HON HAI PRECISION IND GPE810U LoRa Express Gateway User Manual Engineering Requirement Specification

HON HAI Precision Ind. Co., Ltd. LoRa Express Gateway Engineering Requirement Specification

Users Manual

Download: HON HAI PRECISION IND GPE810U LoRa Express Gateway User Manual Engineering Requirement Specification
Mirror Download [FCC.gov]HON HAI PRECISION IND GPE810U LoRa Express Gateway User Manual Engineering Requirement Specification
Document ID3393820
Application IDMpJT0TDTe+6rjH/H2yQiPQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize55.51kB (693837 bits)
Date Submitted2017-05-17 00:00:00
Date Available2017-11-14 00:00:00
Creation Date2017-04-19 14:53:34
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2017-04-21 13:55:05
Document TitleEngineering Requirement Specification
Document CreatorMicrosoft® Office Word 2007
Document Author: Mike Chen

GPE810U
Indoor LoRa Gateway
Quick Setup Guide
(GPE810U)
1. Introduction
LoRa indoor gateway is designed to meet the needs of IoT services. This indoor gateway
allow the users to setup this in indoor environment as an aggregator of LoRa sensors to the
internet for the related services. Tomorrow's connected devices will control everything from
indoor temperatures to air conditioner, from the flow of energy through our cities to the flow
of critical healthcare data, unlocking hidden value in unconnected machines. So the
connectivity is critical to generate intelligence, except the WiFi, LoRa is also an alternatively
solution for indoor applications.
Confidential
Page 1
GPE810U
2. Hardware Specifications
Feature
Description
Processor
TI AM3352 ARM Cortex-A8, 1-GHz
Storage
4/8GB eMMC
Memory
DDR3 4Gb
2.4G WiFi
TI WL1831MOD b/g/n single band 2.4G 1T1R
Sensor-LoRa 868 MHz
Semtech FPGA+SX1301 (daughter card)
External Power Jack
12V/1.5A DC_IN
I/O Port
1.RJ45x1, 1 WAN 10/100/1000
2.Reset button x 1
3.USB x 1
4.SMA x 1
Dimension
A x B x C mm (128.9 x 128.9 x 26.2)
Weight
205g
Housing Color
White
3. LEDs Specification
Type
1 Internet
2 Internet
3 Internet
4 Internet
5 WiFi ACT
6 WiFi ACT
7 WiFi ACT
8 WiFi EN
9 WiFi EN
10 LoRa
11 LoRa
12 LoRa
Confidential
Status
Constant Off
Constant Light Red
Constant Light Blue
Blinking Blue
Constant Off
Constant Light Blue
Blinking Blue
Constant Off
Constant Light Blue
Constant off
Constant Light Blue
Blinking Blue
Comment
Physical cable error.
Lrr serv. Connector fixed by Actility is not available.
Lrr serv. Connector fixed by Actility is available.
Data transfer with lrr serv.
Wifi AP is not exist.
Wifi AP is enable.
There is the traffic between Indoor GW and Wireless clients.
Wifi AP and Wifi client are not enable.
The one of Wifi AP and Wifi client is existed.
LoRa radio is off.
LoRa radio is on.
LoRa radio is on and LoRa traffic is transferring.
Page 2
GPE810U
4.Software setup
4.1Use web interface to setup LoRa Indoor GW under Ethernet deployment mode
4.1.1 Power up Indoor LoRa GW
4.1.2 Set PC/NB ether port IPv4 setting in user PC statically for example, 192.168.127.100.
4.1.3 Use PC/NB ether port connect to the Indoor LoRa GW Ethernet port, and then open a
browser to Indoor LoRa GW’s IP (192.168.127.250) to access its web interface. The login
information is like:
Username: bsconfig
Password: aup6g/t;3
Use the hidden webpage to enable Telnet or SSH service on Indoor GW.
http://192.168.127.250/hiddenpage.html
Username : foxcconfig
Password : cj/6c93!
4.1.4 Required a web browser
Chrome version “55.0.2883.87 m” web browser to access Indoor LoRa GW web page.
4.1.5 Connection to Indoor LoRa GW web UI
Confidential
Page 3
GPE810U
4.2. Set WAN interface
Select [WAN] page for setting WAN configuration

WiFi client can be WAN interface, and it is independent from WiFi AP mode.
Confidential
Page 4
GPE810U
4.2.1 Select “Ethernet” as WAN
Use DHCP Mode to get IP address automatically
A. Set Primary WAN type as “Ethernet”
B. Set Ethernet IP Type under Ethernet Settings as “DHCP”
C. Press Apply button

Secondary WAN will be used when Primary WAN is dead.
4.2.3 Use static IP Mode
A. Set Primary WAN type as “Ethernet”
B. Set Ethernet IP Type under Ethernet Settings as “Static”
C. Configure proper settings in IP address / Netmask / Gateway / Primary DNS /
Secondary DNS under Static IP Settings
D. Press Apply button

“NTP” is for users able to setup five NTP server maxmum. GW will query NTP server from the first one
until GW get the response from NTP server.

“LRR log” can upload / export LRR TRACE.log from GW to local user space.
Confidential
Page 5
GPE810U
5. Mechanical and Accessory
5.1 Wall Mount support
This product may provide the optional wall mounting support due to the 3 nuts on its bottom.
For this function, 3 pieces of machine screws shall be used, and the recommended spec is
M3X6mm or others appropriate.
Confidential
Page 6
GPE810U
Confidential
Page 7
GPE810U
Federal Communication Commission Interference
Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
 Consult the dealer or an experienced radio/TV technician for help.
FCC Caution:
 Any changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
 RF Modules installed in this product must not be co-located or operating in conjunction with any
other antenna or transmitters, except when installed in accordance with FCC multi-transmitter
product guidelines.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Country Code selection feature to be disabled for products marketed to the US/CANADA
Confidential
Page 8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : Mike Chen
Create Date                     : 2017:04:19 14:53:34+08:00
Creator                         : Microsoft® Office Word 2007
Modify Date                     : 2017:04:21 13:55:05+08:00
Producer                        : Microsoft® Office Word 2007
Title                           : Engineering Requirement Specification
Has XFA                         : No
Language                        : zh-TW
Tagged PDF                      : Yes
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MCLGPE810U

Navigation menu