Hangzhou Hikvision Digital Technology KD3002VM Video Intercom Door Station User Manual

Hangzhou Hikvision Digital Technology Co., Ltd. Video Intercom Door Station Users Manual

Users Manual

Video Intercom Door Station (D  Series) Quick Start Guide Certification
Video Intercom Door Station·Quick Start Guide . Quick Start Guide ©2017 Hangzhou Hikvision Digital Technology Co., Ltd.   This quick start guide is intended for users of the models below: Series Model Door Station (D Series)  DS-KD3002-VM It includes instructions on how to use the Product. The software embodied in the Product is governed by the user license agreement covering that Product. About this Manual This Manual is subject to domestic and international copyright protection.    Hangzhou Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision.   Trademarks   and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, REGARDING THIS MANUAL. HIKVISION DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE WHOLLY AT YOUR OWN RISK AND RESPONSIBILITY.   TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, SECURITY BREACHES, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF OR RELIANCE ON THIS MANUAL, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Video Intercom Door Station·Quick Start Guide SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY OR CERTAIN DAMAGES, SO SOME OR ALL OF THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. Support Should you have any questions, please do not hesitate to contact your local dealer. Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.2. This device must accept any interference received, including interference that maycause undesired operation.3 ISED RSS Warning: This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence.   L'exploitation est autorisée aux deux conditions suivantes:   (1) l'appareil ne doit pas produire de brouillage, et   (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Video Intercom Door Station·Quick Start Guide 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Warnings and Cautions: Warnings: Neglecting any of the warnings may cause serious injury or death.Cautions: Neglecting any of the cautions may cause injury or equipment damage. WarningsThe working temperature of the device is from -40º C to 60º C.All the electronic operation should be strictly compliance with the electrical safetyregulations, fire prevention regulations and other related regulations in your localregion.Please use the power adapter, which is provided by normal company. The powerconsumption cannot be less than the required value.Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard.Please make sure that the power has been disconnected before you wire, install ordismantle the device.Warnings Follow these safeguards to prevent serious injury or death. Cautions Follow these precautions to prevent potential injury or material damage. 4
Video Intercom Door Station·Quick Start Guide 5 When the product is installed on wall or ceiling, the device shall be firmly fixed.If smoke, odors or noise rise from the device, turn off the power at once and unplugthe power cable, and then please contact the service center.If the product does not work properly, please contact your dealer or the nearestservice center. Never attempt to disassemble the device yourself. (We shall notassume any responsibility for problems caused by unauthorized repair ormaintenance.)CautionsDo not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface orplaces subject to shock (ignorance can cause equipment damage).Do not place the device in extremely hot (refer to the specification of the device forthe detailed operating temperature), cold, dusty or damp locations, and do notexpose it to high electromagnetic radiation.The device cover for indoor use shall be kept from rain and moisture.Exposing the equipment to direct sun light, low ventilation or heat source such asheater or radiator is forbidden (ignorance can cause fire danger).Do not aim the device at the sun or extra bright places. A blooming or smear mayoccur otherwise (which is not a malfunction however), and affecting the endurance ofsensor at the same time.Please use the provided glove when open up the device cover, avoid direct contactwith the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover.Please use a soft and dry cloth when clean inside and outside surfaces of the devicecover, do not use alkaline detergents.
