Hayward Pools Abg1001 Users Manual Installation, Operation & Service Procedures Above Ground Pool Heater

2015-02-09

: Hayward-Pools Hayward-Pools-Abg1001-Users-Manual-564630 hayward-pools-abg1001-users-manual-564630 hayward-pools pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadHayward-Pools Hayward-Pools-Abg1001-Users-Manual- Hayward - Installation, Operation & Service Procedures Above Ground Pool Heater  Hayward-pools-abg1001-users-manual
Open PDF In BrowserView PDF
Hayward0205English

8/3/05

9:38 AM

Page 1

HAYWARD

®

Installation, Operation & Service Procedures
Above Ground Pool Heater
Models H100ID1 & ABG1001
Unit must be installed outdoors only
and below an altitude of 2000 feet
FOR YOUR SAFETY
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage,
personal injury, or death.
– Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS
•
•
•
•

Do not try to light any appliance
Do not touch any electrical switch; do not
use any phone in your building
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.

– Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.

PATENT US6082993

1302507301 0607

Hayward0205English

8/3/05

9:38 AM

Page 2

Section I. General Information
Important notice:
The instructions herein are intended for the use of a
qualified technician, specifically trained and experienced in
the installation of this type of heating equipment. Some
states or provinces require that installation and service personnel performing the installation be licensed. If this is the
case in the state or province where heater is located, the
contractor must be properly licensed.
WARNING: Failure to comply with the appliance
installation instructions and service instructions in this
manual may result in equipment damage, fire, asphyxiation, or carbon monoxide poisoning. Exposure to products of incomplete combustion (carbon monoxide) can
cause cancer and birth defects or other reproductive
harm.

Conformance with codes:
The heater shall be installed in accordance with all local
and state codes. The heater installation must conform to the
National Fuel Gas Code ANSI Z223.1 and with the requirements of the authority having jurisdiction. Design
Certification in the United States is in compliance with ANSI
Z21.56 (latest edition).
For Canadian installations, the heater is to be installed in
accordance with standards CAN/CGA B149.1 and B149.2 –
INSTALLATION CODES FOR GAS BURNING APPLIANCES AND EQUIPMENT and/or local codes, and if applicable, Standard CSA C22.1 – CANADIAN ELECTRICAL
CODE, Part 1.

tion) and applicable local codes. If propane gas tank is
installed underground, the discharge of the regulator vent
must be above the highest probable water level.
Propane tanks must have sufficient capacity to provide
adequate vaporization for the full capacity of the equipment
at the lowest expected temperatures. Consult a propane
company expert for correct sizing.

Water piping:
This heater is designed for use with pool and spa/hot
tub water only, as furnished by municipal water distribution
systems. The warranty does not cover heater use with mineral water, sea, salt, or other non-potable waters.
Do not install any restriction in the water pipe between a
heater outlet and the pool/spa with the exception of a threeway switching valve and associated check valve. Blockage
of water flow from heater return to pool may result in fire or
explosion causing property damage, personal injury, or loss
of life.

Plumbing connections:
Water flow rate to the pool must be between 20 and 70
gpm. If flow rate exceeds 70 gpm an external by-pass valve
must be installed. Figure 2 shows a typical heater installation.

Location of heater:
Locate the heater in an area where a leaking heat
exchanger or connection leak will not result in damage to
the area adjacent to the heater or to the structure.
This heater must be installed at least five feet from
the wall of an above-ground pool.
The heater shall not be installed with the top of the vent
assembly within 10 feet below or to either side of any opening into the building.

Outdoor installation only:
The following installation and service clearances must be
maintained from surfaces to provide adequate air flow to the
heater.
Outdoor Installations
Top - Unobstructed
Right side - 10 inches
Front - 10 inches
Left side - 10 inches
Back - 10 inches
Bottom - Combustible floor
Figure 1

An A.G.A. Certified main gas valve shutoff must be
installed outside of the cabinet and within 6 feet of the
heater. Gas shutoff valve must have an inside diameter
large enough to supply the proper amount of gas volume to
the heater.
NOTE: Do not use flexible appliance connectors on
any gas connections unless the connector is A.G.A.
approved for outdoor Installation, Is marked with the
BTUH capacity (which must be equal to or greater than
100,000 BTUH), and the type of gas (Natural or LP) to be
used.

