Hager 5200_p2 4_8_8_06 5200 Series Door Closer Installation Instructions Installationi Cl00187
User Manual: Hager 5200 Series Door Closer Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
5200 Series Door Closer Installation Instructions I-CL00187 R2 An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These installation instructions should be followed to avoid the possibility of misapplication or misadjustment. Regular Arm Installation See Page 2 Left Hand Door - LH Right Hand Reverse - RHR Parallel Arm Installation See Pages 3&4 Left Hand Door - LH Right Hand Reverse - RHR Regular Arm Installation See Page 2 Right Hand Door - RH Left Hand Reverse - LHR NOTE: For special applications, a separate door and frame preparation template is packed with these instructions. Use this instruction sheet for installation sequence and closer adjustments only. • Dimensions are based on standard doors and frames with 1/8" clearance, 5/8" stops, and square edge doors. • Door and frame must be properly reinforced. • Non-Handed Door Closers. Parallel Arm Installation See Pages 3&4 Right Hand Door - RH Left Hand Reverse - LHR NOTE: For Top Jamb Application Top Jamb Installation See Page 5 A longer connecting rod is required for reveals greater than 3" (76 mm) Left Hand Door - LH Right Hand Reverse - RHR Top Jamb Installation See Page 5 Reveal Right Hand Door - RH Left Hand Reverse - LHR • These door closers should NOT be installed on the exposed side (weather side) of exterior doors. METAL TOOLS REQUIRED WOOD Self Drilling Screws Wood and Metal For wood, drill 3/16" hole Drill 9/32" thru from Closer Side 3/8" Drill other Side Machine Screws 3/16" #7 Sleeve Nut and Bolt #7 Drill, 1/4"- 20 Tap 1/4"- 20 Check building and fire codes to see if your application requires the use of sleeve nuts and bolts. COMPONENT PARTS BACKCHECK VALVE POWER ADJUSTMENT SHAFT REGULAR ARM/TOP JAMB SHOE INSERT CUTOUTS COVER INSERT MAIN ARM LATCH VALVE FOREARM SCREW CLOSER BODY SWEEP VALVE HAGER COMPANIES PARALLEL ARM BRACKET CONNECTING ROD CLOSER COVER CLOSER ARM 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 SCREW PACK 5200 Series Door Closer - Regular Arm Installation Instructions I-CL0087 R2 1. PARTS 2. MARK AND DRILL HOLES ( Right Hand Shown) 1-3/4" (44 mm) 5-1/2" (140 mm) A 1-3/8" 3/4" (35 mm) (19 mm) Door Opening Dimension “A” To 100 7-1/2" (191 mm) 101 to 130 6" (152 mm) 131 to *180 4-1/2" (114 mm) 1" (25 mm) 12" (305 mm) *Door/Wall/Hardware/Jamb conditions permitting Speed regulating valves toward hinge edge 3. INSTALL CLOSER Select hand of door and degree of door opening. Fold template on the corresponding line for desired degree of door opening and hand. Match this line with the hinge edge of door and attach template to door. Be sure frame line on template lines up with the bottom edge of frame face. Mark, prep and drill/tap 1/4"-20 holes for closer body and jamb shoe mounting screws. 4. INSTALL MAIN ARM 5. INSTALL MAIN ARM AND CONNECTING ROD FRAME RIGHT HAND DOOR 90 RIGHT ANGLE L R H PINION FLAT POSITION OF MAIN ARM WHEN ASSEMBLING TO SPINDLE Remove template and use mounting screws to install the closer body to the door and the jamb shoe to the frame. Closer body should be oriented so that the speed regulating valves are toward the hinge stile of door. Orient main arm so that the “H”, located on the main arm, lines up with the flat on the spindle. Press arm down on spindle and secure with spindle bolt. 6. OPTIONAL HOLD-OPEN ARM 7. ADJUSTMENTS Identify direction of hold-open nut according to hand of door and mount arm. RH LH 8. INSTALL COVER See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. COVER Slide cover over closer body and secure by tightening screws. Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES Slide connecting rod into forearm of main arm. Rot n down forearm screw. 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 2 5200 Series Door Closer - Parallel Arm Installation Instructions I-CL00187 R2 1. PARTS 2. MARK AND DRILL HOLES ( Right Hand Shown) 2-3/4" (70 mm) 3/8" (10 mm) 2" A (Center on Hinge) B Top of Door (51 mm) 1/2" (13 mm) 7/16" (11 mm) Frame 3-1/2" (89 mm) Door Opening Select hand of door and the degree of door opening. Fold template on the corresponding line 3-3/4" 9-1/2" To 120 for desired degree and hand. Fold or cut upper (241mm) (95mm) corner illustrated on template and align template 1-1/4" 7" with the hinge edge of door. At the “Frame Stop *121 to 180 (178mm) (32mm) Line” fold toward you and attach template to door. Mark, prep and drill/tap 1/4"-20 holes for closer *Door/Wall/Hardware/Jamb body and parallel arm bracket mounting screws. conditions permitting 3. INSTALL CLOSER 3/4" (19 mm) 12" (305 mm) (Center on Hinge) Speed regulating valves toward lock stile 4. INSTALL CONNECTING ROD Remove template and use mounting screws to install the closer body to the door and the parallel arm bracket to the frame soffit. Closer body should be oriented so that the speed regulating valves are toward the lock stile of door. CONNECTING ROD For parallel arm application only, remove regular arm / top jamb shoe. Attach connecting rod to the parallel arm plate. 5. INSTALL MAIN ARM Ro tate 45 ˚ Use adjustable wrench to rotate spindle 45˚ counterclockwise for Right Hand Door or clockwise for Left Hand Door. Place main arm on spindle so that the “R” (Right Hand Door) or “L” (Left Hand Door) lines up with the spindle flat. Secure main arm and spindle by tightening spindle bolt. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 3 5200 Series Door Closer - Parallel Arm Installation Instructions I-CL00187 R2 6. INSTALL MAIN ARM AND CONNECTING ROD a) Slide connecting rod into forearm of main arm. b) c) 1-1/2" (38 mm) 1-1/2" (38 mm) While holding arm in this position, tighten down forearm screw. Rotate main arm until the pivot point is 1-1/2" from door surface. 7. OPTIONAL HOLD-OPEN ARM 8. ADJUSTMENTS Identify direction of hold-open nut according to hand of door and mount arm. LH 9. INSTALL COVER See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. RH COVER Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES Slide cover over closer body and secure by tightening screws. 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 4 5200 Series Door Closer - Top Jamb Arm Installation Instructions I-CL00187 R2 1. PARTS 2. MARK AND DRILL HOLES (Right Hand Shown) 12" (305 mm) 3/4" A Door Opening (19 mm) Top of Frame 1-7/8" (48 mm) 1-3/4" (44 mm) 5-1/2" (140 mm) To 100 7-1/2" (191 mm) 101 to 130 6" (152 mm) 131 to *180 4-1/2" (114 mm) Select hand of door and the degree of door opening. Separate template sections “A” and “B”. Fold template on the corresponding line for desired degree and hand. Match this line with the hinge edge of door and attach template to door. Be sure “Frame” line on template lines up with the top edge of door. Using a square, project “Closer Projection Line” on section “A” of template onto frame and use to align and attach section “B”. Be sure to align bottom edge of section “B” with edge of frame. Mark, prep and drill/tap 1/4"-20 holes for connecting rod shoe and closer body mounting screws. *Door/Wall/Hardware/Jamb conditions permitting 1/2" (13 mm) A longer connecting rod is required for reveals greater than 4" (102 mm) Speed regulating valves toward hinge edge 3. INSTALL CLOSER Dimension “A” Reveal 5. INSTALL MAIN ARM AND CONNECTING ROD 4. INSTALL MAIN ARM 90 RIGHT ANGLE RIGHT HAND DOOR CONNECTING ROD FRAME MAIN ARM L R H PINION FLAT POSITION OF MAIN ARM WHEN ASSEMBLING TO