Hewlett Packard Enterprise WL548A1 3Com AirProtect Sensor 5750 User Manual
Hewlett-Packard Company 3Com AirProtect Sensor 5750
User Manual
Quick Installation Guide 3Com® AirProtect Sensor 5750 3CRWX5750GS / Model WL-548A The 3Com® AirProtect Sensor 5750 provides dual-radio IEEE 802.11a and 802.11b/g wireless intrusion prevention (WIP) capability for your network. The sensor is designed for use with a 3Com AirProtect WIPS Engine 6100, and requires hardware installation only. You must have a 3Com AirProtect Engine 6100 installed on your network to operate the sensor. Power is supplied using Power Over Ethernet (PoE). The following 3Com PoE devices, or any thirdparty 802.3af compliant PoE solution, may be used to supply power to the sensor: • 3Com WX1200 • 3Com WXR100 • 3Com PoE Injector • Any 3Com 802.3af compliant PoE Switch About This Guide This Quick Installation Guide describes the basic setup of the sensor. It covers the following topics: • • • • • • • • • • 3Com AirProtect Sensor 5750 Features Observing Safety Precautions Step 1: Unpacking the Sensor Step 2: Preparing for Installation Step 3: Attaching the Antennas Step 4: Mounting the Sensor Step 5: Connecting Power and the Network Step 6: Checking the LED Indicators Troubleshooting Regulatory Information 3Com AirProtect Sensor 5750 Features Feature Description Antenna Connectors Two RSMA type antenna connectors allow you to connect antennas that operate in 2.4 GHz and 5.0 GHz bands. LEDs The LEDs indicate power and activity. See “Checking the LED Indicators” on page 8 for details. Ethernet Port The Ethernet port provides a 10/100BASE-TX Ethernet connection to a 3Com Wireless LAN switch. The connection can be direct to a 3Com switch or indirect through an intermediate Layer 2 or Layer 3 network. Use a standard Category 5 cable with straight-through signaling and standard RJ-45 connectors to connect the sensor to the switch on the network. Serial Port The serial port is not used for basic sensor operations. Reset Button To restore factory settings, press the reset button during power-up by inserting a pointed object into the reset hole on the back of the sensor and holding for at least 20 seconds. Kensington lock connector Detachable rear-panel cover Mounting Bracket The mounting bracket comes attached to the sensor and allows the unit to be mounted on a wall or ceiling. Observing Safety Precautions This equipment must be installed in compliance with local and national building codes, regulatory restrictions, and FCC rules. For the safety of people and equipment, only professional network personnel should install the sensor. WARNING: Warnings contain directions that you must follow for your personal safety. Follow all directions carefully. You must read the following safety information carefully before you install or remove the unit. WARNING: Exceptional care must be taken during installation and removal of the unit. WARNING: The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet. WARNING: This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 950 / IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions. WARNING: There are no user-replaceable fuses or user-serviceable parts inside the unit. If you have a physical problem with the unit that cannot be solved with problem solving actions in this guide, contact your supplier. WARNING: Disconnect the power adapter before moving the unit. WARNING: RJ-45 ports. These are shielded RJ-45 data sockets. They cannot be used as standard traditional telephone sockets, or to connect the unit to a traditional PBX or public telephone network. Only connect RJ-45 data connectors, network telephony systems, or network telephones to these sockets. Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets. WARNING: To comply with FCC radio frequency (RF) exposure limits, a minimum body-to-antenna distance of 20 cm (8 in.) must be maintained when the sensor is operational. Approved Channels Use of this product is only authorized for the channels approved by each country. For proper installation, select your country from the country selection list. To conform to FCC and other country restrictions your product may be limited in the channels that are available. Informacje na temat bezpieczeñstwa Urządzenie musi być zamontowane zgodnie z lokalnymi i krajowymi normami, ustawami i przepisami. W celu zagwarantowania bezpieczeństwa osób i urządzeń, instalację Punktu dostępowęgo może przeprowadzać wyłącznie wyszkolony fachowiec ds. sieci. OSTRZEŻENIE: Ostrzeżenia zawierają wskazówki, których należy przestrzegać w celu zagwarantowania bezpieczeństwa osobistego. Do tych zaleceń należy stosować się dokładnie. Przed przystąpieniem do montażu lub demontażu urządzenia należy dokładnie przeczytać następujące informacje dotyczące bezpieczeństwa. OSTRZEŻENIE: Podczas montażu lub demontażu urządzenia należy pracować z wyjątkową uwagą. OSTRZEŻENIE: Gniazdo sieciowe powinno znajdować się w pobliżu urządzenia i być łatwo dostępne. Z urządzenia można odciąć zasilanie wyłącznie poprzez wyjęcie kabla zasilającego z gniazda. OSTRZEŻENIE: Urządzenie działa w