Display FormatAdobe Acrobat PDF - pdf
Filesize59.16kB (739537 bits)
Date Submitted2012-05-15 00:00:00
Date Available2012-05-30 00:00:00
Creation Date2012-03-16 10:33:47
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2012-03-16 10:33:47
Document TitleMicrosoft Word - MST200 Installation Guide PD60E-001
Document CreatorPScript5.dll Version 5.2.2
Document Author: wakeyouw

Aruba Networks
MST200 Installation Guide
Copyright 2005-2010 by Aruba Networks, USA.
All rights reserved.
Statement of Conditions
In the interest of improving internal design, operation function, and/or reliability, Aruba Networks
reserves the right to make changes to products described in this document without notice. Aruba
Networks does not assume any liability that may occur due to the use or application of the product(s)
described herein.
DISCLAIMER: LIMITATION OF LIABILITY
1.Before installation, it’s strongly recommended and requested that users pay particular attention to the
safety warnings in the sequentially detailed operation procedures within the manual. If there’s any
uncertainty or incapability of solving problems, contact the company’s customer support center. Please
DO NOT incur any risk or try to verify situations by yourself. Otherwise, any consequence caused by
the attempt shall be completely due to the user himself.
2.Please periodically check whether the installed MST200 is damaged, worn-out or poses any danger.
Any actual proof, sign or phenomenon of the afore-mentioned situations should be brought to the
attention of the company at point of sale. Please DO NOT attempt to repair the product or replace any
component. Otherwise, for any consequence arising out of or relating to the users’ attempt repair the
product, including but not limited to damages, disuse, short circuit, fire, bodily injury, etc., the company
shall not be liable.
3. Users shall purchase or use the company’s MST200 voluntarily. Users shall understand on their own
initiative and abide voluntarily by policies, regulations or laws of their respective nation or local
territories. The consequence arising out of or relating to any violation of the local laws or regulations by
the user, shall be solely imputed to the user himself, and the company shall not be liable.
4. The company disclaims any and all warranties and guarantees, express, implied or otherwise, arising,
with respect to the MST200 products or services, including but not limited to the warranty of
merchandisability, the warranty of fitness for a particular purpose, and any warranty of non-infringement
of the intellectual property rights of any third party. Liability of the company for loss is limited to the total
amount paid to the company by the customer during the previous calendar year. The company will have
no obligation or liability, whether arising in contract (including Warranty), tort (including active, passive
or imputed negligence, strict liability or product liability) or otherwise for any special, incidental,
MST200 Installation Guide
consequential or indirect damages including but not limited to loss of use, loss of data, business
interruption, loss of revenue, loss of business or other financial loss arising out of or in connection with
any of the products or other goods or services furnished by the company under this manual, even if
advised of the possibility of such damages.
5.It shall never be understood that the manual expresses or implies to any customer or any third
party authorize or transfer any rights. The company reserves fully the final interpretation of the
MST200 and this manual.
Safety Warnings
The MST200 must be installed by trained professional installation technicians. All warnings below must
be read and understood before installation.
General Safety Warnings
You can be killed or injured if performing antenna installation near electrical power lines.
Carefully read and follow all instructions in this guide. Please be sure there are no high voltage and
electronic fields nearby.
Working Aloft Warning
When working on tower or roof, individuals must wear safety belts. Tools must be tied to
the individual using them. Workers below must wear safety helmets.
Lightning Activity Warning
Make sure not to connect or disconnect cables during periods of lightning activity.
A surge protective device should be installed to prevent potential damage from very high surges, for
instance, the peak surges caused by lightning.
MST200 Installation Guide
Explosive Device Proximity Warning
Do not operate wireless network devices close to explosive merchandise or in explosive
environments, for example, in the vicinity of a gas station.
Antenna Placement Warning
Do not install any antenna near overhead power lines or other electric light, or where the
antenna can come into contact with such circuits.
Antenna Selection Warning
Please use DC grounding antenna with lightning protection to prevent surge and static
electricity.
Grounding Warning
Please always remember to protect your MST200 system by installation of grounding lines.
The ground connection must be complete before connecting power to the MST200 enclosure. The
requirement of grounding is to make sure the resistance must be less than 5 ohm between the
ground termination point to grounding tier.
Power Installation Warning
The installation of the power switch must be performed by a trained professional technician.
The power switch is not supplied with the MST200. The power cord must be assembled by a
professional installer, and the final assembly must comply with related requirements.
MST200 Installation Guide
Solar Irradiation and High Temperature Protection
