read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:001 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comType code TNLR-Q80L400-H1147Ident no. 7030204Mounting conditions non-flush, flush mountableAmbient temperature -25…+70 °COperating voltage 19.2…28.8VDCDC rated operational current ð 230 mAData transfer inductive couplingOperating frequency 13.56 MHzRadio communication and protocol standards ISO 15693Read/write distance max. 345 mmOutput function 4-wire, read/writeConstruction rectangular, Q80L400Dimensions 400x 80x 25mmHousing material plastic, PBT, blackMaterial active area plastic, BlackConnection male, M12 x 1Vibration resistance 55 Hz (1 mm)Shock resistance 30 g (11 ms)IP Rating IP67MTTF 121  years acc. to SN 29500 (Ed. 99) 40 °CPower-on indication LED greenDiagnostic display Functional description of yellow range-restrict-ed LED: If the read/write head is suppliedwith voltage, it briefly checks to see whetherits resonance frequency is affected by sur-rounding metal. If this is the case, the reso-nant circuit off-tunes its frequency to reachagain the (optimum) resonance frequency.However, this is only possible within a cer-tain range. If too much metal is in the envi-ronment, the read/write head cannot re-tuneor the surrounding metal takes too much en-ergy from the field and due to the reducedrange the communication between the read/write head and the data carrier is cut off (theorange range-restricted-LED lights up). If theLED is off, this does not mean conversely,that no reduction in range occurs. The lit LEDis rather an indication of too much metal inthe environment and a greatly reduced range(about 50% less).■For roller conveyors■Rectangular, 80 x 400 mm, height 25mm■Active face on top■Plastic, PBT-GF30-V0■Powered and operated only via BL identinterface module■Male M12 x 1, only for use with BL identextension cableConnectors …/S2503Connectors …/S2500Connectors …/S2501Functional principleThe HF read/write heads operating at a fre-quency of 13.56 MHz form a transmissionzone the size of which (0…500 mm) varies,depending on the combination of read/writehead and data carrier.The read/write distances mentioned here on-ly represent standard values measured underlaboratory conditions.The read/write distances of the data carriersfor mounting in metal TW-R**-M(MF) were de-termined in metal.Attainable distances may vary by up to 30 %due to component tolerances, mounting con-ditions, ambient conditions and material quali-ties (especially when mounted in metal)Testing of the application under real operat-ing conditions is therefore essential, especial-ly with read/write on-the-fly!
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:002 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comPackaged quantity 1Special features For roller conveyors (vertical or horizontal ori-entation)
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:003 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrierDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-R16-B128690050150 95 74 205 240TW-R20-B128690050260 102 86 202 240TW-R20-K2690050515 64 70 195 240TW-R30-B128690050390 152 132 217 240TW-R30-K2690050670 122 100 208 240TW-R50-B1286900504150 256 230 242 240TW-R50-K26900507120 216 190 233 240TW-L49-46-F-B128703039074 176 149 197 240
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:004 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrierDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-L80-50-P-B1287030389136 229 204 207 240TW-R80-M-B128703020740 77 56 199 240TW-R80-M-K2703020530 77 64 195 240TW-L86-54-C-B1286900479200 345 306 242 240
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:005 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-R16-B128690050130 95 410 37 240TW-R20-B128690050240 102 404 43 240TW-R20-K2690050530 64 390 35 240TW-R30-B128690050360 152 434 66 240TW-R30-K2690050650 122 416 50 240TW-R50-B1286900504100 256 484 115 240TW-R50-K2690050790 216 466 95 240TW-R50-90-HT-B128154232670 226 484 115 240TW-R50-90-HT-K2154232960 186 466 95 240
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:006 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-I14-B128690052630 95 410 37 240TW-L49-46-F-B128703039068 176 394 74 240TW-L80-50-P-B128703038985 229 414 102 240TW-R80-M-B128703020730 77 398 28 240TW-R80-M-K2703020530 68 390 32 240TW-R4-22-B128703023720 80 368 34 240
read/write headTNLR-Q80L400-H1147Edition • 2015-08-27T10:30:11+02:007 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-L86-54-C-B1286900479120 360 484 153 240