Video Intercom Door Station·Quick Start Guide 6 Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper.Transportation without the original wrapper may result in damage on the device and lead to additional costs.Improper use or replacement of the battery may result in hazard of explosion.Replace with the same or equivalent type only. Dispose of used batteries according tothe instructions provided by the battery manufacturer.Table of Contents 1 Appearance .................................................................................................. 1 1.3 Appearance of DS-KD3002-VM ................................................................................ 3 2 Terminal and Wiring ..................................................................................... 5 2.1 Terminal Description ................................................................................................ 5 2.1.2 Terminals and Interfaces of DS-KD3002-VM ..................................................... 7 2.2 Wiring Description ................................................................................................... 9 2.2.1 Door Lock Wiring .............................................................................................. 9 2.2.2 Door Magnetic Wiring ....................................................................................... 9 2.2.3 Exit Button Wiring ........................................................................................... 11 2.2.4 External Card Reader Wiring ........................................................................... 12 2.2.5 Alarm Device Input Wiring .............................................................................. 14 2.2.6 Alarm Device Output Wiring ........................................................................... 15 3 Installation ................................................................................................. 17 3.3 Installation of DS-KD3002-VM ............................................................................... 23 3.3.1 Gang Box for DS-KD3002-VM .......................................................................... 23 3.3.2 Wall Mounting with Gang Box of DS-KD3002-VM ........................................... 23 4 Before You Start ......................................................................................... 26 5 Local Operation .......................................................................................... 27 5.1 Keys Description ..................................................................................................... 27 5.2 Activating Device .................................................................................................... 27 5.3 Editing Network Parameters .................................................................................. 29 5.4 Changing Password ................................................................................................ 30 5.5 Calling Resident ..................................................................................................... 32 5.6 Unlocking Door ...................................................................................................... 33 6 Remote Operation via Batch Configuration Software ................................. 34 6.1 Activating Device Remotely ................................................................................... 34 6.2 Editing Network Parameters .................................................................................. 35 6.3 Adding Device ........................................................................................................ 36 6.3.1 Adding Online Device ...................................................................................... 36 6.3.2 Adding by IP Address ........................................................................................ 37
Video Intercom Door Station·Quick Start Guide 7 Appendix ...................................................................................................... 39 Installation Notice ....................................................................................................... 39 Wiring Cables .............................................................................................................. 39 4  LCD Display Screen 5  Card Induction Area 6  Keypad 7  Call Button 8  Call Center Key 9  Microphone 10 TAMPER TAMPER No.  Description 1  Low Illumination Supplement Light 2  Built-in Camera 3  Loudspeaker Table 1-3 Descriptions Keys
Video Intercom Door Station·Quick Start Guide 8 2.1.2 Terminals and Interfaces of DS-KD3002-VM Figure 2-2 Terminals and Interfaces of DS-KD3002-VM Table 2-2 Descriptions of Terminals and Interfaces Name  No.  Interface  Description USB  1  USB  USB Interface LAN  2  LAN1  Network Interface 3  LAN2  Analog Interface Power Supply  4  DC 12V  DC 12V Power Supply Input READER A1 12V  Power Supply Output A2  GND  Grounding A3 W1 Data Input Interface Wiegand Card Reader: Data1 A4 W0 Data Input Interface Wiegand Card Reader: Data0 A5 BZ  Card Reader Buzzer Output A6  ERR  Card Reader Indicator Output (Invalid Card Output) A7 OK Card Reader Indicator Output (Valid Card Output) A8  TAMP  Tamper-proof Input of Wiegand Card Reader ALARM  B1  AO2-  Alarm Relay Output 2
