 Installation instructions1HDE 16.06.2011  Dimensions in mmDialock DT LiteInstallation instructions................................................ 2
HDE 16.06.2011  Dimensions in mm21.  Notes on these installation instructions1.1  Contents and target group of the instructionsIt is essential to pay attention to these instructions in order to install the product successfully and safely. Please pay attention to all of the specified installation steps, instructions and notes! These installation instructions are intended for:•  the operator of the product,•  the installer of the product.In addition to these installation instructions, both groups of people must also have read the separate operating instructions before handling the product.1.2  Obligations of the installerThe installer has the following obligations:•  All notes and specifications in the installation instructions must be complied with. The installation steps must not be deviated from or varied. •  Only the supplied original parts must be installed.•  The installation instructions must be handed to the operator after installation has taken place.1.3  Obligations of the operatorThe operator has the following obligations:•  The installation requirements must be complied with.•  The product may only be installed and started up by qualified experts (see Chapter “1.3 Personnel qualifications“ in the operating instructions).•  The instructions must be kept until the product is disposed of, and handed to the new operator in the event of a change of operator.1.4  Technical Data Power Supply:  6VDC by 4 AA BatteriesPower Input:  max. 70mAOperation Frequency: 13,56 MHzModulation Type ASKAntenna Type Loop AntennaNumber of Channel 1Operation Temperature -10°C to 60°CReading Range 0 - 40mm2.  Installation requirements2.1  AmbientconditionsIn addition to the ambient conditions specified here, the instructions in the chapter entitled “2.1 Correct purpose of use“ in the operating instructions also apply.NOTEThe product may be damaged if it is installed under the wrong ambient conditions! The products must not be installed:>  on exterior doors,>  in humid environments,>  in the vicinity of electromagnetically sensitive devices,>  in potentially explosive environments.Installation instructions
HDE 16.06.2011  Dimensions in mm32.2  Installation conditionsDoor leaf•  Possible door leaf thicknesses: 38 - 80 mm,•  Possible door materials: Wood and wooden materials, metal only after prior consultation with Häfele.Mortise•  The mortise must be present, and must comply with the dimensioned drawing “Installation requirements“ on page 7.Suitable screw-in cylinder for emergency opening•  The screw-in cylinder for emergency opening is not included in the scope of delivery and must be ordered separately by the operator.•  The size of the screw-in cylinder depends on the door leaf thickness.•  For help in calculating the length, see “Installation requirements“ on page 7.3.  Check scope of delivery•  Check completeness and condition of scope of delivery prior to installation.•  If parts are missing or damaged, contact the manufacturer.•  Dispose of packaging materials in accordance with national regulations.NOTEThe product can be damaged by water condensing on cold components!>  Before installation, please ensure that all product components are at ambient temperature! >  Store products at the installation site for an appropriate period prior to installation.NOTEThe product may be damaged if the screw-in cylinder is used in-correctly!The screw-in cylinder is for emergency opening only.>  Do not use the screw-in cylinder for normal door locking / opening! WARNINGRisk of suffocation from small parts and packing materials!Screws, small parts and packing materials can be deadly playthings for children.>  Do not leave the packing materials and the contents lying around carelessly, and keep away from children and babies.>  Keep children away from the installation site during installation.For overview of scope of delivery, see illustrations starting on page 6.
HDE 16.06.2011  Dimensions in mm44.  Installation4.1  Safety instructions for installation4.2  InstallationdescriptionThe installation is described using only pictures.WARNINGRisk of fatality due to lack of emergency opening facility!If the product is installed without an emergency opening facility, it may not be possible to open the door from the outside in the event of fault. If emergencies occur inside the room during the fault, rescue work will be hindered.>  The operator must ensure that doors to which this product is fitted have an emergency opening facility in the event of faults.>  Häfele is not liable for damage that is attributable to failure to install an emergency opening facility.WARNINGRisk of fatality due to failures or faults in electromagnetically sensitive devices!The electromagnetic radiation of the product can cause faults in sensi-tive parts (e.g. in medical equipment). The functionality thereof will be adversely affected.>  Do not mount product close to electromagnetically sensitive devices.>  Pay attention to the safety instructions for the electromagnetically sensitive devices.>  If you have any doubts regarding compatibility, please contact the manufacturer.NOTEDamage to product due to incorrect installation!>  Adhere to installation requirements.>  Do not jam or damage wires during installation.>  Never start up and use the product if any wires have been damaged.>  Always drill holes in the door leaf from both sides to prevent pieces of the door from breaking away.For step-by-step installation instructions, see picture sec-tion starting at page 8.
HDE 16.06.2011  Dimensions in mm54.3  Function test After completing installation, perform a manual function test.Push the lever handle at the inside of the door:Correct result:•  Turning the DND thumbturn counter-clockwise makes the deadbolt move out.•  When the interior handle is pressed, the latch and the deadbolt are retracted. The door can be opened.Push the lever handle at the outside of the door: Correct result:•  The lever handle is blocked. The door can not be opened.If this is not the case, check the individual installation steps.4.4  FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: PW3PW3204CAUTIONThe manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifi-cations could void the user authority to operate the equipment.
HDE 16.06.2011  Dimensions in mm6JM N O PKLDF EGHI C B AScope of delivery
HDE 16.06.2011  Dimensions in mm71279 mm62,5 mm19 mm70 mm140 mm29 mm31 mm26 mm215 mm45,3 mm98,5 mm30,5 mmØ 40 mmØ 40 mmØ 25 mmØ 14 mmØ 14 mmØ 3 mmØ 3 mmØ 3 mmØ 3 mmØ 25 mm259,5 mm216 mm141 mm90 mm120 mm101 mmInstallation requirements
HDE 16.06.2011  Dimensions in mm82331425DEC312BInstallation
HDE 16.06.2011  Dimensions in mm94ONMP123445123444FGKPay attention to correct polarity!
HDE 16.06.2011  Dimensions in mm1061233IHJ
HDE 16.06.2011  Dimensions in mm11
Häfele GmbH & Co KG · Postfach/B.O. Box 1237 · D-72192 Nagold · Phone +49 (0) 74 52 / 95-0 · info@haefele.de · www.hafele.comHDE 16.06.2011  Dimensions in mm       732.29.493