Harbor Freight 7 Function Digital Multimeter Product Manual
2015-05-27
: Harbor-Freight Harbor-Freight-7-Function-Digital-Multimeter-Product-Manual-723517 harbor-freight-7-function-digital-multimeter-product-manual-723517 harbor-freight pdf
Open the PDF directly: View PDF 
.
Page Count: 7

7 FUNCTION DIGITAL MULTIMETER
OPERATING INSTRUCTIONS
Visit our Web site at http://www.harborfreight.com
Copyright© 2011 by Harbor Freight Tools®.  All rights reserved. 
No portion of this manual or any artwork contained herein may be 
reproduced in any shape or form without the express written consent of 
Harbor Freight Tools.
For technical questions and replacement parts, please call 1-800-444-3353
69096
REV 12a

SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 2
Specications
Frequency 45-450 Hz
DC Amps Ranges: 200µA/2000µA/20mA/200mA, 10A
                Accuracy (@200µA-200mA) 1.2%±2D; (@10A) 3%±2D
DC Voltage Ranges: 200mV/2000mV/20/200/1000V
                Accuracy (@200mV) 0.5%±1D;
(@2000mV-200V) 1.0%±1D;
(@1000V) 1.0%±2D
AC Voltage Ranges: 200/750V
                Accuracy (45-450 Hz) 1.2%±10D
Resistance Ranges:  200/2000/20K/200K/2000K Ohm
                Accuracy (@200-200K Ohm) 0.8%±2D;
(@2000K Ohm) 1.0%±2D;
Sampling Rate 2.5 times/Second
Overload Protection Fast-Acting 500mA/250V Fuse
Operating Temperature Range: 32° - 104° F
Display 1/2″ high 3-1/2-digit LCD
Battery One 9 V (included)
Weight .45 lb.
Features 29-1/2″ Test Leads, Transistor (NPN and PNP) Testing Function, 
Battery Testing Function, and Automatic Polarity and Zero Adjust
Save This Manual
You will need the manual for the safety warnings and 
precautions, and operating and maintenance procedures. 
Keep your invoice with this manual.  Write the invoice number 
on the inside of the front cover. Keep the manual and invoice 
in a safe and dry place for future reference.
Safety Warnings and Precautions
WARNING: When using tool, basic safety precautions should always 
be followed to reduce the risk of personal injury and damage  
to equipment. Warnings continued on page 3.
SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 3
Read all instructions before using this tester!
1.  Avoid working alone.  If an accident happens, an assistant can 
bring help.
2.  Keep work area clean.  Cluttered areas invite injuries.
3.  Avoid electrical shock. Use extreme caution when using this tool 
near uninsulated conductors or bus bars.  Prevent body contact with 
grounded surfaces such as pipes, radiators, ranges, and cabinet 
enclosures when testing voltages.
4.  Avoid damaging meter. Use only as specied in this manual.
5.  Observe work area conditions.  Do not test voltages in damp or 
wet locations. Don’t expose to rain. Keep work area well lit.  
6.  Keep children away.  Children must never be allowed in the work 
area.  Do not let them handle machines, tools, or extension cords.
7.  Store idle equipment.  When not in use, tools must be stored in a 
dry location to inhibit rust.  Always lock up tools and keep out of reach 
of children.
8.  Dress properly.  Do not wear loose clothing or jewelry as they can 
be caught in moving parts. Protective, electrically nonconductive 
clothes and nonskid footwear are recommended when working. Wear 
restrictive hair covering to contain long hair.
9.  Use eye protection.  Always wear ANSI approved impact safety 
goggles. 
10.  Do not overreach.  Keep proper footing and balance at all times. 
Do not reach over or across electrical cables or frames.
11.  Maintain tools with care.  Ensure multimeter has a fresh battery. 
Inspect test leads periodically and, if damaged, have them repaired 
by an authorized technician. 
12.  Stay alert.  Watch what you are doing, use common sense. Do not 
operate any tool when you are tired.
13.  Check for damaged parts.  Before using any tool, any part that 
appears damaged should be carefully checked to determine that it 
will operate properly and perform its intended function. Check for any 
broken parts and any other condition that may affect proper operation. 
Any part that is damaged should be properly repaired or replaced 
by a qualied technician. Do not use the tool if any switch does not 
operate properly.
SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 4
Unpacking
When unpacking, make sure the following parts are included: Digital 
Multimeter, and black and red Test Leads. If any parts are missing or broken, please 
call Harbor Freight Tools at the number on the cover of this manual.  If any part of 
the machine is missing or broken, please call Harbor Freight Tools at the number 
on the front cover as soon as possible.
15.  Replacement parts and accessories.  When servicing, use only 
identical replacement parts. Use of any other parts will void the 
warranty. Only use accessories intended for use with this tool. 
Approved accessories are available from Harbor Freight Tools.
16.  Do not operate tool if under the inuence of alcohol or drugs.  
Read warning labels on prescriptions to determine if your judgment 
or reexes are impaired while taking drugs. If there is any doubt, do 
not operate the tool.
17.  We recommend that only a licensed electrician work on high-
voltage or other potentially dangerous circuits.
Note:   Performance of this tool may vary depending on condition of internal 
battery. 
Warning:  The warnings, cautions, and instructions discussed 
in this instruction manual cannot cover all possible 
conditions and situations that may occur. It must be 
understood by the operator that common sense and 
caution are factors which cannot be built into this 
product, but must be supplied by the operator.
Warning:  This product contains or produces chemicals, 
including lead, known to the State of California to 
cause cancer and birth defects (or other reproductive 
harm).
  (California Health & Safety Code 25249.5 et seq.)
Operation
WARNING:  ELECTRICAL SHOCK CAN CAUSE DEATH OR 
INJURY.  AVOID TOUCHING EXPOSED CONDUCTORS 
OF ELECTRICITY.
Additional Multimeter Precautions
1.  Do not test voltage on AC circuits higher than 750 volts.
2.  Do not test voltage on DC circuits higher than 1000 volts.
3.  Do not test current on circuits higher than 10 amps.

SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 5
4.  Be careful not 
to apply voltage 
to the Test Leads 
when they are 
connected 
to the COM 
(Bottom) and 
VΩmA  (Center) 
Jacks and the 
Multimeter is in 
an Ohms testing 
setting.  Damage 
can occur to the multimeter 
or the fuse may blow.
5.  Do not switch between 
testing modes with the 
multimeter connected to a 
circuit.
AC Voltage Measurements
Measure AC conductors carrying up to 750 VAC, 45-450 Hz.
1.  Turn the Range Selector Switch to 750 ACV setting.
 Always start with the highest range if the voltage is unknown.
2.  Plug the red lead into the VΩmA (Center) Jack. Plug the black lead into 
the COM (Bottom) Jack. Switch the Multimeter ON.
3.  Carefully touch the exposed conductors with the tips of the probes to measure 
the voltage (not amperes). 
4.  Read measurement. 
  If the voltage is less than 200 volts, set the Range Selector Switch to the 
lower range.
5.  When testing is complete, remove Test Leads and store with multimeter.
DC Voltage Measurements
Measure DC conductors carrying up to 1000 VDC.
1.  Turn the Range Selector Switch to 1000 DCV setting.
2.  Follow the directions above under “AC Voltage Measurements”, only use 
the DC settings instead.
COM Jack Volt/Ohm/
mA Jack
DC AMP 
Selection 
Area
DC Volt 
Selection 
Area
Ohm 
Selection 
Area
Transistor 
Selection 
Area
ON/OFF 
Switch
Control Layout
10A 
Selection 
Area/Jack
AC Volt Selection Area
Transistor 
/hFE Jack
Diode
Selection Area
Battery 
Test 
Selection 
Area

SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 6
DC Current Measurements
Measure DC conductors carrying up to 10 amperes.
1.  Turn the Range Selector Switch to the 10A position.
 Always start with the highest range if the amperage is unknown.
2.  Plug the red lead into the 10A (Top) Jack. Plug the black lead into the COM 
(Bottom) Jack.  Switch the Multimeter ON.
3.  Carefully touch the exposed conductors with the tips of the probes to measure 
the amperage.
Note:  Amperage is always tested in series with the circuit under test.
4.  Read measurement. 
  If the reading is less than .2 AMPs, switch the red lead to the VΩmA (Center) 
Jack and set the Range Selector Switch to the 200 mA setting.
5.  When testing is complete, remove Test Leads and store with multimeter.
Resistance Measurements
Measure circuit resistance up to 2000K Ohms.
WARNING: NEVER measure resistance on a circuit with voltage running  
       through it.
1.  Turn the Range Selector Switch to the 200 mA position.
2.  Plug the red Test Lead into the VΩmA (Center) Jack. Plug the black Test 
Lead into the Com (Bottom) Jack.  Switch the Multimeter ON.
  Short the Test Leads together. The meter should read “0” Ohms. 
3.  Touch the exposed conductors with the tips of the Test Leads.
4.  Read measurement.
  If the reading is “1”, set the Range Selector Switch to the next higher Ohm 
(Ω) position.
Transistor (hFE) Measurements
Test transistors to ensure proper function.
1.  Turn the Range Selector Switch to the hFE position.  
  Switch the Multimeter ON.
2.  Insert the transistor pins into the appropriate hFE jack (NPN or PNP) 
according to the EBC (Emitter, Base, Collector) sequence.
3.  The meter will show the approximate hFE value.
Diode Measurement
Test the voltage drop in diodes.
1.  Turn the Range Selector Switch to the Diode ( ) position.
2.  Plug the red Test Lead into the VΩmA (Center) Jack. Plug the black Test 
Lead into the Com (Bottom) Jack.  Switch the Multimeter ON.
3.  Connect the red probe to the anode of the diode and the black to the cathode.

SKU 69096  For replacement parts, please call 1-800-444-3353.  Page 7
NOTE:  No replacement parts are available for this tool.
Battery/Fuse Replacement
  To replace the battery or fuse:
1.  Remove the Test Leads from the multimeter.
2.  Turn the unit over.
3.  Remove both screws using a cross head screwdriver.
4.  Remove back cover.
5.  Pull battery/fuse out of unit and replace with the same.
  (9V battery or 500mA/250V fast-acting fuse)
6.  Replace cover and retighten screws.
Maintenance
1.  Wipe unit with a slightly damp cloth using a light detergent. Do not use 
solvents or abrasives.
2.  Remove battery if not in use for long periods.
3.  Store unit in a dry location.
4.  Other than the battery and fuse, there are no replaceable parts on this unit. 
Repairs should be done by a qualied technician.
4.  The approximate forward voltage drop of the diode will be displayed in 
mV.  If the connection is reversed only “1” will be shown.
Battery Charge Measurement
Test the amount of charge left in batteries.
NOTE: This setting is for testing the charge of small 9V or 1.5V batteries 
only.  Never use this setting to test automotive or lead-acid batteries.  
The high current could cause damage to the meter and/or cause severe 
personal injury.  Use the appropriate DC Voltage setting to test the open 
current voltage of such batteries instead.
1.  Turn the Range Selector Switch to the Battery ( ) position.
2.  Plug the red Test Lead into the VΩmA (Center) Jack. Plug the black Test 
Lead into the Com (Bottom) Jack.  Switch the Multimeter ON.
3.  Connect the red probe to the positive terminal of the battery and the black 
to the negative terminal.
4.  The battery amperage under a load of 370 mΩ will be displayed to a 
resolution of .1mA.
5.  Normal amperage:  For a standard 9V (6LR61) battery  = 25 mA
    For a 1.5 V “AA” (LR6) battery  =   4 mA