Hewlett Packard Enterprise AP3750 AP3750 Managed Access Point User Manual YumaQSG
Hewlett-Packard Company AP3750 Managed Access Point YumaQSG
Users Manual
Quick Start Guide AP3750 Managed Access Point 3CRWX375075A The 3Com AP3750 Managed Access Point provides IEEE 802.11a and 802.11b/g wireless access to the network. The access point is designed for use with a 3Com Wireless LAN Switch, and requires hardware installation only. All configuration for the access point takes place on the 3Com Wireless LAN Switch. You must have a wireless switch device to operate the access point. Three WLAN switch devices can be connected to the access point: • • • 3Com WX4400 3Com WX1200 3Com WXR100 Power is supplied via Power Over Ethernet (PoE). The following 3Com PoE devices supply power to the access point: • • • • • • 3Com PoE Injector 3Com 4400PWR PoE Switch 3Com Multi-port PoE power supply 3Com 5500 Series PoE capable switches 3Com WX1200 3Com WXR100 About This Guide This Quick Start Guide describes the basic installation of the access point. It covers the following topics: • • • • • • • • • 3Com AP3750 Managed Access Point Features Observing Safety Precautions Step 1: Unpacking the Access Point Step 2: Preparing for Installation Step 3: Connecting External Antennas Step 4: Mounting the Access Point Step 5: Connecting the Access Point to a Switch Step 6: Configuring the Access Point Step 7: Checking the LED Indicators 3Com AP3750 Managed Access Point Features Diameter 16.76 cm (6.6 inches) Height 4.69 cm (1.85 inches) 840-9502-0040 TM External antenna connectors Kensington security slot 802.11a 840-9502-0007 Unlock 802.11b/g RJ-45 ports Port 2 Port 1 Kensington Security Slot The access point has a slot for attachment of a Kensington security cable. The cable is not included with the access point but can be ordered separately. Lock and Unlock Holes On one side of the access point there is a lock hole. On the other side there is an unlock hole. Insert a 3-mm or 1/8-inch screwdriver into the appropriate hole to attach and remove the access point from the mounting bracket. CAUTION: To prevent possible damage to the access point, do not use excessive force when inserting a tool into the lock or unlock hole. RJ-45 Cable Ports The access point has two RJ-45 ports. Each port provides a 10/100BASE-TX Ethernet connection to a WX switch. The connection can be direct to an WX switch or indirect through an intermediate Layer 2 or Layer 3 network. The access point receives power and data through the RJ-45 ports. Use a Category 5 (Cat 5) cable with straight-through signaling and standard RJ-45 connectors to connect an access point to a WX switch or other device in the network. The access point supports 802.3af, and also can receive PoE from 3Com switches and 3Com-approved power injectors. The two RJ-45 ports support dual-homed configurations for redundancy. The access point uses only one link for booting, configuration, and data transfer. If the link becomes unavailable, the access point can reboot using the other link. The ports are identical except for logical numbering (1 or 2). You can use either port to connect the access point to a WX switch. However, the access point always attempts to boot on port 1 first. Only if the boot attempt on port 1 fails does the access point attempt to boot on port 2. If one port becomes unavailable, the other port can provide full power to the access point. Note: The access point does not support daisy-chain configurations. Do not connect the access point to another AP3750 access point. External Antenna Connectors The access point has connectors for attaching optional external antennas. See “Connecting External Antennas” on page 5 for more information. Observing Safety Precautions This equipment must be installed in compliance with local and national building codes, regulatory restrictions, and FCC rules. For the safety of people and equipment, only professional network personnel should install the access point .\ WARNING: To comply with FCC radio frequency (RF) exposure limits, a minimum body-to- antenna distance of 20 cm (8 inches) must be maintained when the access point is operational. WARNING: To avoid possible injury or damage to equipment, you must use power supply equipment that is safety certified according to UL, CSA, IEC, or other applicable national or international safety requirements for the country of use. All references to power supply in this document refer to equipment meeting these requirements. WARNING: Do not operate the access point near unshielded blasting caps or in an otherwise explosive environment unless the device has been modified for such use by qualified personnel. WARNING: Do not touch or move the access point