HONEYWELL Air Cleaner Manual L1003053

User Manual: HONEYWELL HONEYWELL Air Cleaner Manual HONEYWELL Air Cleaner Owner's Manual, HONEYWELL Air Cleaner installation guides

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadHONEYWELL  Air Cleaner Manual L1003053
Open PDF In BrowserView PDF
Honeywell
OWNER'SGUIDE

F50Fand F300EElectronic
Air Cleaners

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

CONTENTS

Operating Your Electronic Air Cleaner

..............................

Getting the Most from Your Electronic Air Cleaner
Maintaining

Electronic Prefilter(s), Cell(s) and Postfllter(s)

................................

..............................

3

4

6

................................

11

..............................

14

...................................

15

Limited Five-year Warranty

..............................

16

Product Registration

..............................

17

How Electronic Air Cleaning Works
Before You Call for Service
Honeywell

69-0756--05

10-Year UltraClean Coil Guarantee

2

TM

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

OPERATINGYOUR ELECTRONICAIR CLEANER

Turn the On-Off switch on the power box to On.
NOTE:Set the switch to 1 for On and set the switch to 0 for Off.

M3584

The air cleaner now operates whenever your furnace/air
conditioning system fan operates. For maximum air cleaning
benefit and cleaner air conditioner coils, leave the air cleaner
switch turned on at all times and the thermostat fan switch set to
On. Of course, continuous fan operation adds to your electric bill
each month. Check your equipment for the amount of electricity
needed to run your System fan.
When the fan and air cleaner come on, the neon indicator lights.

M6032

You may hear a snapping (electrical arcing) sound occasionally
as the air cleaner operates. This is usually caused by a larger
dust particle that causes a high voltage discharge.The snapping
sound means that your air cleaner is working as it should .To hear
the snapping sound, momentarily press the test button near the
botton of the door. Use the test button any time you want to
prove air cleaner operation.
The switch remains in the On position to keep the air cleaner
running.
When the fan and air cleaner stops, the neon light goes off. The
air cleaner is off until the heating or air conditioning and fan start
again.

M3585A

If you do not want the air cleaner to run, set the On-Off switch to
Off to turn off the air cleaner. Your furnace and air conditioner
continue to operate normally, but without the added benefit of air
cleaning. Normally, this switch should be turn to On at all times.

M3583

3

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

GETTINGTHE MOST FROMYOUR ELECTRONICAIR
CLEANER
Runthe electronicair cleaner as muchas possible
For greatest efficiency, the air cleaner should run all the time. To do this, set the Fan
switch on your thermostat to On, and make sure the air cleaner is turned on. The fan
and air cleaner run even when the furnace or air conditioner is off.
NOTE:

A manual fan switch may be built into the furnace or furnace fan controller.

The air cleaner uses tess power than a 40
single celt model--22 watts). Many believe
the added benefits of full-time air cleaning
feel that the room temperature stays more

watt light bulb (two-celt model--33 watts;
that the added cost is more than offset by
and full-time air circulation. And you may
even when the fan is always on.

Even if your thermostat does not have a Fan On position, you can obtain maximum
available air cleaning benefit by making sure the air cleaner is always turn to On so it
operates whenever the furnace or air conditioner is on.

Keepthe cell(s) and prefilter(s) clean
Although the air cleaner is designed to be efficient over a wide range of cell dirt loading
conditions, regular cleaning is your best assurance of consistent performance. Also, a
very dirty prefilter and celt reduces air flow and, in turn, this reduces the efficiency of
the furnace or air conditioner. The cell wash reminder schedule or the optional W8600
Air Cleaner Indicator should be used to maintain a regular wash schedule.

Replacepostfilter regularly
A high-efficiency postfitter is sometimes installed in the air cleaner. This filter increases
the efficiency of the air cleaner and should be changed every six months of usage.

69-0756--05

4

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

If you have a humidifier
All Honeywell whole house humidifiers can be used in a system with the Honeywell
Electronic Air Cleaner without any additional filters or system modification.
If your system includes an atomizing humidifier, you may want to install a standard
furnace filter between the humidifier and the air cleaner.This filter would keep the
humidifier spray mineral deposits from collecting on the air cleaner.This filter should be
checked regularly and changed when it shows signs of mineral or dirt buildup. If you do
not install a filter, you wilt probably need to wash the cell(s) and prefilter(s) more often
to remove the mineral buildup.
If an ultrasonic room humidifier is used often, especially if filled with tap (undistitted)
water, the celt(s) and prefitter(s) require more frequent washing. A white residue
accumulates on the celt(s) from the minerals in the water. This residue may also
contribute to "white dust." See About lint or "white dust" section for more information.