Pay attention to level of sunlight, which can increase the working temperature of MST200 to
higher than specifications allow.
A solar shield is provided in the Aruba standard package and should be installed to protect any
outdoor MST200. The Aruba Warrantee policy does not cover those outdoor products for which
Solar shields are not installed. Please contact Aruba technical support engineers for detailed
information.
RF Device Protection
Before powering up the MST200, the RF port must be connected to an antenna or a valid
load (not included in the standard accessories for MST200). Otherwise, the RF module may be
burned out. Aruba will not take any responsibility for such damage. For RF module with power less
than 100mW, in test environment, it is allowed worked without load but should be within 30 minutes.
Protection on unused RF module
The unused RF interface must be closed via configuration command and its protective cap must be
wrapped up by waterproof PVC tape to prevent from falling off. Otherwise, the RF module may be
damaged. Aruba will not take any responsibility for such damage.
FCC Certificate
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
REMINDER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
MST200 Installation Guide
NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
Precautions
The radiated output power of this device is below the FCC radio frequency exposure limits based on
that human proximity to the antenna shall not be less than 20cm during normal operation.
IC notice
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Region Selection
Limited by local law regulations, version for North America does not have region selection option.
MST200 Installation Guide
Table of Contents
PRODUCT OVERVIEW ................................................................................................................................................. 7
1.1
INSTALLATION PREPARATIONS .............................................................................................................................. 8
2.1
2.2
PREPARING INSTALLATION TOOLS............................................................................................................................ 8
EXAMINING THE INSTALLATION SITE ......................................................................................................................... 8
MST200 INSTALLATION .............................................................................................................................................. 9
3.1
3.2
3.3
INTERFACES .............................................................................................................................................................. 7
INSTALLING MST200 ON A POLE .............................................................................................................................. 9
GROUNDING THE MST200 ..................................................................................................................................... 14
CONNECTING THE ETHERNET CABLE ...................................................................................................................... 15
NOTE .............................................................................................................................................................................. 17
MST200 Installation Guide
1 Product Overview
1.1
Interfaces
Figure 1-1 Interfaces on MST200
Ethernet interface (POE)
Grounding hole
MST200 Installation Guide
USB console interface
2 Installation Preparations
This chapter describes the preparations for MST200 installation, including preparation of installation
tools,selection of installation sites and etc.
2.1
Preparing Installation Tools
When installing MST200, you may need the following tools. You shall select the tools according to the actual
situation.
Table 2-1 Installation tools list
Type
Tools
Screwdriver, adjustable spanner, vice, safety belt, hard hat, power
General tools
board (220 VAC or as required by local regulation), POE power
injector, crimping pliers, electric soldering iron, welding wire, PVC
insulation tape, adhesive insulation tape, strap, insulation tools
2.2
Examining the Installation Site
1. The site should be located within at least a 60% range of the 1st fresnel zone without obstacles to
provide LOS transmission, increase coverage capacity, and minimize the number of necessary
sites.
2. If no LOS secured, area in NLOS area could be covered as well, but the distance of coverage and
area of coverage are decreased; more sites are needed to provide coverage for same area than in
the LOS scenario.
3. Interference must be considered in site selection. New site should avoid known interference, unless
the interference is controllable.
4. Keep the MST200 away from places that are susceptible to high temperature, dust, harmful gas,
inflammable, explosive, electromagnetic interference (high power radar, radio station and
transformer), unstable voltage, heavy vibration, or loud noise. In engineering design, the site should
be selected according to the network planning and technical requirements of communications
equipment, as well as the considerations such as climate, hydrology, geology, earthquake, electric
power, and transportation.
MST200 Installation Guide
3 MST200 Installation
The installation flowchart of MST200:
3.1
Installing MST200 on a pole
The mounting assembly for installing MST200 concludes: a pair of pole anchors, a positioning bracket, a
mounting bracket and bolts. MST200 can be mounted on a pole or wall. (Pole diameter must be 40 to 60
MST200 Installation Guide
mm at the position where the MST200 will be mounted.)
Note