when the antennas are transmitting or receiving. WARNING: Do not hold any radio device so that the antenna is very close to or touching the face, eyes, or other exposed body part while the device’s radio antenna is transmitting. WARNING: Before using a wireless device in a hazardous location, consult the local codes, national codes, and safety directors of the location for usage constraints. WARNING: Do not connect or disconnect cables or otherwise work with the access point hardware during periods of lightning activity. NOTE: The access point is intended for indoor use only. Do not install the device outdoors, unless you install it in a properly installed enclosure. NOTE: To reduce the possibility of connection interference caused by dust, clean the Category 5 connector pins before inserting a cable into the access point. 1 Unpacking the Access Point Make sure that you have the following items, which are included with the access point: • • Mounting Kit: • One universal mounting bracket (attached to the access point) • One paper mounting template (used for marking cutting areas and screw holes) • One two-piece 14.2-mm (9/16-inch) T-bar clamp • One two-piece 15.9-mm (5/8-inch) T-bar clamp • One two-piece 23.9-mm (15/16-inch) T-bar clamp • Two #6 sheet metal screws and two drywall anchors Three adhesive rubber feet (used for a tabletop installation). 2 Preparing for Installation It is advisable to connect the power (if using an external power supply) and check the Ethernet cables and LEDs before installing the access point in a hard-to-reach location. Additionally, observe the following before mounting or connecting the access point: • Cabling Make sure that standard Category 5 cable with straight-through signaling is installed at the site before you install the access point. Make sure that the cable is highly flexible and that there is no extra covering on the RJ-45 connector that could prevent the cable from being routed through the mounting bracket • Power Power must be supplied via an 802.3af Power Over Ethernet (PoE)-compliant device. Removal of the Ethernet cable is the only method of disconnecting power from the access point. • MAC Address Record the access point MAC address in a safe place before the access point is installed in a hard-to-reach location. The MAC address is printed on the back of the access point. Additional MAC address labels are shipped with the access point. 3 Connecting External Antennas The access point has connectors for attaching optional external antennas and antenna cables. The tables below list the external antenna and cable models that are certified for use with the access point. Antenna Model Type 3CWE591 3Com 6/8 dBi Dual-Band Omnidirectional Antenna 3CWE597 3Com 4/6 dBi Dual-Band Hallway Antenna 3CWE598 3Com 8/10 dBi Dual-Band Panel Antenna Cable Model Type 3CWE580 3Com Ultra Low Loss 6-Foot Antenna Cable 3CWE581 3Com Ultra Low Loss 20-Foot Antenna Cable 3CWE582 3Com Ultra Low Loss 50-Foot Antenna Cable The 3Com antennas are dual-band, which means that they operate in both 2.4GHz and 5GHz spectra. You can use these antennas with either the 802.11b/g radio or the 802.11a radio. Each antenna requires the purchase of a separate antenna cable. NOTE: Antenna cables introduce loss of the RF signal. Always use the shortest cable that your application allows. For installation instructions, see the External Antenna Quick Start Guide that is part of the 3Com Wireless LAN Switch documentation set. NOTE: During the installation, connect the antenna to the access point before connecting the Category 5 Ethernet cable. This ensures that the access point is not powered on when the access point is connected to the network. 4 Mounting the Access Point The access point can be mounted on the following types of surfaces: • • • • • Suspended ceiling — flush ceiling tiles Suspended ceiling — drop ceiling tiles Junction box Solid wall or ceiling Tabletop Cable Requirement The Ethernet ports on the access point cannot accept a Category 5 cable that has an uneven sheath such as the one shown in the figure below. The RJ-45 connector on the cable will not seat properly in the receptacle on the access point. Use a Category 5 cable with an even sheath instead. Uneven sheath Suspended Ceiling — Flush Ceiling Tiles This procedure applies to T-bars that are 23.9 mm (15/16 inches) wide. For a 14.2-mm (9/16-inch) or 15.9-mm (5/8-inch) T-bar, go to “Suspended Ceiling Installation — Drop Ceiling Tiles” on page 8. TM point Mounting template Mounting template Mounting bracket Mounting bracket Use the mounting template to cut a hole for the Category 5 cable. Remove the mounting bracket from the access point. 