Propane Gas:
All Propane gas tanks must be located outdoors away
from the pool and in accordance with the standard for storage and handling of propane gas, ANSI/NFPA 58 (latest edi-

2

Electrical system:
This heater is equipped with a standard 3-prong 120 volt
cordset. The plug must be inserted into a GFI protected,
watertight, outdoor receptacle rated for at least 10 amps.
The heater must be electrically grounded and bonded in
accordance with local codes, or in the absence of local
codes, with the National Electrical Code ANSI/AFPA 70.
If the heater must be hard wired, open the junction box
and disconnect the cord. Remove the cord and strain relief
and wire the heater in accordance with local codes or the
National Electrical Code.
The ignition system used to light the burners is a direct
spark system which requires 120 volt AC current as does
the blower motor. The system amp draw is 2 amps.
It is strongly recommended that the heater be supplied
with a constant power source. If remote operation is
required, the heater should be controlled through the thermostat only.

Installation above or below water level:
This heater is supplied with a pressure switch factory set at
3.0 psi. If the heater does not operate and the pressure
switch is at fault, the following procedure is recommended to
adjust the switch:

Hayward0205English

8/3/05

9:38 AM

Page 3

1. Clean filter thoroughly.
2. Set heater thermostat to highest setting.
3. Start filter pump. Make sure all air is out of water
lines and complete system is full of water.
4. Place a 5/64” allen head wrench in the adjusting
socket on the front of the switch and turn it

clockwise to increase the pressure required to close
the switch (this may be required if the heater is
installed more than 4 feet below water level).
5. To check operation, turn the pump on and off several
times. The heater should shut off immediately when
the pump is shut off.

Section IV. Installer
Gas line testing:

Gas pressure test procedure:

The appliance and its gas connection shall be leak tested before placing the appliance in operation. The heater
and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1⁄2 psig. The
heater must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressure equal to or less than 1⁄2 psig.
The gas supply line must be capped when not connected. After pressure testing, reconnect the gas piping to the
gas valve. Turn gas supply on and test all pipe and pilot tubing joints for leaks. Use a soap and water solution. Bubbles
forming indicate a leak. Never use a open flame (match,
lighter, torch, etc.) as a leak could cause an explosion
or injury. Shut off gas and fix even the smallest leak immediately. Be sure to leak test the main burner fittings using the
above procedure once the heater is in operation.

The following gas pressure adjustments are important to
proper operation of the heater. Incorrect settings can cause
improper operation.
1. Turn pump, main gas valve and heater power on. Start
heater following lighting instructions.
2. Using a manometer, determine the inlet gas pressure.
The inlet gas pressure must not exceed 10.5" W.C.
(water column pressure) for Natural gas or 13" W.C. for
Propane gas. Exposure to higher pressures can damage the gas control valve, causing leaks or
diaphragm rupture. This damage could result in fire,
explosion or burner overfiring leading to carbon monoxide poisoning. The inlet gas pressure must not be below
3.0" W.C. for Natural gas and for Propane. The heater
may fail to operate at low inlet gas pressures. If the inlet
gas pressure is too high or too low, the installer must
contact the gas supplier and request that the inlet pressure to the heater be adjusted.
3. Using a manometer, determine the gas operating pressure. Manifold pressure for both natural and propane gas
is 2.0" W.C. The gas valve is preset to operate at this
pressure, no adjustment is necessary.
3

Hayward0205English

8/3/05

9:38 AM

Page 4

Gas pipe size:

Figure 4

Follow local (as codes for proper gas line material selection (copper, iron or plastic etc.)
It is VERY IMPORTANT when installing a propane heater on a
two (2) stage regulation system, to follow the gas line sizing
chart below—without exception.
HIGH PRESSURE “TWO STAGE” SYSTEMS:
HIGH PRESSURE PROPANE GAS PIPE SIZING
“FIRST STAGE”: (Based upon gas pressure of 10 psig inlet
pressure at a pressure drop of 1 psi.)

