creator : Adobe Acrobat 6.0 Producer : Adobe Acrobat 6.0 Image Conversion Plug-inEXIF Metadata provided by EXIF.tools