840-9502-0011 840-9502-0008 Mobility AP3750 access point 3 Attach the mounting bracket to the T-bar clamp. Universal mounting bracket Port connector opening Universal mounting bracket T-bar T-bar 840-9502-0005 Port connector opening (Viewed from above ceiling tiles, looking down.) If you are using an external antenna, insert the antenna cable into the antenna connector on the access point. Insert the Category 5 cable through the port connector opening in the mounting bracket, then plug the cable into the access point. 840-9502-0002 TM Attach the access point to the mounting bracket Lock T-bar TM TM 840-9502-0006 CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the antenna at least 20 cm from the access point. Suspended Ceiling Installation — Drop Ceiling Tiles This procedure applies to T-bars that are 23.9 mm (15/16 inches), 14.2 mm (9/16 inches), or 15.9 mm (5/8 inches) wide. You can also use this procedure for flush ceilings with 14.2-mm (9/16-inch) or 15.9mm (5/8-inch) T-bars. TM Mobility AP3750 access point point Mounting Mounting template T-bar T-barclamps clamps (use (useset setthat thatfits fitsT-bar) T-bar) template Use the mounting template to cut a hole for the Category 5 cable. Install the T-bar clamp that fits the T-bar. T-bar Slide together 840-9502-0003 T-bar clamp halves 23.9-mm (15/16-in) or 14.2-mm (9/16-in) T-bar (The clamps are different widths but the assembly is the same.) T-bar Slide together 840-9502-0066 T-bar clamp halves 15.9-mm (5/8-in) T-bar Mounting Mounting bracket bracket Remove the mounting bracket from the access point. Attach the mounting bracket to the T-bar clamp. 840-9502-0011 840-9502-0008 Universal mounting bracket Port connector opening T- bar Universal mounting bracket T-bar 840-9502-0012 T-bar clamps (attached to T-bar) Port connector opening (Viewed from above ceiling tiles, looking down.) If you are using an external antenna, insert the antenna cable into the antenna connector on the access point. Insert the Category 5 cable through the port connector opening in the mounting bracket, then plug the cable into the access point. 840-9502-0002 TM 7 Attach the access point to the mounting bracket. Lock TM TM 840-9502-0006 T-bar CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the antenna at least 20 cm from the access point. Junction Box Installation TM Mobility point AP3750 access point Mounting hardware Mounting hardware 10 840-9502-0008 Remove the mounting bracket from the access point. 840-9502-0011 Mounting Mounting bracket bracket 2 Attach the bracket to the junction box. Junction box 840-9502-0017 Port connector opening If you are using an external antenna, insert the antenna cable into the antenna connector on the access point. Plug the Category 5 cable into the access point and attach the access point to the mounting bracket. TM 840-9502-0062 TM Lock CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the antenna at least 20 cm from the access point. 11 Solid Wall or Ceiling Installation TM Mobility AP3750 access point point Mounting Mounting template template Mounting Mounting bracket bracket Use the mounting template to cut a hole for the Category 5 cable. Remove the mounting bracket from the access point. Attach the bracket to the wall or ceiling. 840-9502-0011 840-9502-0008 Mounting Mounting hardware hardware 840-9502-0015 TM If you are using an external antenna, insert the antenna cable into the antenna connector on the access point. 12 Plug the Category 5 cable into the access point and attach the access point to the mounting bracket. Cable TM 840-9502-0016 Universal mounting bracket TM TM 840-9502-0062 Lock CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the antenna at least 20 cm from the access point. 13 Tabletop Installation TM point Mounting Mounting bracket bracket Remove the mounting bracket from the access point. Reverse the bracket and reattach it to the access point. Attach the rubber feet. Turn the access point over and place it on the table. 840-9502-0013 840-9502-0061 840-9502-0011 14 Rubber Rubber feet feet 840-9502-0008 Mobility AP3750 access point 5 If you are using an external antenna, insert the antenna cable into the antenna connector on the access point. Plug the Category 5 cable into the access point. CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the antenna at least 20 cm from the access point. 