Harbor Freight A C R134A Manifold Gauge Set Quick Start Manual

2015-05-27

: Harbor-Freight Harbor-Freight-A-C-R134A-Manifold-Gauge-Set-Quick-Start-Manual-723638 harbor-freight-a-c-r134a-manifold-gauge-set-quick-start-manual-723638 harbor-freight pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadHarbor-Freight Harbor-Freight-A-C-R134A-Manifold-Gauge-Set-Quick-Start-Manual-  Harbor-freight-a-c-r134a-manifold-gauge-set-quick-start-manual
Open PDF In BrowserView PDF
Blue LP (Low-Pressure) side

A/C MANIFOLD
GAUGE SET
QUICK
REFERENCE
GUIDE
ITEM 92649

LP
Manifold
Valve

LP Coupler
Valve

Red HP (High-Pressure) side

LP and
Vacuum
Gauge

HP
Gauge
Sight
Glass

Manifold Valve
operation:
HP
Manifold
Valve

CCW

= close

(clockwise)

= open

(counterclockwise)

Coupler Valve
operation:

Secondary
Charging
Port

LP Coupler

CW

HP Coupler
Valve

Charging Hose

HP Coupler

CCW

= close

CW

= open

(counterclockwise)

(clockwise)

WARNING
To prevent SERIOUS INJURY and DEATH:
1.	READ ENTIRE MANUAL BEFORE USE.
2.	Use in well-ventilated area only.
3.	Wear ANSI-approved safety goggles and
heavy-duty work gloves during setup and use.
4.	DO NOT OPEN either Manifold Valve unless
directed to do so; otherwise, refrigerant leaks,
A/C contamination, and hazardous expulsion
of pressurized refrigerant may occur.

5.	Keep gauge and hoses away
from moving engine parts.
6.	Turn off vehicle’s engine and A/C system
before attaching gauge.
7.	Technicians performing this procedure or
opening refrigeration circuit in automotive
air conditioning systems MUST be certified
in refrigerant recovery and recycling
procedures in compliance with section 609
of Clean Air Act Amendments of 1990.

WARNING

Diagnostic Check

A/C service can be dangerous.
To prevent SERIOUS INJURY,
read entire manual before use.

3

ATTACH COUPLERS:

Attach Couplers to
A/C system,
Blue to
suction LP port,
and Red to
discharge HP port.

1

4

CHECK:

1
KEEP
CLOSED

4

CW

CCW

2

3

2

Connect Red, Blue and Yellow Hoses
to Manifold and Couplers as shown,
RED – RED and BLUE – BLUE.

AFTER:

1

CW

Close Coupler Valves by
turning CCW.
Shut off engine and A/C
system if dynamic check
was done.
CAREFULLY
disconnect Couplers
from A/C system;
hoses may contain
residual refrigerant.

CW

KEEP
CLOSED

4

2

2

CW

1

1

CCW

3

To suction
LP port

CONNECT HOSES:

5

To do a dynamic check, turn on engine,
allow to warm up, then turn on A/C.
Open Coupler Valves - turn CW.
Compare Gauge readings to vehicle’s
service specifications.

To discharge
HP port

CLOSE ALL VALVES:

Manifold Valves - turn CW.
Coupler Valves - turn CCW.

4

WARNING

Recovery / Evacuation

RECOVERY / EVACUATION:

3

ATTACH COUPLERS:

Attach Couplers to
A/C system,
Blue to
suction LP port
and Red to
discharge HP port.

Turn on recovery system / vacuum pump.
Open Coupler Valves - turn CW.
Open Manifold Valves - turn CCW.
Read amount of vacuum on Blue LP Gauge.

1

4

4

CCW

CCW

CW

1

4

CW

CCW

2

3

5

AFTER:

Shut off recovery
system / vacuum
pump when vacuum
reaches manufacturer’s
recommendation.
Close Coupler Valves by
turning CCW.
Disconnect Couplers from
A/C system.

1

CW

2

To suction
LP port

CONNECT HOSES:

A/C service can be dangerous.
To prevent SERIOUS INJURY,
read entire manual before use.