SPINDLE Remove template and use mounting screws to install the closer body to the top jamb and the connecting rod shoe to the door. Closer body should be oriented so that the speed regulating valves are toward the hinge stile of door. MAIN ARM Orient main arm so that the “H”, located on the main arm, lines up with the flat on the spindle. Press arm down on spindle and secure with spindle bolt. 6. OPTIONAL HOLD-OPEN ARM 7. ADJUSTMENTS Identify direction of hold-open nut according to hand of door and mount arm. See Adjustments on Page 6 for setting Spring Power, Sweep Speed, Latch Speed, and Backcheck. Slide connecting rod into forearm of main arm. Rotate main arm until connecting rod is at a 90˚ angle to frame. While holding arm in this position, tighten down forearm screw. 8. INSTALL COVER COVER NOTE: Do not fully unscrew valves or hydraulic fluid will leak and closer will no longer be functional. LH Slide cover over closer body and secure by tightening screws. RH Adjust by loosening hold-open nut, then open door to desired position and tighten hold-open nut securely. HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 5 5200 Series Door Closer - Adjustments Installation Instructions I-CL00187 R2 ADJUSTMENTS (USE 5/32" HEX WRENCH FOR THESE ADJUSTMENTS) SWEEP SPEED LATCH SPEED OPTIONAL DELAY ACTION BACKCHECK S S S L L L Note: Adjust closing time speed to between 3 and 7 seconds from 90˚ to 0˚. Greater closing times may be required for elderly or handicapped. Adjust backcheck accordingly to prevent excessive opening speed. Adjust latch speed so door completely closes and latches. Adjust delay action accordingly to obtain desired delay time. SPRING POWER ADJUST (Sizing in accordance to BHMA/ANSI 156.4) TABLE OF SIZES Closer is shipped set to size 3. To change the closer size, use a hex wrench to rotate the spring power adjust. Follow the chart to make the correct numbers of 360° turns to set the closer size appropriately for the door application. The number of turns is an approximation and does not account for environmental or door hardware affects. Approx. 5 turns to increase/decrease one size. (Use 5/32" Hex Wrench for this adjustment) cw = clockwise ccw = counterclockwise ADJUSTMENT DIAGRAM Exterior (and Vestibule) Door Width Minimum Door Width (24") 24" - 30" - 36" - 42" - 48" (610 mm) (762 mm) (914 mm) (1067 mm) (1219 mm) Regular Arm & Size 3 Size 4 Size 5 Size 6 (0) (4cw) (8cw) (12cw) Top Jamb Parallel Arm Size 3 Size 4 Size 5 (4cw) (8cw) (12cw) Interior Door Width Minimum Door Width (24") 24" - 30" - 34" - 38" - 48" - Regular Arm & Top Jamb Parallel Arm Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 (4cw) (8cw) (12cw) (8ccw) (4ccw) (0) Size 1 Size 2 Size 3 Size 4 Size 5 (4ccw) (0) (4cw) (8cw) (12cw) ARM PLACEMENT IN SHOE 7-1/2% Stronger Y DELA or or 7-1/2% Weaker HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149 6 54" - 60" (610 mm) (762 mm) (865 mm) (965 mm)(1219 mm)(1372 mm) (1524 mm)
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Producer : Adobe PDF library 6.66 Creator Tool : Illustrator Modify Date : 2017:07:12 17:15:16-05:00 Create Date : 2011:10:28 13:55:35-06:00 Metadata Date : 2017:07:12 17:15:16-05:00 Thumbnail Format : JPEG Thumbnail Width : 192 Thumbnail Height : 256 Thumbnail Image : (Binary data 21693 bytes, use -b option to extract) Document ID : uuid:e78d1e14-b918-4cc5-80b3-7b21e0c626fe Instance ID : uuid:4dc677d4-cd8a-4586-867d-cfcacaec2742 Format : application/pdf Title : 5200_p2-4_8_8_06.ai Creator : rwilkins Page Count : 6 For : Windows XP Mode, Hager Bounding Box : 30 23 580 765 Container Version : 9 Creator Version : 11 Author : rwilkins Image Height : 742 Image Width : 550 Image Size : 550x742 Megapixels : 0.408EXIF Metadata provided by EXIF.tools