5 Connecting the Access Point to a Switch 3Com recommends that you install and configure the 3Com Wireless LAN Switch before installing the access point. If the switch is already installed and configured for the access point, you can immediately verify the cable connection when you plug the cable into the access point. WARNING: Do not connect or disconnect cables or otherwise work with the access point during periods of lightning activity. You can connect the access point directly to a 3Com Wireless LAN Switch port or indirectly to 3Com Wireless LAN switches through an intermediate Layer 2 or Layer 3 network. In either case, use Category 5 cable with straight-through signaling for each access point connection. • To connect the access point directly to a 3Com Wireless LAN Switch, configure the switch port as an AP3750 managed access point and then insert the cable into the switch and verify the link. • To connect the access point indirectly to a 3Com Wireless LAN Switch through the network, configure a Distributed Access Point connection on the switch. Note: You can use the CLI or 3WXM to configure an AP3750 access port or Distributed Access Point connection. See the 3Com Wireless LAN Switch and Controller Configuration Guide or the 3Com Wireless LAN Switch Reference Manual. 6 Configuring the Access Point To configure the channels, power settings, and other access point parameters, see the following: • • “Configuring a WX Switch for Basic Service” chapter in the 3Com Wireless LAN Switch and Controller Installation and Basic Configuration Guide. “Configuring MAP Access Points” chapter in the 3Com Wireless LAN Switch and Controller Configuration Guide. 15 7 Checking the LED Indicators When the access point is connected to power, LEDs indicate activity as follows: Radio 1 LED Radio 2 LED Health LED LEDs Color Health Solid green Indicates • • • • Radio 1 (.11b/g) Radio 2 (.11a) 840-9502-0010 TM The access point has a valid management link with a wireless switch. The access point has booted. The access point has received a valid configuration from a wireless switch. At least one radio is enabled or is in sentry mode on the access point. Solid amber The access point is waiting to receive boot instructions and a configuration file from a wireless switch. Alternating green and amber The access point is booting and receiving its configuration file from a wireless switch. Solid green A client is associated with the radio. Blinking green Associated client is sending or receiving traffic. Blinking amber Non-associated client is sending or receiving traffic. Alternating green and amber The radio is unable to transmit. This state can occur because of any of the following: • Excessive radio interference in the environment is preventing the radio from sending beacons. • The radio has failed. Unlit The radio is disabled. If the radio is enabled, no clients are associated with the radio and there is no traffic activity. 16 Regulatory Information The 3Com AP3750 Managed Access Point (3CRWX375075A) must be installed and used in strict accordance with the manufacturer's instructions as described in the user documentation that comes with the product. Note: This product contains encryption. It is unlawful to export out of the U.S. without obtaining a U.S. Export License. This product does not contain any user serviceable components. Any unauthorized product changes or modifications will invalidate 3Com's warranty and all applicable regulatory certifications and approvals. This product must be installed by a professional technician/installer. CAUTION: EXPOSURE TO RADIO FREQUENCY RADIATION This device generates and radiates radio-frequency energy. In order to comply with FCC radio-frequency exposure guidelines for an uncontrolled environment, this equipment must be installed and operated while maintaining a minimum body-toantenna distance of 20 cm (approximately 8 in.). The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada's website www.hc-sc.gc.ca/rpb. This product must maintain a minimum body-to-antenna distance of 20 cm. Under these conditions this product will meet the Basic Restriction limits of 1999/519/EC [Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)]. USA - RADIO FREQUENCY REQUIREMENTS. This device must not be co-located or operated in conjunction with any other antenna or transmitter. This device is for indoor use only when using channels 36, 40, 44 or 48 in the 5.15 to 5.25 GHz frequency range. High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with and/or damage this device. USA-FEDERAL COMMUNICATIONS COMMISSION (FCC) EMC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the distance between the equipment and the receiver • Connect the equipment to outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help The user may find the following booklet prepared by the Federal Communications Commission helpful: The Interference Handbook This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock No. 004-000-0034504. 