5

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

CLEANINGPREFILTER(S),CELL(S)AND
POSTFILTER(S)

CAUTION
Sharp edges.
Can cause personal injury.
Carefully handle cell(s) or wear protective gloves to avoid cuts from sharp
metal edges.

Setting a regular cleaningschedule
To ensure optimum performance from the air cleaner, the prefitter(s) and celt(s) must
be cleaned regularly-- twice a year with normal use or more frequently with heavy
use. Use the wash reminder schedule below to help establish and maintain a regular
cleaning schedule. Mount the wash reminder schedule in a convenient location.

ELECTRONtCA

tR

CLEANER

WASH

RE

MINDER

SCHEDULE

INSTAL_TIONOATE;
YEAR

NOTE:

J

F

M

A

M

J

J

A

S

O

N

D

You may let the heating or air conditioning system operate normally while the
cell(s) are being washed. Simply turn off the air cleaner switch.

69-0756--05

6

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

Cleaning your Prefilter
1.

2.

The quickest and easiest way to clean your prefitter is to use the brush attachment of your vacuum cleaner to vacuum the tint off the dirty side of the prefitter.
Greasy dirt may require soaking the prefitter in a tub or rinsing with the garden
hose. Do not wash the prefitter in the dishwasher or car wash
The prefitter should be cleaned every 6 months or more frequently with heavy
use. This wilt keep the prefilter clean of air choking lint that can make your system work harder.

Vacuum the prefilter with a brush attachment, rinse it with a hose, or soak it in a tub.
Do not wash the prefilter(s) in the dishwasher or car wash.

Cleaning your Cells
1.

2.

3.

A quick cleaning of the cells can be done by simply wiping down the ionizer
wires with a damp cloth. This wilt help boost the efficiency of the air cleaner
between full cleaning cycles. Ths quick clean can be done every time the prefilters are cleaned.
A full cleaning of the cells wilt return the air cleaner to its peak efficiency. An easy
way to wash the cells is in a tub of hot, soapy water. Just soak the cells until the
water cools, agitate and rinse. For details on cleaning cells, see below for Washing the cell(s) in a tub or Washing the celt(s) in your automatic dishwasher.
Because the efficiency of the air cleaner remains high even as it loads up with
dirt, a full cleaning of the cells can be put off for yearly maintenance and a quick
cleaning can be done more often. Those wishing to renew to peak efficiency or
with heavier use may want to wash more frequently.

Replacingyour Postfilter
1.
2.

The postfitter is an optional filter that boosts the efficiency of the air cleaner. Do
not wash the postfitter because that wilt neutralize the factory applied charge.
The postfilter should be replaced every six months to ensure peak performance.

7

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

CAUTION
Burn Hazard.
Can cause personal injury.
Allow celt(s) to cool completely in dishwasher and at tend of wash cycle or
wear protective gloves.

Washingthe cell(s) in your automaticdishwasher
Hot water can accumulate
these tubes can drain.

in the tubes supporting the collector plates.Tip the cell(s) so

IMPORTANT
• Check your dishwasher Owner's manual. Some manufacturers do not recommend washing electronic cell(s) in their dishwashers.
• If the dishwasher has upper and lower arms, position the cell(s) carefully to
allow good water circulation.
• Be careful to avoid damaging the cell(s) when placing them in the dishwasher. Broken ionizer wires or bent collector plates are not covered under
the Warranty.
• Very dirty cell(s), especially from tobacco or cooking smoke, can discolor the
plastic parts and the lining of some dishwashers. This discoloration is not
harmful To minimize it, wash the cell(s) more frequently or try a different
brand of detergent.
• Do NOT allow the dishwasher to run through the dry cycle. This bakes on
any contaminants not removed during the wash cycle and reduces air cleaner
efficiency.

1.

Put the celt(s) on the lower rack of the dishwasher with the airflow arrow pointing
up. It may be necessary to remove the upper rack. Do not block water flow to the
upper arm.

HINT: Lay a few large water glasses between the spikes on the lower rack, and rest
the cell(s) on them so the spikes do not damage the aluminum collector blades.
2.

