Honeywell 202516TXR Lamp Controller User Manual Manual
INNCOM International Inc. Lamp Controller Manual
Manual.pdf
L506 Wireless Lamp Control Module Installation Guide The L506 FET 3. Use the L506 module dimmer can drive only with a recognized Derating: Do not exceed an ambient dimmable CFL or listed lamp holder air temperature of 25˚C surrounding loads and other assembly. the L506 Lamp Controller when loads: • • • 100W CAUTION: The distance operating the lamp with the specified between the bulb and the loads and orientations, as outlined in shade should be equal to or the following table. Incandescent greater than required by the original 35W Dimmable CFL or 100W UL listing for the lamp base. incandescent equivalent Improper placement is a fire hazard. Maximum Ratings 25W LED or 100W incandescent equivalent Mounting Vertical Base Down (bulb up) or Horizontal Vertical Base Up (bulb down)* The L506 may be mounted in Incandescent 100W 60W As an alternative to the L206 lamp vertical/bulb up, horizontal, or 35W 20W socket module, the L506 provides vertical/bulb down fixtures. CAUTION: Dimmable CFL wireless lamp control with a smaller The bulb-down orientation should footprint. Designed for standard generally be confined to open air medium lamp sockets (E26 Edison), installations; if used with a shade, the the RF-equipped device can be fixture should be further derated (see controlled from any INNCOM IRAS table below). device with an RF transceiver. The socket is equipped with a mechanical must be located within 60 ft. of an on position, then remove or originating RF transmitter (any IRAS disable it. RF device can be configured as a The L506 dimmer-equipped lamp repeater). The L506 must be must be within 60 feet (indoors) of commissioned. The outline below an RF transceiver/repeater. assumes the installer understands 3. Unplug the lamp cord from the the commissioning process in power source (e.g., wall socket). general; specific commissioning 4. Remove any shade and lamp procedures can be found on the harp. property-specific commissioning Remove the bulb; screw the L506 sheet. 2. The installer must be a trained, experienced service technician. When installing this product: 5. 1. Read the instructions carefully. dimmer/switch into the lamp Failure to follow them could damage the product or cause hazardous conditions. 2. Check the ratings given in the product guide to make sure the product is suitable for your application.. the built-in on/off button. For remote and dimming operation, the L506 lamp socket types. Installation The L506 can switch on a light using switch, make sure it is in the full assist in device binding. The L506 sibling products designed for other Communications If the lamp’s Edison socket has a 1. button that can control the load and series will eventually incorporate LED 25W 10W *Open air only. If fixture enclosed, further derating is necessary socket. 6. Reinstall the bulb, then the lamp harp (if used). Rotate the harp if necessary to clear the L506 socket. Plug the lamp back into the power supply. Commissioning The L506 must be bound to an RF control device such as an e528 thermostat. 1. The L506 enters bind mode for the first 2 minutes after powering up; www.inncom.com to re-enter bind mode, unscrew Parameter Rating the L506 from the fixture and then Dimensions: screw it back in. 2. On the e528, enter the Service Approvals • Press and hold the F°/C° button FCC Part 15b, Class A, UL following measures: —Reorient or relocate the receiving —Increase the separation between This equipment has been tested and experienced radio/TV technician for Press OFF/AUTO; a single beep found to comply with the limits for a help. should sound. Class B digital device, pursuant to • Press and release DISPLAY • Release F°/C° Use the UP or DOWN arrows to (ADR). Press DISPLAY. Use the UP/DOWN arrows to enter the ADR value from the commissioning sheet. 6. correct the interference by one of the This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. go to the Address parameter 5. W x 98mm H (with antenna. Press and release OFF/AUTO 4. the user is encouraged to try to FCC ID: GTC202516TXR • 3. 63.3mm L × 47.3mm socket) menu. by turning the equipment off and on, On the L506, press and hold the the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an Part 15 of the FCC Rules. These Any changes or modifications not The e528 will beep quickly 3 times limits are designed to provide expressly approved by the party to confirm binding. reasonable protection against responsible for compliance could harmful interference in a residential void the user's authority to operate installation. This equipment this equipment. L506 can control the lighting load. generates, uses, and can radiate C ID: 1609A-202516TXR Press and hold the button to adjust radio frequency energy and, if not This device complies with Industry installed and used in accordance with Canada license-exempt RSS the instructions, may cause harmful standard(s). Operation is subject to interference to radio the following two conditions: (1) this communications. However, there is device may not cause interference, no guarantee that interference will and (2) this device must accept any not occur in a particular installation. If interference, including interference built-in on/off button for 5 seconds. Operation Besides being used in the binding operation, the built-in button on the lighting (dimming) levels up or down. A quick press will turn the light off or on. The L506 has a status indicator LED. When the lamp is on, the LED is too. Technical Specifications Parameter Power Rating 110-120VAC, 50/60Hz 0.9A dimmable output Standby power Standby current Operating Environment 1.3W 11mA 0–25 C˚ this equipment does cause harmful that may cause undesired operation of the device. interference to radio or television reception, which can be determined Le présent appareil est conforme aux www.inncom.com CNR d’industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. www.inncom.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 3 Producer : GPL Ghostscript 8.15 Create Date : 2013:03:19 13:18:03 Modify Date : 2013:03:19 13:18:03 Title : Microsoft Word - L506 Installation Guide v1.0 IG 3-19-2013.docx Creator : PScript5.dll Version 5.2.2 Author : mahussainEXIF Metadata provided by EXIF.tools