Harbor Freight Automatic Wrist Blood Pressure Monitor Product Manual SMS BP204 P04 R(增加免责声明)

Manual for the 67212 Automatic Wrist Blood Pressure Monitor 67212 Automatic Wrist Blood Pressure Monitor

2015-05-27

: Harbor-Freight Harbor-Freight-Automatic-Wrist-Blood-Pressure-Monitor-Product-Manual-723979 harbor-freight-automatic-wrist-blood-pressure-monitor-product-manual-723979 harbor-freight pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadHarbor-Freight Harbor-Freight-Automatic-Wrist-Blood-Pressure-Monitor-Product-Manual- SMS-BP204-P04-R(增加免责声明)  Harbor-freight-automatic-wrist-blood-pressure-monitor-product-manual
Open PDF In BrowserView PDF
Table of Contents
Introduction ......................................................................1
Important Safety Notes ....................................................2
Know Your Unit ................................................................3
Before Taking A Measurement ........................................4
Battery Installation / Replacement ................................5-6
Proper Way of Measurement ......................................7-10
Take a Measurement .................................................11-12
Use the Memory Function .........................................13-14
About Blood Pressure ...............................................15-18
Exceptional Situations ...............................................19-20
Care and Maintenance ..............................................21-22
Specifications ............................................................23-24
Statement ..................................................................25-26
Warranty Information ......................................................27

Before Taking A Measurement
1.Avoid eating,drinking alcohol, smoking, exercising and bathing for
30 minutes before taking a measurement.
2.Stress raises blood pressure.Avoid taking measurements during
stressful times.
3.The cuff can be applied to your left or right wrist.Always measure
your blood pressure on the same wrist.
4.Measurements should be taken in a quiet place.
5.Position the unit at heart level throughout the measurement.
6.Remain still and do not talk during the measurement.
7.Keep a record of your blood pressure and pulse readings for your
physician.A single measurement does not provide an accurate
indication of your true blood pressure.You need to take and record
several readings over a period of time.Try to measure your blood
pressure at the same time each day for consistency.
8.Wait 30~60 seconds between measurements.The wait time allows
the arteries to return to the condition prior to taking the blood
pressure measurement.You may need to increase the wait time
depending on your individual physiological characteristics.

4

5

6

7

8

9

10

11

12

13

About Blood Pressure
Blood Circulation
The blood circulation is responsible for supplying the body with oxygen.
blood pressure is the pressure exerted on the arteries.
The systolic blood pressure value (higher pressure or top value) represents
the blood pressure produced by contraction of the heart muscle.
The diastolic blood pressure value (lower pressure or lower value) represents
the blood pressure produced by relaxation of the heart muscle.

Systolic Blood Pressure

Diastolic Blood Pressure

Contraction of
the heart muscle

Relaxation of the
heart muscle

Extrude blood

Blood return heart

Pressure increased
to the blood vessel

Pressure decreased
to the blood vessel

Higher pressure

Lower pressure

14

15

About Blood Pressure

About Blood Pressure
Classification of Blood Pressure

The incidence of hypertension increases with age. In addition, a lack of exercise,
excess body fat and high levels of cholesterol (LDL), which sticks to the inside in
blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial
sclerosis which can lead to very serious conditions such as stroke and myocardial
infarction. For these reasons it is very important to know whether the blood
pressure is within a healthy range. Blood pressure fluctuates from minute to minute,
throughout the day. Therefore it is essential to take regular measurements to help
you identify an average blood pressure.

After each measurement is completed, the LCD display will show your position
automatically on the six segments of the bar indicator which corresponds to World
Health Organization (WHO) Blood Pressure Indicator.
Reference Material: Journal of Hypertension 1999, Vol 17 No.2
Diastolic Blood Pressur (mmHg)

Severe hypertension
110

WHO

Moderate hypertension
100

Red

Mild hypertension
90
85
80

Normal systolic value

Yellow
Green

Normal blood pressure
Optimal
blood pressure
(target value)

*Note!

120

130

140

160

180

Systolic Blood Pressure (mmHg)

When a person’s systolic and diastolic pressures fall into different categories, the
higher category should apply.

16

17

About Blood Pressure
Classification of Blood Pressure

Exceptional Situations
Error Indicators
The following symbol will appear on the display when measuring abnormal.
Symbol

High blood pressure can go unnoticed
for a long time, since it doesn’t cause
noticeable symptoms. The following
are all possible causes of abnormally
high blood pressure:
Overweight;
High cholesterol level;
Smoking;
Excessive alcohol consumption;
Stress and emotional upset;
Excessive consumption of salt;
Lack of physical exercise;
Genetic / hereditary predisposition;
Underlying illnesses, such as kidney
disorders or endocrine disturbance.

If your blood pressure reaches upper
values of 140~160 mmHg and lower
values of 90~95 mmHg in repeated
measurements over several days, you
should consult your doctor for detailed
medical examination. You can assist
the treatment prescribed by your
doctor in the following ways:
Loose weight and lower your
cholesterol level;
Reduce the consumption of alcohol;
Reduce the intake of salt;
Stop smoking;
Take regular exercise;
Monitor your blood pressure.

Cause

Correction
Wrap the cuff correctly and tightly.

The course of
inflating appears
error.

