Hitron TECHNOLOGIES CGNDP2 Wireless Docsis Probe User Manual

Hitron Technologies Inc. Wireless Docsis Probe Users Manual

Users Manual

Download: Hitron TECHNOLOGIES CGNDP2 Wireless Docsis Probe User Manual
Mirror Download [FCC.gov]Hitron TECHNOLOGIES CGNDP2 Wireless Docsis Probe User Manual
Document ID3215754
Application IDGPCBeyVNWX2LBJCmB9Oisw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize147.15kB (1839397 bits)
Date Submitted2016-12-02 00:00:00
Date Available2016-12-02 00:00:00
Creation Date2017-12-18 18:37:19
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-18 18:37:19
Document TitleUsers Manual
Document CreatorAdobe Acrobat 10.1.16

Q U K: K STA RT G U | D E Check the box contents
Look in the box and make sure you have the following:
\ a»
CGN-DP2 POWER ADAPTER
HITRON
DOCSIS Probe
CGN-DP2
QUICK START GUIDE
11
F-CONNECT OR
. ADAPTER QUICK START GUIDE BATTERY
hitron
Install the battery Charge the battery
STEP Use the screws to install the battery.
STEP Use the power adapter (16V) to fully charge the battery.
3 ”Charge LED: ”3
Steady Red Status
» Charge
._Battery is charging Bmmwfl
Disconnect the power adapter Turn on the unit
STEP When the battery is fully charged, you may disconnect the unit
4 from the power adapter.
Charge LED off: smms
STEP The power button is located on the bottom of the unit.
Battery-H
Battery—H/M/L:
Battery-M
Charge Battery-L
*' Battery is fully charged
A Charge Completed Bmmw+l ..
Install the app and connect the unit
STEP Install the Hitron probe app through your cable operator’s
6 internal deployment method. Once installed, open the app
and click this icon to survey available SSIDs.
Select Wi-Fi SSID
SelectWi-FiSSID CGNDP'OI E0
(9 F? mus-31:43 (Ct-DP mm
z’w: "2“ w .~ :' - .__
III 4 .
0 Spectrum
@ Channel Plan Scan
Level Monitor
w Upstream Equalization Analysis
LED Display
Green-Steady :Device is running.
off :Device is in charge or damaged.
Please check battery status.
Green-BlinkingzData transmit between cellphone and
device.
Green-Steady :Wifi connect between cellphone and
device.
off :Device damaged.
Green-BlinkingzDevice is searching for the downstream
frequency.
Green-Steady :Downstream frequency is locked.
Green-BlinkingzDevice is searching for the upstream
frequency.
Green-Steady :Upstream frequency is locked.
Connect options
, 7 Cellphone
Safety Warning
WARNING
Risk of electrical shock. Do not expose the device to water or moisture.
The device is a high-performance communications device designed for
home and office environments.
Keep the device in an environment between 0°C ~ 25°C.
The manufacturer assumes no liabilities for damage caused by any
improper use of the device.
DISCLAIMER
The manufacturer assumes no liabilities with respect to the contents of
this document. The manufacturer also reserves the right to revise this
document or update the content thereof without any obligation to notify
any person of such revisions or amendments.
Specifications subject to change without notice.
CAUTION
The cable distribution system should be grounded (earthed) in a
accordance with ANS/NFPA 70, the National Electrical Code (NEC), in
particular Section 820.93, Grounding of Outer Conductive Shield of a
Coaxial Cable.
Green-Blinking:Registration is in progress with cable
company’s head-end.
Green-Steady :Device is operational.
.................. fo..-.3[?‘?Yi.c.e.i§9ff.li'1€-.-........-..-...
Red-Blinking :Charge error.
Red-Steady :Charge in process.
off :Charge complete.
Green-Blinking:Charge in process.(with AC power)
Green-Blinking:Discharge. (without AC power)
Green-Steady :Charge complete to 100 %.
Green-Blinking:Charge in process.(with AC power)
Green-Blinking:Discharge. (without AC power)
Green-Steady :Charge complete to 66 %.
Green-Blinking:Charge in process.(with AC power)
Green-Blinking:Discharge. (without AC power)
Green-Steady :Charge complete to 33 %.
2 USB Dongle ‘
Power ' '
adapter
Computer
FCC Statement:
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one of the following measures:
0 Reorient or relocate the receiving antenna.
0 Increase the separation between the equipment and receiver.
0 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
0 Consult the dealer or an experienced radio/ TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received
, including interference that may cause undesired operation. For product available in the USA/Canada market,
only channel 1~11 can be operated. Selection of other channels is not possible.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
COPYRIGHT © 2016 HITRON TECHNOLOGIES, INC.
P/N:0440010230N0(1A)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:e8e7294d-a5f3-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:21 05:42:19Z
Create Date                     : 2017:07:21 05:42:19Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:e8e7294d-a5f3-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AHKM-CGNDP2

Navigation menu