3Com is not responsible for any radio or television interference caused by unauthorized modification of the devices included with this 3Com AP3750 Managed Access Point (3CRWX375075A), or the substitution or attachment of connecting cables and equipment other than specified by 3Com. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. Changes or modifications not expressly approved by 3Com could void the user’s authority to operate this equipment. 17 MANUFACTURER'S FCC DECLARATION OF CONFORMITY 3Com Corporation 350 Campus Drive Marlborough, MA 01752-3064, USA (800) 527-8677 Date: May 6, 2005 Declares that the Product: Brand Name: 3Com Corporation Model Number: AP3750 Equipment Type: Managed Access Point Complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3Com AP3750 Managed Access Point Model AP3750 INDUSTRY CANADA (IC) - RF Compliance This device complies with RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. L ' utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit pas produire de brouillage et (2) l' utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. The term "IC" before the equipment certification number only signifies that the Industry Canada technical specifications were met. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing. Pour empêcher que cet appareil cause du brouillage au service faisant l'objet d'une licence, il doit être utilise a l'intérieur et devrait être place loin des fenêtres afin de Fournier un écran de blindage maximal. Si le matériel (ou son antenne d'émission) est installe a l'extérieur, il doit faire l'objet d'une licence. High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with and/or damage this device. INDUSTRY CANADA (IC) EMISSIONS COMPLIANCE STATEMENT This Class B digital apparatus complies with Canadian ICES-003. AVIS DE CONFORMITÉ À LA RÉGLEMENTATION D'INDUSTRIE CANADA Cet appareil numérique de la classe B est conform à la norme NMB-003 du Canada. SAFETY COMPLIANCE NOTICE This device has been tested and certified according to the following safety standards and is intended for use only in Information Technology Equipment which has been tested to these or other equivalent standards: • UL Standard 60950 (3rd Edition) • CAN/CSA C22.2 No. 60950 • IEC 60950 • EN 60950 18 EUROPE - EU DECLARATION OF CONFORMITY This equipment may be operated in AT BE CY CZ DK EE FI FR DE GR HU IE IT LV LT LU MT NL PL PT SK SI ES SE GB IS LI NO CH BG RO TR Intended use: IEEE 802.11a/b/g radio LAN device NOTE: To ensure product operation is in compliance with local regulations, select the country in which the product is installed. Refer to the Wireless LAN Mobility System, Wireless LAN Switch and Controller Configuration Guide. EUROPE - DECLARATION OF CONFORMITY IN LANGUAGES OF THE EUROPEAN COMMUNITY English Hereby, 3Com Corporation, declares that this RLAN device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Finnish 3Com Corporation vakuuttaa täten että RLAN device tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Dutch Hierbij verklaart 3Com Corporation dat het toestel RLAN device in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart 3Com Corporation dat deze RLAN device voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC. French Par la présente 3Com Corporation déclare que l'appareil RLAN device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Par la présente, 3Com Corporation déclare que ce RLAN device est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables. Swedish Härmed intygar 3Com Corporation att denna RLAN device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Danish Undertegnede 3Com Corporation erklærer herved, at følgende udstyr RLAN device overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. German Hiermit erklärt 3Com Corporation, dass sich dieser/diese/dieses RLAN device in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi) Hiermit erklärt 3Com Corporation die Übereinstimmung des Gerätes RLAN device mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien). Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ 3Com Corporation ∆ΗΛΩΝΕΙ ΟΤΙ RLAN device ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΕ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΕΕΙΣ ΤΗΣ Ο∆ΗΠΑΣ 1999/5/ EK. Italian Con la presente 3Com Corporation dichiara che questo RLAN device è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Spanish Por medio de la presente 3Com Corporation declara que el RLAN device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. 