Hewlett Packard Enterprise AP105SDR Aruba AP-105 Wireless Access Point User Manual IAP105 IG

Aruba Networks, Inc. Aruba AP-105 Wireless Access Point IAP105 IG

Manual

Download: Hewlett Packard Enterprise AP105SDR Aruba AP-105 Wireless Access Point User Manual IAP105 IG
Mirror Download [FCC.gov]Hewlett Packard Enterprise AP105SDR Aruba AP-105 Wireless Access Point User Manual IAP105 IG
Document ID1545870
Application ID6qWuRfNFAC4gHLfZoJfUcQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize66.67kB (833419 bits)
Date Submitted2011-09-21 00:00:00
Date Available2012-03-16 00:00:00
Creation Date2009-07-01 16:54:10
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2011-08-22 17:28:22
Document TitleIAP105_IG.fm
Document CreatorFrameMaker 9.0
Document Author: dmontgomery

IAP-105 Wireless Access Point
Installation Guide
About the Aruba IAP-105 Access Point
Power
Connector



1.25A
Wireless transceiver
Protocol-independent networking functionality
IEEE 802.11a/b/g/n operation as a wireless access point
IEEE 802.11a/b/g/n operation as a wireless air monitor
Compatibility with IEEE 802.3af PoE
ENET
CONSOLE



The Aruba IAP-105 access point provides the following capabilities:
Successful setup of an IAP-105 access point consists of five tasks, which must be
performed in this order:
1. Identify the specific installation location for each IAP.
2. Install each IAP.
Package Contents

3. Verify post-installation connectivity.
IAP-105 access point
Installation guide (this document)
Aruba Instant Quick Start Guide
4. Configure each IAP.
AP105_002

CAT5 UTP cable of required length
One of the following power sources:
 IEEE 802.3af-compliant Power over Ethernet (PoE) source
 The POE source can be any power source equipment (PSE)
 Aruba IAP AC-DC adapter kit (sold separately)
Summary of the Setup Process
CONSOLE

Inform your supplier if there are any incorrect, missing, or damaged parts. If
possible, retain the carton, including the original packing materials. Use
these materials to repack and return the unit to the supplier if needed.
Installing the IAP
Before installing your IAP-105 access point, be sure that you have the following:
ENET
12V
The Aruba IAP-105 wireless access point supports the IEEE 802.11n standard for
high-performance WLAN. This access point uses MIMO (Multiple-in, Multipleout) technology and other high-throughput mode techniques to deliver highperformance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously
supporting existing 802.11a/b/g wireless services.

IAP Pre-Installation Checklist
Figure 3 IAP-105 Rear
Aruba Networks, Inc., in compliance with governmental requirements, has
designed the IAP-105 access points so that only authorized network
administrators can change the settings. For more information about IAP
configuration, refer to the Aruba Instant Quick Start Guide and Aruba
Instant User Guide.
Reset Button
Console Port
Service to all Aruba Networks products should be performed by trained
service personnel only.
Using the Integrated Wall-Mounting Slots
The keyhole-shaped slots on the back of the IAP can be used to attach the device
upright to an indoor wall or shelf. When you choose the mounting location, allow
additional space at the right of the unit for cables.
1. Since the ports are on the back of the device, make sure that you mount the
IAP in such a way that there is a clear path to the Ethernet port, such as a predrilled hole in the mounting surface.
2. At the mounting location, install two screws on the wall or shelf, 1 7/8 inches
(4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends
using appropriate wall anchors (not included).
3. Align the mounting slots on the rear of the IAP over the screws and slide the
unit into place (see Figure 4).
Figure 4 Installing the IAP-105 Access Point on a Wall
Use the console port to connect to a terminal for direct local management.
Ethernet Port
IAP-105 is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing, MDI/
MDX wired-network connectivity port. This port supports IEEE 802.3af Power
over Ethernet (PoE) compliance, accepting 48VDC as a standard defined
Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE
midspan injector, or network infrastructure that supports PoE.
Identifying Specific Installation Locations
If PoE is not available, an optional Aruba IAP AC-DC adapter kit (sold
separately) can be used to power the IAP-105.
AP105_005
Reset Button
The reset button can be used to return the IAP to factory default settings. If you
have converted your IAP to a campus AP, pressing the reset button converts it
back to an IAP. To reset the IAP:
RF Radiation Exposure Statement: This equipment complies with FCC
RF radiation exposure limits. This equipment should be installed and
operated with a minimum distance of 13.78 inches (35 cm) between the
radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter
must not be co-located or operating in conjunction with any other antenna
or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this
device is restricted to indoor use to reduce the potential for harmful
interference with co-channel Mobile Satellite Systems.
IAP-105 Hardware Overview
3. Power-on the IAP without releasing the reset button. The power LED will
flash within 5 seconds.
Figure 2 IAP-105 Front
4. Release the reset button.
The power LED will flash again within 15 seconds indicating that the reset is
completed. The IAP will now continue to boot with the factory default settings.
Before You Begin
105
EU Statement:
Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands.
Please refer to the Aruba Instant User Guide for details on restrictions.
AP105_001
PWR
11B/G/N
ENET
11A/N
LEDs
The IAP-105 is equipped with four LEDs that indicate the status of the various
components of the IAP.