LOW PRESSURE NATURAL GAS PIPE SIZING:
(Based upon gas pressure of 0.5 psig or less and a
pressure drop of 0.5” W.C.)
Distance from Meter
Iron
(Natural Gas)
Pipe
0 to25 feet

1/2”

25 to 100 feet

3/4”

100 to 200 feet
1”
LOW PRESSURE PROPANE GAS PIPE SIZING
“SINGLE STAGE”: (Based upon gas pressure of
11” W.C. inlet pressure and a 0.5” W.C. pressure drop)
Distance from Tank
(propane)
0 to 25feet

Iron
Pipe
3/8”

Tubing

25 to 100 feet

1/2”

3/4”

100 to 200 feet

3/4”

7/8”

Distance from outlet of
1st stage regulator to
inlet of 2nd stage regulator

Iron
Pipe

Tubing

0 to 200 feet

1/2”

1/2”

LOW PRESSURE PROPANE GAS PIPE SIZING “SECOND
STAGE” (Based upon gas pressure of 11 inches W.C. inlet
pressure at a pressure drop of 0.5 inch W.C.)

Distance from outlet of
2nd stage regulator to
inlet of gas valve
0 to 10 feet

5/8”

Iron
Pipe

Tubing

1/2”

1/2”

Section III. Consumer Operation & Maintenance
FOR YOUR SAFETY – READ BEFORE OPERATING
General:
Do not operate the heater without water flowing through it.
Do not use the heater if any part has been under water.
Contact a qualified service technician to inspect the entire
heater and replace any part of the control system or gas
valve that was under water. If heater has been totally submerged in water, replace the entire heater.

Pool/Spa water chemistry:
See also Figure 5. The mineral content of swimming
pool water increases daily due to addition of pool sanitizing
chemicals and natural evaporation. Excess minerals will
deposit on pool walls, in the filtration system, and in the
heat exchanger tubes if the mineral content is too high.
Changing spa water regularly and maintaining correct
chemical balance in pool/spa will keep the pool/spa safe
and sanitary and will protect heater and its warranty coverage. Purchase a good “DPD” water test kit and check the
following chemical levels frequently:
CHLORINE OR BROMINE – Recommended level 1 to 4
ppm. Test before use.
pH – Recommended ideal level 7.4 to 7.6. HIGH readings reduce sanitizer efficiency. LOW readings are corrosive.
TOTAL ALKALINITY – 80 to 120 ppm. Test weekly dur-

ing regular use. LOW readings are corrosive and cause
rapid pH changes when chemicals are added.
CALCIUM HARDNESS – 200 to 400 ppm. Test whenever pool/spa is filled. LOW levels of hardness can be very
corrosive.
Remember, addition of any chemicals can change levels
of chlorine, pH, and total alkalinity.
It is recommended that residential spa water be
changed every 2 to 3 months to prevent water problems.
Public spas may need to have the water changed every
week, or even daily, depending on bather load.

Using chlorinators and chemical feeders:
Follow the instructions provided with any automatic or
manual chlorinator and chemical feeder. If a chlorinator is
used, it must be installed down stream from the heater In
the pool return line. Install a check valve between the heater
outlet and chlorinator to prevent chlorine from siphoning
back into the heater. All chemicals must be introduced and
diluted into the pool or spa water before being circulated
through the heater. Do not place chlorine tablets or bromine
sticks directly into the skimmer. High chemical concentrations may result when the pump is not running. High chemical concentrations cause very rapid corrosion of the
heat exchanger. Such damage is not covered under warranty.

Facts about water chemistry:

HEAT EXCHANGERS
DESTROYED

CORROSION
ZONE
0 1

2 3

4 5

ACID

NEUTRAL

FACTORS which affect pool/spa water and, more importantly, the efficiency and operation of the pool/spa heater.
1. PROPER FlLTRATION
2. PROPER CIRCULATION 3. DISINFECTION AND OXIDATION
4. pH CONTROL AND TOTAL ALKALINITY
5. ALGAE CONTROL
What Is pH? It is the measure of the acidity or alkalinity of water. As shown on this chart, it is a critical measurement.