warunkach SELV (obwód bezpiecznego niskiego napięcia) zgodnie z normą IEC 950 / IEC 60950. Warunki te są jednak zagwarantowane wyłącznie wtedy, gdy sprzęt, do którego podłączone jest urządzenie, również pracuje w obwodzie SELV. OSTRZEŻENIE: Wewnątrz urządzenia nie znajdują się wymienne bezpieczniki lub części, które mogłyby być oddane do naprawy. W przypadku wystąpienia problemu, którego nie można rozwiązać za pomocą wskazówek podanych w tej instrukcji obsługi, prosimy o kontakt z dostawcą produktu. OSTRZEŻENIE: Przed przeniesieniem urządzenia należy odłączyć zasilacz. OSTRZEŻENIE: Porty RJ-45. Są to ekranowane gniazda RJ-45 do danych. Nie są przeznaczone do użycia jako standardowe gniazda telefoniczne lub do podłączenia urządzenia do PBX lub publicznej sieci telefonicznej. Do tych gniazd wolno podłączać wyłącznie wtyki RJ-45 danych, systemów telefonii sieciowej lub telefonów sieciowych. Do tych gniazd można podłączać kable danych ekranowane lub nieekranowane z ekranowanymi lub nieekranowanymi wtykami. OSTRZEŻENIE: W związku w ograniczeniami częstotliwości radiowej (RF), minimalna odległość między ciałem a anteną wynosząca 20 cm (8 cali) musi być zachowana w przypadku stosowania Punkt dostępowy. 1. Unpacking the Sensor Make sure that you have the following items, which are included in the package: • One 3Com AirProtect Sensor 5750 • Two external 2.4 GHz and 5 GHz dual- • • • • band antennas • • • • Rear panel cover Category 5 Ethernet cable This Quick Installation Guide Warranty flyers (English and Spanish) Regulatory sticker sheet Mounting bracket Wall-mounting hardware Four adhesive rubber feet (used for a flat-surface installation) 2. Preparing for Installation It is advisable to connect the power (if using an external PoE supply) and check the Ethernet cables and LEDs before installing the sensor in a hard-to-reach location. Additionally, observe the following items before mounting or connecting the sensor: Installation Item Description Switch port The sensor must connected to the same wired network as the AirProtect Engine 6100. 3Com recommends that you install and configure the 3Com AirProtect Engine 6100 before installing the sensor. Cabling Make sure that standard Category 5 cable with straight-through signaling is installed at the site before you install the sensor. Make sure that the cable is highly flexible and that there is no extra covering on the RJ-45 connector that could prevent the cable from being routed through the mounting bracket. Power Requirements Power must be supplied from an 802.3af Power Over Ethernet (PoE)compliant device. If using an external PoE power injector, make sure the power outlet is accessible. The power supply plug is the only means of disconnecting the sensor from power. MAC Address Record the sensor MAC address in a safe place before the sensor is installed in a hard-to-reach location. The MAC address is printed on the back of the sensor. 3. Attaching the Antennas Carefully unpack the standard detachable antennas. Screw the antennas on to the antenna connectors on the sensor and hand-tighten them. After network startup, you may need to adjust the antennas to fine-tune coverage in your area. For best results, adjust the antennas so that they are perpendicular with the floor and ceiling. CAUTION: Do not handle the antenna tips, especially after they are connected to the sensor. This could lead to electrostatic discharge (ESD), which could damage the equipment. 4. Mounting the Sensor The sensor can be mounted on the following types of surfaces: • Wall, ceiling, or electrical box (NEMA enclosure) • Tabletop Wall, Ceiling, or Electrical Box Mounting Use the included mounting bracket to install the sensor on a wall, ceiling, or electrical box. To wall-mount the sensor: 1 Route Ethernet cable through the opening in the cradle. 2 Screw the mounting bracket to a wall, ceiling, or electrical box (NEMA enclosure): • If mounting to a solid surface wall or ceiling, use the two sheet metal screws. • If mounting to drywall, use the two sheet metal screws and two wall anchors. • If mounting to an electrical box (NEMA enclosure), use the two threaded screws. The figures below show a cable being routed through the large opening in the cradle and then the cradle being mounted to a wall. Routing a cable Wall-mounting the cradle 3 Connect the Ethernet cable (for power and network connection) to the port on the rear of the sensor. 4 Twist the sensor onto the mounting bracket. Tabletop Mounting To install the sensor on a flat surface such as a table or desktop: 1 Remove the backing from the four rubber feet and attach them on the bottom of the sensor. 2 Place the sensor on the table. 3 Connect the Ethernet cable (for power and network connection) to the port on the rear of the sensor. 5. Connecting Power and the Network The sensor connects to your network through its Ethernet port. This is also how the unit receives power. The sensor can be powered by the following methods: • By Power Over Ethernet (PoE) supplied through the LAN by a 802.3af PoE compliant device such as a switch or hub. • By PoE supplied by an optional 3Com PoE injector (not included). 