Using your regular dishwashing detergent, allow the dishwasher to run through
the complete wash and rinse cycle. Do not use the dry cycle. To avoid burns,
let the celt(s) coot completely before removing, or wear protective gloves when
removing the cell(s). Remember that water may be trapped inside the cell(s)
plates. Tip the cell(s) so these tubes can drain.

3.

Wipe the ionizer wires and contact board on the end of the cell using your thumb
and forefinger with a small, damp cloth.

4.

Inspect the dishwasher. You may want to rerun the wash and/or rinse cycle with
the dishwasher empty if you see dirt or residue from washing the cell(s). If dirt or
residue seems excessive, wash the cell(s) more often or try a different detergent.

69-0756--05

8

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

CAUTION
Hazardous Chemical.
Can cause personal injury.
Do not splash detergent solution in eyes.

Washingthe cell(s) in a tub
•
•

Wear rubber gloves to avoid prolonged detergent contact with your skin.
Keep detergent and solution out of reach
of children.

NOTE:

1.

Always wash the celt(s) first, then the prefilter(s), to keep heavy prefilter lint
from getting caught in the cell(s).

Use a large enough container, such as a laundry tub or trash container, to hold
one or both cell(s).

NOTE:

Sharp corners on the cell(s) can scratch the surface of a bathtub.

2.

Dissolve about three-fourth cup of automatic dishwasher detergent per cell in
enough hot water to cover the celt(s). If the detergent does not dissolve readily,
or forms a scum on the water, try another brand, or use softened water.

3.

After the detergent has completely dissolved, place the cell(s) in the container
and allow to soak for 15 to 20 minutes or until water cools. Agitate them up and
down a few times and remove. Repeat steps 2 and 3, if necessary, for very dirty
cells.

4.

Next, wash the prefilter(s) the same way. Empty and rinse the wash container.

5.

Rinse the cell(s) with a hard spray of very hot water; rinse the tub clean, then fill
the tub with clean hot water and soak for 5 to 15 minutes. Rinse until the water
draining from the cell(s) and prefilter(s) no longer feels slippery.

6.

Soak cell(s) in a final clear water rinse for ten minutes.

7.

Wipe the ionizer wires and contact board on the end of the cell using your thumb
and forefinger with a small, damp cloth.

9

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

Replacingelectronicair cleanercomponents
1.

Inspect the cell(s) for broken ionizer wires and bent collector plates. Repair, as
necessary, or call your contractor for service.

2.

Slide the prefllter(s)

3.

Slide the air cleaner cell(s) in so the air flow arrow points downstream
handle(s) face outward.

4.

Firmly close the access door.

5.

Turn on the air cleaner. If the celt(s) and prefitter(s) are wet, the neon light may
not come on and you may hear arcing. If the arcing is annoying, simply turn the
air cleaner off for two to three hours or until the cell(s) are dry.

69-0756--05

into the upstream prefilter guides.

10

and the

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

HOWELECTRONICAIR CLEANINGWORKS
A word about particlesize
The particles removed by the electronic air cleaner tend to be very small--less than
ten microns. But what is a ten-micron particle? The eye of an average size sewing
needle is about 750 microns across, and the dot in the i in the word micron is about
400 microns. Generally, particles smaller than ten microns can be seen only with a
microscope, except in very large concentrations, such as a puff of smoke. Your
electronic air cleaner can remove even smaller particles that can be seen only with an
electron microscope.
Although particles one micron and smaller make up only about 20 percent of the total
weight of particles in unfiltered air, they account for over 99 percent of the numbers of
particles.
Because they are so tiny, these particles tend to remain suspended in the air unless
they collide with a solid surface. Then they attach by molecular adhesion and stick like
glue, staining walls and furniture and coating your air conditioning coils. And of course,
some of these particles can cause allergic reactions or simply make the environment
less pleasant.

_,.-.- 749

M6031

11

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

Howthe electronicair cleanerworks
First, large particles (tint, hair) are caught by the prefilter(s). Then, as the dirty air
passes through the intense high voltage electric field surrounding the ionizer wires, all
particles, even the smallest particles down to 0.3 micron are given an electric
charge.The air then passes into the collector where the alternate parallel plates are
charged positive and negative, creating a uniform electrostatic field. Since opposites
attract, the charged particles stick to the collector plates, having an opposite electric
charge.The precharged postfitter continues to remove small 3articles from the air. The
air leaving the air cleaner contains very few particles.