Inflate over again after ensuring.

When measurement
fails.

Exceptional Situations
Eliminate Fault
Problem

Causes and Solutions

No power.

Replace all the worn batteries with two
new ones.

No display appears on the
display screen.

Check the battery installation for proper
placement of the batteries polarities.

Measurement values
appear too high or too low.

Blood pressure varies constantly. Many
factors including stress, time of day, how
you wrap the cuff, may affect your blood
pressure. Review the sections "Proper
Way of Measurement" and "Take a
Measurement".

20

Measure over again according to
correct way.

Replace all of the worn batteries
with two new ones.

When the batteries
power are too low.

19

18

Do not move your arm and body,
and keep quiet.

21

Specifications
Model No.

JB5538

Measuring Principle

Oscillometric Method

Measurement Range
of System

Pressure

0 to 299 mmHg (0 ~ 39.9 kPa)

Pulse

40 to 180 Pulses/min

Accuracy

Pressure

3 mmHg (0.4 kPa)

Pulse

5% of reading

Inflation

Automatic by Internal Pump

Exhaust

Automatic exhaust valve

Display

Liquid crystal Digital Display

Unit Dimension

62×61×28mm (L×W×H)

Unit Weight

Approx. 100g (Batteries not included)
23

22

Specifications
Memory

Stores up to 60 measurements
Wrist circumference approx.

Cuff Size
5.3 ~ 8.5 inch (13.5 ~ 21.5 cm)

Temperature
Operating Environment

50 to 104 F (10 ~ 40 ℃ )

Relative Humidity 15 to 90%RH(Noncondensing)
Barometric Pressure 105 to 80 kPa

Temperature

- 4 to 140 F(-20 ~ +60℃)

Blood pressure measurements determined with this device are equivalent to
those obtained by a trained observer using the cuff/stethoscope auscultatory
method, within the limits prescribed by the American National Standard,
Manual, electronic, or automated sphygmomanometers.
The algorithm of blood pressure measurement of BP201 is adopted for this device.

Storage Environment
Relative Humidity

10 to 95%RH(Noncondensing)

Battery Type

2 AAA Alkaline Batteries; d.c.3V (Not Included)

Battery Life

About 6 months when used once a day

Accessories

Instruction manual,carrying case
24

25

Warranty Information
The device might not meet its performance specification if stored or used
outside the specificed temperature and humidity ranges.
Operating environment: temperature: 10 ~ 40°C (50 ~ 104°F);
Humidity: 15 ~ 90%RH (Noncondensing)
Storage environment: temperature: -20 ~ 60°C (-4 ~ 140°F);
Humidity: 10 ~ 95%RH (Noncondensing)
Prolonged overinflation of the bladder may result in temporary
uncomfortableness of wrist.
Medical Disclaimer
This device and manual is not meant to be a substitute for advice provided by
doctors or other medical professionals. If you have or suspect that you have a
medical problem, promptly consult your physician.

26

The unit is guaranteed to be free of defects in workmanship and materials under
normal use for a period of One Year from the date listed on the purchase record.
For repair under this warranty. Our authorized service agent must be advised of
the fault within the period of the warranty. This warranty covers parts and labor
only under normal operations. A transportation fee or freight fee that may be
incurred will be the owner's responsibility. Any defect resulting from natural
causes, e.g., flood, hurricane etc., is not within this guarantee. This guaranty
does not cover damage incurred by: use of the unit not in accordance with the
instructions, accidental damage, or being tampered with or serviced by
unauthorized service agents.
Monitor subjected to misuse, abuse, and neglect of these manual content,
non-instructional purposes; unauthorized repair or modifications will be
excluded from this warranty. This guarantee specifically excludes expendables
and consumables, for example batteries. All warranty claims must be directed to
the distributor responsible for the sale of the device. The content of this
warranty is subject to change without further notice.
Periodical check:
Sensitive measuring devices must be checked from time to time for accuracy
and leakage, we therefore recommend that the performance should be checked
every 2 years.
Check and maintenance and repair for the unit,please contact the
local distributor for details.

27



Source Exif Data:
File Type                       : AI
File Type Extension             : ai
MIME Type                       : application/vnd.adobe.illustrator
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1.1-111
Modify Date                     : 2013:08:29 17:05:25+08:00
Create Date                     : 2012:04:20 14:12:27+08:00
Metadata Date                   : 2013:08:29 17:05:25+08:00
Creator Tool                    : Adobe Illustrator CS2
Thumbnail Width                 : 256
Thumbnail Height                : 216
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 23417 bytes, use -b option to extract)
Format                          : application/pdf
Document ID                     : uuid:7283155a-46c9-4f2d-a427-b1e8d6f09a53
Instance ID                     : uuid:78bbb563-650b-4bfa-b2a9-48bacd8c55ec
Has XFA                         : No
Page Count                      : 8
Creator                         : Adobe Illustrator(R) 12.0
For                             : User, -
Title                           : SMS-BP204-P04-R(增加免责声明).pdf
Bounding Box                    : 0 0 511 426
Container Version               : 9
Creator Version                 : 12
Image Height                    : 426
Image Width                     : 511
Image Size                      : 511x426
Megapixels                      : 0.218
EXIF Metadata provided by EXIF.tools

Navigation menu