3Com PoE injectors include the 3CNJPSE and 3CNJPSE24 midspan supplies. Power Over Ethernet (PoE) from the LAN To power the sensor using PoE provided by a switch or other 802.3af compliant device, simply plug the network cable from the device into the sensor’s Ethernet port. PoE Switch/Hub Sensor Power Over Ethernet from a PoE Injector To power the sensor using a 3Com PoE Injector (available separately), do the following: 1 Connect the LAN cable from the switch or hub to the Hub/Switch port on the 3Com PoE Injector (available separately). 2 Next connect a LAN cable from the Ethernet port on the sensor to the other port on the PoE injector. 3 Plug the PoE Injector into a properly grounded electric outlet. To Sensor To Switch/Hub ITCH CESS TO AC POINT B/SW TO HU PoE Injector A Wireless 3CRWX120695 Sensor LAN Switch WX1200 Switch/Hub (non-PoE) 6. Checking the LED Indicators When the sensor is connected to power, LEDs indicate activity as follows: LED Color Power Steady green LAN Power LAN 11a Indicates Power on, system OK. Amber Indicates an error, check other lit LEDs (see below). Off Power off, or system is booting. Steady green Indicates Ethernet connection to the AirProtect Engine is OK. Fast flash No IP address received from DHCP. 11b/g 11a Slow flash The sensor is unable to connect to AirProtect Enterprise Engine. Steady green 802.11a status is OK. Fast flash The sensor is performing 802.11a troubleshooting. 11b/g Slow flash The sensor is performing 802.11a intrusion protection. Steady green 802.11b/g status is OK. Fast flash The sensor is performing 802.11b/g troubleshooting. Slow flash Error conditions The sensor is performing 802.11b/g intrusion protection. Power = Amber LAN = Green The sensor cannot get an Ethernet link. Power = Amber 11a = Green There is an error on the 802.11a/b/g interfaces. Power = Amber 11b/g = Green There is a sensor software error. Troubleshooting Refer to the 3Com AirProtect Engine 6100 Configuration Guide for more details on the product. Or visit www.3Com.com. REGULATORY INFORMATION The 3Com AirProtect Sensor 5750, Model WL-548A (3CRWX5750GS) must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. This product contains encryption. It is unlawful to export out of the U.S. without obtaining a U.S. Export License. This product does not contain any user serviceable components. Any unauthorized product changes or modifications will invalidate 3Com’s warranty and all applicable regulatory certifications and approvals. This product must be installed by a professional technician/installer. Only antennas specified for your region by 3Com can be used with this product. The use of external amplifiers or non-3Com antennas may invalidate regulatory certifications and approvals. This product can only be used with the supplied antennas. CAUTION: EXPOSURE TO RADIO FREQUENCY RADIATION This device generates and radiates radio-frequency energy. In order to comply with FCC radio-frequency exposure guidelines for an uncontrolled environment, this equipment must be installed and operated while maintaining a minimum body to antenna distance of 20 cm (approximately 8 in.). The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb. This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This product must maintain a minimum body to antenna distance of 20 cm. Under these conditions this product will meet the Basic Restriction limits of 1999/519/EC [Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)]. US — RADIO FREQUENCY REQUIREMENTS This device must not be co-located or operated in conjunction with any other antenna or transmitter. This device is for indoor use only when using channels 36, 40, 44 or 48 in the 5.15 to 5.25 GHz frequency range. High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with and/or damage this device. FCC NOTICE To comply with FCC Part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden in accordance with FCC rules CFR47 Part 15.204. USA—FEDERAL COMMUNICATIONS COMMISSION (FCC) EMC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The user may find the following booklet prepared by the Federal Communications Commission helpful: The Interference Handbook. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402. Stock No. 004-000-0034504. 3Com is not responsible for any radio or television interference caused by unauthorized modification of the devices included with this 3Com AirProtect Sensor 5750, Model WL-548A (3CRWX5750GS), or the substitution or attachment of connecting cables and equipment other than specified by 3Com. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. Changes or modifications not expressly approved by 3Com could void the user’s authority to operate this equipment. INDUSTRY CANADA —DRF COMPLIANCE US MANUFACTURER ’S FCC ECLARATION OF CONFORMITY 3Com Corporation This device complies with RSS 210 of Industry Canada. 350 Drive TheCampus term “IC” before the equipment certification number only signifies that the Industry Canada technical Marlborough, 01752-3064, USA specificationsMA were met. (508) 323-5000 To reduce potential radio interference to other users, the antenna type and its gain should be so chosen Date: 1 May 2007 isotropically radiated power (EIRP) is not more than that required for successful that the equivalent communication. To prevent radio interference to the licensed service, this device is intended to be Declares that the Product: operated indoors away from windows to provide maximum shielding. Equipment (or its transmit Brand Name: 3Comand Corporation antenna) that isWL-548A installed outdoors is subject to licensing.Pour empecher que cet appareil cause du Model Number: brouillage Type: au service faisant l'objet d'une licence, il doit etre utilize a l'interieur et devrait etre place loin des Equipment AirProtect Sensor 5750 fenetres afin de Fournier un ecram de blindage maximal. Si le matriel (ou son antenne d'emission) est Complies Part 15 of the faire FCC rules. Operation is subject to power the following conditions:as(1)primary this device mayofnot installe awith l'exterieur, il doit l'objet d'une licence.High radars two are allocated users harmful interference, (2)tothis device must accept any interference received, including interference thatand/ may cause the 5.25 to 5.35 GHz andand 5.65 5.85 GHz bands. These radar stations can cause interference with cause undesired or damage thisoperation. device.This device must not be co-located or operated in conjunction with any other antenna or transmitter.The band3Com 5150-5250 MHzSensor is only5750 for indoor usage to reduce the potential for AirProtect harmful interference to co-channel mobile satellite systems.This device must not be co-located or Model WL-548A operated in conjunction with any other antenna or transmitter. INDUSTRY CANADA — RF COMPLIANCE This device complies with RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit pas produire de brouillage et (2) l’utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. The term “IC” before the equipment certification number only signifies that the Industry Canada technical specifications were met. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing. Pour empecher que cet appareil cause du brouillage au service faisant l'objet d'une licence, il doit etre utilize a l'interieur et devrait etre place loin des fenetres afin de Fournier un ecram de blindage maximal. Si le matriel (ou son antenne d'emission) est installe a l'exterieur, il doit faire l'objet d'une licence. High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with and/or damage this device. This device must not be co-located or operated in conjunction with any other antenna or transmitter. The band 5150-5250 MHz is only for indoor usage to reduce the potential for harmful interference to cochannel mobile satellite systems. This device must not be co-located or operated in conjunction with any other antenna or transmitter. 10 INDUSTRY CANADA - EMISSIONS COMPLIANCE STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Avis de Conformité à la Réglementation d'Industrie Canada Cet appareil numérique de la classe B est conform à la norme NMB-003 du Canada. SAFETY COMPLIANCE NOTICE This device has been tested and certified according to the following safety standards and is intended for use only in Information Technology Equipment which has been tested to these or other equivalent standards: • UL Standard 60950-1 • CAN/CSA C22.2 No. 60950-1 • IEC 60950-1 • EN 60950-1 EU COMPLIANCE This equipment may be operated in AT BE CY CZ DK EE FI DE GR HU IE IT LV LT FR LU MT NL PL PT SK SI ES SE GB IS LI NO CH BG RO TR Intended use: IEEE 802.11a/b/g radio LAN device NOTE: To ensure product operation is in compliance with local regulations, select the country in which the product is installed. Česky [Czech] 3Com Coporation tímto prohlašuje, že tento RLAN device je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk [Danish] Undertegnede 3Com Corporation erklærer herved, at følgende udstyr RLAN device overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch [German] Hiermit erklärt 3Com Corporation, dass sich das Gerät RLAN device in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian] Käesolevaga kinnitab 3Com Corporation seadme RLAN device vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English Hereby, 3Com Corporation, declares that this RLAN device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español [Spanish] Por medio de la presente 3Com Corporation declara que el RLAN device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ 3Com Corporation ΔΗΛΩΝΕΙ ΟΤΙ RLAN device ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. Français [French] Par la présente 3Com Corporation déclare que l'appareil RLAN device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Italiano [Italian] Con la presente 3Com Corporation dichiara che questo RLAN device è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. 11 Latviski [Latvian] Ar šo 3Com Corporation deklarē, ka RLAN device atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių [Lithuanian] Šiuo 3Com Corporation deklaruoja, kad šis RLAN device atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands [Dutch] Hierbij verklaart 3Com Corporation dat het toestel RLAN device in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti [Maltese] Hawnhekk, 3Com Corporation, jiddikjara li dan RLAN device jikkonforma malhtigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Magyar [Hungarian] Alulírott, 3Com Corporation nyilatkozom, hogy a RLAN device megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Polski [Polish] Niniejszym 3Com Corporation oświadcza, że RLAN device jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese] 3Com Corporation declara que este RLAN device está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko [Slovenian] 3Com Corporation izjavlja, da je ta RLAN device v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky [Slovak] 3Com Corporation týmto vyhlasuje, že RLAN device spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish] 3Com Corporation vakuuttaa täten että RLAN device tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska [Swedish] Härmed intygar 3Com Corporation att denna RLAN device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Íslenska [Icelandic] Hér með lýsir 3Com Corporation yfir því að RLAN device er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC. Norsk [Norwegian] 3Com Corporation erklærer herved at utstyret RLAN device er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF. A copy of the signed Declaration of Conformity can be downloaded from the Product Support web page for the 3Com 3Com AirProtect Sensor 5750, Model WL-548A (3CRWX5750GS) at http://www.3Com.com. Also available at http://support.3com.com/doc/WL-548A_EU_DOC.pdf EU - RESTRICTIONS FOR USE IN THE 2.4 GHZ BAND This device may be operated indoors or outdoors in all countries of the European Community using the 2.4 GHz band: Channels 1–13, except where noted below. • In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors. • In Belgium outdoor operation is only permitted using the 2.46 – 2.4835 GHz band: Channel 13. • In France outdoor operation is only permitted using the 2.4 – 2.454 GHz band: Channels 1 – 7. EU - RESTRICTIONS FOR USE IN THE 5 GHZ BAND Allowed Frequency Bands Allowed Channel Numbers Countries 5.15–5.35 & 5.470–5.725 GHz 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140 Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, U.K. 12 • This device may be not be operated outdoors when using the bands 5150–5350 MHz (Channels 36, 40, 44, 48, 52, 56, 50, 64). • In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors. • To remain in conformance with European spectrum usage laws for Wireless LAN operation, the above 5 GHz channel limitations apply. The user should check the current channel of operation. If operation is occurring outside of the allowable frequencies as listed above, the user must cease operating the Access Point at that location and correct the configuration of the channels used before resuming operation. • The 5 GHz Turbo mode feature is not allowed for operation in any European Community country. • This device must be used with the radar detection feature required for European Community operation in the 5 GHz bands. This device will avoid operating on a channel occupied by any radar system in the area. The presence of nearby radar operation may result in temporary interruption in communications of this device. The Access Point's radar detection feature will automatically restart operation on a channel free of radar. You may consult with the local technical support staff responsible for the wireless network to ensure the Access Point device(s) are properly configured for European Community operation. BRAZIL RF COMPLIANCE Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. Opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Para maiores informações, consulte o site da ANATEL - www.anatel.gov.br KOREA RF COMPLIANCE This device may cause radio interference during its operation. Therefore service in relation to human life security is not available. TAIWAN RF COMPLIANCE 經型式認證合格之低功率射頻電機 , 非經許可 , 公司、商號或使用者均不得擅自變更頻率、加大功率或變更 原設計之特性及功能。低功率射頻電機之使用不得影響飛航安全及干擾合法通信 ; 經發現有干擾現象時 , 應 立即停用 , 並改善至無干擾時方得繼續使用。前項合法通信 , 指依電信法規定作業之無線電通信。低功率射 頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 CHINA ROHS 13 Copyright © 2007 3Com Corporation. All rights reserved. 3Com and the 3Com logo are registered trademarks of 3Com Corporation. All other company and product names may be trademarks of the respective companies with which they are associated. Part Number: 10016130 Rev. AA DRAFT 070425 Published May 2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2007:05:04 08:47:45Z Creator Tool : FrameMaker 7.2 Modify Date : 2008:05:09 15:49:52+08:00 Metadata Date : 2008:05:09 15:49:52+08:00 Format : application/pdf Creator : 3Com Title : 3Com® AirProtect Sensor 5750 Quick Installation Guide Description : 3CRWX5750GS / Model WL-548A Document ID : uuid:0b1443d7-1687-4049-9257-867eafe5ecc5 Instance ID : uuid:eee0d500-11a5-4b41-bad1-3bd5a3411bb0 Has XFA : No Page Count : 14 Subject : 3CRWX5750GS / Model WL-548A Author : 3ComEXIF Metadata provided by EXIF.tools