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:001 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comType code TNLR-Q80L400-H1147LIdent no. 7030234Mounting conditions non-flush, flush mountableAmbient temperature -25…+70 °COperating voltage 19.2…28.8VDCDC rated operational current ð 230 mAData transfer inductive couplingOperating frequency 13.56 MHzRadio communication and protocol standards ISO 15693Read/write distance max. 345 mmOutput function 4-wire, read/writeConstruction rectangular, Q80L400Dimensions 400x 80x 25mmHousing material plastic, PBT, blackMaterial active area plastic, BlackConnection male, M12 x 1Vibration resistance 55 Hz (1 mm)Shock resistance 30 g (11 ms)IP Rating IP67MTTF 121  years acc. to SN 29500 (Ed. 99) 40 °CPower-on indication LED greenDiagnostic display Functional description of yellow range-restrict-ed LED: If the read/write head is suppliedwith voltage, it briefly checks to see whetherits resonance frequency is affected by sur-rounding metal. If this is the case, the reso-nant circuit off-tunes its frequency to reachagain the (optimum) resonance frequency.However, this is only possible within a cer-tain range. If too much metal is in the envi-ronment, the read/write head cannot re-tuneor the surrounding metal takes too much en-ergy from the field and due to the reducedrange the communication between the read/write head and the data carrier is cut off (theorange range-restricted-LED lights up). If theLED is off, this does not mean conversely,that no reduction in range occurs. The lit LEDis rather an indication of too much metal inthe environment and a greatly reduced range(about 50% less).■For roller conveyors■The approach direction of the data car-rier can be both, diagonal as well aslongitudinal to the read/write head.■Rectangular, 80 x 400 mm, height 25mm■Active face on top■Plastic, PBT-GF30-VO■Powered and operated only via BL identinterface module■Male M12 x 1, only for use with BL identextension cableConnectors …/S2503Connectors …/S2500Connectors …/S2501Functional principleThe HF read/write heads operating at a fre-quency of 13.56 MHz form a transmissionzone the size of which (0…500 mm) varies,depending on the combination of read/writehead and data carrier.The read/write distances mentioned here on-ly represent standard values measured underlaboratory conditions.The read/write distances of the data carriersfor mounting in metal TW-R**-M(MF) were de-termined in metal.Attainable distances may vary by up to 30 %due to component tolerances, mounting con-ditions, ambient conditions and material quali-ties (especially when mounted in metal)Testing of the application under real operat-ing conditions is therefore essential, especial-ly with read/write on-the-fly!
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:002 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comPackaged quantity 1Special features For roller conveyors (vertical or horizontal ori-entation)
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:003 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrierDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-R16-B128690050150 95 74 205 240TW-R20-B128690050260 102 86 202 240TW-R20-K2690050515 64 70 195 240TW-R30-B128690050390 152 132 217 240TW-R30-K2690050670 122 100 208 240TW-R50-B1286900504150 256 230 242 240TW-R50-K26900507120 216 190 233 240TW-L49-46-F-B128703039074 176 149 197 240
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:004 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrierDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-L80-50-P-B1287030389136 229 204 207 240TW-R80-M-B128703020740 77 56 199 240TW-R80-M-K2703020530 77 64 195 240TW-L86-54-C-B1286900479200 345 306 242 240
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:005 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-R16-B128690050130 95 410 37 240TW-R20-B128690050240 102 404 43 240TW-R20-K2690050530 64 390 35 240TW-R30-B128690050360 152 434 66 240TW-R30-K2690050650 122 416 50 240TW-R50-B1286900504100 256 484 115 240TW-R50-K2690050790 216 466 95 240TW-R50-90-HT-B128154232670 226 484 115 240TW-R50-90-HT-K2154232960 186 466 95 240
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:006 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-I14-B128690052630 95 410 37 240TW-L49-46-F-B128703039068 176 394 74 240TW-L80-50-P-B128703038985 229 414 102 240TW-R80-M-B128703020730 77 398 28 240TW-R80-M-K2703020530 68 390 32 240TW-R4-22-B128703023720 80 368 34 240
read/write headTNLR-Q80L400-H1147LEdition • 2015-08-27T10:30:20+02:007 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.comData carrier longitudinal approachDimensions Type designation Read-write distance Transfer zone Minimum dis-tance betweentwo read-write headsIdent - no. Recommend-ed (mm)max. [mm] lengthmax. [mm]width offsetmax. [mm][mm]TW-L86-54-C-B1286900479120 360 484 153 240
TypeIdent-No.7030204Qty1TNLR-Q80L400-H11471615HWarning:Hazardous voltage can cause electrical shock and burns.Disconnect power before proceeding with any work on this equipment.Made in GermanyHans Turck GmbH & Co. KG · Witzlebenstraße 7 · 45472 Mülheim/Ruhr · GermanyPhone +49 208 49 52-0 · Fax +49 208 49 52-264 · more@turck.com · www.turck.com24 VDC