Video Intercom Door Station·Quick Start Guide 9 2.2 Wiring Description 2.2.1 Door Lock Wiring Name  No.  Interface  Description OUT  B2  AO2+ B3  AO1-  Alarm Relay Output 1 B4  AO1+ DEBUG B5  GND  Grounding B6 RX  Serial Port Debugging/Receive data B7 TX  Serial Port Debugging/Send data B8  3.3V  Serial Port Debugging/Power Supply DOOR C1 12V  Power Supply Output C2  GND  Grounding C3  NC2  Door Lock Relay Output (NC) C4  COM2  Grounding Signal C5  NO2  Door Lock Relay Output (NO) C6  NC1  Door Lock Relay Output (NC) C7  COM1  Grounding Signal C8  NO1  Door Lock Relay Output (NO) RS485 D1  GND RS-485 Communication Interfaces D2 485- D3 485+ ALARM IN D4  GND  Grounding Signal D5  AI4  Alarm Input 4 D6  AI3  Alarm Input 3 D7  AI2  Alarm Input 2 D8  AI1  Alarm Input 1
Video Intercom Door Station·Quick Start Guide Figure 2-3 Door Lock Wiring Terminal NC1/COM1 is set as default for accessing magnetic lock/electric bolt;terminal NO1/COM1 is set as default for accessing electric strike.To connect electric lock in terminal NO2/COM2/NC2, it is required to set the output ofterminal NO2/COM2/NC2 to be electric lock with Batch Configuration Tool oriVMS-4200.Door Magnetic Wiring for DS-KD3002-VM Figure 2-6 Door Magnetic Wiring for DS-KD3002-VM 2.2.2 Door Magnetic Wiring 10
Video Intercom Door Station·Quick Start Guide 11 To connect the door magnetic, it is required to set the output of terminal AI2 to be door magnetic with Batch Configuration Tool or iVMS-4200. 2.2.3 Exit Button Wiring  Exit Button Wiring for DS-KD3002-VM Figure 2-9 Exit Button Wiring for DS-KD3002-VM Terminal S1 is set as default for connecting exit button. 2.2.4 External Card Reader Wiring
Video Intercom Door Station·Quick Start Guide 12 Please set the DIP switch first before connecting the card reader.If the DIP switch should be configured when the card reader is power-on, please reboot the card reader after configuring the DIP switch.The DIP switch description is shown in the following table:No. Description How to Configure 1-4 Set the RS-485 address ON: 1 OFF: 0 6 Select Wiegand protocol or RS-485 protocol ON: Wiegand OFF: RS-485 7 Set the Wiegand protocol (It is invalid when setting OFF in 6.) ON: Wiegand 26 OFF: Wiegand 34 RS-485 Card Reader Wiring Figure 2-10 RS-485 Card Reader Wiring
Video Intercom Door Station·Quick Start Guide 13 Wiegand Card Reader Wiring Figure 2-11 External Card Reader Wiring 2.2.5 Alarm Device Input Wiring  Alarm Device Input Wiring for DS-KD3002-VM Figure 2-13 Alarm Device Input Wiring for DS-KD3002-VM 2.2.6 Alarm Device Output Wiring
Video Intercom Door Station·Quick Start Guide Alarm Device Output Wiring for DS-KD3002-VM Figure 2-15 Alarm Device Output Wiring for DS-KD3002-VM 3 Installation Before you start: Make sure the device in the package is in good condition and all the assembly parts are included.The power supply the door station supports is 12 VDC. Please make sure your powersupply matches your door station.Make sure all the related equipment is power-off during the installation.Check the product specification for the installation environment.3.3 Installation of DS-KD3002-VM 3.3.1 Gang Box for DS-KD3002-VM Figure 3-12 Front and Side View 14
Video Intercom Door Station·Quick Start Guide 15 The dimension of gang box for model DS-KD3002-VM door station is: 343(length)×113(width)×55(depth) mm.The dimensions above are for reference only. The actual size can be slightly differentfrom the theoretical dimension.3.3.2 Wall Mounting with Gang Box of DS-KD3002-VM Steps: 1. Chisel a hole in the wall for inserting the gang box. The size of the hole should be larger than that of the gang box. The suggested size of hole is 343.5 (length) × 113.5 (width) × 55.5 (depth) mm. 2. Insert the gang box into the hole and fix it with 4 PA4 screws.
Video Intercom Door Station·Quick Start Guide 16 ScrewScrewFigure 3-13 Insert the Gang Box into the Wall 3. Make sure the edges of the gang box align to the wall.4. Route the cables of the door station through the cable hole.5. Put the door station into the gang box.Figure 3-14 Install the Door Station 6. Fix the door station to the gang box with 4 crews.
Video Intercom Door Station·Quick Start Guide 17 Figure 3-15 Tighten the Screws of Device 4 Before You Start For the first time use of the device, you are required to activate the device and set the activation password. You can activate the device via internet with Batch Configuration Tool, or with iVMS-4200 client software. To activate the device with Batch Configuration Tool or iVMS-4200, refer to 6.1 Activating Device Remotely.   To activate the device locally, refer to 5.2 Activating Device. To configure the key parameters of device on the user interface of door station, you are required to input the admin password. Here the admin password refers to the configuration password.   The default admin password (configuration password) is 888999. You can set the login password of the device by yourself. You must change the default credential to protect against unauthorized access to the product. Please refer to 5.4 Changing Password. 5 Local Operation
Video Intercom Door Station·Quick Start Guide 18 5.1 Keys Description Key descriptions of door stations are illustrated in Table 5-1. Table 5-1 Key Descriptions 1 Key Description Numeric Key 2 ▲ Numeric Key 4 ▼ Numeric Key 6 ◄ Numeric Key 8 ► # Call Key (When calling residents or center) Confirm * Return Delete 5.2 Activating Device You cannot use the door station until you activate it. Steps: 1. Power on the door station to enter the activation interface automatically.Figure 5-1 Activate the Device (Option 1) 2. Press the # key.