6 7

SCALING
ZONE
7.4 – 7.6
IDEAL

8

9 10 11 12 13 14

HEAT EXCHANGERS
DESTROYED

ALKALINE

Hayward recommends using a four way test kit to obtain…
1. MIN./MAX. pH (7.2 - 7.8)
2.CHLORINE RESIDUAL (1.0 - 3.0 PPM), BROMINE (2.0 - 4.0 ppm)
3. TOTAL ALKALINITY (80 - 100 PPM) for calcium, lithium and sodium hypochlorite, or (100 - 120 PPM) for sodium dichlor, trichlor, and bromine.
4. CALCIUM HARDNESS (200 - 400 PPM)
Figure 5

4

Hayward0205English

8/3/05

9:38 AM

Page 5

Heater operation:
Full lighting and shutdown instructions are included on the lighting instructions label installed on the front access door inside the
heater cabinet. This heater cannot be operated with the front door
removed.
WARNING: If you smell gas in the appliance area or near
the floor, stop and follow instructions on the front cover of
this manual.
NOTE: Do not use the unit below 40°F temperature. Do not
operate heater while an automatic pool cleaner is in use.
NOTE: This unit will not operate if water flow is insufficient.
Make sure filter is clean.

Warning:
Do not ingest alcohol or drugs during use or prior to using pool.
Ingestion of such intoxicants can cause drowsiness which can lead
to unconsciousness, and subsequently result in drowning.
Do not heat pool water in excess of 102°F. A temperature of 100°F
is considered safe for a healthy adult. Hotter water increases the risk
of hyperthermia. Special caution is suggested for younger children.
Pregnant women beware! Soaking in water above 102°F can
cause fetal damage during the first three months of pregnancy
(resulting in the birth of a brain-damaged or deformed child).
Pregnant women should adhere to the 100°F maximum rule.
Before entering the spa or hot tub, users should check the
water temperature with an accurate thermometer; operating thermostats may err in regulating water temperatures by as much as
four degrees Fahrenheit.
Persons with a medical history of heart disease, circulatory
problems, diabetes, or blood pressure problems should obtain their
physician’s advice before using spas or hot tubs.
Persons taking medications which induce drowsiness, such as
tranquilizers, antihistamines, or anticoagulants, should not use

spas or hot tubs.
If the pool/spa is used for therapy, it should be done with the
advice of a physician. Always stir the water before entering to mix
in any hot surface water that might exceed healthful temperature
limits and cause injury.
Do not tamper with controls, because scalding can result if
safety controls are not in proper order.

Temperature controls:
The heater is turned “ON” and “OFF” and the water temperature is adjusted with the thermostat. Turning the thermostat all the
way counterclockwise will turn the heater “OFF.” Turning the thermostat clockwise will turn the heater “ON” and adjust the temperature higher.
The memory stop provides a manual means of locking the
desired maximum temperature setting of the water. Once the maximum setting has been determined, loosen the screw and rotate
the stop to the desired location and retighten the screw.

Periodic inspection:
1. Periodically check the venting system on the heater. The
venting areas must never be obstructed in any way and minimum
clearances must be observed to prevent restriction of combustion
and ventilation air.
2. Keep the entire pool area clean and free of all debris, combustible materials, gasoline and other flammable vapors and liquids. Remove any leaves or paper from around the heater.
3. Do not store chlorine, other pool chemicals or other corrosives in the vicinity of the heater.

Winterization:
Do not operate heater if the temperature falls below 40°F.
Drain all water out of heater to prevent damage to heat
exchanger during freezing weather.