PWR: Indicates whether or not the IAP-105 is powered-on
ENET: Indicates the status of the IAP-105’s Ethernet port
11A/N: Indicates the status of the 802.11a/n radio
11B/G/N: Indicates the status of the 802.11b/g/n radio
For information about the IAP-105’s LED behavior, see Table 1 on page 2.
FCC Statement: Improper termination of access points installed in the
United States (non-US Regulatory Domain model/s) will be in violation of
the FCC grant of equipment authorization. Any such willful or intentional
violation may result in a requirement by the FCC for immediate termination
of operation and may be subject to forfeiture (47 CFR 1.80).
Produit réseau local radio basse puissance operant dans la bande
fréquence 2.4 GHz et 5 GHz. Merci de vous referrer au Aruba Instant User
Guide pour les details des restrictions.
You can mount the IAP-105 access point on a wall or on the ceiling. Each
location should be as close as possible to the center of the intended coverage
area and should be free from obstructions or obvious sources of interference.
These RF absorbers/reflectors/interference sources will impact RF propagation
and should have been accounted for during the planning phase and adjusted for
in VisualRF.
Identifying Known RF Absorbers/Reflectors/Interference
Sources
2. If necessary, connect the console cable to the console port on the back of the
IAP.
Hold the IAP next to the ceiling tile rail with the ceiling tile rail mounting slots at
approximately a 30-degree angle to the ceiling tile rail (see Figure 5). Make sure
that any cable slack is above the ceiling tile.
Figure 5 Orienting the Ceiling Tile Rail Mounting Slots
RF absorbers include:



Cement/concrete—Old concrete has high levels of water dissipation, which
dries out the concrete, allowing for potential RF propagation. New concrete
has high levels of water concentration within the concrete, blocking RF
signals.
Natural Items—Fish tanks, water fountains, ponds, and trees
Brick
RF reflectors include:

Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/
heating ducts, mesh windows, blinds, chain link fences (depending on
aperture size), refrigerators, racks, shelves, and filing cabinets
Do not place an IAP between two air conditioning/heating ducts. Make sure
that APs are placed below ducts to avoid RF disturbances.
RF interference sources include:

Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare
riferimento alla Aruba Instant User Guide per avere informazioni detagliate
sulle restrizioni.
Make sure the IAP fits securely on the ceiling tile rail when hanging the
device from the ceiling; poor installation could cause it to fall onto people
or equipment.
Identifying known RF absorbers, reflectors, and interference sources while in
the field during the installation phase is critical. Make sure that these sources are
taken into consideration when you attach an IAP to its fixed location.

Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet.
Weitere Informationen bezlüglich Einschränkungen finden Sie im Aruba
Instant User Guide.
The snap-in tile rail slots on the rear of the IAP can be used to securely attach the
device directly to a 15/16" wide, standard ceiling tile rail.
1. Pull the necessary cables through a prepared hole in the ceiling tile near
where the IAP will be placed.
1. Power off the IAP.
2. Press and hold the reset button using a small, narrow object, such as a
paperclip.
Using the Integrated Ceiling Tile Rail Slots

Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
Cordless headset such as those used in call centers or lunch rooms
AP105_004
DC Power Socket
Access points are radio transmission devices and as such are subject to
governmental regulation. Network administrators responsible for the
configuration and operation of access points must comply with local
broadcast regulations. Specifically, access points must use channel
assignments appropriate to the location in which the access point will be
used.
AP105_003
Figure 1 IAP-105
3. Pushing toward the ceiling tile, rotate the IAP clockwise until the device
clicks into place on the ceiling tile rail.
Connecting Required Cables
Install cables in accordance with all applicable local and national regulations
and practices.
Ethernet Ports
The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/
MDX connections. Use these ports to connect the IAP to a twisted pair Ethernet
LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable up to 100 m (325
feet) long.
The 10/100/1000 Mbps Ethernet port is on the back of the IAP. The port has an RJ45 female connector with the pin-outs shown in Figure 6.
Figure 6 Gigabit Ethernet Port Pin-Out
1000Base-T Gigabit
Ethernet Port
RJ-45 Female
Pin-Out
Signal Name
Function
BI_DA+
BI_DABI_DB+
BI_DC+
BI_DCBI_DBBI_DD+
BI_DD-
Bi-directional pair +A
Bi-directional pair -A
Bi-directional pair +B
Bi-directional pair +C
Bi-directional pair -C
Bi-directional pair -B
Bi-directional pair +D
Bi-directional pair -D
Safety and Regulatory Compliance
Table 1 IAP-105 Series LED Meanings
LED
Color/State
Meaning
11B/G/N
Off
2.4 GHz radio disabled
Amber
2.4 GHz radio enabled in
WLAN mode
Green
2.4 GHz radio enabled in
11n mode
Green flashing
2.4 GHz Air Monitor or
RF Protect mode
Aruba Networks provides a multi-language document that contains countryspecific restrictions and additional safety and regulatory information for all
Aruba access points. This document can be viewed or downloaded from the
following location: www.arubanetworks.com/safety_addendum.
The device will be electronically labeled and the FCC ID will be displayed via the
controller Web UI under the About menu.
Serial Console Port
The serial console port (Console) allows you to connect the IAP to a serial
terminal or a laptop for direct local management. This port is an RJ-45 female
connector with the pinouts described in Figure 7. Connect this port in one of the
following ways:


Product Specifications
Electrical

Connect it directly to a terminal or terminal server using an Ethernet cable.
Use a modular adapter to convert the RJ-45 (female) connector on the IAP to
a DB-9 (male) connector, and connect the adapter to a laptop using an RS-232
cable. See Figure 8 for connector details of the adapter.
Figure 7 Serial Port Pin-Out
Serial
Console Port
RJ-45 Female
Pin-Out
Direction
Input
Output

TxD
GND
GND
RxD
If a power adapter other than the one provided by Aruba Networks is used
in the US or Canada, it should be cULus (NRTL) Listed, with an output
rated 12 VDC, minimum 1.25A, marked “LPS” or “Class 2,” and suitable for
plugging into a standard power receptacle in the US and Canada.
For additional specifications on this product, please refer to the data sheet. The
data sheet can be found at www.arubanetworks.com.
Figure 8 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion
Internal
Connections
RJ-45 Female
Pin-Out
TxD
GND
RxD
Direction
Input
Output
RJ-45
TxD
GND
RxD
DB-9 Male
Pin-Out
DB-9
Ground
RxD
TxD
Direction
Input
Output
Power Connection
The IAP-105 has a single 12V DC power jack socket to support powering through
an AC-to-DC power adapter.
If both POE and DC power are available, the IAP uses POE even when
there is not enough POE voltage available to power the IAP.
Verifying Post-Installation Connectivity
The integrated LEDs on the IAP can be used to verify that the IAP is receiving
power and initializing successfully (see Table 1). Refer to the Aruba Instant
Quick Start Guide for further details on verifying post-installation network
connectivity.
Table 1 IAP-105 Series LED Meanings
LED
Color/State
Meaning
PWR
Off
No power to IAP
Green flashing
System initializing
Red steady
System failed to
initialize, contact TAC
Green steady
Power on, device ready
Off
No link
Green on
1000 Mbps link
Amber on
10/100 Mbps link
Green flashing
Ethernet link activity
Off
5 GHz radio is disabled
Amber
5 GHz radio enabled in
WLAN mode
Green
5 GHz radio enabled in
11n mode
Green flashing
5 GHz Air Monitor or RF
Protect mode
ENET
(10/100/1000 Mbps)
11A/N
Ethernet:
 1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces
 MDI/MDX
 IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab
(1000Base-T)
 Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure
6 for pin configuration)
Power: 12 VDC power interface, supports powering through an AC-to-DC
power adapter
For the most current information about Global Environmental Compliance and
Aruba products, see our website at www.arubanetworks.com.


