Hitec RCD SRX12 2.4GHz Aircraft Receiver User Manual
Hitec RCD Inc. 2.4GHz Aircraft Receiver
User Manual
Receiver Model Size Weight SRX12 46.5 x 35.5 x 15.7mm 21g MRX3 38.8 x 20.2 x 11.5mm 6.5g Help is available from the Hitec office through phone support and e-mail inquiries. Our US office is generally open Monday thru Friday, 8:00AM to 4:30PM PST. These hours and days may vary by season. Every attempt is made to answer every incoming service call. Should you get voice mail, leave your name and number and a staff member will return your call. Operation Voltage : NiMH, NiCD – 4~6 cell (4.8V~7.2V) or Li-Po – 2 cell (7.4V) can be used.Up to 7.4V BEC power from ESC also can be used. SRX12 SPC port allow to use up to 70V (4.8V~70.0V). Make plans to visit the Hitec website, www.hitecrcd.com, on a regular basis. Not only is it full of specs and other informaction about the entire Hitec product line, our FAQ pages will eventually hold valuable information and program update about the OPTIMA D receiver. 1. LED Indicates the set-up process codes and current status of the receiver. (Please refer to page 2 for more detail) 2. System Power Input & Servo Signal Output Port One of the bene_ts of the extensive R/C online community is the vast wealth of archived knowledge available. Supplying power to Receiver System, Servo, Bus system and Sensor accessories from RX Battery. Hitec sponsors forums on most of the popular R/C web sites where a Hitec staff_ member or representative tries Signal output port. External Battery Voltage, SPC Input Port. to answer all manner of product related questions. Bringing together strangers with common interests is proving to be one of the greatest gifts of the internet. If PWM Output Port past history is any guide to the future, we are certain forums will be started about the Hitec 2.4 system and SRX 12 – General Servo can use in CH1~CH12 Port. several are certain to stand out as valuable archives of information MRX 3 – General Servo can use in CH1~CH3 Port Single Line( SL ) Output Port ( SRX 12, MRX 3 ) All Hitec products carry a two year from date of purchase warranty against manufactures defects. With SL function, Futaba S-Bus or PPM can be selected. Please select suitable Bus system based on your device. (Please refer to ID Link section for more detail) Our trained and professional service representative will determine if the item will be repaired or replaced. To provide all the necessary information we need to administrate your repair, visit our website at www.hitecrcd.com and download the repair form, _ll it out and send in your item for repair. Sensor Output Port *MSB* (SRX 12) Multiplex M-Link Sensor can be connected and can use in SRX 12 Receiver via MSB port Voltage Sensor (MRX 3) MRX 3 can check External Battery voltage (Main Battery) using Voltage Sensor port up to 70V ( 4.8V~70V ). Voltage can be checked by Transmitter in real time. SPC Power Input Port (SRX 12) Using SPC, SRX 12 can be operated from 4.8V to max 70V. When using SPC, separate servo power must be needed. (4.8~7.4V, 4~5cell NiMH/NiCd battery or Li-Po 2 cell Battery) 5) Blue LED in the receiver will be blinking rapidly and will be blinking slowly. Jumper 6) Please check ID Link correctly or not by moving radio stick and press ‘Finish’ in the menu to escape. The jumper is installed at the factory and is used when the receiver is powered by an electronic speed control, a commercially available B.E.C. (battery eliminator circuit), dedicated 4.8 to 6V, NiMH battery pack or a regulated Li-Po battery. The jumper is removed when the receiver is powered using the SPC feature Fail-Safe / Hold Function Mode as described. Fail-Safe Mode? If the receiver signal somehow becomes interrupted or interference occurs, the servos will move to the function properly. pre-set Fail-Safe point you previously stored in the Fail-Safe set-up. Make sure you set the Fail-Safe If Fail-Safe has not been activated, the signal will switch off after the Hold period of one second. This function properly. means that the servos become “soft” and remain in their last commanded position under no load (this may equate to full-throttle!), until a valid signal is picked up again. If Fail-Safe has not been activated, the signal will switch off after the Hold period of one second. If the receiver signal somehow becomes interrupted or interference occurs, the servos will move to the pre-set Fail-Safe point you previously stored in the Fail-Safe set-up. Make sure you set the Fail-Safe Fail-Safe / Hold ( SRX 12, MRX 3 ) In the interest of safety, we recommend that the Fail-Safe function should always be activated, and the Fail-Safe settings should be selected so as to bring the model to a non-critical situation Please refer to Fail-Safe/ Hold page for more detail In the interest of safety, we recommend that the Fail-Safe function should always be activated, and the Fail-Safe settings should be selected so as to bring the model to a non-critical situation (e.g. motor idle /electric motor OFF, control surfaces neutral, airbrakes extended, aero-tow release open, etc.). 1) Switch on the Radio Compatibility - SRX 12/ MRX 3 receivers are compatible with transmitter using Spectra G3 AFHSS 2.4Ghz system. Currently Aurora 16 and Flash 14 are using Spectra G3 AFHSS 2.4Ghz system. - Aurora 9/ 9X, Optic 5/6/6 sports, Lite 4, Flash 7/8, Eclipse 7 pro are not compatible with SRX 12, MRX 3 receiver Connection Diagram Electric powered aircraft with Electronic Speed Control Use this method on electric air plane using ESC’s providing power to the receiver and servo function. (If ESC has no BEC circuit, please use separate battery for receiver and servo) Glow, gas or electric powered aircraft using separate a receiver battery supply Follow below connection diagram when using a regulated Li-PO, Li-Fe (2cell) or 4~6cell Ni-MH, Ni-CD battery. ID Link (ID-Set up) Each radio set (using Spectra G3 system and SRX 12 or MRX 3 receiver) is already Linked from the factory. You don’t need to ID Link when you purchased a set of radio. However, If you buy additional SRX 12 or MRX 3 receiver, you have to do ID Link with new receiver and the radio. Before ID Link, please make sure all connection correctly refer to above connection diagram. How to ID Link between G3 Spectra radio and SRX 12/MRX 3 receiver 1) Turn on the Radio power 2) Select ‘Spectra’ in the system menu in the radio. (Aurora 16/Flash 14) 3) Select G3 and choose Frame Time Receiver No (S1) Bus type step by step. 4) Make sure distance between radio and receiver within 3 feet and turn on Receiver power. 2) Select ‘Fail-Safe’ from system menu in Aurora 16/Flash 14 3) Select Fail-Safe or Hold for your purpose 4) If you choose ‘Fail-Safe’, set the Fail-Safe position of servo or motor by change value in the menu or stick and then press ‘Set’ to confirm. 5) Press ‘Send’ to memorize Fail-Safe value to Receiver. (LED in the receiver will be blinking rapidly)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2016:12:29 15:42:57+09:00 Creator : Microsoft® Word 2016 Modify Date : 2016:12:29 15:42:57+09:00 Title : XMP Toolkit : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29 Metadata Date : 2016:12:29 15:42:57+09:00 Creator Tool : Microsoft® Word 2016 Format : application/pdf Document ID : uuid:201da493-ff1a-46a9-b20c-84190e5534c4 Instance ID : uuid:c40357cc-ce14-4ea6-905e-8d83f1a7c1bf Producer : Adobe Acrobat Standard DC 15.6.30244 Page Count : 3EXIF Metadata provided by EXIF.tools