Section IV. Qualified Technician - Servicing
General:

Direct spark module:

WARNING: Do not attempt to repair any components of
heater. Do not modify heater in any manner. To do so may result
in a malfunction which could result in death, personal injury, or
property damage. Check with consumer to see if any part of
heater has been under water. Replace any part of the control system and any gas control which has been under water. Never use
or attempt to use parts that have been previously used.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

The direct spark ignition module is the master control, processing the operational information from the other controls. When the
thermostat calls for heat, the blower turns on for 10 seconds
before the ignitor begins to spark The ignitor begins sparking at
the same time the main gas valve opens, which causes ignition of
the main burner gas. If ignition does not happen within 10 seconds, the module will try to light for (3) consecutive tries at 30 second intervals. If no ignition is received the control will lock out for 1
hour. To reset the module, the thermostat must be turned to the
“OFF” position and back “ON”.
To replace the module:
1. Turn pump, main gas valve and heater power off.
2. Unplug heater.
3. Disconnect wires from the module.
4. Remove module retaining screws.
5. Replace module.

Burner cleaning:
If required, burners can be cleaned in the following
manner:
1. Turn pump, main gas valve and heater power off.
2. Remove the gas manifold.
3. Remove the burners.
4. Brush burners with a wire brush and check that they are free of
lint. dust and spider webs before each season of use. Burners
with damaged ports must be replaced.

Gas valve replacement:
WARNING: Do not attempt to repair gas valve. If found
defective, replace entire valve. Attempts to repair it will void
warranty.
1. Turn pump, main gas valve and heater power off.
2. Disconnect wires to gas valve.
3. Unscrew gas valve from manifold.
4. Install new valve.
5. Reconnect wires to gas valve.

Combustion blower:
The combustion blower provides the air that mixes with the
gas from the main burners for the combustion process. On initial
start-up, the blower operates for 10 seconds to purge gas out of
the heater. Then, the main gas valve opens, the ignitor sparks for
a maximum of 10 seconds and the heater lights. The blower operates the entire time the gas valve is open.
Combustion blower replacement:
1. Turn pump, main gas valve, thermostat and
heater power “OFF”.
2. Remove screws retaining the main top.
3. Disconnect wires attached to the blower.
4. Remove external vent terminal.
5. Remove duct from blower to vent terminal.
6. Remove screws attaching blower to flue collector.
7. Replace blower.
8. Reverse above procedure for installation.
5

Hayward0205English

8/3/05

9:38 AM

Page 6

Operating Instructions

6

Figure 6

Hayward0205English

8/3/05

9:38 AM

Page 7

Parts List & Illustration

ITEM NO. DESCRIPTION
1.
2.

3.
4.
5.
5.
6.
8.
9.
10.
11.

PART NO.

Jacket, Top
IDX JKT 1100
Combustion Blower (JakelgJakel)
IDX BWR 1930
Combustion Blower (JakelgFasco conversion) IDX BWR 1931
Combustion Blower (FascogFasco)
IDX BWR 1932
Blower Gasket (Jakel only)
IDX BLG 1930
High Limit Kit
IDX HLK 1930
Heat Exchanger Assembly (dual tubes)
IDX HXA 1100
Heat Exchanger Assembly (single tube after 6/99) IDX HXA 1101
Water Pressure Switch
CZX PRS 1105
Interlock Switch
IDX ILS 1930
Control Module
IDX MOD 1930
IDX APS 1930
Air Pressure Switch
IDX CPG 1930
Coupling

ITEM NO. DESCRIPTION
12.
13.
14.
15.
16.
17.
18.
19.
20.
20.
21.
22.
22.

Grommet 11⁄2” Pipe
Front Access Door
Burner Orifice, Natural Gas
Gas Manifold
Gas Valve
Ignitor with cable
Burner
Burner Gasket
Air Orifice Bracket, Natural Gas
Air Orifice Bracket, Propane
Control Panel Assembly
Wire Harness
Wire Harness (after 1/00)

PART NO.
IDX GRM 0001
IDX FAD 1101
IDX ORF 1933
IDX MAN 1100
IDX VAL 1930
IDX IGN 1930
IDX BNR 1930
IDX BRG 1930
IDX AOB 1930
IDX AOB 1931
IDX CPA 1100
IDX WHA 1930
IDX WHA 1931

The change from Jakel combustion blowers to Fasco was made for production starting in 1/07.

7

Hayward0205English

8/3/05

9:38 AM

Page 8

Hayward Pool Heater Certificate of Limited Warranty
Limited heater warranty:
TERMS AND COVERAGE: We warrant our pool heater to be free from
defects in workmanship and materials under normal use and service.
Pursuant to this warranty and subject to the Conditions and Exceptions indicated below:
1. We will replace (cost of freight, installation, cost of fuel, and service
labor at user's expense) with the prevailing comparable model, or, at our
option, repair any pool/spa heater that leaks under normal use and service within one year from the date of original installation for all users.
2. In addition, we will replace (cost of freight, installation, cost of fuel. and
service labor at user's expense) or, at our option, repair any part or parts
of the pool/spa heater which malfunctions under normal use and service
within one year from the date of original installation for all users.
LIMITATION ON IMPLIED WARRANTIES: WE ARE NOT LIABLE FOR
ANY CONSEQUENTIAL DAMAGES FOR BREACH OF ANY WRITTEN OR
IMPLIED WARRANTY OF THIS PRODUCT. Implied warranties, including
the WARRANTY of MERCHANTABILITY and all other implied warranties
that may arise from course of dealing or usage of trade imposed on the sale
of this heater under laws of the state are limited in duration to the term of
one (1) year for all users. There are no warranties which extend beyond the
description on the face hereof. We shall not in any event be held liable for
any special, indirect, or consequential damages.
EXPENSE OF DELIVERY AND INSTALLATION: Each pool heater or
replacement part to be furnished under this warranty shall be furnished at
our nearest distribution center. We shall not pay, nor be responsible for shipping or delivery charges to the place of installation, nor for labor charges or
other costs of removal or installation. Every defective heater or part replaced
under this warranty shall become our property, and as such, must be
returned to our distribution center with transportation charges paid by the
user. Any replacement pool heater furnished under this warranty shall
remain in warranty only for the unexpired portion of this warranty.
CONDITIONS AND EXCEPTIONS: This warranty applies only to the
pool/spa at its original place of installation and only for the original owner. It
does not apply if the pool heater is installed in violation of any applicable
code or ordinance, or is not installed, operated and maintained in accordance with our instructions, or is misused, damaged by accident, weather,
act of God, freezing, water void and/or excess pressure, altered or disconnected. It does not apply with respect to:
1. A heater not equipped with Certified C.S.A. limit controls or equivalent
pressure relief valve.
2. A heater operated with settings in excess of, and/or with fuel not conforming to those shown on rating plate;
3. A heater on which the serial numbers have been altered, defaced, or
removed.
4. Leaks arising from defective installation;
5. Production of noise, odors, or discolored (rusty, etc.) water;
6. Leakage substantially contributed to by sediment, lime precipitate and/or
higher than normal dissolved solids (pH above 7.8) in the tank, copper
tubes, or water ways;
7. Leakage caused substantially contributed to by corrosive elements in the
atmosphere (such as the storage of chlorine or other chemicals);
8. Leakage caused substantially or contributed to by corrosive pool water
in an acid condition (pH below 7.2);
9. Damage caused substantially or contributed to by an external source of
energy;
10. A pool/spa heater is a water containing device. Leakage of water from
this device can be expected at some time due to malfunction or the limi-

tations of the service life of various components. Do not install this product where such leakage can cause damage. MANUFACTURER IS NOT
RESPONSIBLE OR LIABLE FOR ANY COSTS INCURRED BY SUCH
DAMAGE.
IN NO CASE ARE WE TO HELD LIABLE FOR DAMAGE TO SURROUNDING AREA OR PROPERTY CAUSED BY LEAKAGE OR MALFUNCTION.
HOW TO CLAIM UNDER THIS WARRANTY: The original owner, upon discovering the defect, must present the attached completed warranty claim
card with proof of purchase either to the dealer or notify the Company in
writing at either address:
Hayward Pool Products, Inc.
900 Fairmont Avenue
or
Elizabeth, NJ 07207

