Hohem Technology DG1 3-AXIS HANDHELD STABILIZING GIMBAL FOR DSLR User Manual
Hohem Technology Co., Ltd. 3-AXIS HANDHELD STABILIZING GIMBAL FOR DSLR Users Manual
Users Manual
DG1Quick Start Guide V1.0 Product Overview (2) Place the mounting plate which the camera is mounted on the clamping plate and tighten the screws GuideV1.0 Tilting 360° Rolling 360° Web:www.hohem-tech.com E-mail:service@hohem-tech.com Tel:0755-86573216 (Copyright: Hohem Technology Co.,Ltd) Tilt Axis Roll Axis Thumb Screw 1 L-Shape Mounting Plate Screwing clockwise to fix the mounting plate Thumb Screw 2 Button up the mounting plate and clamping plate via a Z-shape socket 3. Balancing:(1)Balancing the Tilt Axis Lens Holder Thumb Screw 3 Pan Axis Panning 360° UARTExtendedPort Signal Indicator Light Thumb Screw 5 a. Adjust tilt axis balance in horizon direction:Placethe gimbal like picture 3-1-a, hold the roll axis and keep it in horizontal steady, position the camera lens pointing forwards and loosen the lens, observe the camera status. Thumb Screw 4 USB Port 5-Way Joystick If camera lens tilts upside 1/4”Extension Screw Hole Multifunctional Button(Power On/ Off) Status Indicator Light Loosen the thumb screw 5, move the camera forwards through sliding arm to make camera balanced If camera lens tilts downside Move the camera backwards through sliding arm to make camera lens balanced. Accessories List Gimbal*1 DUO Handles*1 Single Handle*1 Short*1 Len Holder*1 3-1-a Connecting Arm*1 L-Shape Mounting Plate*1 Long*1 1/4 Inch Screw 18350 Battery*4 USB Cable*2 Battery Changer*2 b. Adjust tilt axis balance in vertical direction: Place the gimbal like picture 3-1-b, hold the roll axis and keep it in horizontal steady,position the camera lens pointing upwards, then loosen the lens, observe the camera status. Allen Wrench*1 If camera lens tilts backwards Quick Installation 1.Insert 4PCS 18350 batteries, ensure battery positive pole upside 2.Camera Installation:(1)Install Mounting Plate *4 PCS (Please use the standard charger for charging) Adjust the screw making mounting plate appropriate position. 1/4 Inch short screw*1 Ensure the camera tightly close to mounting plate margin If camera lens tilts forwards Loosen the thumb screw 4 on tilt axis, move the camera downwards through sliding arm until camera is balanced. Move the camera upwards through sliding arm until camera is balanced 3-1-b (2)Balancingthe Roll Axis Multiple Configurations Place the gimbal like picture 3-2, hold the rollaxis and stay level, then loosen the camera, observe the roll axis status. By using 1/4 camera long screw to lock the DUO handles If camera flops left If camera flops right Upright mode Underslung mode Briefcase mode Vertical hold mode Operating Instructions 5-Way Jostick Loosen the thumb screw 1, move the camera to right side until camera is balanced 3-2 UP/DOWN:Adjust tilt angle Loosen the thumb screw 1, move the camera to left side until camera is balanced. Single press:Panning mode following, tilt axis&roll axis both locked, camera can move to left or right smoothly, indicator light flash for once. Double press: Panning&Tilting mode following,roll axis locked, camera can move to left/right, and pitch rotate, indicator light flash for twice. Triple press: locked mode, all 3 axis locked, the camera stays in its current orientation, indicator light flash for triple. Long press for 6 seconds: Enter into initialization calibration mode,status light is normal on. (3)Balancing the Pan Axis Place the gimbal like picture 3-3, hold the pan axis and stay level balanced, then release the camera, observe the lens status. If camera flops left Horizontal RIGHT/LEFT: Adjust pan angle Multifunctional button(Switch working modes&status indicator light) If camera flops right Multi Functional Power on: Long press for 3 seconds until the status indicator light flash for twice. Button&Status Power off: Long press for 3 seconds until the status indicator light flash for twice. Indicator Light *More controllable functions can be realized by connecting auxiliary device in the UART extended port. Loosen the thumb screw 3 on pan axis, move the camera to right side until camera is balanced. 3-3 Loosen the thumb screw 3 on pan axis, move the camera to left side until camera is balanced. 4.Lens Is Fixed By The Lens Holder After tilt, roll, pan axis balancings done, fix the lens by lens holder. APP Connecting Instruction (1) Scan the QR code and download APP “Hohem Gimset” in APP Store or Google Play (Support iOS system 8.0 or above and Android system 4.4 or above) (2)Launch the bluetooth on the smartphone (3) 镜头。 b.Loosen screw bolt on the lens holder, and fix the lens with shockproof cotton strip to the lens holder Please scan the QR code to get more functions introduction Click the correct model a.To adjust the lens holder position as per the final lens position. Connect the device Make sure the bluetooth is connected Please scan the QR code to get more products enquiries FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐ Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement, The device can be used in portable exposure condition without restriction Federal Communication Commission (FCC) Radiation Exposure Statement Power is so low that no RF exposure calculation is needed.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : hailie Create Date : 2017:11:20 17:16:32+08:00 Modify Date : 2017:11:20 17:17:00+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2017:11:20 17:17+08:00 Creator Tool : Microsoft® Office Word 2007 Format : application/pdf Creator : hailie Document ID : uuid:4a24de71-262b-42e9-812c-95b0d1e2cbff Instance ID : uuid:d2852102-77fc-4b4f-b5ff-b919c096db2d Producer : Microsoft® Office Word 2007 Page Count : 3EXIF Metadata provided by EXIF.tools