Honeywell Security Sensor CoE PP200850SE DUAL TEC Motion Sensor User Manual DT8050

Honeywell Security Sensor CoE DUAL TEC Motion Sensor DT8050

Contents

User Manual (DT8050).pdf

Download: Honeywell Security Sensor CoE PP200850SE DUAL TEC Motion Sensor User Manual  DT8050
Mirror Download [FCC.gov]Honeywell Security Sensor CoE PP200850SE DUAL TEC Motion Sensor User Manual  DT8050
Document ID2193678
Application ID7kokMbg0l6FxYgErhiKGVw==
Document DescriptionUser Manual (DT8050).pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize92.13kB (1151566 bits)
Date Submitted2014-02-19 00:00:00
Date Available2014-03-06 00:00:00
Creation Date2014-01-14 11:24:34
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2014-02-17 13:28:10
Document TitleUser Manual (DT8050).pdf
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: E727032

DRAFT - INSTALLATION INSTRUCTIONS - English (for Website) - 01/14/14
DT8050 DUAL TEC® Motion Sensor - Installation Instructions
QUICK LINKS
Mounting Location Guidelines
Open the Sensor
Mount the Sensor
Sensor Components and Settings
Wire the Sensor
Walk Test the Sensor
Detection Patterns
Relay Operation
Troubleshooting
Sensor Specifications
Accessories
Approval / Listings
Mounting location guidelines:
• The optimal range is obtained at a
mounting height of 7’ 6” (2.3 m).
• Allow a clear line-of-sight to all areas to protect.
• Do not directly face windows.
• Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources.
1. Turn the arrow to point to the Unlock symbol.
2. Press firmly on housing latch.
3. Gently separate the front and rear housing.
• [A] = Wall mounting holes.
• [B] = Corner mounting holes.
• The rear tamper plate MUST be
mounted to a stud, solid wood, or
with a robust wall anchor.
-2-
1. Close the sensor and apply power to the sensor. Initialization is complete
when the LED stops flashing slowly (about 30 seconds).
2. Walk through the detection area and observe the LED.
3. Adjust the microwave range as necessary to meet installation requirements.
LED
Power
Up
Walk Test
Normal
Trouble
Red
Slow
Blink
ON
Alarm
ON
Alarm
Fast
Blink
Yellow
OFF
Green
OFF
ON
ON
Microwave Microwave
ON
PIR
ON
PIR
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature:
Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable Dip switch setting.
Flashlight Feature:
1. Use a flashlight with a bright light beam, and stand within 4’ (1.2 m) of the sensor.
2. Swing the light beam past the sensor IR window 3-5 times, holding the beam on the
window for 0.5 second each pass.
The flashlight feature is only available for the first 24 hours after the first power up.
Zones
2 Look-down
B 18 Lower
C 46 Intermediate
D 36 Long
-3-
OFF
OFF
ACCESSORIES
RELAY OPERATION
Normal
Closed
Alarm Relay
SENSOR STATUS
Intrusion
Trouble1
Open
Open
For information on Trouble conditions, see the Troubleshooting section.
TROUBLESHOOTING
Alarm Relay
Red LED
NORMAL
Closed
Off
TROUBLE*
Self-Test Failure1
Closed
Flashing
SMB-10
(P/N 0-000-110-01)
Swivel Mount Bracket
SMB-10C
(P/N 0-000-111-01)
Swivel Mount Ceiling Bracket
SMB-10T
(P/N 0-000-155-01)
Swivel Mount Bracket w/Tamper
DT8-G2 Lens Kit
(P/N DT8G2LENS5PK)
Replacement Fresnel Lens Kit – 5 Pack
*TROUBLE CONDITIONS:
Self-Test Failure conditions:
• Microwave supervision failure: The sensor is operating in PIR mode only.
• PIR self-test failure: The sensor is disabled.
• Temperature compensation failure: The temperature compensation is
disabled.
Depending on the Trouble condition, take the following corrective actions:
• Verify the power supply is sufficient (at least 9V at the sensor).
• Cycle power to the sensor.
• Walk test the sensor.
APPROVAL / LISTINGS:
If the Trouble condition does not clear, replace the sensor.
Product must be tested at least once each year.
For appropriate wiring methods, refer to the National Electrical
Code NFPA 70 and the Canadian Electrical Code (where
applicable).
Power must be provided by a power-limited UL603 Listed
burglar alarm power supply with minimum 4 hours of standby
power capability, or from a power-limited output of a UL Listed
burglar alarm control unit with minimum 4 hours of standby
power capability.
Accessories not evaluated by UL. For UL applications, enable
look down.
•
•
•
•
•
SPECIFICATIONS
Range: 53’ x 60’ / 16 m x 18 m
Power: 9.0 - 15 VDC; 15 mA typical, 17 mA maximum, 12 VDC;
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Alarm Relay: Energized Form A; 30 mA, 25 VDC, 22 Ohms resistance
maximum. Alarm Relay Duration: 3 seconds
Tampers: Cover & Wall; (NC with cover installed) Form A;
30 mA, 25 VDC
Microwave Frequencies: 10.525 GHz
RFI Immunity: 20V/m 10-1000MHz, 15V/m 1000-2700MHz
FCC part 15, Class B verified
IC ICES-003, Class B verified
UL 639
ULC S306-03
SIA-PIR-01 Passive Infrared detector standard features for
false alarm immunity.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized
by the Installation Instructions or User's Manual. Unauthorized changes or modifications
could void the user's authority to operate the equipment.
PIR White Light Immunity: 6,500 Lux typical
Fluorescent light filter: 50 Hz / 60 Hz.
Operating Temperature: 14° to 131° F / -10° to 55° C
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for
use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used
properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply
with the limits for a Class B computing device in accordance with the specifications in Part
15 of FCC Rules, which are designed to provide reasonable protection against such
interference in a residential installation. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television
receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
Relative Humidity: 5 to 95%; non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 4.57” H x 2.76” W x 1.69” D /
9.8 cm H x 5.7 cm W x 4.35 cm D
Weight: 3.6 oz / 102 g (net weight)
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries
Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit
pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue
y compris les interférences causant une réception indésirable.
For the latest documentation and online support information, please go to:
http://www.security.honeywell.com/hsc/resources/MyWebTech/
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Made in China.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
P/N 800-16696 12/13 Rev A
-4-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2014:02:17 13:28:10+08:00
Create Date                     : 2014:01:14 11:24:34-08:00
Metadata Date                   : 2014:02:17 13:28:10+08:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:a3f718ec-274c-4bed-ab8a-c145d9aeb886
Instance ID                     : uuid:e902c07a-3d2e-404e-bea3-081284223c45
Subject                         : 3
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : E727032
Producer                        : Adobe PDF Library 11.0
Keywords                        : 
Source Modified                 : D:20140114192403
Company                         : Honeywell
Has XFA                         : No
Page Count                      : 4
Page Layout                     : OneColumn
Author                          : E727032
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABC8-PP200850SE

Navigation menu