POSTFILTER

---_>

0
0:
DIRTY
AIR

_;
=

IN

IONIZER

"_)'CLEANER
"

___>

,,

AIR
OUT

WIRES

(CHARGING
SECTION

COLLECTOR
(COLLECTOR

PLATES
SECTION)
M6030A

Each time the air circulates through the heating/air conditioning system and air
cleaner, more particles are removed. These particles are generated by normal
household activities and also enter the house from outside. That is the reason we
recommend that you use the air cleaner as much as possible.

Electronic air cleanervs standard furnace filter
The regular furnace filter collects mainly large, visible particles that reach the filter. Its
main purpose is to protect the furnace and air conditioner blower. The electronic air
cleaner collects these large particles plus many of the smaller, mostly invisible
particles. Its purpose is to reduce indoor air pollution as well as to protect the blower,
air conditioning coils and heat exchanger.

69-0756--05

12

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

Ozone and the electronic air cleaner
Electronic air cleaners generate a very small amount of ozone, about 0.005 to 0.010
parts per million (ppm). The amount is highest when the air cleaner is new.
The average person can detect the odor of ozone in concentrations as tow as 0.003 to
0.010 ppm. The U.S. Food and Drug Administration, and Health and Welfare Canada
recommend that indoor ozone concentration should not exceed 0.050 ppm. As a
comparison, the outdoor ozone level in major cities is sometimes higher than 0.100
ppm.
If desired, the ozone generated by the air cleaner can be reduced by asking your
dealer to:
• Install an activated carbon filter downstream of the air cleaner, or
• Adjust the air cleaner power supply to reduce ozone production.This adjustment
reduces ozone production about 20-25 percent, but also reduces air cleaning
efficiency about seven to ten percent.

About lint or "white dust"
White dust is made up of particles that settle out of the air before they get to the return
air duct. You can help prevent this white dust from settling by running your fan
constantly and:
• Be sure the return registers are not blocked with furniture.
• Be sure the discharge ducts are clean (best done before installing the air cleaner).
• Be sure your clothes dryer is vented to the outside and is not plugged.
• If you have new rugs or drapes or new woolen blankets, be aware that the lint from
these items wilt reduce with age.
• In new or remodeled homes, plaster dust or paint pigment may contribute to white
dust, but wilt reduce with time.
• Use of a humidifier may contribute to white dust, especially if filled with undistilled
water.

13

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

BEFOREYOU CALLFOR SERVICE

Electronic air cleaner doesn't seem to be working
1. Make sure the furnace or air conditioner blower is
running.
2. Make sure the access door is firmly closed and latched. If door is not closed
properly, an interlock keeps the air cleaner off.
Arcing (snapping) seems too frequent
1. If the electronic cell(s) are wet from washing, turn the air cleaner off for two to
three hours.
2. Check the celt(s) for broken ionizer wires or bent plates. Repair if necessary.
3. Wash cell(s) and prefilter(s) if dirty.
Neon
1.
2.
3.
4.

light on air cleaner does not come on
Make sure the furnace or air conditioner fan is running.
Make sure the access door is firmly closed.
Make sure the On-Off switch is in the On position.
On models without the Solid State Performance Indicator, if the electronic cell(s)
are wet, check again in two to three hours.
You smell ozone and find it objectionable
Call your heating and air conditioning dealer.

69-0756--05

14

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

HONEYWELL10 YEAR UltraClean COil GUARANTEETM
Guarantee
If yOU properly maintain your new Honeywell Electronic Air
Cleaner (EAC), Honeywell guarantees that if your indoor coil
requires cleaning within the next 10 years, Honeywell will
pay to have it professionally cleaned by a qualified
contractor:
-- 75% of the cost (up to $150) when installed with a
Honeywell Coil Irradiation Ultraviolet Air Treatment System
or
-- 50% of the cost (up to $100)if a Honeywell EAC is installed without a Honeywell
Coil Irradiation Ultraviolet Air Treatment System).
Send to:

Honeywell
10Year
UltraClean
CoilGuarantee
customercare,MNI0-1461
1885 Douglas Drive North
Golden
Valley,MN55422

•

•

•

The UltraClean Coil Guarantee TM applies to any Honeywell Electronic Air Cleaner
properly installed with a heat pump, air conditioner or high efficiency furnace that is:
brand new, tess than one year old; or more than one year old with the indoor coil
professionally cleaned by a qualified contractor prior to installation.
Proper maintenance on the EAC means: keep the power switch in the On position,
periodically verify power operation, and wash electronic cells periodically as
specified in this Owner's Guide.
Proper maintenance on the Electronic Air Cleaner means: periodically clean the
tamp glass and replace UV lamps as specified in the Owner's Guide.

