Harbor Freight Automatic Wrist Blood Pressure Monitor Product Manual SMS BP204 P04 R(增加免责声明)
Manual for the 67212 Automatic Wrist Blood Pressure Monitor 67212 Automatic Wrist Blood Pressure Monitor
2015-05-27
: Harbor-Freight Harbor-Freight-Automatic-Wrist-Blood-Pressure-Monitor-Product-Manual-723979 harbor-freight-automatic-wrist-blood-pressure-monitor-product-manual-723979 harbor-freight pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Table of Contents Introduction ......................................................................1 Important Safety Notes ....................................................2 Know Your Unit ................................................................3 Before Taking A Measurement ........................................4 Battery Installation / Replacement ................................5-6 Proper Way of Measurement ......................................7-10 Take a Measurement .................................................11-12 Use the Memory Function .........................................13-14 About Blood Pressure ...............................................15-18 Exceptional Situations ...............................................19-20 Care and Maintenance ..............................................21-22 Specifications ............................................................23-24 Statement ..................................................................25-26 Warranty Information ......................................................27 Before Taking A Measurement 1.Avoid eating,drinking alcohol, smoking, exercising and bathing for 30 minutes before taking a measurement. 2.Stress raises blood pressure.Avoid taking measurements during stressful times. 3.The cuff can be applied to your left or right wrist.Always measure your blood pressure on the same wrist. 4.Measurements should be taken in a quiet place. 5.Position the unit at heart level throughout the measurement. 6.Remain still and do not talk during the measurement. 7.Keep a record of your blood pressure and pulse readings for your physician.A single measurement does not provide an accurate indication of your true blood pressure.You need to take and record several readings over a period of time.Try to measure your blood pressure at the same time each day for consistency. 8.Wait 30~60 seconds between measurements.The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement.You may need to increase the wait time depending on your individual physiological characteristics. 4 5 6 7 8 9 10 11 12 13 About Blood Pressure Blood Circulation The blood circulation is responsible for supplying the body with oxygen. blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle. Systolic Blood Pressure Diastolic Blood Pressure Contraction of the heart muscle Relaxation of the heart muscle Extrude blood Blood return heart Pressure increased to the blood vessel Pressure decreased to the blood vessel Higher pressure Lower pressure 14 15 About Blood Pressure About Blood Pressure Classification of Blood Pressure The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take regular measurements to help you identify an average blood pressure. After each measurement is completed, the LCD display will show your position automatically on the six segments of the bar indicator which corresponds to World Health Organization (WHO) Blood Pressure Indicator. Reference Material: Journal of Hypertension 1999, Vol 17 No.2 Diastolic Blood Pressur (mmHg) Severe hypertension 110 WHO Moderate hypertension 100 Red Mild hypertension 90 85 80 Normal systolic value Yellow Green Normal blood pressure Optimal blood pressure (target value) *Note! 120 130 140 160 180 Systolic Blood Pressure (mmHg) When a person’s systolic and diastolic pressures fall into different categories, the higher category should apply. 16 17 About Blood Pressure Classification of Blood Pressure Exceptional Situations Error Indicators The following symbol will appear on the display when measuring abnormal. Symbol High blood pressure can go unnoticed for a long time, since it doesn’t cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure: Overweight; High cholesterol level; Smoking; Excessive alcohol consumption; Stress and emotional upset; Excessive consumption of salt; Lack of physical exercise; Genetic / hereditary predisposition; Underlying illnesses, such as kidney disorders or endocrine disturbance. If your blood pressure reaches upper values of 140~160 mmHg and lower values of 90~95 mmHg in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways: Loose weight and lower your cholesterol level; Reduce the consumption of alcohol; Reduce the intake of salt; Stop smoking; Take regular exercise; Monitor your blood pressure. Cause Correction Wrap the cuff correctly and tightly. The course of inflating appears error. Inflate over again after ensuring. When measurement fails. Exceptional Situations Eliminate Fault Problem Causes and Solutions No power. Replace all the worn batteries with two new ones. No display appears on the display screen. Check the battery installation for proper placement of the batteries polarities. Measurement values appear too high or too low. Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the cuff, may affect your blood pressure. Review the sections "Proper Way of Measurement" and "Take a Measurement". 20 Measure over again according to correct way. Replace all of the worn batteries with two new ones. When the batteries power are too low. 19 18 Do not move your arm and body, and keep quiet. 21 Specifications Model No. JB5538 Measuring Principle Oscillometric Method Measurement Range of System Pressure 0 to 299 mmHg (0 ~ 39.9 kPa) Pulse 40 to 180 Pulses/min Accuracy Pressure 3 mmHg (0.4 kPa) Pulse 5% of reading Inflation Automatic by Internal Pump Exhaust Automatic exhaust valve Display Liquid crystal Digital Display Unit Dimension 62×61×28mm (L×W×H) Unit Weight Approx. 100g (Batteries not included) 23 22 Specifications Memory Stores up to 60 measurements Wrist circumference approx. Cuff Size 5.3 ~ 8.5 inch (13.5 ~ 21.5 cm) Temperature Operating Environment 50 to 104 F (10 ~ 40 ℃ ) Relative Humidity 15 to 90%RH(Noncondensing) Barometric Pressure 105 to 80 kPa Temperature - 4 to 140 F(-20 ~ +60℃) Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers. The algorithm of blood pressure measurement of BP201 is adopted for this device. Storage Environment Relative Humidity 10 to 95%RH(Noncondensing) Battery Type 2 AAA Alkaline Batteries; d.c.3V (Not Included) Battery Life About 6 months when used once a day Accessories Instruction manual,carrying case 24 25 Warranty Information The device might not meet its performance specification if stored or used outside the specificed temperature and humidity ranges. Operating environment: temperature: 10 ~ 40°C (50 ~ 104°F); Humidity: 15 ~ 90%RH (Noncondensing) Storage environment: temperature: -20 ~ 60°C (-4 ~ 140°F); Humidity: 10 ~ 95%RH (Noncondensing) Prolonged overinflation of the bladder may result in temporary uncomfortableness of wrist. Medical Disclaimer This device and manual is not meant to be a substitute for advice provided by doctors or other medical professionals. If you have or suspect that you have a medical problem, promptly consult your physician. 26 The unit is guaranteed to be free of defects in workmanship and materials under normal use for a period of One Year from the date listed on the purchase record. For repair under this warranty. Our authorized service agent must be advised of the fault within the period of the warranty. This warranty covers parts and labor only under normal operations. A transportation fee or freight fee that may be incurred will be the owner's responsibility. Any defect resulting from natural causes, e.g., flood, hurricane etc., is not within this guarantee. This guaranty does not cover damage incurred by: use of the unit not in accordance with the instructions, accidental damage, or being tampered with or serviced by unauthorized service agents. Monitor subjected to misuse, abuse, and neglect of these manual content, non-instructional purposes; unauthorized repair or modifications will be excluded from this warranty. This guarantee specifically excludes expendables and consumables, for example batteries. All warranty claims must be directed to the distributor responsible for the sale of the device. The content of this warranty is subject to change without further notice. Periodical check: Sensitive measuring devices must be checked from time to time for accuracy and leakage, we therefore recommend that the performance should be checked every 2 years. Check and maintenance and repair for the unit,please contact the local distributor for details. 27
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1.1-111 Modify Date : 2013:08:29 17:05:25+08:00 Create Date : 2012:04:20 14:12:27+08:00 Metadata Date : 2013:08:29 17:05:25+08:00 Creator Tool : Adobe Illustrator CS2 Thumbnail Width : 256 Thumbnail Height : 216 Thumbnail Format : JPEG Thumbnail Image : (Binary data 23417 bytes, use -b option to extract) Format : application/pdf Document ID : uuid:7283155a-46c9-4f2d-a427-b1e8d6f09a53 Instance ID : uuid:78bbb563-650b-4bfa-b2a9-48bacd8c55ec Has XFA : No Page Count : 8 Creator : Adobe Illustrator(R) 12.0 For : User, - Title : SMS-BP204-P04-R(增加免责声明).pdf Bounding Box : 0 0 511 426 Container Version : 9 Creator Version : 12 Image Height : 426 Image Width : 511 Image Size : 511x426 Megapixels : 0.218EXIF Metadata provided by EXIF.tools