Connect Red and Blue Hoses to Manifold
and Couplers as shown,
RED – RED and BLUE – BLUE.
Connect Yellow Hose to
refrigerant recovery system / vacuum pump.

4

2
2

To refrigerant
recovery system
/ vacuum pump

1

CW

1

CCW

3

To discharge
HP port

CLOSE ALL VALVES:

Manifold Valves - turn CW.
Coupler Valves - turn CCW.

WARNING

Charging

4

A/C service can be dangerous.
To prevent SERIOUS INJURY,
read entire manual before use.

CHARGING:

Turn on engine, allow to warm up,
then turn on A/C.
Open Coupler Valves - turn CW.
Only open BLUE Manifold Valve - turn CCW.

3

ATTACH COUPLERS:

Attach Couplers to
A/C system,
Blue to
suction LP port
and Red to
discharge HP port.

1

1

4

CCW

CW

2

2

KEEP
CLOSED

CW

1

4

CW

CCW

2

3

To suction
LP port

CONNECT HOSES:

Connect Red and Blue Hoses to Manifold
and Couplers as shown,
RED – RED and BLUE – BLUE.
Connect Yellow Hose to R-134a supply.
KEEP R-134A CAN/CYLINDER UPRIGHT.

5

AFTER:

2

To R-134a
supply

1

After charging
manufacturer
recommended amount
of R-134a, close Coupler
Valves by turning CCW.
Shut off engine and
A/C system.
CAREFULLY
disconnect R-134a
supply and Couplers
from A/C system;
hoses may contain
residual refrigerant.

4

CW

1

CCW

3

To discharge
HP port

CLOSE ALL VALVES:

Manifold Valves - turn CW.
Coupler Valves - turn CCW.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00
Instance ID                     : uuid:257f77c1-1a59-2647-8216-755a153264d0
Document ID                     : adobe:docid:indd:59a58670-61dd-11df-8177-977280bed7a8
Original Document ID            : adobe:docid:indd:59a58670-61dd-11df-8177-977280bed7a8
Rendition Class                 : proof:pdf
Derived From Instance ID        : 59a5866d-61dd-11df-8177-977280bed7a8
Derived From Document ID        : adobe:docid:indd:c75c67e4-5fad-11df-baa4-f44afac687b1
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:9C1381480F2068118083F9BBD3047715, xmp.iid:9D1381480F2068118083F9BBD3047715, xmp.iid:9E1381480F2068118083F9BBD3047715, xmp.iid:965AF905132068118083F9BBD3047715, xmp.iid:FE7F1174072068118083DD78B6618C6C, xmp.iid:FF7F1174072068118083DD78B6618C6C, xmp.iid:01801174072068118083B1BD2C1DD5AC, xmp.iid:02801174072068118083B1BD2C1DD5AC, xmp.iid:03801174072068118083B1BD2C1DD5AC, xmp.iid:04801174072068118083B1BD2C1DD5AC, xmp.iid:05801174072068118083B1BD2C1DD5AC, xmp.iid:06801174072068118083B1BD2C1DD5AC, xmp.iid:07801174072068118083B1BD2C1DD5AC, xmp.iid:08801174072068118083B1BD2C1DD5AC, xmp.iid:09801174072068118083B1BD2C1DD5AC
History When                    : 2011:07:27 09:19-07:00, 2011:07:27 09:19-07:00, 2011:07:27 09:22:35-07:00, 2011:07:27 09:23:54-07:00, 2011:08:05 13:46:04-07:00, 2011:08:05 13:46:41-07:00, 2012:10:15 08:20:47-07:00, 2012:10:15 08:26:35-07:00, 2012:10:15 08:28:22-07:00, 2012:10:15 08:29:03-07:00, 2012:10:15 08:45:11-07:00, 2012:10:15 08:50:21-07:00, 2012:10:15 08:50:35-07:00, 2012:10:15 08:51:42-07:00, 2012:10:15 08:56:33-07:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Create Date                     : 2012:10:15 14:33:29-07:00
Modify Date                     : 2012:10:15 14:33:31-07:00
Metadata Date                   : 2012:10:15 14:33:31-07:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Doc Change Count                : 188
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS5 (7.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu