Heiman Technology HS2SKEUS Smart Metering Plug User Manual

Shenzhen Heiman Technology Co.,Ltd. Smart Metering Plug

User Manual

Smart  Plug Quick Operation GuideMetering Technical ParametersProduct DescriptionProduct DetailsClick add icon in the app to enter into networking mode. 1 2 3 4*Please read the user manual carefully before operation.The guide picture is for reference only, please in kind prevail.Supply HubLED IndicatorPower Switch/Networking ButtonThis  is  a  smart  m plug,  adopts  flame retardant  housing  shell,  and  super  low  power consumption  ZigBee  wireless  transmission technology.  ZigBee,  voltage,  current  overload  protection. ug and play, easy to install.etering power  meteringIt can be used as   wireless repeater,  to  extend  wireless  communication distance.  It  supports    and timing  switch  functions.  With  the  function  of powerPl1.Working Voltage: AC100V~240V (full voltage range)2.Average Power Consumption: <0.5W3.Maximum Load: 3000W4. Metering Voltage Range: 100VAC-240VAC5.Metering Current Range:<16A6.Metering Power Range: <3000W7. Wireless Networking Distance: Up to 100 meters                                                      ( in open area )8. Working Environment: -10℃ ~ +50℃9. Working Humidity:   95%RH10. Networking :   network11. Dimensions: 79.6*67.9*72mm ≤ZigBeePress  and  release  the  power  switch  (networking  button)  to enter into networking state, LED Indicator flash for 3 seconds(5  times  per  second)  if  networking  successfully,  then  APPwill prompt “networking successfully”.1.Enter  into  the  device  list  of  APP,  then  long  press  the device needed to delete, APP interface will prompt “delete device”, click to delete device.2.Long press power switch(networking button) for 5 seconds to  disconnect  network.  LED  Indicator  flash  slowly  for  3 seconds(2  times  per  second),  which  indicates  network disconnecting successfully.Delete sub deviceDescription of LED Indicator StatusGreen LEDFlash for 3 seconds if networking successfully (5 times /second).1.Flash slowly for 3 seconds(2 times per second) if network   disconnecting successfully.2.Long press power switch(networking button) for 5    seconds, green LED flash slowly for 3 seconds(2 times   per second) if network disconnecting successfully.  State Light Light on: Plug turned on   Light off: Plug turned off 6 7 8 9Statement*Instruction is for reference only, please prevail in kind.*Because of the updating of the technology, the final   interpretation right owned by factory, if there are any   inconformities when using this products under this instruction.Please choose proper plug typeaccording to your need.!US Standard Smart Plug Plug the Smart Metering Plug into the p  to enter into Ad-Hoc networking state (networking state will befinisheda minute later), the interface will prompt “networkingsuccessfully”.lug5Networking 2: Manual networkingNetworking 1: Ad-Hoc networkingThe APP  interface  will show the power of the  appliance  and record the power consumption after appliance is plugged into the smart plug.Power  on/off:  After  pressing  p , blue  LED  keeps  on  and  supply  hub  will  be  powered  on; Press power switch/networking  buttonower switch/networking button  again, blue LED turned off,supply hub will be powered off. 10 11UK Standard Smart   PlugChooseable PlugsIt  is  suitable  for  table  lamp, TV, air-conditioner, refrigerator,electric  fan,  coffee  machine,bread machine and some otherhousehold appliances to meterpower consumption.HS2SK-E-USFCC Warning:This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interferenceto radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interferenceby one or more of the following measures:o Reorient or relocate the receiving antenna.o Increase the separation between the equipment and receiver.o Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected.o Consult the dealer or an experienced radio/TV technician for help.Caution: Any changes or modifications to this device not explicitly approved bymanufacturer could void your authority to operate this equipment.This device complies with part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference thatmay cause undesired operation.To comply with FCC RF exposure compliance requirements,this grantis applicable to only mobile configurations. The antennas used for thistransmittermust be installed to provide a separation distance of at least 20 cmfrom allpersons and must not be co-located or operating in conjunction with anyotherantenna or transmitter.

Navigation menu