Hayward Pool Products, Inc.
2875 Pomona Boulevard
Pomona, CA 91768

Upon receipt of such notification we shall decide whether to repair such
parts or replace any pool heater, reserving at all times the right to inspect in
order to verify any claimed defect. We also reserve the right to have our representatives make any inspections, repairs, or to furnish replacements. This
warranty is intended as a legally binding obligation of the Company, enforceable in the courts. This warranty may give you specific legal rights which
may vary from state to state.
LIMITATION ON LIABILITY: All intended representations have been
expressly set forth in this document. This warranty may not be extended
by oral or any other additional representations, written sales information,
drawings, or other malfunction, is strictly limited to repair or replacement of
the defective heater or part. as provided herein and the Company is not
responsible herein for incidental or consequential or incidental costs or
damages. The company neither assumes, nor authorizes any person or
firm to assume for us, any further liability or obligation in connection with
the sale, installation, use, maintenance, or existence of the heater.
SAFETY WARNING: Pool heaters are heat producing appliances and to
avoid damage or injury in the event of possible overheating of the outer
jacket (1) no materials should be stored against the jacket and (2) care
should be taken to avoid unnecessary contact (especially by children) with
the jacket. When lighting a gas heater, the lighting instructions must be followed exactly to prevent "flashback" of excess gas in the heater. Electronic
ignition heaters and electric heaters must have the power shut off when
making adjustments to, servicing, or coming into contact with the heater.
UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS,
SUCH AS GASOLINE OR PAINT THINNERS, BE USED OR STORED IN
THE VICINITY OF THE HEATER OR IN ANY LOCATION FROM WHICH
FUMES COULD REACH THE HEATER. For your comfort, enjoyment and
safety, please read the enclosed operating instructions carefully.

FireTile™ five year limited warranty:
TERMS AND COVERAGE: This warranty is an extended warranty applicable to the FireTile™ components used in the conditions, limitations, and
exceptions of the regular pool heater limited warranty remain in force,
apply to this warranty, and are incorporated herein by reference.
Under the terms of this special FireTile™ limited warranty, we will replace
(cost of freight, installation, cost of fuel, and service labor at user's
expense) any components of your pool/spa heater made of FireTile™
which fail from defects in workmanship and materials under normal use
and service in a single family residential application for a period of five (5)
years.

USE THIS FORM ONLY FOR MAKING A CLAIM

LIMITED 1 YEAR POOL/SPA/HOT TUB HEATER CLAIM FORM
Model No.
Serial No.
Purchasers’s Name
Installation Address
City/State/Zip
Single Family Residential Use c Yes c No If no, fill in use
Dealers Name
Address
Date of installation
Note to Dealer: Fill in the following information on replacement heater.
Model No.
Serial No.
Date installed

HAYWARD POOL PRODUCTS, INC.
Hayward Pool Products, Inc.
900 Fairmount Avenue
Elizabeth, NJ 07207

Hayward Pool Products, Inc.
2875 Pomona Boulevard
Pomona, CA 91768

Hayward Pool Products, Inc.
2880 Plymouth Drive
Oakville, Ontario L6H 5R4

Hayward S.A.
Zoming de Jumet
B6040 Jumet, Belgium

© 2004 Hayward Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
About                           : uuid:dd58c46f-8821-4eef-9a9b-57d89bd2482e
Producer                        : QuarkXPress(tm) 6.1
X Press Private                 : %%DocumentProcessColors:.%%EndComments
Create Date                     : 2005:08:03 09:38:53Z
Creator Tool                    : QuarkXPress(tm) 6.1
Modify Date                     : 2008:03:10 12:09:05-04:00
Metadata Date                   : 2008:03:10 12:09:05-04:00
Document ID                     : uuid:74cd6f56-042c-11da-8f87-000d9345b916
Instance ID                     : uuid:8f37afa2-88a3-48a1-a22a-d1b7eb6bf2b9
Format                          : application/pdf
Title                           : Hayward - Installation, Operation & Service Procedures - Above Ground Pool Heater
Creator                         : Hayward Pool Products
Has XFA                         : No
Page Count                      : 8
Author                          : Hayward Pool Products
EXIF Metadata provided by EXIF.tools

Navigation menu