Video Intercom Door Station·Quick Start Guide 19 Figure 5-2 Set Password 3. Enter a new password, and confirm the password.The character description for each numeric key is shown in Table 5-2.Table 5-2 Character Description Key Description Key Description 1 1,.?!*#- 6 6mnoMNO 2 2abcABC 7 7pqrsPQRS 3 3defDEF 8 8tuvTUV 4 4ghiGHI 9 9wxyzWXYZ 5 5jklJKL 0 0 When entering the password, taking the numeric key 2 as example, press the numeric key 2 once, the text field shows "2", and press it again, the text field shows "a", and press it again, the text field shows "b", and so on.   STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (Using a minimum of 8 characters, including at least three of the following categories: upper case letters, lower case letters, numbers, and special characters.) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Press the # key to complete the activation.
Video Intercom Door Station·Quick Start Guide 20 5.3 Editing Network Parameters Purpose: Network connection is mandatory for the use of door station. Steps: 1. Go to the configuration mode.1) Hold down the * key and the # key for 2s to enter the admin password interface.2) Enter the admin password, and press the # key.Figure 5-3 Admin Password Interface The default admin password is 888999. 2. Enter the network parameters settings interface.1) Press the numeric keys 4 and 6 to switch to the network configuration interfaceFigure 5-4 Network Configuration Interface 2) Press the # key to enter the network parameters settings interface.
Video Intercom Door Station·Quick Start Guide 21 Figure 5-5 Network Parameters Settings Interface 3. Edit network parameters.1) Move the cursor to parameters to be configured.2) Press the # key to enter or exit the editing mode.4. Press the * key to exit the network configuration interface.5.4 Changing Password Purpose: 2 kinds of password are available when using the door station: configuration password (admin password) and card activation password.   Configuration Password: It is necessary when you want to configure parameters of the door station, such as IP parameters, door station No., system type, and so on.   Card Activation Password: It is necessary when you want to issue cards via password.   The default configuration password is 888999. We recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. Steps: 1. Go to the configuration mode.1) Hold down the * key and the # key for 2s to enter the admin password interface.2) Enter the admin password, and press the # key.
Video Intercom Door Station·Quick Start Guide 22 Figure 5-6 Admin Password Interface The default admin password is 888999. 2. Press the numeric keys 4 and 6 to switch to the password settings interface.Figure 5-7 Password Settings Interface Chaning Configuration Password Steps: 1. On the password settings interface, press the numeric key 1 to enter the configuration password changing interface. Figure 5-8 Configuration Password Changing Interface
Video Intercom Door Station·Quick Start Guide 23 2. Enter the old password, and the new password, and confirm the new one.1) Move the cursor to parameters to be configured.2) Press the # key to enter or exit the editing mode.3. Press the * key to exit the password settings interface.Chaning Card Activation Password Steps: 1. On the password settings interface, press the numeric key 2 to enter the card activation password changing interface. Figure 5-9 Card Activation Password Changing Interface 2. Enter the old password, and the new password, and confirm the new one.3) Move the cursor to parameters to be configured.4) Press the # key to enter or exit the editing mode.3. Press the * key to exit the password settings interface.5.5 Calling Resident You can call residents via the door station no matter the door station is in the network intercom system or the analog intercom system.   The door station can work as main/sub door station, and outer door station, which correspond to different calling resident modes respectively.   Working as Main/Sub Door Station Steps: 1. Enter the Room No..2. Press the # key or the  key to start calling the resident. Working as Outer Door Station Steps:
Video Intercom Door Station·Quick Start Guide 24 1. Enter the Community No. and the # key, the Building No. and the # key, the Unit No.and the # key, and the Room No. and the # key.2. Press the  key to start calling the resident. 5.6 Unlocking Door Before you start: Make sure your door station works as the main/sub door station. Purpose: 2 ways are available to unlock the door: unlocking door via password, and unlocking door via card.   Unlocking Door by Password Unlocking the door by inputting the password is only available in the network intercom system. Steps: 1. Enter the # key and the Room No..2. Enter the password and the # key.The password varies according to different rooms.The default unlocking password is 123456.Unlocking Door by Card Before you start: Make sure the card has been issued. You can issue the card via the door station, or via iVMS-4200 client software. Please refer to User Manual for detail steps.   Unlocking the door by swiping the card is available both in the network intercom system and the analog intercom system. Steps: Swipe the card on the card induction area to unlock the door. The main card does not support unlocking the door.