19 Portuguese 3Com Corporation declara que este RLAN device está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Malti Hawnhekk, 3Com Corporation, jiddikjara li dan RLAN device jikkonforma mal-htigijiet essenzjali u ma provvedimenti ohrajn relevant li hemm fid-Dirrettiva 1999/5/EC. Estonian Käesolevaga kinnitab 3Com Corporation seadme RLAN device vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Hungarian Alulírott, 3Com Corporation nyilatkozom, hogy a RLAN device megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Slovak 3Com Corporation týmto vyhlasuje, že RLAN device spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Czech 3Com Corporation tímto prohlašuje, že tento RLAN device je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Slovene Lithuanian Latvian Šiuo 3Com Corporation deklaruoja, kad šis RLAN device atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Šiuo 3Com Corporation deklaruoja, kad šis RLAN device atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Ar šo 3Com Corporation deklarē, ka RLAN device atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. A copy of the signed Declaration of Conformity can be downloaded from the Product Support web page for the AP3750 (3CRWX375075A) at http://www.3com.com. Also available at http://support.3com.com/AP3750_EU_DOC.pdf EUROPE - RESTRICTIONS FOR USE OF 2.4GHZ FREQUENCIES IN EUROPEAN COMMUNITY COUNTRIES This device may be operated indoors or outdoors in all countries of the European Community using the 2.4GHz band: Channels 1 - 13, except where noted below. • In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors. • In Belgium outdoor operation is only permitted using the 2.46 - 2.4835 GHz band: Channel 13. • In France outdoor operation is only permitted using the 2.4 - 2.454 GHz band: Channels 1 - 7. 20 EUROPE - RESTRICTIONS FOR USE OF 5GHZ FREQUENCIES IN EUROPEAN COMMUNITY COUNTRIES Allowed Frequency Bands Allowed Channel Numbers Countries 5.15-5.25 GHz 36, 40, 44, 48 Austria 5.15-5.35 GHz 36, 40, 44, 48, 52, 56, 60, 64 Belgium, Cyprus, Czech Republic, France, Hungary, Liechtenstein, Slovakia, Switzerland 5.15-5.35 & 5.470-5.725GHz 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140 Bulgaria, Denmark, Estonia, Finland, Germany, Greece, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovenia, Spain, Sweden, U.K. • This device may be not be operated outdoors when using the bands 5150-5350MHz (Channels 36, 40, 44, 48, 52, 56, 50, 64). • In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors. • To remain in conformance with European spectrum usage laws for Wireless LAN operation, the above 2.4GHz and 5GHz channel limitations apply. The user should check the current channel of operation. If operation is occurring outside of the allowable frequencies as listed above, the user must cease operating the Managed Access Point at that location and consult the local technical support staff responsible for the wireless network. • The 5GHz Turbo mode feature is not allowed for operation in any European Community country. • This device must be used with the radar detection feature required for European Community operation in the 5GHz bands. This device will avoid operating on a channel occupied by any radar system in the area. The presence of nearby radar operation may result in temporary interruption in communications of this device. The Access Point's radar detection feature will automatically restart operation on a channel free of radar. You may consult with the local technical support staff responsible for the wireless network to ensure the Access Point device(s) are properly configured for European Community operation. • Radio detection, as described above, is automatically enabled when the selected country of operation is within the European Community. • To reduce potential radio interference to other users, output power and antenna gain should be no higher than that necessary for successful communication. The RF Auto-Tuning feature may be used to assist with this. Brazil RF Compliance Este equipamento opera em caráter secundário, isto é, năo tem direito a proteçăo contra interferęncia prejudicial, mesmo de estaçőes do mesmo tipo, e năo causar interferęncia a sistema operando em caráter primário. 21 Copyright © 2005 3Com Corporation. All rights reserved. 3Com and the 3Com logo are registered trademarks of 3Com Corporation. All other company and product names may be trademarks of the respective companies with which they are associated. DQA37507-5AAA01 Published May 2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Page Count : 22 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0e0509c0-9648-456d-85c0-44109367027f Producer : Acrobat Distiller 5.0.5 (Windows) Create Date : 2004:06:07 08:29:23Z Modify Date : 2005:05:27 21:08:46+08:00 Metadata Date : 2005:05:27 21:08:46+08:00 Creator Tool : FrameMaker 7.0 Document ID : uuid:9e370832-045e-40b6-99c9-ea53880698ba Format : application/pdf Creator : Shelley Bandy Title : YumaQSG.fm Tagged PDF : Yes Author : Shelley BandyEXIF Metadata provided by EXIF.tools