Aruba products at end of life are subject to separate collection
and treatment in the EU Member States, Norway, and
Switzerland and therefore are marked with the symbol shown
at the left (crossed-out wheelie bin). The treatment applied at
end of life of these products in these countries shall comply
with the applicable national laws of countries implementing
Directive 2002/96EC on Waste of Electrical and Electronic
Equipment (WEEE).
European Union RoHS
Aruba products also comply with the EU Restriction of
Hazardous Substances Directive 2002/95/EC (RoHS). EU
RoHS restricts the use of specific hazardous materials in
the manufacture of electrical and electronic equipment.
Specifically, restricted materials under the RoHS Directive are Lead (including
Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent
Chromium, and Bromine. Some Aruba products are subject to the exemptions
listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit
assemblies). Products and packaging will be marked with the “RoHS” label
shown at the left indicating conformance to this Directive.
China RoHS
10
Aruba products also comply with China environmental declaration
requirements and are labeled with the “EFUP 10” label shown at
the left.
IEC 60601-1-2: 2007
EN 60601-1-2: 2007
This equipment has been tested and found to comply with the limits of the
standard for medical devices, IEC 60601-1-2:2007. The unit also complies with the
requirements of EN 60601-1-2:2007, providing the presumption of compliance to
the European Union’s Medical Device Directive 2007/47/EC. The limits are
designed to provide reasonable protection against harmful interference in a
typical medical installation. This equipment generates, uses and can radiate radio
frequency energy, and, if not installed and used in accordance with the
manufacturer’s instructions may cause harmful interference to other devices in
the vicinity. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment causes interference with other devices,
which may be determined by turning the equipment off and on, the user is
encouraged to try and correct the interference by one or more of the following
measures:



Waste of Electrical and Electronic Equipment
Installation Guide
EMC Compliance and Warning Statement

Proper Disposal of Aruba Equipment
IAP-105 Wireless Access
Point
RF Radiation Exposure Statement: This equipment complies with FCC
RF radiation exposure limits. This equipment should be installed and
operated with a minimum distance of 13.78 inches (35 cm) between the
radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter
must not be co-located or operating in conjunction with any other antenna
or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this
device is restricted to indoor use to reduce the potential for harmful
interference with co-channel Mobile Satellite Systems.
Reorient or relocate the device receiving the interference.
Increase the separation between the equipment.
Connect the equipment into an outlet on a circuit different from that to which
the other device(s) are connected.
Consult the manufacturer or field service technician for help.
The Model IAP-105 does not have an Applied Part as defined in IEC 60601-1. The
protection against electric shock is Class ll.
Device is not protected against ingress of liquids and has a protection class of
IPX0 as defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in
the presence of flammable mixtures.
The unit is considered “Continuous Operation” equipment as defined by IEC
60601-1.
Power Consumption – 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for
external AC supplied power (adapter sold separately); Maximum power
consumption – 12.5W.
Mechanical Dimensions: 132mm x 135mm x 45mm; 300g.
Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5
to 95% non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F).
Contacting Aruba Networks
Table 1
Contact Center Online
Main Site
http://www.arubanetworks.com
Support Site
https://support.arubanetworks.com
Wireless Security Incident
Response Team (WSIRT)
http://www.arubanetworks.com/support/wsirt.php
EMEA Support Email
emea.support@arubanetworks.com
WSIRT Email
Please email details of any security
problem found in an Aruba product.
wsirt@arubanetworks.com
Table 2
Service & Support Contact Center Telephone
Aruba Corporate
+1 (408) 227-4500
FAX
+1 (408) 227-4550
Support
United States
Universal Free Phone Service Number (UIFN): Australia, Canada,
China, France, Germany, Hong Kong, Ireland, Israel, Japan, Korea,
Singapore, South Africa, Taiwan, and the UK
All Other Countries
800-WI-FI-LAN (800-943-4526)
+800-4WIFI-LAN (+800-49434-526)
+1 (408) 754-1200
Copyright
© 2011 Aruba Networks, Inc. AirWave®, Aruba Networks®, Aruba Mobility Management System®, Bluescanner,
For Wireless That Works®, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtect®, The All
Wireless Workplace Is Now Open For Business, and The Mobile Edge Company® are trademarks of Aruba
Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners.
Open Source Code
Certain Aruba products include Open Source software code developed by third parties, including software code
subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open
Source Licenses. The Open Source code used can be found at this site:
http://www.arubanetworks.com/open_source
Legal Notice
The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate
other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for
this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against
it with respect to infringement of copyright on behalf of those vendors.
Warranty
This hardware product is protected by the Aruba Limited Lifetime warranty.
Altering this device (such as painting it) voids the warranty.
www.arubanetworks.com
1344 Crossman Avenue
Sunnyvale, California 94089
Phone: 408.227.4500
Fax 408.227.4550
IAP-105 Wireless Access Point | Installation Guide
Part Number 0510860-03 | May 2011

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : dmontgomery
Create Date                     : 2009:07:01 16:54:10Z
Modify Date                     : 2011:08:22 17:28:22-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2011:08:22 17:28:22-07:00
Format                          : application/pdf
Title                           : IAP105_IG.fm
Creator                         : dmontgomery
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:3bc32b39-ebe3-45c0-83e0-56b5d3c62ed6
Instance ID                     : uuid:c0cbfd97-07df-4dfe-b92c-23c395495388
Page Mode                       : UseOutlines
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q9DAP105SDR

Navigation menu