Hewlett Packard Enterprise APIN0207 Wireless Access Point User Manual 207 Series RCSI Guide Rev03
Aruba Networks, Inc. Wireless Access Point 207 Series RCSI Guide Rev03
Contents
- 1. User Manual
- 2. User Manual Regulatory
- 3. User Manual Warning
User Manual Warning
Aruba 207 Series Wireless Access Point
Regulatory Compliance and Safety Information Guide
0511889-03 | September 2016 1
Introduction
This document contains domestic and international regulatory compliance and safety information for the access
point. To ensure that this device complies with the regulatory standards for your region, please refer to the
sections below.
Electrical and Environmental Specifications
Regulatory Information
Proper Disposal of Aruba Equipment
Electrical and Environmental Specifications
For additional specifications on this product, please refer to the product data sheet at www.arubanetworks.com.
Electrical
Ethernet:
One 10/100/1000 Base-T auto-sensing Ethernet interface (RJ-45)
Power:
Maximum power consumption (excluding USB):13.5W (PoE) or 12W (DC)
Direct DC source: 12Vdc nominal, +/- 5%
Power over Ethernet (PoE): 802.3af complaint source
Connect only to IEC 60950-1 or IEC 60601-1 3rd edition products and power sources.
Environmental
Operating:
Temperature: 0°C to +40°C (+32°F to +104°F)
Humidity: 5% to 93% non-condensing
Storage and transport
Temperature: -40°C to +70°C (40°F to +158°F)
Regulatory Information
The following regulatory model names apply to the 207 Series access points:
AP-207/IAP-207: APIN0207
Aruba provides a multi-language document that contains country-specific restrictions and additional safety and
regulatory information for all Aruba access points. This document can be viewed or downloaded from the
following location: www.arubanetworks.com/safety_addendum.
All Aruba access points should be professionally installed by an Aruba Certified Mobility Professional (ACMP).
The installer is responsible for ensuring that grounding is available and meets applicable national and electrical
codes.
Tous les points d'accès Aruba doivent impérativement être installés par un professionnel agréé. Ce dernier
doit s'assurer que l'appareil est mis à la terre et que le circuit de mise à la terre est conforme aux codes
électriques nationaux en vigueur.
If a power adapter other than the Aruba-approved adapter is used in the US or Canada, it should be NRTL
listed, without an output rated 12Vdc, minimum 2A, marked “LPS” and “Class 2”, and suitable for plugging into
a standard power receptacle in the US and Canada.
2Aruba 207 Series Wireless Access Point | Regulatory Compliance and Safety Information Guide
FCC
FCC Class B Part 15
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instructions, may cause interference harmful to radio
communications.
Operation is subject to the following conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired
operation.
If this equipment does cause interference, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio or TV technician for help.
Canada
Complies with the Class B limits for radio noise emissions as set out in the interference-causing equipment
standard entitled “Digital Apparatus,” CAN ICES-3(B)/NMB-3(B).
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and
maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio
interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired operation of the device.
Déclaration d’Industrie Canada
Cet appareil numerique de la classe B respecte toutes les exigencies du Reglement sur le materiel brouilleur du
Canada.
RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This
equipment should be installed and operated with a minimum distance of 7.87 inches (20cm) between the
radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
Déclaration sur les limites d'exposition aux radiofréquences :cet équipement est conforme aux limites
d'exposition aux rayonnements radioélectriques spécifiées par la FCC. Il doit être installé et utilisé à une
distance minimale de 20 cm par rapport à votre corps pour les fréquences de 2,4 et 5 GHz. Cet émetteur-
récepteur ne doit pas être utilisé ou situé à proximité d'autres antennes ou émetteurs-récepteurs.
The device could automatically discontinue transmission in case of absence of information to transmit, or
operational failure. Note that this is not intended to prohibit transmission of control or signaling information
or the use of repetitive codes where required by the technology.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
Toute modification effectuée sur cet équipement sans l'autorisation expresse de la partie responsable de la
conformité est susceptible d'annuler son droit d'utilisation.
Aruba 207 Series Wireless Access Point | Regulatory Compliance and Safety Information Guide 3
Conformément aux réglementations d’Industrie Canada, cet émetteur-récepteur radio doit être utilisé
uniquement avec une antenne dont le type et le gain maximal doivent être approuvés par Industrie Canada.
Pour réduire les interférences radio potentielles, le type d’antenne et son gain doivent être choisis de façon à ce
que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas les valeurs nécessaires à une
communication efficace.
Ce périphérique est conforme aux règlements RSS exempts de licence d’Industrie Canada. L’utilisation de ce
périphérique est soumise aux deux conditions suivantes : (1) ce périphérique ne doit pas provoquer d’interférences, et
(2) ce périphérique doit accepter toute interférence, y compris les interférences susceptibles de provoquer un
dysfonctionnement.
EU Regulatory Conformance
Aruba Networks Inc., hereby declares that the 320 Series Wireless Access Points are in compliance
with directives listed below:
EMC Directive 2004
Low Voltage Directive 2006
R&TTE Directive 1999
REACH Regulation (EC) No.: 1907/2006
RoHS Directive 2011
WEEE Directive 2002
A Declaration of Conformity for these directives is available for viewing at www.arubanetworks.com.
Users are advised that high power Radars are allocated as primary users of the bands 5250-5350 MHz and 5650-
5850
MHz and these Radars could cause interference and/or damage to Licensed Exempt WLAN devices.
Medical
1. Equipment not suitable for use in the presence of flammable mixtures.
2. Connect to only IEC 60950-1 or IEC 60601-1 3rd edition certified products and power sources. The end user is
responsible for the resulting medical system complies with the requirements of IEC 60601-1 3rd edition.
3. Wipe with a dry cloth, no additional maintenance required.
4. No serviceable parts, the unit must be sent back to the manufacturer for repair.
5. No modifications are allowed without Aruba approval.
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。
This equipment complies with IC RSS-102 RF exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20 cm between the radiator and your
body.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement
non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la
source de rayonnement et votre corps.
Under Industry Canada regulations, when operated in 5150 to 5250 MHz frequency range, this device is
restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite
Systems. Users are advised that high power radars are allocated as primary users (i.e. priority users) of the
bands 5250-5350 MHz and 5650-5850MHz and that these radars could cause interference and/or damage to
LE-LAN devices.
Conformément aux réglementations d’Industrie Canada, en cas d'utilisation dans la plage de fréquences de
5150 à 5250 MHz, cet appareil doit uniquement être utilisé en intérieur afin de réduire les risques
d'interférence avec les systèmes satellites mobiles partageant le même canal. Les utilisateurs êtes avisés que
les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu'ils ont la priorité)
pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des
dommages aux dispositifs LAN-EL
© Copyright 2016 Hewlett Packard Enterprise Development LP
www.arubanetworks.com
1344 Crossman Avenue
Sunnyvale, California 94089
Phone: 408.227.4500
Fax: 408.227.4550
4Aruba 207 Series Wireless Access Point | Regulatory Compliance and Safety Information Guide
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。
前項合法通信,指依電信法規定作業之無線電通信。
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電 機設備之干擾。
Proper Disposal of Aruba Equipment
Dispose of Aruba products per local regulation. For the most current information about Global Environmental
Compliance and Aruba products, see our website at www.arubanetworks.com.
Waste of Electrical and Electronic Equipment
Aruba products at end of life are subject to separate collection and treatment in the EU
Member States, Norway, and Switzerland and therefore are marked with the symbol shown at
the left (crossed-out wheelie bin). The treatment applied at end of life of these products in
these countries shall comply with the applicable national laws of countries implementing
Directive 2002/96EC on Waste of Electrical and Electronic Equipment (WEEE).
India RoHS
This product complies with RoHS requirements as prescribed by E-Waste (Management & Handling) Rules,
governed by the Ministry of Environment & Forests, Government of India.
European Union RoHS
Aruba products also comply with the EU Restriction of Hazardous Substances Directive
2011/65/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the
manufacture of electrical and electronic equipment. Specifically, restricted materials
under the RoHS Directive are Lead (including Solder used in printed circuit assemblies),
Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions
listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will
be marked with the “RoHS” label shown at the left indicating conformance to this directive.
China RoHS
Aruba products also comply with China environmental declaration requirements and are labeled
with the “EFUP 25” label shown at the left.
Expected Service Life 10 years. For additional compliance information, refer to the label on the side of this device.
ᴹᴹ∂ᴹᇣ⢙䍘༠᰾
Hazardous Materials Declaration
䜘Ԧ〠
(Parts)
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐˄Hazardous Substance˅
䫵
˄Pb˅
⊎
˄Hg˅
䭹
˄Cd˅
ޝԧ䬜
˄Cr6+˅
ཊⓤ㚄㤟
˄PBB˅
ཊⓤҼ㤟䟊
˄PBDE˅
⭥䐟⁑ඇ
(circuit modules) X
O
O
O
O
O
⭥㔶৺⭥㔶㓴Ԧ
(Cables & Cable A
ssemblies)
O
O
O
O
O
O
䠁䜘Ԧ
(Metal Parts) O
O
O
O
O
O
ກᯉ઼㚊ਸ⢙䜘Ԧ
(
Plastic and Polymeric Parts)
O
O
O
O
O
O
O: 㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴਜ਼䟿൷൘ SJ/T11363-2006 ḷ߶㿴ᇊⲴ䲀䟿㾱≲
ԕлDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts
is below the relevant threshold of the SJ/T11363-2006 standard.
X: 㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴਜ਼䟿䎵ࠪ SJ/T11363-2006 ḷ߶㿴ᇊⲴ䲀
䟿㾱≲DŽIndicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard.
ሩ䬰ѻᰕⲴᡰӗ૱ˈᵜ㺘ᱮ⽪ᓄ䬮Ⲵ⭥ᆀؑӗ૱ਟ㜭वਜ਼䘉Ӌ⢙䍘DŽ
This table shows where these substances may be found in the supply chain of
electronic information
products, as
of the date of sal
e of the enclosed product.
↔ḷᘇѪ䪸ሩᡰ⎹৺ӗ૱Ⲵ⧟؍֯⭘ᵏḷᘇ. ḀӋ䴦䜘ԦՊᴹањн਼Ⲵ⧟؍֯⭘ᵏ
(
ֻྲ,⭥⊐অݳ⁑ඇ)䍤൘ަӗ૱к.
↔⧟؍֯⭘ᵏ䲀ਚ䘲⭘Ҿӗ૱ᱟ൘ӗ૱ѝᡰ㿴ᇊⲴᶑԦлᐕ.
The Environment
-
Friendly Use Period (EFUP) for all enclosed products and their parts are
per the symbol shown here. The Environment
-
Friendly Use Period is valid only when the
product is operated under the conditions defined in the product manual.