How to register your guarantee
The UltraCtean Coil Guarantee TM begins the day you move into your new home, or the
day the Air Cleaner is installed. To register your guarantee, complete the Registration
Card in the back of this Owner's Guide and enclose:
• Proof of purchase of a Honeywell duct-mounted Electronic Air Cleaner and Coil
Irradiation Ultraviolet Air Treatment System.
• Proof of purchase of a new heating/cooing system within the last year, or...
• Proof of professional coil cleaning services on existing equipment.
• If your home is new and invoices are not available, simply complete the form.

15

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

LIMITED FIVE-YEARWARRANTY
Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and
service, for a period of five (5) years from the date of purchase by the consumer. If, at any time during the
warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's
option) within a reasonable period of time.
If the product(s)
a.
b.

is defective,

please contact:

dealer where you purchased it, or
local Honeywell Authorized Repair Station.

If you do not have a dealer, locate one in your area at www.honeywell.com/yourhome/.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by
Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the
possession of a consumer.
Honeywell's sole responsibility shall be repair or replace the product within the terms stated above.
HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY
BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation
may not apply to you.
THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE, AND HONEYWELL EXPRESSLY DISCLAIMS
ALL OTHER WARRANTIES,
WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY, INCLUDING BUT
NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY,
WORKMANSHIP, OR FITNESS FOR A
PARTICULAR PURPOSE.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this product or warranty, please write to Honeywell Customer Care, 1985
Douglas Dr. N, MN 10-1461, Golden Valley, MN 55422. In Canada, write to Honeywell Limited/Honeywell
Limitee, 36 Dynamic Drive, Scarborough, Ontario, MIV 4Z9.

Warranty Registration
Register your warranty on-line at www.honeywell.com/yourhome/under
following form to:
Honeywell Customer Care
MN10-1461
1885 Douglas Dr N
Golden Valley, MN 55422

69-0756--05

16

Product Registration

or send the

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

ProductRegistration
(Register online @ www.honeywell.com/yourhome)
1. Mr
Mrs
Ms
Miss
First Name:
Initial:
Address (Number and Street):
Zip or Postal Code
City:.
email Address:
2.

Last Name:
Apt:
State/Province:

Phone Number:

3. Date of Purchase (month/day/year)
Purchase Price: $

ex: January/18/98:
.(excluding tax)

4. Where did you purchase this Honeywell product:
Heating/cooling contractor
Utility company.
Builder/came with new home
Other
5.

Model Number

6. How many other Honeywell products do you own:
None
One
Two
Three
Four or more
7.

Your date of birth (month/day/year)

ex. January/18/69:

8.

Education: High School
Some College
Technical School
Completed College
Graduate School
Other

9. For your primary residence, do you:
Own
Rent
10.

Including yourself, what is the total number of people
living in your household? (Ex. 01, 02, 03 ... xx):

11.

Your marital status: Married

12. Which bestdescribes
Under$15,000515,000$25,000__$35,000
$100,000- $149,999

Single

yourfamityincome?
$24,999
$50,000575,000
OverS150,000

17

69-0756--05

F50F AND F3OOE ELECTRONIC

AIR CLEANERS

Honeywell10 Year UltraClean Coil GuaranteeTM

Your Name
Street Address
City
Phone: Day.
emait
Date you moved in (for new home).

State
Evening

Please check UltraClean Coil Guarantee
details for explanation):
[3 UltraClean Coil Guarantee TM.
[3 Clean Coil Guarantee TM.

Your heating/cooling
Street Address:
City
Phone:

TM

Zip Code

Attn Mailroom: Please direct to Customer

69-0756--05

or Clean Coil Guarantee

contractor or builder
State

18

Zip Code

Care, MN10-1461.

TM

(see program

F50F AND F3OOE ELECTRONIC

19

AIR CLEANERS

69-0756--05

F50F AND F3OOE ELECTRONIC

Automation

AIR CLEANERS

and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN 55422

Toronto, Ontario

Limitee

M1V 4Z9

yourhome.honeywell.com
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer
paper fibers.
® U.S. Registered

Trademark

© 2006 HoneywelI International Inc.
69-0756--05
J.Z. Rev. 06-07

Honeywell



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 20
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 4, 0, 0, 13
Create Date                     : Fri Mar 12 04:15:26 2010
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu