Hitachi Managed Services Business Division PCKCB100 USB Finger Vein Biometric Authentication Unit User Manual HITACHI

Hitachi, Ltd.,Information & Telecommunication Systems Company USB Finger Vein Biometric Authentication Unit HITACHI

Users manual

Download: Hitachi Managed Services Business Division PCKCB100 USB Finger Vein Biometric Authentication Unit User Manual HITACHI
Mirror Download [FCC.gov]Hitachi Managed Services Business Division PCKCB100 USB Finger Vein Biometric Authentication Unit User Manual HITACHI
Document ID1993009
Application IDNTJTiveXjKmrGuoncI4j0A==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize53.58kB (669721 bits)
Date Submitted2013-06-18 00:00:00
Date Available2013-12-15 00:00:00
Creation Date2013-03-21 19:05:19
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2013-03-21 19:08:16
Document TitleHITACHI
Document CreatorMicrosoft® Office Word 2007
Document Author: Hitachi, Ltd

Hitachi USB Finger Vein Biometric Authentication Unit
PC-KCB100
User Guide
Read all guidelines in this document carefully before using this product.
This document should be kept for the future reference.
Important Notices
 Quoting or partial / total reprinting of the contents of this document without license is
prohibited.
 The contents of this document are subject to change without notice.
 In the case of any errors, inaccuracies or omissions in the contents of this document, please
contact with your distributor.
 Hitachi, Ltd. permits the acquisition and use of the product according to the conditions
indicated in this document.
 According to the statements contained in previous paragraphs, Hitachi, Ltd. will not assume
any liability or obligation for damages of any kind arising from the use of this product.
Consequently, do not use the product unless you fully understand its operation.
Product Reliability
 The product you have purchased has been designed and manufactured for general office use.
Avoid its use for applications that require extremely high reliability or in cases where lives
or property may be at stake, for example the control of chemical plants, medical devices,
urgent communications etc. Hitachi, Ltd. assumes no liability for any such uses and for any
derived circumstances that may lead to accidents if used inappropriately .
 Hitachi, Ltd. do not guarantee the correct functioning of this product if it is used
simultaneously with other identification devices.
Regulations and Measures
 ICES-003 Statements
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
 Federal Communications Commission (FCC) Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:(1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
USB cable in the package must be used for connection to host computer in order to meet
FCC emission limits.
1 / 13
Note: This equipment has been tested and found to comply with the limits for a class B
digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. There is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
 Consult the dealer or an experienced radio/TV technician for help.
 Exports Regulations
Before exporting the product, verify legal requirements in each country in addition to U.S.
regulations for export control, and make all necessary arrangements accordingly. The above
applies to attachments and software surrounding the device as well. Contact your distributor
should you have any concerns.
Disposal
 When discarding this product, follow all regional and local laws. Also consult regulations
regarding the material of each component.
Hazardous substance table for China
有毒有害物质或者元素
部件名称
印刷线路板
机箱
连接线缆
光学部件
USB 线缆
铅
(Pb)
×
○
○
○
○
水银
(Hg)
○
○
○
○
○
镉
(Cd)
○
○
○
○
○
六价铬
(Cr(VI))
○
○
○
○
○
多溴联苯
(PBB)
○
○
○
○
○
多溴二苯醚
(PBDE)
○
○
○
○
○
○:表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T26572-2011 规定的限量要求以下.
×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572-2011 规定的限量要求.
备注:以上部件中,部分含有有毒有害物质超过是由于目前行业技术水平所限,暂时无法实现替代或减量化。
2 / 13
Notes
Attention: If the device is not properly used, device failure may occur.
Important: If the device is not properly used, certain functions may not respond properly.
Safety Guidance



Do not use this product near wet places such as humidifiers, washing machines,
cooking places, washbasins, baths and the like. This may cause damage to the
product.
Do not use damaged or badly bent USB cables. If the cable is damaged, this may
cause interruptions or malfunction.
Do not dismantle or modify this device. It may lead to damage and malfunction.
3 / 13
1. Introduction
1. Introduction
Hitachi gratefully acknowledges your purchase of the Hitachi USB Finger Vein Biometric
Authentication Unit (hereafter referred to as “FV Unit”). The objective of this document is to
provide a basic understanding of how to handle and use the FV Unit.
1.1 Product characteristics
The FV Unit is a biometric authentication device that performs individual authentication by
capturing finger vein patterns.
1.2 What’s in the box
Your FV Unit package includes:
FV Unit
····························· 1 unit
USB Cable (1.8m/5.9ft) ······· 1 piece
1.3 FV Unit components
Overhead view
Indicator LED
Scanning area (The area capturing the finger vein pattern)
SIM card slot
Anti-theft lock hole for a security cable
Back view
USB connector (Mini-B Type)
4 / 13
1.4 LED color and FV Unit status
The indicator LED shows the status of the of the FV Unit. Depending on its color and blinking
state, please take an appropriate action.
LED status
FV Unit status
Action
Orange
FV Unit is connected to the PC and
SIM card is not inserted or recognized.
Insert SIM card to the FV Unit.
Orange blink
FV Unit is connected to the PC and
SIM card being is accessed.
Green
Green blink
Red
Off
FV Unit is connected to the PC and
SIM card is recognized.
FV Unit is connected to the PC and
is requesting the capturing of finger
vein.
FV Unit is connected to the PC and
a permanent error occurred.
FV Unit is disconnected from the PC
or PC does not recognize the unit.
Wait until the LED status
becomes Green.
Do not disconnect the FV Unit
or remove the SIM card.
FV Unit is to ready for use
Place your finger on the
scanning area of the FV Unit.
Disconnect the FV Unit from PC
and connect again.
Connect the FV Unit to the PC.
2. Installation of the FV Unit
2. Installation of the FV Unit
2.1 Place the FV Unit
Install the FV Unit on a horizontal and stable place. No light through a window or from lamps
should enter the scanning area of the FV Unit.
It is recommended that you use the FV Unit in the 300-1000 lx luminance environment, which
is equivalent to brightness suitable for reading a newspaper.
Important

Do not use the FV Unit in places where the FV Unit is exposed to the strong light
such as outdoors, near windows, near a light source. It may lead to an
authentication failure.
5 / 13
2.2 Connect the USB cable
Connect the USB Mini-B plug of the USB cable to the USB Mini-B connector of the FV Unit.
USB Mini-B connector
USB Mini-B plug
FV Unit
USB cable
Connect the plug A of the USB cable to the USB port of your PC.
Attention

Connect the USB plug and the USB connector securely. Hold the plug end when
connecting or disconnecting the USB cable to prevent the connectors from
breaking down.
Important





When connecting the USB cable via a USB hub, check the supply current. The FV
Unit may malfunction with insufficient power supply.
Do not use a USB 1.1 hub for a USB 2.0 PC port, which may cause the FV Unit to
malfunction.
FV Unit may hold some heat due to the use of infra-red rays inside, but this will
not cause malfunctions.
Do not connect more than two FV Units simultaneously to one PC. If multiple FV
Units are connected, they will not work properly.
After connecting the FV Unit to your PC, wait for at least 5 seconds before
performing any operation.
6 / 13
2.3 Check the FV Unit is recognized
After connecting the FV Unit to your PC, check that the FV Unit is recognized correctly by the
PC. Note that Windows uses the Human Interface Device driver to access the FV Unit, so you
do not need to install a specific device driver for the FV Unit.
Confirm that the FV Unit is displayed in the Device Manager as a Human Interface Device.
7 / 13
3. How to use the FV Unit
3. How to use the FV Unit
3.1 How to insert / remove the SIM card
Disconnect the USB cable before you insert or remove the SIM card.
- Insertion
Push the SIM card
softly until it is
latched in the slot.
FV Unit bottom view
FV Unit
-Removal
Push the SIM card
softly further into the
slot and release it.
After the card leaves
the slot, pull it out.
SIM
card
SIM card
slot
Important




Disconnect USB cable before you insert or remove the SIM card.
Check the direction of the SIM card before you insert it to the FV Unit.
If you insert it in the wrong direction, the FV Unit and the SIM card can be
damaged and malfunction.
Do not push the SIM card except by fingers.
The SIM card is a very small material. Be careful in its handling.
Especially, keep it away from young children in order to avoid accidental
ingestions.
8 / 13
3.2 How to perform a finger vein authentication
Place your finger on the scanning area of the FV Unit.
Place your fingertip on the groove of the back finger rest.
Place the underside of your finger gently on the front finger rest as indicated by the red circle in
the illustration below.
Fingertip
Important




Improper positioning of the finger may lead to an authentication failure. See the
Enrollment and Authentication Guide for details of the proper finger placement.
Finger vein authentication and enrollment may fail in the following cases:
 narrow fingers - finger width under 10 mm/0.4 inch
 wide fingers - finger width over 25 mm/1 inch
 short fingers - finger cannot reach the back finger rest
Do not place any non-finger objects on the scanning area of the FV Unit.
Do not disconnect the USB cable or the FV Unit from the PC.
9 / 13
4. FV Unit maintenance
4. FV Unit maintenance
Attention



Disconnect the USB cable before the maintenance of your FV Unit. Keeping the
cable connected during maintenance may cause failures.
Take caution so that the FV Unit is not exposed to any liquid or humidity as it may
cause malfunctioning.
Do not clean the device with organic solvents such as gasoline or alcohol.
4.1 Cleaning external parts
Periodic maintenance of the external parts of the FV Unit is recommended. About once a
month or whenever required according the condition of the FV Unit, clean the external parts by
rubbing it with a soft piece of cloth. If a dirt remains, use a mild detergent and wipe it off with a
damp cloth.
4.2 Cleaning scanning area
Maintenance of the scanning area is recommended about once a month or whenever it is dirty
with fingerprints and others.
1. Push sides and raise upwards to remove the finger rest (a black part) of the FV Unit.
2. Clean the scanning area using a soft piece of cloth. If you find large dusts, remove
them before cleaning.
Scanning area
3. After the cleaning is complete, place the finger rest back into its original position.
10 / 13
5. Hardware specifications
5. Hardware specifications
Name
USB Finger Vein Biometric Authentication Unit
Model
PC-KCB100
Applicable finger width *1
Wider than 10 mm/0.4 inch and narrower than 25 mm/1 inch
Interface
USB 2.0 *2 *3 *4
Approx.
59mm/2.3inch(W) x 82mm/3.2inch(D)x 74mm/2.9inch(H)
(USB cable not included)
Approx.
102g/3.4oz (USB cable not included)
Dimensions
Weight
Maximum Current
Consumption
Operating
Environment
temperature
Conditions
Operating
(Operation)
Humidity
Storage
Environment Temperature
Conditions
Storage
(Storage)
Humidity
SIM card
DC 5V 500 mA (Bus powered)
5 to 35 degrees C (41 to 95 degrees F)
20 to 80% Rh (Do not allow condensation)
-10 to 60 degrees C (14 to 140 degrees F)
20 to 80% Rh (Do not allow condensation)
ISO/IEC 7810 ID-000 sized
*1: If the finger positioning is incorrect, authentication may fail even with the applicable finger
width.
*2: It is recommended to connect the FV Unit directly to the USB port of your PC. If you need
to connect the FV Unit via a USB hub, use a self-powered hub.
*3:When you reconnect the FV Unit to your PC after a disconnection, use the same USB port to
which the FV Unit was connected.
*4:When FV unit is connected to the USB 3.0 port, FV unit is recognized as a USB 2.0 device.
11 / 13
6. Troubleshooting
6. Troubleshooting
This chapter presents methods for solving problems with the FV Unit.
 The USB cable is connected to the FV Unit, but the LED does not turn on in
green
The supported SIM card is not inserted.
→ Insert the supported SIM card. You need to insert a SIM card in which Hitachi
Finger Vein Biometric PKI Card Application (C-N1719-20) is installed.
The device driver is not appropriately configured.
→See 2.3 Check the FV Unit is recognized and confirm that the device driver is
properly configured on the PC.
The USB port of your PC is malfunctioning.
→ Restart your PC.
The FV Unit is damaged.
→ Please contact your retailer.
 Authentication fails
Your finger position is not stable during the capture process
→ Place your finger properly on the scanning area during the capture process. Do not
move your finger until the capture process is completed.
Your finger is not properly placed.
→ Place your finger properly into the scanning area as shown in the Authentication and
Registration Guide.
Your finger is wounded, excessively dry or dirty
→ Wash or clean your finger, then perform authentication again. When your finger is
wounded, excessively dry or dirty, a quality finger vein image may not obtained and
it may result in authentication failure.
Your current finger condition differs from that at enrollment.
→ Enroll your finger again.
Your finger width is over 25 mm/1 inch or below 10 mm/0.4 inch
→ Enroll other finger. When a finger is too wide or too narrow, a quality finger vein
image is not obtained and it may result in authentication failure.
 Authentication does not start
The FV Unit is not ready to start the authentication process.
→ When the FV Unit is connected to the PC and SIM card is inserted properly, its LED
light is on in green. However, when connecting the FV Unit or inserting the SIM
card, you need to wait for at least 5 seconds until the LED status changes from blank
or orange blink to green, before performing an authentication process.
12 / 13
Copyright
© Hitachi, Ltd. 2013. All rights reserved.
The software and the manual can be used and managed under the responsibility of the
administrator registered in the relevant document of FV Unit.
Without the express consent of Hitachi, Ltd., the following is prohibited:
1. Reproduction, photocopying or transference of this user's guide contents, either
partially or in its entirety, as well as the transfer of the registration information
contained in the Unit memory.
2. Translation of this user's guide to any computer languages or any other language.
The use of any electronic, mechanical, magnetic, optic or similar procedures for performing the
above actions laid down in points 1 and 2 is also prohibited.
All other logos, product names, brand names and company names mentioned herein are either
trademarks or registered trademarks of their respective owners.
Hitachi USB Finger Vein Authentication Unit PC-KCB100
User Guide
1st Edition May 2013
Reproduction is forbidden without consent.
© Hitachi, Ltd. 2013. All rights reserved.
13 / 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Modify, Copy, Annotate, Fill forms, Extract, Print high-res
Page Count                      : 13
Language                        : ja-JP
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.0-jc006 DEBUG-1.0, 2010 Feb 05 19:01:09-PST
Producer                        : Microsoft® Office Word 2007
Title                           : HITACHI
Creator                         : Hitachi, Ltd
Format                          : application/pdf
Creator Tool                    : Microsoft® Office Word 2007
Create Date                     : 2013:03:21 19:05:19+09:00
Modify Date                     : 2013:03:21 19:08:16+09:00
Metadata Date                   : 2013:03:21 19:08:16+09:00
Document ID                     : uuid:E6C0D369-EE59-411C-9D9C-A2783B23B20A
Instance ID                     : uuid:39619c12-3992-2cc9-59a9-4d1377bd9c44
Part                            : 1
Conformance                     : B
Author                          : Hitachi, Ltd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZQDPCKCB100

Navigation menu