If using M8 x150 long bolts (not provided in the box shipped with MST200), the MST200 can be
mounted on a pole with 96mm diameter.
Figure 3-1 the mounting assembly
a pair of pole anchors
A positioning bracket
MST200 Installation Guide
A mounting bracket
10
Figure 3-2 Bolts
{M6 x12 bolt, flat washer, spring washer}x5
{M8 x16 bolt, flat washer, spring washer}x2
{M4 x12 bolt, external-tooth washer, OT copper
lug}x1
{M8 x110 bolt, flat washer, spring washer,
nut}x4
Step 1 Fasten the positioning bracket onto the back of the MST200 using the five M6 x 12 bolts (with flat
and spring washers). (There is screw thread in the screw hole of the mounting bracket, so nuts are
not required)
Figure 3-3
Fasten the positioning bracket onto the back of the MST200
MST200 Installation Guide
11
Step 2 Use the two M8 x 16 bolts (with flat washers and spring washers) to fasten the positioning
bracket flanges to the mounting bracket flanges.
Figure 3-4 Positioning bracket and mounting bracket bolted at flanges
MST200 Installation Guide
12

The flange bolts allow the inclination of the MST200 to be adjusted by
shifting the angle of the bracket using the fastening bolts as an axis.
Step 3 When mounting the MST200 to a pole, use the four M8 x 110 bolts (with flat washers, spring
washers and nuts) and two pole anchors to fasten the mounting bracket to the pole.
MST200 Installation Guide
13
Figure 3-5 Mounting MST200 on a pole
3.2
Grounding the MST200
The grounding must be completed before powering up the MST200.The residence of grounding wire
should be less than 5 ohm and the grounding cable’s cross-section area should be no less than 6
mm2.The grounding hole is at the left side of the MST200.
Figure 3-6 Grounding the MST200
Step 1 Peel the cover of one end of the grounding cable (green or yellow and green grounding cable with 6
mm2 cross-section area) and place the bare grounding cable into the copper lug, and press firmly
MST200 Installation Guide
14
with the crimping pliers.
Step 2 Fasten the copper lug to the grounding hole on the MST200 with the M4 x12 bolt and external-tooth
washer.
3.3
Connecting the Ethernet cable
Step 1 Remove the protective cap on the Ethernet interface.
Step 2 Insert the Ethernet cable connector into the Ethernet interface and hand-fasten the waterproof cover.
Step 3 Water-proof the Ethernet cable connection with PVC insulation tape, adhesive insulation tape and
strap.
Figure 3-7 Connecting Ethernet cable
MST200 Installation Guide
15
Note

A waterproof Ethernet connector kit will be shipped with the MST200, including ① shielded RJ45
connector, ② gasket mat, ③waterproof Ethernet connector socket, ④ locknut, ⑤seal ring,
⑥sealing nut, as shown in the figure below:
MST200 Installation Guide
16
4 Note

To log onto the MST200 via Console port, use the setting as shown in table below:
Baud Rate
115200
Data Bits
Parity
None
Stop Bits
Flow Control
None
Default Username and Password
root : public
MST200 Installation Guide
17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Author                          : wakeyouw
Create Date                     : 2012:03:16 10:33:47+08:00
Modify Date                     : 2012:03:16 10:33:47+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - MST200 Installation Guide PD60E-001
Creator                         : wakeyouw
Document ID                     : uuid:66375184-e961-429b-a647-e6e7d4dbb435
Instance ID                     : uuid:2b9fdd57-89d0-427e-803e-89b4d70d3bfa
Page Count                      : 18
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q9DMST200

Navigation menu