Video Intercom Door Station·Quick Start Guide 25 6 Remote Operation via Batch Configuration Software 6.1 Activating Device Remotely Purpose: You are required to activate the device first by setting a strong password for it before you can use the device.   Activation via Batch Configuration Tool, and Activation via iVMS-4200 are supported. Here take activation via Batch Configuration Tool as example to introduce the device activation. Please refer to the user manual for the activation via iVMS-4200.   Steps: 1. Run the Batch Configuration Tool.Figure 6-1 Selecting Inactive Device 2. Select an inactivated device and click the Activate button.Figure 6-2 Activation 3. Create a password, and confirm the password.
Video Intercom Door Station·Quick Start Guide 26 STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (Using a minimum of 8 characters, including at least three of the following categories: upper case letters, lower case letters, numbers, and special characters.) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Click the OK button to activate the device.When the device is not activated, the basic operation and remote operation of devicecannot be performed.You can hold the Ctrl or Shift key to select multiple devices in the online devices, and click the Activate button to activate devices in batch.6.2 Editing Network Parameters Purpose: To operate and configure the device via LAN (Local Area Network), you need connect the device in the same subnet with you PC. You can edit network parameters via batch configuration tool, and iVMS-4200 software. Here take editing network parameters via batch configuration tool as example. Steps: 1. Select an online activated device and click the Edit NET Parameters button.Figure 6-3 Clicking Edit NET Parameters Button 2. Change the device IP address and gateway address to the same subnet with yourcomputer.3. Enter the password and click the OK button to activate the network parameters modification.
Video Intercom Door Station·Quick Start Guide 27 Figure 6-4 Editing Network Parameters The default port No. is 8000.After editing the network parameters of device, you should add the devices to the device list again.6.3 Adding Device For batch configuration tool and iVMS-4200 software, you should add device to the software so as to configure the device remotely.   3 ways for adding the device are supported: adding active online devices within your subnet, adding device by IP address, and adding device by IP segment. Here take adding online device and adding device by IP address via batch configuration tool as example. 6.3.1 Adding Online Device Steps: 1. Select an active online device or hold the Ctrl or Shift key to select multiple devices in the online devices list. Figure 6-5 Online Devices Interface 2. Click the  button to pop up the login dialog box.
Video Intercom Door Station·Quick Start Guide 28 Figure 6-6 Login Dialog Box 3. Enter the user name and password.4. Click the OK button to save the settings.Only devices successfully logged in will be added to the device list for configuration.If you add devices in batch, please make sure selected devices have the same username and password.6.3.2 Adding by IP Address Purpose: You can add the device by entering IP address. Steps: 1. Click the  button to pop up the adding devices dialog box. Figure 6-7 Adding Button 2. Select IP Address in the adding mode drop-down list.3. Enter the IP address, and set the port No., user name and password of the device.
Video Intercom Door Station·Quick Start Guide Figure 6-8 Adding by IP Address 4. Click the OK button to add the device to the device list.You cannot add the device(s) to the device list if the user name and password are notidentical.When you add devices by IP Address, IP Segment or Port No., the devices should be online devices.Appendix Installation Notice While  installing  the  indoor  station,  make  sure  that  the  distance  between  any  two devices is far enough to avoid the howling and echo. The distance between two devices is recommended to be longer than 10 meters. Here devices refer to indoor station, outdoor station and master station. 0104401070324 29
Video Intercom Door Station·Quick Start Guide 30 38 Wiring Cables Cable  Specification Power Cord of Door Station  RVV 2*1.0 Network Cable of Door Station  UTP-five Categories Door Lock Wiring (With Door Magnetic)  RVV 4*1.0 Door Lock Wiring (Without Door Magnetic)  RVV 2*1.0 Exit Button Wiring  RVV 2*0.5 External Card Reader Wiring  RVVP 4*0.75
Video Intercom Door Station·Quick Start Guide 40